| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.5 LAccepted-AOC C O VAUDE VILLE HARDWARE OPP IOC DZUVURU KOHIMA NAGALAND 797 001 | KOHIMA | KOHIMA | NAGALAND | 797001 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹10.2 L+₹59,591.50 (6.18%)Rejected-Finance C O HILL HARDWARE STORE P R HILL KOHIMA NAGALAND | PHEK | NAGALAND | 797104 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹12.3 L+₹2.7 L (28.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹19,200
Closing Date
2 Aug 2022, 6:00 pmClosed
AGE (I) ZAKHAMA
C/o 792 FPO PIN-900792 C/O 99 APO
SPECIAL REPAIRS TO BLDG NO T-690(JCO LIVING) AT ZAKHAMA MILITARY STATION UNDER AGE(I) ZAKHAMA.
2022_MES_535908_1
8081
Open Tender
Civil Works
Item Rate
180 days
AGE (I) ZAKHAMA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE (I) ZAKHAMA
₹19,200
19 Aug 2022
5 Jul 2022
5 Aug 2022
5 Jul 2022
2 Aug 2022
19 Jul 2022
Amount
Dismantling of plain or corrugated steel sheeting, any gauge or any thickness as in roof covering, wall cladding etc., complete all as specified and as directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated trapezoidal profile steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws complete all as specified and directed.
M&L Pre- painted hot dip aluminium Zinc alloy metalic coated plain steel sheet 0.50mm thick ( Total coated thickness), any pattern corresponding to IS 15965 : 2012 of durability class 3, atmospheric classification category 3, coating class AZ 150 of an approved colour having yield strength of 550 Mpa as in roof covering/wall cladding, fixed with self tapping screws as specified complete all as specified and directed. Note: To be executed for provision of ridges and hips.
S&F suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm c/c,so as to form 600mm x 600 mm grid including taking out old ceiling of any description complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floor and paving not exceeding 15 cm thick ( Below or above ground) complete all as specified and as directed.
M & L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M & L for PCC 1:3:6, type C1 (using 20 mm graded stone aggregate) as in coping, cills, hold fasts, fixing of post, water trough, lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, etc. including necessary formwork (straight or curved) complete all as specified and as directed.
M&L for extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc. complete all as specified and as directed.
Taking down cement plaster on walls, chajja surfaces, etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and as directed.
M & L for rendering 10 mm thick in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed
M&L for 15mm thick rendering in cement mortar (1:4), in two layers, under coat of 10 mm thick & top of 5 mm thick, to other than fair faces of brick or concrete wall surfaces, top layer 5 mm thick mixed with water proofing compound (@ 3% by weight of cement or as per manufacture's instructions), finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound will be measured and paid separately as "Supply only".
Supply only integral water proofing compound complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and as directed.
M& L for Preparation of old plasterrd surface of walls and applying two coats of oil bound distemper complete all as specified and as directed.
M&L for preparation of newly plastered surface of walls and applying two coat of cement base paint over a coat of primer complete all as specified and as directed.
M&L for preparation of old plastered surface of walls and applying two coat of cement base paint complete all as specified and as directed.
Dismantling timber scantling 40Sqcm and over in section as in unframed work in any position complete all as specified and as directed.
Taking down shutter of any description area n.exc 1 sqm each including builders hardware complete all as specified and as directed.
Taking down shutter of any description area exc 1 sqm but n exc 2 Sqm each including builders hardware complete all as specified and as directed.
M&L for 2nd class hard wood, in scantlings, clean sawn timber as in un framed work complete all as specified and as directed.
S&F 30mm thick flush shutter, solid core construction with particle board core and plywood face panel, commercial type on both side complete all as specified and directed.
S&F 30mm thick second class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauge etc with plain, chamfered or rounded, mitred beads (with sash bars) for securing glass etc, sizes of members of shutters all as specified in SSR part-I section 8 clause 8.24 (b) complete all as specified and directed.
M&L for prelaminated particle board 18/19mm, exterior grade prelaminated one side with decorative choice lamination and other side balancing white lamination, fixed with screws as in pelmet box includind taking out old pelmet box of any description complete all as specified and as directed.
M & L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood or wood based materials of any description exceeding 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of steel and iron work of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
S & F 100 mm size stainless steel butt hinges, complete all as specified and as directed.
S & F 75 mm size stainless steel butt hinges, complete all as specified and as directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 100mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
S&F 100 mm long extruded aluminium alloy handles, fabricated type anodised complete all as specified and as directed.
S & F 250 mm long aluminum alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of steel, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified and as directed.
S & F in repairs, Statin-less steel wire cloth, 0.36 mm dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed.
S & F 20mm to 25mm dia stainless steel tubular curtain rod fancy type including brackets, stops, rollers etc complete all as specified and as directed.
Hacking out old broken glass of any thickness, size quality or description from wooden frames glazed with putty or fixed with bead complete all as directed.
S & F 3mm thick sheet glass, ordinary quality and glazing with oil putty in square in each pane complete all as specified and as directed.
M & L for 25 mm thick PCC 1:2:4, type B0 using (12.5 mm graded stone aggregate) as in floors to receive tiles complete all as specified and as directed.
M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, laid in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 15mm thick screed bed in cement mortar 1:4 complete all as specified and as directed.
M & L for vitrified ceramic tiles, light shade, 10mm thick (square/rectangular) area of each tile not exceeding 0.36 sqm, in skriting dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M & L for coloured non-skid ceramic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc. over and including 15 mm thick screed bed in cement motar 1:4, set and jointed in neat cement slurry and pointed in white or coloured cement to match colour of tiles, complete all as specified and as directed.
M&L for glazed light coloured/printed ceramic tiles 350x250x7mm/450x350x7mm thick in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry pointed in white or coloured cement to match colour of tiles, over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and as directed.
M & L for Dora stone tiles 300mmX300mmX10mm to 15mm thick, set jointed and pointing in neat cement slurry in floor including 15 mm thick screed bed in cement Mortar (1:4) complete all as specified and directed.
S & F in repairs, Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P Trap and provision of concrete bedding and making good to floor complete all as specified and as directed.
S&F in repairs, 10 Litres capacity PVC valveless syphonic action type, flushing cistern, low level, white or coloured, with inlet, ball valve, float and handle including brackets,PVC connection pipe 15mm dia, 450mm long etc complete all as specified and as directed.
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M&L for point wiring with 1.5 sqmm, single core, PVC insulated and PVC unsheathed FRLS cable, 1100 volts grade IS-694 marked, with multistranded copper conductors and earth continuity wire with 1.5 Sqmm copper conductor cable (including connecting to earth dolly) laid/fixed with and including PVC Casing and Caping on walls/ceiling, and with PVC switch board for mounting switches/socket etc for one light/fan/exhaust fan point controlled by one number one way 5 Amp switch complete all as specified and as directed.
All as per item serial No 47 here-in-before but for One 3 pin 5 Amp socket outlet on same board with other switches.
All as per item serial No 47 here-in-before but for One 3 pin 5 Amp switch socket outlet on independent board.
All as per item serial No 47 here-in-before but with 2.5 Sqmm single core multistranded copper conductor cable and earth continuity wire with 2.5 Sqmm cable for 6 pin 15 Amp socket outlet on independent board.
S & F switch piano, flush type single pole one way 5 Amps 230 volt complete all as specified and as directed.
S&F socket outlet 3 pin, 2-in-1, 5 Amps, flush type complete all as specified and as directed.
S & F switch socket combination outlet 5 pin, 2-in-1, 5 Amp flush type complete all as specified and as directed.
S & F switch socket combination, multipurpose, 2 in 1, 6 pin, 5 & 16 Amp flush type complete all as specified and as directed.
S & F ceiling rose surface bakelite, 65x50mm three terminal complete all as specified and as directed.
S&F in repairs LED box type fitting pre-wired including LED tube 1x10W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable and fix on 2 no of PVC block complete all as directed. Make:- Jaguar Model-LGLZ01X010XC/ LGLZ01X010XN/LGLZ01X010XW or Make:- Havells Model-LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/Cromptonor equivalent model of make Philips /GE/Crompton
S&F in repairs, LED box type fitting pre-wired including LED tube 1x20W connecting up with aluminium housing and sheathed 1100 volt grade flexible copper cable & fix on PVC block complete all as directed. Make:- Jaquar Model-LGLZ01X020XC/ LGLZ01X020XN/LGLZ01X020XW or Havells Model-LUMILINEPLUSBS20WLED865SPCSS or equivalent model of make Philips /GE/Crompton
S & F in repairs, single pole & neutral DBs 8 Ways, double door, protection class IP-43 suitable for mounting MCB, DBs conforming to IS-13032, IS-8623, BS-5484 with min 100 Amp rating copper bus bar complete all as specified and as directed. Make :- Legrand Cat No 5076 11 or equivalent model in Siemens / Schneider
S&F PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 150 mm and 50 mm deep complete all as specified and as directed.
S&F MCBs, SPN 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4086 09 to 17 or equivalent model in Siemens / Schneider/L&T
S&F MCBs, SP 6 to 32 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed. Make :- Legrand Model 4085 90 to 95 orequivalent model in Siemens / Schneider/L&T
S&F RCBOs, double pole ,30mA , 6 to 32 Amps for earth leakage ,overload & short-circuit protection complete all as specified and directed.
M&L for Sub main wiring with 2 runs of 6.0 sqmm, single core, FR-LSH PVC insulated & unsheathed cable conforming to IS-694, 1100 volts with copper conductor multi stranded drawn in and including 20mm dia non metallic PVC grey conduit with all accessories such as Tees, Elbows, junction box, reducers etc as requied alongwith one run of 6.0 sqmm single core FR-LSH PVC insulated & unsheathed copper conductor as continuos earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and type of conduit complete all as specified and directed. (Note: 2 run of 6 Sqmm cable and 1 run of 6 Sqmm cable along with conduit altogether shall be measured as one unit.)
S&F 1100 volts grade heavy duty flat cable of size 10 Sqmm 2 core, PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including replacing 4mm suspension wire including taking down old cable of any descrip[tion complete all as specified and as directed.
M&L for GI bracket made out of 40 mm bore medium grade GI Pipe with two sets clamps, with nuts and bolts, bend to shape all as directed, length of GI Pipe shall not be less than 3.0 metre for fixing of light fittings including taking out old bracket complete all as specified and as directed.
S&F in repairs LED building security luminaries 20 Watts energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having IP65 protection and Impact resistance of IK07 with 10KV Built-in Surge Protection Device including testing on completion complete all as specified and as directed. Make: Havells CAT No. ENDURAPEARLSL20WLED757SASYTOPCMP or equivalent of Philips/Crompton/CG
S&F ventilating fans AC single phase 230/ 240 V of size 300 mm sweep with louver shutter with frame and necessary fixing accessories , writing MES No. with black synthetic enamel paint 2 cm high in letter complete with necessary connection up including provision of three core copper flexible cable with flexible wire cover of plastic white in color and connection from ceiling rose to exhaust fan terminal etc complete all as specified and as directed. Make-Usha or equivalent make in Crompton, Bajaj Note:- the cost of making hole in walls/other surfaces & making good the disturbed surfaces includind any framework or wood work required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit qouted rates.
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate at a depth not less than 1.5 m below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and incl GI earth lead wire 4 mm dia or 8 SWG bolted (with GI nuts, bolts & check nuts) and earth plate electrode at one end and connected to main switch board/ DBs etc. at the other, earth strip encased(protected) in and including 15 mm bore GI pipe medium grade with all fittings from top of electrode to main switch board/ DBs etc fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe medium grade from bottom of earth pit to top of electrode complete with earth pit in PCC 1:2:4 type B-2 using 12 mm graded crushed stone aggregate, RCC cover, funnel, wire mesh including necessary excavation and earth work complete all as specified and shown in electrical plate No 3 of SSR Pt-I including taking out old earthing complete all as specified and directed.
thepfuralie zutso
commercial enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .