Loading…
Loading…
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
15 Sept 2026, 3:00 pm
BINDEY KUMAR
DIRECTOR
Construction of Prefabricated Structure for 3rd Floor Nursing College Building at IGIMS, Patna
138765
NIT No. :- 03/IGIMS/Engg.Cell /CW &EW/2026-27 gr01
Open Tender
GENERAL
Sheikhpura
• Proof of successful payment of E-Tender Processing Fee
• Proof of successful payment of Cost of Bid Document
• Earnest Money Deposit (EMD) Receipt or Valid Bank Guarantee, as applicable
• Valid Contractor Registration Certificate in appropriate Class/Category
• Experience/Completion Certificates satisfying the prescribed eligibility criteria
• Valid GST Registration Certificate
• PAN Card and Income Tax Return Acknowledgements for the latest applicable Assessment Years
• EPF Registration Certificate with latest challan or valid undertaking for non-applicability
• ESIC Registration Certificate with latest challan or valid undertaking for non-applicability
• Audited Financial Statements/Annual Turnover for the last three Financial Years along with Chartered Accountant?s Certificate
• Solvency Certificate (where applicable as per NIT)
• Bidding Capacity Statement with details of ongoing commitments
• Details of Technical Personnel proposed for deployment
• Details of Plant, Machinery, Tools & Equipment with supporting documents
• Power of Attorney/Authorization Letter in favour of the Authorized Signatory
• Prescribed Affidavits, namely: (i) Non-Blacklisting Affidavit, (ii) Conflict of Interest Affidavit, (iii) Near Relative Affidavit, (iv) Litigation History Affidavit, (v) Financial Availability Affidavit, and (vi) Electrical License Affidavit (where applicable)
• Declaration regarding correctness and authenticity of information/documents submitted
• Acceptance of Tender Conditions through Digital Signature Certificate (DSC)
GENERAL
ITEM RATE
L1
1
18 documents required · 18 mandatory
₹10,000
Processing Fee: 5900
₹3.0 L
25 Aug 2026
25 Aug 2026
18 Sept 2026
25 Aug 2026
15 Sept 2026
25 Aug 2026
Dismantling doors windows and clerestory windows (steel or wood) shutters including chowkhats, architrage, holdfasts etc. complete and stacking within 50 m lead.,
Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead:
Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead:
Excavation in dumped stones or malba including stacking of serviveable and unserviceable material separately and disposal of unserviceable material lead upto 50 m and lift upto 1.5 m disposed material to be neatly dressed.
Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of ng,shuttering,finishing and reinforcement- All work puto plinth level
Centring and shuttering including strutting,propping etc. and removal of form for.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Brick work with bricks of class designation 100A in foundations and plinth in :
Extra for Brick work in superstructure above plinth level upto floor V level
12mm cement plaster of mix :
15 mm cement plaster on rough side of single or half brick wall of mix.1:4(1 cement: 4 coarse sand )
6 mm cement plaster to ceiling of mix :
Providing and applying white cement based putty of erage thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Distempering with oil bound washa ble distemper of approved brand and manufacture to give an even shade .New work (two or more coats ) over and including priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:One or more coats on new work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. All complete.
Providing and fixing ISI marked flush door shutters onforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standardtubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing glazing in alumnum door, indow,Ventilator shutter and partition etc.with EPDM rubber/neoprene gasket etc. Complete as per the architectural drawings and the irection of engineering-in-charge.(cost of alluminium snap beading shall be paid in basic item.)
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc.complete.Size of Tile 600x600 mm.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutoutsmade with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and laying in sssitu five course water proofing treatment with glass fibre tissue reinforced bitumen over roof consisting of first coat of bitumen primer @ 0.40 kg. per sqm, 2nd & 4th courses of bonding material® 1.60 kg. per sqm which shall consist of blown type bitumen of grade 85/25 conforming to IS: 702, third layer of glass ffibre tissuue course as specified, fifth, the top most layer of stone grit 6 mm and down size or pea-sized gravel sprad @ 6 dmJ per sqm including preparation of surface excluding grading for slope etc. complete.
Cement plaster in course sand 20 mm cement plaster of mix:1:4(1 cement :4 coarse sand)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
Providing and fixing water closet squatting Pan ( Indian Type W.C Pan ) with 100mm sand cast iron P or S trap, fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever)conforming to IS: 7231,With all fitting and floors wherever required:
Providing and fixing wash basing with C.I. brackets 15mm C.P. brass pillar taps 32mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting and making good the walls wherever reqire.
Providing and fixing P.V.C. Waste pipe for Kitchen sink or wash basin including P.V.C. waste fitting complete.
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting this includes jointing of pipes & fitting whith one step CPVC solvent cement, trenching, refilling & testing of joints complete as direction of engineer in charge. (External work)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Providing and fixing brass stop cock of approved quality,
Providing and fixing ball valve (brass)of approved quality High or Low Pressur, with plastic floats complee.
Providing and fixing C.P.brass shower with 15 or 20 mminlet.
Providing and fixing on wall face unplastidse -PVC (working pressure 4 kg per sqm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete
Providing and fixing on wall face unplastidse -PVC molded fitting/accessories for unplasticised PVC rain water pipes conforming to S: 4985 including jointing with seal ring conforing to IS:5382 leaving 10 mm gap for thermal expansion.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200mm wide with minimum distances of 37 mm,weighing not less then 88 gms.
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102 mm height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT grating of approved quality and colour.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately
Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note:stainless steel butt hinges and necessary S.S screws shall be paid separately)
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms
Local Sand
Sone Sand
Stone Aggregate ,
Bricks (7P+ 1K)
Difference of Cost of Bricks
Difference of Cost of Cement
Prefab roof made up of panels 100 mm thick sandwich panel of expended polystyrene (EPS) in fills having One sides pre coated galvanised steel sheet of thickness 0.5 mm ( On side flat and other side corrugated) . Profiled roof [panel made up of 100 mm thick having both side pre coated galvanized steel sheet of thickness 0.5 mm polystyrene sandwich panel.
AAC 75mm panel is the shortened from of autoclavec aerated concrete panel . The main materials of AAC panel are sillicon sand cement lime etc. reinforced with anti-stain processed steel Bar the concrete panel with many air holes was formed after high tempretature high pressure protection with steam it is a new type construction meterial with excellent function and performance 75mm aerated board aerocon panels are a result of create greener building hils award - wining R&Dbreakthrough aerocon panels are slim lightweight wall panels that perfectly substitutic plasterboard plywood particle board and brichwalls because of their sheer strength, their low weight ductility fire and moisture resistance properties make them hardy survivors of climatic and accidential disasters being pre- fabricated they are also easy to install and reduce construction time by 80%
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Supplying and fixing following way horizontal type three pole and neutral, sheet steel MCB distribution board 415 volts on surface / recess complete with tinned copper bus bar neutral bus bar , earth bar , din bar interconnections , powder painted including earthing etc as required. ( but without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required
Supplying and fixing single wall mounted 18/22 watt LED typebattenfitting complete with electronic driver and LED tube etc directly on wall/ ceiling including connections with 1.5 sq.mm FR PVC insulated copper conductor and earthing the body etc. as required.
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
IN FIG.
IN FIG.
(A)Instructions to Bidders for Filling Financial Bid
The bidder shall quote the rates in the Price / Financial Bid in typed form only. The quoted rate / percentage shall be clearly mentioned both in figures and in words in the space provided in the BOQ.
Any bid in which the rates are written by hand shall be summarily rejected and will not be considered for evaluation.
The contractor shall quote percentage above / below / at par with the estimated rate for schedule items and item-wise rates for Non-Schedule Items (NSI) as provided in the BOQ.
The quoted rates shall be inclusive of all taxes, duties, labour charges, transportation, loading, unloading, wastage, contractor’s profit and all incidental charges, unless otherwise specified.
Overwriting, cutting or correction in the quoted rates will not be accepted. If any correction is found in the financial bid, the bid may be rejected.
In case of any discrepancy between the rate quoted in figures and in words, the rate quoted in words shall prevail.
The bidder shall carefully examine the site conditions, specifications and BOQ items before quoting the rates, and no claim for additional payment shall be entertained later.
The rates quoted by the contractor shall remain valid till completion of the work and no escalation shall be payable unless specifically provided in the contract.
Name of the Work :-Construction of Prefabricated Structure for 3rd Floor Nursing College Building at IGIMS, Patna
As per generated by www.eproc2.bihar.gov.in
BSR/2022 BSR-23
Dismantling doors windows and clerestory windows (steel or wood) shutters including chowkhats, architrage, holdfasts etc. complete and stacking within 50 m lead.,
Demolishing R.C.C. work including stacking of steel bars and disposal of unserviceable material withing 50 metres lead:
Demolishing brick work including stacking of serviceable material and disposal of unserviceable material within 50 meters lead:
Excavation in dumped stones or malba including stacking of serviveable and unserviceable material separately and disposal of unserviceable material lead upto 50 m and lift upto 1.5 m disposed material to be neatly dressed.
Supplying and filling in plinth with local sand under floors including, watering, ramming consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including delivery as specified.
Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.
Providing and laying in position specified grade of reinforced cement concrete excluding the cost of ng,shuttering,finishing and reinforcement- All work puto plinth level
Centring and shuttering including strutting,propping etc. and removal of form for.
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
Providing designation 100 A one brick flat soling joints filled with local sand including cost of watering, taxes, royalty all complete as per building specification and direction of E/l,
Brick work with bricks of class designation 100A in foundations and plinth in :
Extra for Brick work in superstructure above plinth level upto floor V level
12mm cement plaster of mix :
15 mm cement plaster on rough side of single or half brick wall of mix.1:4(1 cement: 4 coarse sand )
6 mm cement plaster to ceiling of mix :
Providing and applying white cement based putty of erage thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
Distempering with oil bound washa ble distemper of approved brand and manufacture to give an even shade .New work (two or more coats ) over and including priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade:One or more coats on new work
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
Providing and fixing M.S. grills of requirement pattern in frames of windows etc. with M.S. flats, square or round bars etc. All complete.
Providing and fixing ISI marked flush door shutters onforming to IS : 2202 (Part I) non-decorative type,core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters:
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standardtubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.
Providing and fixing glazing in alumnum door, indow,Ventilator shutter and partition etc.with EPDM rubber/neoprene gasket etc. Complete as per the architectural drawings and the irection of engineering-in-charge.(cost of alluminium snap beading shall be paid in basic item.)
Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc.complete.Size of Tile 600x600 mm.
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of ist quality conforming to IS : 15622 of approved make in colours such as white , Ivory , Grey , Fume Red , Brown , laid on 20 mm thick Cement motar 1:4 (1 cement: 4 coarse sand ) including pointing the joints with white cement and matching pigment etc., complete.
Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main "T" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross "T" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge.
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer’s specification and also including the cost of making openings for light fittings, grills, diffusers, cutoutsmade with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and laying in sssitu five course water proofing treatment with glass fibre tissue reinforced bitumen over roof consisting of first coat of bitumen primer @ 0.40 kg. per sqm, 2nd & 4th courses of bonding material® 1.60 kg. per sqm which shall consist of blown type bitumen of grade 85/25 conforming to IS: 702, third layer of glass ffibre tissuue course as specified, fifth, the top most layer of stone grit 6 mm and down size or pea-sized gravel sprad @ 6 dmJ per sqm including preparation of surface excluding grading for slope etc. complete.
Cement plaster in course sand 20 mm cement plaster of mix:1:4(1 cement :4 coarse sand)
Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required :
Providing and fixing water closet squatting Pan ( Indian Type W.C Pan ) with 100mm sand cast iron P or S trap, fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever)conforming to IS: 7231,With all fitting and floors wherever required:
Providing and fixing wash basing with C.I. brackets 15mm C.P. brass pillar taps 32mm C.P. brass waste of standard pattern, including painting of fitting and brackets, cutting and making good the walls wherever reqire.
Providing and fixing P.V.C. Waste pipe for Kitchen sink or wash basin including P.V.C. waste fitting complete.
Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fitting this includes jointing of pipes & fitting whith one step CPVC solvent cement, trenching, refilling & testing of joints complete as direction of engineer in charge. (External work)
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931
Providing and fixing brass stop cock of approved quality,
Providing and fixing ball valve (brass)of approved quality High or Low Pressur, with plastic floats complee.
Providing and fixing C.P.brass shower with 15 or 20 mminlet.
Providing and fixing on wall face unplastidse -PVC (working pressure 4 kg per sqm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10 mm gap for thermal expansion.
Providing and fixing unplasticised -PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing on cement mortar(1:4) 1 cement: 4corsa sand and making good the wall etc complete
Providing and fixing on wall face unplastidse -PVC molded fitting/accessories for unplasticised PVC rain water pipes conforming to S: 4985 including jointing with seal ring conforing to IS:5382 leaving 10 mm gap for thermal expansion.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long,200mm wide with minimum distances of 37 mm,weighing not less then 88 gms.
Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102 mm height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT grating of approved quality and colour.
Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately
Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made.
Providing and fixing factory made single extruded WPC {Wood Polymer Composite} solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives {maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800N {Face) & 900N (Edge), minimum compressive strength 50 N/mm, modulus of elasticity 850 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer-In• Charge. {Note:stainless steel butt hinges and necessary S.S screws shall be paid separately)
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms
Local Sand
Sone Sand
Stone Aggregate ,
Bricks (7P+ 1K)
Difference of Cost of Bricks
Difference of Cost of Cement
Prefab roof made up of panels 100 mm thick sandwich panel of expended polystyrene (EPS) in fills having One sides pre coated galvanised steel sheet of thickness 0.5 mm ( On side flat and other side corrugated) . Profiled roof [panel made up of 100 mm thick having both side pre coated galvanized steel sheet of thickness 0.5 mm polystyrene sandwich panel.
AAC 75mm panel is the shortened from of autoclavec aerated concrete panel . The main materials of AAC panel are sillicon sand cement lime etc. reinforced with anti-stain processed steel Bar the concrete panel with many air holes was formed after high tempretature high pressure protection with steam it is a new type construction meterial with excellent function and performance 75mm aerated board aerocon panels are a result of create greener building hils award - wining R&Dbreakthrough aerocon panels are slim lightweight wall panels that perfectly substitutic plasterboard plywood particle board and brichwalls because of their sheer strength, their low weight ductility fire and moisture resistance properties make them hardy survivors of climatic and accidential disasters being pre- fabricated they are also easy to install and reduce construction time by 80%
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
Supplying and fixing following way horizontal type three pole and neutral, sheet steel MCB distribution board 415 volts on surface / recess complete with tinned copper bus bar neutral bus bar , earth bar , din bar interconnections , powder painted including earthing etc as required. ( but without MCB/RCCB/Isolator)
Supplying and fixing following rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
Supply and installation of 400 mm, 230 V A.C. wall/cabin fan including fixing the bracket, making connection, testing, commissioning etc as required
Supplying and fixing single wall mounted 18/22 watt LED typebattenfitting complete with electronic driver and LED tube etc directly on wall/ ceiling including connections with 1.5 sq.mm FR PVC insulated copper conductor and earthing the body etc. as required.
Supplying and fixing recess mounted 36 watt LED flat panel (2' X 2') with minimum efficacy 100 lm/w which privides soft light and glare free symmetrical illumination suitable for armstrong/grid ceiling and integrated electronic driver etc directly on false ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
Supplying and fixing suitable size Gl box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required.
IN FIG.
IN FIG.
(A)Instructions to Bidders for Filling Financial Bid
The bidder shall quote the rates in the Price / Financial Bid in typed form only. The quoted rate / percentage shall be clearly mentioned both in figures and in words in the space provided in the BOQ.
Any bid in which the rates are written by hand shall be summarily rejected and will not be considered for evaluation.
The contractor shall quote percentage above / below / at par with the estimated rate for schedule items and item-wise rates for Non-Schedule Items (NSI) as provided in the BOQ.
The quoted rates shall be inclusive of all taxes, duties, labour charges, transportation, loading, unloading, wastage, contractor’s profit and all incidental charges, unless otherwise specified.
Overwriting, cutting or correction in the quoted rates will not be accepted. If any correction is found in the financial bid, the bid may be rejected.
In case of any discrepancy between the rate quoted in figures and in words, the rate quoted in words shall prevail.
The bidder shall carefully examine the site conditions, specifications and BOQ items before quoting the rates, and no claim for additional payment shall be entertained later.
The rates quoted by the contractor shall remain valid till completion of the work and no escalation shall be payable unless specifically provided in the contract.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT No. -03-IGIMS-Engg.Cell -CW-EW -2026-27( Tender Details) E-tender.pdf
NIT • 0.96 MB
Approved makelist for civil work.PDF
NIT • 0.17 MB
NIT No. -03-IGIMS-Engg.Cell -CW-EW -2026-27( Tender Details) E-tender-2.pdf
NIT • 0.96 MB
Financial bid -01.xlsx
NIT • 0.05 MB
Annexure-02 for NIt-03 of 2026-27 SL no-01.pdf
NIT • 9.76 MB
Financial bid -01-2.xlsx
NIT • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].