Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
7 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
MAINTENANCE OF AFLS CABLE AT BHISIANA UNDER GE (AF) BHISIANA
2026_MES_794338_1
GE/BHI/TOKEN-74/2026-27
Open Tender
Civil Works
Item Rate
335 days
GE (AF) BHISIANA
As per NIT
7 documents required · 7 mandatory
₹300
GE (AF) BHISIANA
₹10,000
Yes
GE (AF) BHISIANA
16 Oct 2026
16 Oct 2026
9 Nov 2026
16 Oct 2026
7 Nov 2026
31 Oct 2026
16 Oct 2026 - 30 Oct 2026
23 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Providing unskilled mazdoor/labour for assisting in repair and maintenance of MAFI/AFLS cables and associated installations and carrying out miscellaneous maintenance activities at MAFI, including handling, loading, unloading and shifting of materials, excavation and backfilling, digging and cleaning of ducts and trenches, removal of vegetation, sweeping and cleaning of floors, walls and roofs, both internally and externally, site clearance, and any other incidental labour work assigned by the user or the Engineer-in-Charge for proper maintenance and execution of the work, complete all as specified and as directed by the Engineer-in-Charge.
Notes: (a) The Contractor shall provide all necessary tools, plant, tackles, implements and safety equipment required for the work. The cost of these items shall be deemed to be included in the quoted rates, and nothing extra shall be payable on this account. The Contractor shall be solely responsible for compliance with applicable labour laws, safety precautions and compensation/settlement of claims arising from any accident, injury, disability or fatality involving his workers during execution of the work.
(b) A minimum of 02 (two) labourers shall report to SE(L) at 0900 hrs daily, or as per the working schedule prescribed by the Engineer-in-Charge, to receive the day's work allocation. The labourers shall execute the assigned work as directed by the user/Engineer-in-Charge and submit a completion report to SE(L) on the same day, before 1730 hrs.
(c) The number of labourers deployed may be increased as required by the Engineer-in-Charge, depending on the site requirements and workload on any particular day. The Contractor shall ensure the availability and deployment of the required number of labourers on any day during the currency of the contract. | 4,304 | Per Hour per Mazdoor | - | - |
| 2 | Material and labour for comprehensive preventive maintenance of the existing PLC-based Automatic Mains Failure (AMF) control panel, including checking, servicing, testing and calibration of relays, PLC settings and associated control/protection devices; checking the complete internal wiring and control circuits; replacing damaged or burnt cable thimbles/lugs and other minor defective components; tightening all electrical connections; cleaning the panel internally and externally; checking and replacing defective gaskets; and carrying out necessary minor repairs and adjustments. The work shall include functional testing and verification of each sequence of operation in all operating modes, in the presence of the Engineer-in-Charge/MAFI-in-Charge, after obtaining proper shutdown and ensuring safe isolation of the panel, complete all as specified and as directed by the Engineer-in-Charge/MAFI-in-Charge.
Notes: (i) All work shall be carried out by skilled and experienced personnel having adequate knowledge of PLC-based AMF control panels. (ii) All necessary tools, plant, testing instruments, safety equipment and minor spare parts required for completion of the work shall be provided by the Contractor. The cost thereof shall be deemed to be included in the quoted rate, and nothing extra shall be payable on this account. (iii) Any defective component requiring replacement shall be brought to the notice of the Engineer-in-Charge/MAFI-in-Charge. The classification of any component as major or minor shall be decided by the GE based on its nature, function and cost, and the decision of the GE in this regard shall be final and binding on the Contractor. | 2 | Each Job | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.09 MB
TenderDocToken74.pdf
Tender Documents • 0.59 MB
BOQ_890886.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .