| 1 | L1₹34.7 LAccepted-AOC 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Awarded Being L1 | |
| 2 | L2₹44.2 L+₹9.6 L (27.6%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹46.1 L+₹11.5 L (33.1%)Rejected-Finance BETONG SHOP KHANGSAR COMPLEX NOWSHARA LEH LADAKH 194101 J K | LEH | LEH | JAMMU AND KASHMIR | 194101 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹48.8 L+₹14.1 L (40.8%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹50.1 L+₹15.4 L (44.5%)Rejected-Finance PHAYANG GOMPA COMPLEX AGLING ROAD SKALZANGLING LEH LADAKH J K 194101 | LEH | LEH | LADAKH | 194101 | L5 | Rejected-Finance Not being lowest |
Tender Value
₹46 L
EMD Value
₹92,000
Closing Date
30 Apr 2021, 6:00 pmClosed
GE
GE 860 EWS
REPAIR MAINT OF DI GI PPR HDPE PIPE LINES INCLUDING VALVES FLUSHING OF BORE WELLS REPAIR TO PUMP MOTORS AND STARTERS SUBMERSIBLE CABLES COLUMNS PIPE CONNECTED ITEMS AT SHESHARTHANG UNDER GE 860 EWS
2021_MES_432661_1
8103/2021-22/E8
Open Tender
Civil Works - Water Works
Item Rate
270 days
Karu
Class D
Category a ii
9 documents required · 9 mandatory
₹500
Yes
GE 860 EWS
₹92,000
Yes
27 May 2021
24 Mar 2021
3 May 2021
24 Mar 2021
30 Apr 2021
16 Apr 2021
Amount
M&L for flushing of borewell complete by using 210 CMF compressor and heavy duty driller machine to deliver the high air pressure at the bottom of the bore well and cleaing/flushing the bore well till the water is become free from any mud and clear for portable complete all as specified and directed by Engineer-in-charge
Material & labour for replacement of GI coloum pipe 40 mm dia medium grade, 3 Mtrs in length , both end flanged, including, including nuts bolts, washer and rubber gaskets etc complete all as speicfied all as specified and directed by Engineer-in-Charge.
Material & labour for replacement of GI coloum pipe 50 mm dia medium grade, 3 Mtrs in length , both end flanged, including, including nuts bolts, washer and rubber gaskets etc complete all as speicfied all as specified and directed by Engineer-in-Charge.
M&L for taking out of u/s electric driven pumping set of capacity 5HP, discharge 3 LPS head 70 to 80 meters alongwith GI coloum pipe 40/50 mm bore flanged at both side and submersible cable from bore for repair/rewinding the submersible pump set complete all as specified and directed by Engineer-in-Charge.
M&L for taking out of u/s electric driven pumping set of capacity 15 HP, discharge 5 LPS head 80 to 120 meters alongwith GI coloum pipe 40/50 mm bore flanged at both side and submersible cable from bore for repair/rewinding the submersible pump set complete all as specified and directed by Engineer-in-Charge.
Taking out the burnt copper winding wire from submersible electric motor of capacity 5 HP and rewinding the submersible electric motor with super enamelled copper wire of existing gauge with proper insulation complete all as specified and directed by Engineer -in-Charge. Make of winding wire ATLAS or equivalent.
Taking out the burnt copper winding wire from submersible electric motor of capacity 15 HP and rewinding the submersible electric motor with super neamelled copper wire of existing gauge with proper insulation complete all as specified and directed by Engineer -in-Charge. Make of winding wire ATLAS or equivalent.
M&L for lowering the submersible electric driven pump set of capacity 5 HP discharge 3 LPS 70 to 80 meters head alongwith GI coloum pipe 40 mm bore flanged both side (old & new GI pipe) complete all as specified and directed by Engineer-in-Charge)
M&L for lowering the submersible electric driven pump set of capacity 15 HP discharge 5LPS 80 to 120 meters head alongwith GI coloum pipe 40 mm bore flanged both side (old & new GI pipe) complete all as specified and directed by Engineer-in-Charge)
M&L for PVC insulated and sheathed multi strandard 3 core 10 sqmm flat 1100 volts grade electric copper submersible cable complet all as specied and directed by Engineer-in-Charge.
M&L for PVC insulated and sheathed multi strandard 3 core 6 sqmm flat 1100 volts grade electric copper submersible cable complet all as specied and directed by Engineer-in-Charge.
M&L for replacement of star coupling with rubber of centrifugal pump set having capacity 20 to 30 HP complete all as specified and directed by Engineer-in-Charge.
M&L for servicing of centrifugal pump electric driven AC 3 phase 415 volts 30 HP capacity by replacing of unserviceable terminal blocks and 2 Nos ball bearing, bushes and bolts and nuts and re-assembling same incl varnishing with super enamelled varnish to motor winding at site including testing complete all as specified and directed by Engineer-in-charge.
M&L for servicing of centrifugal pump electric driven AC 3 phase 440 volts 03 HP capacity by replacing of unserviceable terminal blocks and 2 Nos ball bearing, bushes and bolts and nuts and re-assembling same incl varnishing with super enamelled varnish to motor winding at site including testing complete all as specified and directed by Engineer-in-charge.
S&F GI earth strip of 25x4 mm and required connection with LT panel and DG set etc complete all as specified and directed by Engineer-in-Charge.
S&F in replacement sequence controlle, 220-240V, 50-60 Hz 3VA suitable for Hamam of capacity 50000 Kcal/Hrs. Make : Siemens or equivalent complete all as specified and as directed by Engineer-in-Charge
S&F in replacement transformer 60VA, 0.25A, 50-60 Hz, 230V AC suitable for Hamam of capacity 50000Kcal/Hrs.Make : Danfoss or equivalent complete all as specified and as directed by Engineer-in-Charge
Repair and maintenance of calorifire 415 V, 50 HZ, 3 Phase 4 wire with supply and fixing of following unserviceable parts of Model No WH700 of ALFA-THERM complete all as specified and directed
Ignition Rod
Photo cell
Firing Nozel of Burner
Oil pumpof Burner
Fuel filter
Complete services of Calorifire/Hammam boiler including welding work and connected item
Fuel tank services including painiting enterior and exterior with two coat of synthetic enalmelled paint complete as specified and directed by Engr-in-Charge
Internal rewiring Complete for burner of hamam/Calorifire of capacity 50000 kcal/Hrs all complete as directed by Engineer-in-Charge.
Taking up or down old unserviceable DI/GI tubing connection including disconnection of fittings from tubing where required and cleaning for refixing or removal from site complete as directed by Engr-in-Charge of following sizes :-
PPR/GI pipe 20 mm dia
PPR/GI pipe 25 mm dia
PPR/GI pipe 40 mm dia
GI/PPR pipe 50 mm dia
DI/GI pipe 80 mm dia
DI Pipe of 100 mm bore
Refixing/Relaying of old DI/GI tubing retrieved from srl item No - 1 and connections in new or old position including S & F new tightening rubber complete all as directed by Engr-in-Charge.
PPR/GI pipe 25 mm dia
PPR/GI pipe 40 mm dia
GI/PPR pipe 50 mm dia
GI pipe 80 mm dia
DI Pipe of 100 mm bore
Supply & laying of PPR/GI/DI pipe of the following sizes and grade complete with all fittings laid in trenches complete as directed by Engr-in-Charge, of following sizes (Note when pipe laid in straight line then the 3rd length is required to be connected by union
PPR pipe 3 layer SDR 7.4 , 20 mm dia
PPR pipe 3 layer SDR 7.4 , 25 mm dia
GI pipe, Med grade 20 mm dia
GI pipe, Med grade 25 mm dia
GI pipe, Med grade 40 mm dia
GI pipe, Med grade 50 mm dia
GI pipe, Med grade 80 mm dia
DI pipe of 100 mm bore
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of PPR pipe/GI tubing etc and getting out in hard/dense soil complete all as specified and directed.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil complete all as specified and directed.
Removing excavated material (soils) not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point complete all as specified and directed.
Taking down old unserviceable gate valve / stop valve of any size complete all as specified and directed.
Supply and fixing gun metal, globe or gate valve ISI marked for 50 mm dia pipe with iron wheel head, screwed both ends complete all as specified and directed.
All as per srl item no. 26 here-in-before but of 25 mm dia.
All as per srl item no. 26 here-in-before but of 20 mm dia.
M&L for run lead joint for 100 bore CI/DI pipe all as specified and directed.
Taking down old unserviceable Ball Brass Valve of any size complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule complete all as specified and directed.
All as per item No. 31 here-in- before but 25 mm bore.
Taking down old unserviceable CI sluice valve for 80/100 mm dia pipe complete all as specified and directed.
Supply & fixing cast iron sluice valve for water supply purposes with CI drilled flanged end internally cast for 100 mm nominal bore class PN 1.6 horizontal type conforming to IS 760, ISI marked with stainless steel spindle & iron wheel non using type including jointing material complete such as rubber assertion packing rings with requisite no of nuts & bolts , washers of requisite size etc all as specified and directed by the Engr-in-Charge.
All as per item No 34 here in before but of 80 mm nominal bore
Taking down old unserviceable air release valve of size up to 80/100 mm complete all as specified and directed.
S&F air release valve with double air outlet on existing DI/GI pipe of bore 80 mm complete with drilling, threading, welding and fixing of GI pipe medium grade 25 mm bore all as per site requirement
M&L for replacement of old unsv air release valve with single air outlet in existing DI/GI pipe of bore 100 mm complete with drilling, threading, welding and fixing of GI pipe medium grade 32 mm bore all as per site requirement
Dismantling of unserviceable valve pit of any size complete all as directed by the Engr-in-Charge.
Construction of stone masonary valve pit chamber of size 90cm x 90cm x 160 cm (internal dimension) including all necessary excavation and earth work in hard/dense soil and disposal of surplus soil to a distance not exceeding 50 meters as directed including PCC in foundation of the mixture (1:4:8) type D-2 stone masonary in cement mortor 1:4 rendering 15 mm thick in cement mortar 1:4 internally finished even and fair and pointing flush externaly as the work proceeds in the same mortar as of stone masonary including MS frame (made out of angle in 40x40x6mm) and MS steel cover 3.15 mm thick with handle and locking arrangement with hinges angle iron flat as required at site.
M&L in replacement earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM and frame of suitable size with handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No.5 of SSR 2009 Part-I and connecting to pump motores, MCB DB’s earth test point all as specified or indicated including testing on completion .
Making connection of PP-R distribution branch with PP-R main of size 16 to 40 mm bore by providing and fixing tee including cutting and making fusion joint etc. all as directed.
Making connection of PP-R distribution branch with PP-R main of size 50 to 75 mm bore by providing and fixing tee including cutting and making fusion joint etc. all as directed.
S&F 1000 ltrs capacity rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with threaded closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
S&F 500 ltrs capacity rotational moulded polyethylene water storage tanks triple layered (cylindrical vertical with threaded closed top) hoisted and fixed in position complete all as specified and directed by Engr-in-Charge.
M&L for Cleaning and removing all scales and dirt etc from tanks and from mouths of circulating pipes etc capacity upto 1000 ltrs complete all as specified and directed by Engr-in-Charge.
S&F in replacement star delta stater 3 phase 415 V suitable for 30 HP monoblock/centrifugal pump set and making all necessary connection, complete all as specified and dierected by Engr-in-charge.
S&F in replacement star delta stater 3 phase 415 V suitable for 5 to 7.5 HP submersible pump set and making all necessary connection, complete all as specified and dierected by Engr-in-charge.
M&L for rewinding of centrifugal motor of capacity upto 30 HP AC 3 Phase 415 Volts with super enamelled copper winding wire including appropriate class of insulation to the existing class and replacing with required size of bearing and bushes and testing complete including painting and making all necessary connection, complete all as specified and dierected by Engr-in-charge.
M&L for emptying the tanks, removing complete scalling Cleaning internal wall and bottom throughly by using washing soda and bleaching powder and cleaning with clean water to remove the remains of soda/bleaching powder and apply one coat of cement paint suitable for drinking water applied to entire internal surface of Semi Under ground tank of capacity 25000 litres complete all as specified and directed by Engineer-in-charge.
M&L for Cleaning and removing all scales and dirt etc from under ground sump of cap 50000 Glns including two coats of white wash etc complete all as specified and directed by Engineer-in-charge
M&L for servicing of centrifugal pump electric driven AC 3 phase 415 volts 30 HP capacity by replacing of unserviceable terminal blocks and 2 Nos ball bearing, bushes and bolts and nuts and re-assembling same including varnishing with super enamelled varnish to motor winding at site including testing complete all as specified and directed by Engineer-in-charge.
Construction of Lorry filling point of size 0.6m x 0.6m x 5m using precast cement concrete solid block masonary type C-1, 1:3:6 (20mm graded crushed stone aggregate), exceeding 10cm in width and setting in cement mortal 1:4 over 150mm thick PCC 1:3:6 (nomival mix) type C-2 (using 40 mm graded crushed stone aggregates) complete, 10mm thick rendering in cement mortar 1:4 on concrete surface finished even & smooth without using extra cement The masnory work including PCC sub base shall be 0.80 m below GL including neccessary earth work complete all as specified and directed by Enginner-in-Charge.
Collecting and testing of water sample bottle from Pump houses TCP Shesharthag water point from govt authorised laboratory for testing of various parameters as per IS 10500 complete all as specified and directed by Engr-in-Charge, Note :- Test result will be submitted to AGE B/R office
Feroz Engineering Works
siachen construction co
BETONG BUILDERS
M/S BETONG CONSTRUCTION CO
M/S BHAT ENGINEERS
darshan kumar gandhi
M S GHULAM MOHD BALDER
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .