Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹17.8 L
EMD Value
₹35,700
Closing Date
18 Jan 2024, 4:00 pmClosed
Executive Engineer, ED DODA
ED DODA
CREATION OF 25 KVA DISTRIBUTION SUB STATION AT VILLAGE BAMLAKHI AND 63KVA DISTRIBUTION SUB STATION AT VILLAGE LOWER HADDLE UNDER CLUSTER TRIBAL PLAN
2024_PDD_242319_1
ED Doda/JPDCL/79 of 2023-24
Open Tender
Electrical Works
Turn-key
30 days
ED DODA
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Executive Engineer, ED DODA
₹35,700
19 Jan 2024
8 Jan 2024
19 Jan 2024
8 Jan 2024
18 Jan 2024
9 Jan 2024
Amount
LAYING OF 11 KV LINE FOR CREATION OF 63 KVA SUB STATION AT VILLAGE LOWER HADDAL NEAR THE H/O NELAM RAJ PANCHAYAT BUTLA
SITC OF 8 Mtr. Long ST Pole
SITC OF 30 MMSQ ACSR Weasel
SITC OF GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn gap
SITC OF 11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC OF Galvinized Nuts and Bolts.
SITC OF Danger Plates
SITC OF Anti-Climbing Device with Clamps
SITC OF Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
SITC OF Red Oxide
SITC OF Aluminium Paint
SITC OF Cement bottoming 1:2:4 mix as per REC standards .45 cum/pole
SITC OF 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC OF Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
CREATION OF 63 KVA DISTRIBUTION SUB STATION AT VILLAGE LOWER HADDAL NEAR THE H/O NELAM RAJ PANCHAYAT BUTLA
SITC OF 11/0.433kV, 3-phase Distribution Transformers (63 KVA) with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
SITC OF Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
SITC OF 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
SITC OF 11 kV Horn Gap Fuse Set 3 Phase 200A
SITC OF 9 Mtr. Long Pole( ST-410 SP33)
SITC OF 11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN,
SITC OF GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn gap
SITC OF Nuts and Bolts.
SITC OF Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
SITC OF 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC OF LT Distribution Box for 63 kVA DTR with 100 Amp MCCB for incomer & SFU's for Outgoing Circuits
SITC OF Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
SITC OF PVC Cable120 mmsq single phase cable 1.1 grade PVC insulated stranded conductor FRLS type
SITC OF Danger Plates with Clamps
SITC OF GI Barbed Wire for Anti Climbing
SITC OF Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
SITC OF Red Oxide
SITC OF Aluminium Paint
LAYING OF LT LINE FOR DISPERSION OF POWER FROM 63 KVA NEW SUB STATION AT VILLAGE LOWER HADDAL NEAR THE H/O NELAM RAJ PANCHAYAT BUTLA
SITC OF 8 Mtr. Long ST Pole
SITC OF 30 MMSQ ACSR Conductor
SITC OF Shakle Insulator 16 KN
SITC OF Mukhee Clamps
SITC OF Galvinized Nuts and Bolts.
SITC OF Danger Plates
SITC OF Anti-Climbing Device with Clamps
SITC OF Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
SITC OF Red Oxide
SITC OF Aluminium Paint
SITC OF Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
SITC OF Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
LAYING OF 11 KV LINE ALONG WITH STABILIZATION OF EXISTING HT TAP FOR CREATION OF 25 KVA SUB STATION AT VILLAGE BAMLAKHI PANCHAYAT BHEJA
SITC OF 8 Mtr. Long Pole(, ST-410 SP33)
SITC OF 30 MMSQ ACSR Weasel
SITC OF GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn gap
SITC OF 11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC OF Galvinized Nuts and Bolts.
SITC OF Danger Plates
SITC OF Anti-Climbing Device with Clamps
SITC OF Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
SITC OF Red Oxide
SITC OF Aluminium Paint
SITC OF Cement bottoming 1:2:4 mix as per REC standards .45 cum/pole
SITC OF 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC OF Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
CREATION OF 25 KVA DISTRIBUTION SUB STATION AT VILLAGE BAMLAKHI PANCHAYAT BHEJA
SITC OF 11/0.433kV, 3-phase Distribution Transformers (25 KVA) with Bimetallic Terminal Connectors Energy Level-2, (Al. wound ), and with LV Cable Box
SITC OF Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
SITC OF 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
SITC OF 11 kV Horn Gap Fuse Set 3 Phase 200A
SITC OF 9 Mtr. Long Pole( ST-410 SP33)
SITC OF 11kV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
SITC OF GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn gap
SITC OF Nuts and Bolts.
SITC OF Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
SITC OF 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
32/63 amps TPN Switch Disconnector Fuse Unit
SITC OF Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
SITC OF PVC Cable 50 mmsq single phase cable 1.1 grade PVC insulated stranded conductor FRLS type
SITC OF Danger Plates with Clamps
SITC OF GI Barbed Wire for Anti Climbing
SITC OF Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
SITC OF Sundry items like aluminium lugs, Jumpers, binding Tape,
LAYING OF LT LINE FOR DISPERSION OF POWER FROM 25 KVA NEW SUB STATION AT VILLAGE BAMLAKHI PANCHAYAT BHEJA
SITC OF 8 Mtr. Long Pole( ST-410 SP33)
SITC OF 30 MMSQ ACSR Conductor
SITC OF Shakle Insulator 16 KN
SITC OF Mukhee Clamps
SITC OF Galvinized Nuts and Bolts.
SITC OF Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
SITC OF Aluminium Paint
SITC OF Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
Daya Krishan Raina
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .