Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹18.0 L+₹7,948 (0.44%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.5 L+₹1.6 L (9.12%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹19.7 L+₹1.8 L (10.1%)Rejected-AOC | L4 | Rejected-AOC Other than L1 | |
| 5 | L5₹19.9 L+₹2.0 L (11.2%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
28 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
REPAIR/ MAINT OF DG SETS/ LT VOLTAGE STABILIZER AND EARTHING SYSTEM AT E/M INSTALLATION AT 8FBSU
2023_MES_601762_1
GE (AF) AWA-12/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹36,000
Yes
22 Aug 2023
7 Jun 2023
30 Jun 2023
7 Jun 2023
28 Jun 2023
22 Jun 2023
Amount
M&L for welding of broken Acousting Enclosure Gate of DG Sets of any capacity by providing proper hinge and locking arrangement as per existing size and type for fixing in position, complete all as specified and directed.
Carrying out servicing of DG set of capacity 125/160/200 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/ dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately).
M&L for following parts to be fixed under above item for DG set of capacity 125/160/200 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamps
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
(i) Stop solenoid actuator
S&F in replacement of self starter 12 volts DC suitable for 75 to 125 KVA DG set, Make: Kirloskar complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
S&F in replacement of self starter 24 volts DC suitable for 160 to 320 KVA DG set, Make: Kirloskar complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
Carrying out servicing of DG set of capacity 100 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/ dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately).
M&L for following parts to be fixed under above item for DG set of capacity 100 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
(i) Stop solenoid actuator
Carrying out servicing of DG set of capacity 62.5/63/75 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM, and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil, sludge/dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately ).
M&L for following parts to be fixed under above item for DG set of capacity 62.5/63/75 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary.
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
Carrying out servicing of DG set of capacity 40/35/30/25/10 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM,and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil sludge/dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately .
M&L for following parts to be fixed under above item for DG set of capacity 40/35/25/10 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary.
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
Carrying out servicing of DG set of capacity 320/400 KVA, Make: Kirloskar/Cummins in all respect like checking of diesel engine, multi cylinder and all safety devices, control panel by service engineer / service technician of any reputed service center / auth service center of OEM,and replacement of unserviceable spare parts/accessories including calibration of control devices/ refitting of serviceable parts after cleaning/servicing, cleaning of oil sump and replacement & including minor accessories including draining of oil dust from foundation/base plate complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately ).
M&L for following parts to be fixed under above item for DG set of capacity 320/400 KVA, Make: Kirloskar/Cummins:- (a) Fuel filter primary.
(b) Fuel filter secondary.
(c) Lub oil filter
(d) Air cleaner filter
(e) Hose pipe set with clamp
(f) Flexible pipe with end connector
(g) Fan belt for charging alternator
(h) Fan belt for radiator
Taking out burnt armature, winding wire and rewinding the armature with super enamelled copper winding wire of existing gauge of DG Sets of capacity upto 100 KVA all as specified and directed.
Taking out burnt field coil and rewinding the field coil with super enamelled copper winding wire of existing gauge of alternator of DG of capacity upto 100 KVA DG all as specififed and directed.
M&L for insulation of armature with Class ‘B’ insulation and Varnishing of armature winding and drying up to desired temperature of DG Sets of capacity upto 100 KVA all as specififed and directed.
M&L for insulation of field coils with Class ‘B’ insulation and Varnishing of field coil winding and drying up to desired temperature of DG Sets of capacity upto 100 KVA all as specififed and directed.
Re-assembling of rotor and stator after rewinding and re-fixing of alternator with Engine by assembling flexible coupling with alternator, mounting with nuts & bolts including making cable connection complete including testing and commissioning at desired load of DG set of capacity upto 100KVA complete all as specified and directed.
Servicing, checking and carry out calibration of relays/timers and contactors of AMF Panel/Control Panel of 63/75 KVA DG set including other connected electrical / electronic accessories including necessary wiring and testing complete including fixing only parts/refitting of serviceable parts after cleaning/servicing complete all as specified and directed. (Note:- All defective parts shall be paid & measured separately ).
M&L for following items for AMF/Control Panel of 63/75 KVA DG set to be fixed under above item:- (a) Starting time delay relay.
(b) Engine stop time delay relay
(c) Overload relay
(d) Under voltage relay
M&L for replacement of spare coil of 24volts, 50Hz of 01 MNX, 265/325/400 for 140 contactor,cat no. CS94196 for maping with AMF panel of DG set functional all as specified and directed.
Battery charging transformer, open execution type with diode bridge suitable for charging 12 volts, 180 AH battery with input voltage 230 volts AC all as specified and directed.
Supply and filling lubricant oil 20w40 for topping up/replacement including draining out old oil from engine chamber complete all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
Supply and topping up heavy duty concentrate / antifreeze type coolant in radiator assembly of DG set complete including draining out of used coolant all as specified and directed. Make: Castrol/Volvoline/Servo/HP.
S&F in replacement of rechargeable lead acid battery, 12 volts, 180 AH complete all as specified. Make:- Exide make Exide Xpress model SAP code No. FXPO-MHD 1800 or equivalent in Amron.
S&F in replacement of rechargeable lead acid battery, 12 volts, 150 AH complete all as specified. Make:- Exide make Exide Xpress model SAP code No. FXPO-MHD 1500 or equivalent in Amron.
Supply and topping up distilled water suitable for lead acid battery all as specified. Make: As per sample
S&F in replacement of brass battery terminals suitable for 150/180 AH, 12 Volts battery complete all as specified.
Cleaning of light deposits with low pressure stream jet and if difficult deposits exist the removal should be done with application of detergent and using low pressure hot water hose or immersion in a heated alkali degreasant solution for 20 mins and washing off with hot water hose of radiator assembly of DG Set of capacity 200 to 100 KVA complete all as specified and directed.
Cleaning of light deposits with low pressure stream jet and if difficult deposits exist the removal should be done with application of detergent and using low pressure hot water hose or immersion in a heated alkali degreasant solution for 20 mins and washing off with hot water hose of radiator assembly of DG Set of capacity 75 to 25 KVA complete all as specified and directed.
S&F in replacement of AVR unit complete suitable for alternator of capacity upto 160 KVA matching with existing sample including making all electrical connection and setting at proper voltage complete all as specified.
S&F in replacement of AVR unit complete suitable for alternator of capacity 200 to 400 KVA matching with existing sample including making all electrical connection and setting at proper voltage complete all as specified.
S&F in replacement of charging alternator suitable for charging of 12 volts (1x12 volts), 180 AH battery complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
S&F in replacement of charging alternator suitable for charging of 24 volts (2x12 volts), 180 AH battery complete including dismantling of existing and fixing the new fixing in position, making proper alignment complete all as specified and directed.
M&L for cleaning of diesel tank of capacity 1000 Ltrs (approx) by taking out complete diesel in separate container, cleaning the all sludge, dust & mud of tank including refilling of diesel in tank complete all as specified and directed.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 400 KVA to 100 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Disconnecting main electrical connection of voltage stabilizer of any make, capacity from 75 KVA to 20 KVA and opening of stabilizer cover for checking/examining/replacing as required including connecting the same electrical connection after necessary repair complete all as directed. Note: Spare parts shall be measured & paid separately.
Transportation of voltage stabilizer of any make, capacity from 400 KVA to 100 KVA to civil workshop and returning back after necessary rewinding , repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Transportation of voltage stabilizer of any make, capacity from 75 KVA to 20 KVA to civil workshop and returning back after necessary rewinding ,repairing work including loading & un-loading with & including necessary T&P complete all as specified and directed.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 500 KVA to 100 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
Draining out the transformer oil complete quantity of voltage stabilizer of any make, capacity from 75 KVA to 20 KVA and to keep the same in safe containers dismantling all the parts of voltage stabilizer with the help of hand operated crane or other suitable mean, re-fixing the all parts and assembling with the help of hand operated crane or by other suitable means, re-filing the existing drain out transformer oil and testing the voltage stabilizer complete all as specified. Note:- Spare parts shall be measured & paid separately.
M&L for re-winding of stabilizer of any type/make with superior quality super enamelled copper winding wire of suitable gauge and number of turns alongwith allied materials such as cork sheet, fibre glass insulation/paper isulation cotton, empire tape and woodeen blocks, bolts, nuts and washers, soldering and other packing materials complete all as specified and directed.
M&L for heat treatment at the workshop furnance of complete core before and after re-assembly of coil into limps after rewinding for stabilizer of any make/capacity complete all as specified and directed.
Repairing the voltage stabilizer of any make, capacity from 400 to 200 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.
(b) Circuit control/trigger transformer.
(c ) Main terminal block.
(d) Dimmer
(e) Choke coils.
(f) Carbon brush.
(g) Spacer for Dimmer coils.
(h) Resistance capacitance net work.
(i) Input switch to stop over running of dimmer start motor.
(j) Servo motor with 20 Kg.cm torque.
(k) Driving gear.
(l) Bearing for dimmer coils.
(m) Terminal connections brass rod with bush.
(n) Protection alarm circuit
Repairing the voltage stabilizer of any make, capacity from 150 to 100 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.
(b) Circuit control/trigger transformer.
(c ) Main terminal block.
(d) Dimmer
(e) Choke coils.
(f) Carbon brush.
(g) Spacer for Dimmer coils.
(h) Dimmer coils terminals.
(i) Input switch to stop over running of dimmer start motor.
(j) Servo motor with 10 Kg.cm torque.
(k) Driving gear.
(l) Bearing for dimmer coils.
(m) Terminal connections brass rod with bush.
(n) Protection alarm circuit
Repairing the voltage stabilizer of any make, capacity from 75 to 20 KVA by supply and fixing in replacement of following items:- (a) Electronic printed circuit board of solid state including ICs, regulators, condensors, triac, transistors complete.
(b) Circuit control/trigger transformer.
(c ) Main terminal block.
(d) Dimmer
(e) Choke coils.
(f) Carbon brush.
(g) Spacer for Dimmer coils.
(h) Dimmer coils terminals.
(i) Input switch to stop over running of dimmer start motor.
(j) Servo motor with 10 Kg.cm torque.
(k) Driving gear.
(l) Bearing for dimmer coils.
(m) Terminal connections brass rod with bush.
(n) Protection alarm circuit
S&F for replacement of current transformer of ratio 100/5 Amps (Set of three) all as specified and directed.
S&F for replacement of current transformer of ratio 200/5 Amps (Set of three) all as specified and directed.
Supply and replacement of digital ampere meter of suitable range as per existing size all as specified and directed.
Supply and replacement of digital voltmeter 0-500 volts as per existing size all as specified and directed.
Supply and replacement of digital frequency meter as per existing size all as specified and directed.
Supply & toping up of new transformer oil (in sealed barrel) having dielectric strength 50KV at 2.5mm gap after initial dehydration complete all as specified. (Note: Contractor shall make a arrangement for filtration of new transformer oil so that it can used for toping after acheiving dielectric strength 50KV at 2.5 mm gap) Make: Savita/Castrol/Power oil
M&L for dehydration of transformer oil upto dielectric strength 50KV at 2.5 mm gap all as specified and as directed by engr-in-charge
M&L for replacement/repair of locking mechanism with washer of fuel tank of DG sets , fixing of new lock on DG set fuel tank by drilling holes of suitable size on tank opening and fixing of locking system consists of set of key by mean of screws tightning and fixing complete all as specified and as directed.
Taking down the existing aluminium/copper strip of any size and type from the top of blast pens/ground/equipment/bldg (roof/down conductor) and keeping in shape custody (for serviceable strips to re-use ) complete all as specified and directed.
S&F galvanized iron strip 25x4 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/welding and nut bolts jointing at all joints complete all as specified.
S&F aluminium strip 25x3 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing/jointing and nut bolts jointing at all joints complete all as specified.
S&F copper strip 20x3 mm with saddles/insulators, complete with fixing screws for roof/down conductors/main earthing lead, including bracing and nut bolts jointing at all joints complete all as specified.
S&F copper strip 32 x 6 mm earthing lead laid in trenches/GI pipe for making grid/loop of earthing pit complete all as required at site all as specified and directed by Engr-in-charge.
Refixing only of strip (serviceable strips as obtained from taking down) of any type & size but including saddles/insulators with screws for fixing complete all as specified.
S&F in replacement of saddle/insulator for strip with fixing arrangement in roof/wall of building having configuration upto G+5 for run of strips on it complete all as specified and directed.
S&F in replacement of single pointed air termination aluminium rod 12mm dia, 300mm long to fix on wall/roof/pipes with suitable MS clamp, nuts, bolts and washers as required at site complete all as specified and directed. (Note: MS/PCC work shall be measured and paid seperately).
M&L for brazing in repair work for copper strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified.
M&L for brazing in repair work for aluminum strip not exceeding 3.2 cm in length and not exceeding 6 mm in thickness complete all as specified.
S&F in replacement of GI tubing 40mm bore light grade in trenches/floor/fixed along pole for cable/earth strip protection with proper size of MS clamp, nut, bolts and washers complete all as specified and directed.
M&L for plain cement concrete in foundation 1:2:4 type B-2 with 40 mm graded stone aggregate to support the pipe/angle/as required on site including breaking of existing complete all as specified.
M&L for dismantling of PCC earth pit chamber and making PCC chamber of size as per electrical plate No. 3 of SSR-2009 Part-I with PCC (1:2:4) type B1 including RCC cover with suitable size of handle including excavation and earth work as required at site complete all as specified and directed.
S&F in replacement of RCC cover of earth pit of size as per electrical plate No. 3 of SSR-2009, Part-I complete with suitable handle complete all as specified and directed.
S&F in replacement of funnel with wire mesh suitable for each pit complete all as specified and directed.
M&L for common salt, nitrates etc for recharging of earthing pits by filling in earthing pits complete all as specified and directed. (Note:- Recharging materials shall be soluble in water and to be filled/poured in earth pit after mixing in water in appropriate quantity.)
M&L for plate earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 25x4 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC 1:2:4 type B1 using 12 mm graded crushed stone aggregate, RCC cover with handle, funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil complete all as specified.
Plate earthing complete with copper plate electrode 60 cm x 60 cm x 3 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including copper earthing strip 20x3 mm bracing/bolted with GI nuts, bolts & check nuts and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm bore GI pipe light grade for earth strip protection completeincluding provision of concrete pit in PCC 1:2:4 type B-I , using 20 mm graded crushed stone aggregate with 40 mm thick cover of RCC (1:2:4, type B-I , using 20 mm graded crushed stone aggregate) reinforced with XPM weight not less than 4 Kg /Sqm and 6mm dia bar handle ,excavation and earth work in any type of soil, returning filling in and removal of surplus soil including testing , complete all as specified and directed.
Supply and fixing in replacement MCCB 125A ,4 Pole 35Ka all as specified and directed.
Stop valves 20 mm dia, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 400 Amps, open execution type complete including making of electrical connection all as specified. Make: L&T/HPL/Havells.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 250 Amps, open execution type complete including making of electrical connection all as specified. Make: L&T /HPL/Havells.
S&F in replacement of ONLOAD changeover switch, 4 pole, 415 volts, 50 Hz, 100 Amps, open execution type complete including making of electrical connection all as specified. Make: L&T /HPL/Havells.
Note :- An amount of Rs. 45459.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
M/S BASHIR AHMAD AND SONS
nazir Ahmad Dar and sons
M/S GEE EMM MIR
M/S Sonaullah Wani and Sons
M/S ABDUL RASHID AND CO
M/S ABBAS M. ENTERPRISES
M/s Gh Qadir and Sons
MS Ghulam Hassan and Sons
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .