| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.3 LAccepted-Finance 138A STANLEY PARK OTTUPATTARAI POST COONOOR 643 105 THE NILGIRIS TAMIL NADU | THE NILGIRIS | TAMIL NADU | 643105 | L1 | Accepted-Finance Being the Lowest Tenderer | |
| 2 | L2₹36.5 L+₹3.2 L (9.67%)Rejected-Finance CHENNAI | CHENNAI | TAMIL NADU | 600001 | L2 | Rejected-Finance Being Not the Lowest Tenderer | |
| 3 | L3₹42.1 L+₹8.8 L (26.4%)Rejected-Finance H NO 111 553 64 CATTLE POUND TOWARDS AVA HILL CAMP ROAD ARUVANKADU NILGIRIS DIST TAMIL NADU 643 202 | THE NILGIRIS | TAMIL NADU | 643202 | L3 | Rejected-Finance Being Not the Lowest Tenderer |
| Sl No | Description | Qty | Unit | GUNASEKARAN AND CO L2 | sree devi construction L3 | JOE ENTERPRISES L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified out door type, floor mounted, compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs, Led lamps RYB for all incomers & outgoings cables and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete all as specified and directed.
(a) INCOMING:-
(i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 36 KA, 250 Amps 415 Volt - 1 No
(ii) 250 Amp 4 pole Manual changeover switch.
(b) OUTGOING
(i) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 200 Amps 415 Volt - 1 Nos
(ii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 160 Amps 415 Volt - 1 Nos
(iii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 100 Amps 415 Volt - 2 Nos
(iv) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 63 Amps 415 Volt - 1 Nos
(v) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 25 KA, 40 Amps 415 Volt - 1 Nos
(vi) Astronomical time switch for 24 Hrs setting-1 Nos.
(vii) 2 Pole power contactor AC 3 rating 25 Amps AC1 rating 45 Amps MNX 25-2P type-1 Nos.
(c) 500 Amps aluminium busbar for phase and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set
(d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 Nos
(e) LED type Indication lamp 415 Volts Set of three - 1 Set
(f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.
(ii) Panels shall be placed above 0.6 mtr from ground level.
(iii) Outgoing MCCBs shall be fed with solid busbar connectors.
(iv) Cables shall be terminated using gun metal /SS glands. | 2 | JOB | 2,25,500 ₹4,51,000 | 2,40,000 ₹4,80,000 | 1,75,000 ₹3,50,000 Lowest |
| 2.00 | MCCB 4 pole, 415V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. | 3 | EACH | 9,100 ₹27,300 Lowest | 17,200 ₹51,600 | 9,500 ₹28,500 |
| 3.00 | MCCB 4 pole, 415V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. | 6 | EACH | 13,900 ₹83,400 Lowest | 23,000 ₹1,38,000 | 14,000 ₹84,000 |
| 4.00 | MCCB 4 pole, 415V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed. | 5 | EACH | 18,500 ₹92,500 | 30,000 ₹1,50,000 | 15,500 ₹77,500 Lowest |
| 5.00 | MCCB 4 pole, 415V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed. | 2 | EACH | 32,600 ₹65,200 | 36,000 ₹72,000 | 28,000 ₹56,000 Lowest |
| 6.00 | MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA complete all as specified and directed. | 1 | EACH | 78,520 ₹78,520 | 60,000 ₹60,000 Lowest | 65,000 ₹65,000 |
| 7.00 | MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. | 3 | EACH | 9,000 ₹27,000 | 15,000 ₹45,000 | 7,500 ₹22,500 Lowest |
| 8.00 | MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. | 4 | EACH | 13,600 ₹54,400 | 16,200 ₹64,800 | 10,500 ₹42,000 Lowest |
| 9.00 | MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed. | 2 | EACH | 15,700 ₹31,400 | 22,000 ₹44,000 | 11,000 ₹22,000 Lowest |
| 10.00 | Repair or replacement of LT busbars shall include dismantling of damaged sections, cleaning of contact surfaces, installation of new busbars of required size, providing insulation using suitable materials, proper alignment and tightening of joints, and ensuring safe condition of system before energizing all as specified and directed.
Note: New busbars required for repair shall be measured separately | 6 | EACH JOB | 900 ₹5,400 Lowest | 3,500 ₹21,000 | 1,000 ₹6,000 |
Tender Value
₹33.4 L
EMD Value
₹66,800
Closing Date
18 Jul 2026, 6:00 pmClosed
GE WELLINGTON
Garrison Engineer Wellington Barrack Post The Nilgiris Pin code-643231
REPAIRS REPLACEMENT OF LT PANEL MCCBs AND CONNECTED ITEMS AT WELLINGTON STATION UNDER GE WELLINGTON
2026_MES_772060_1
8261/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
WELLINGTON
As Per Tender Documents
8 documents required · 8 mandatory
₹500
GE WELLINGTON
₹66,800
Yes
14 Aug 2026
13 Jun 2026
25 Jul 2026
14 Jun 2026
18 Jul 2026
29 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, install, testing and commissioning and testing factory made and tested CPRI type test certified out door type, floor mounted, compertmantalised suitable for 415 Volts 3 phase 4 wire, 50 Hz AC supply system, dust and vermin proof, made of 3.15mm CRCA MS sheet with digital Volt meter, Ammeter, with CTs, Led lamps RYB for all incomers & outgoings cables and base frame of 50x50x6mm angle iron , powder coated, having front and rear openeable hinged double door shutters with aprons for cable entry and locking arrangement complete all as specified and directed.
(a) INCOMING:-
(i) MCCB thermal magnetic release, adjustable over load, 80-100% 4 Pole, 36 KA, 250 Amps 415 Volt - 1 No
(ii) 250 Amp 4 pole Manual changeover switch.
(b) OUTGOING
(i) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 200 Amps 415 Volt - 1 Nos
(ii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 160 Amps 415 Volt - 1 Nos
(iii) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 100 Amps 415 Volt - 2 Nos
(iv) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 16 KA, 63 Amps 415 Volt - 1 Nos
(v) MCCB thermal magnetic release, adjustable over load, 80-100% 3 Pole, 25 KA, 40 Amps 415 Volt - 1 Nos
(vi) Astronomical time switch for 24 Hrs setting-1 Nos.
(vii) 2 Pole power contactor AC 3 rating 25 Amps AC1 rating 45 Amps MNX 25-2P type-1 Nos.
(c) 500 Amps aluminium busbar for phase and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulators in separate compartment - 01 Set
(d) Digital multi function panel meter for measuring voltage, Amps and Frequency with suitable CTs and back up protection - 1 Nos
(e) LED type Indication lamp 415 Volts Set of three - 1 Set
(f) danger notice board of size 200 mm x 150 mm x 1.6 mm thick of mild steel sheet printed with vitreous enabled white paint and letter figure and convention skull and bones of signal red colour and fixed / rivetted with panel -02 Nos
Note:- (i) Rate quoted is deemed to be inclusive of PCC foundation/pedestal and connected earth work.
(ii) Panels shall be placed above 0.6 mtr from ground level.
(iii) Outgoing MCCBs shall be fed with solid busbar connectors.
(iv) Cables shall be terminated using gun metal /SS glands. | 2 | JOB | - | - |
| 2 | MCCB 4 pole, 415V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. | 3 | EACH | - | - |
| 3 | MCCB 4 pole, 415V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. | 6 | EACH | - | - |
| 4 | MCCB 4 pole, 415V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed. | 5 | EACH | - | - |
| 5 | MCCB 4 pole, 415V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and directed. | 2 | EACH | - | - |
| 6 | MCCB 4 Pole, 415 V, Adjustable type, 630 Amps with breaking capacity 50 KA complete all as specified and directed. | 1 | EACH | - | - |
| 7 | MCCB 3 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed. | 3 | EACH | - | - |
| 8 | MCCB 3 Pole, 415 V, Adjustable type, 200 Amps with breaking capacity 36 KA complete all as specified and directed. | 4 | EACH | - | - |
| 9 | MCCB 3 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA complete all as specified and directed. | 2 | EACH | - | - |
| 10 | Repair or replacement of LT busbars shall include dismantling of damaged sections, cleaning of contact surfaces, installation of new busbars of required size, providing insulation using suitable materials, proper alignment and tightening of joints, and ensuring safe condition of system before energizing all as specified and directed.
Note: New busbars required for repair shall be measured separately | 6 | EACH JOB | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_864532.xls
BOQ • 0.29 MB
Tenderdocuments8261.pdf
Tender Documents • 0.79 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .