| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 CrAccepted-AOC | ₹10.1 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹11.5 CrRejected-Finance 16 PRATAP NAGAR CHARBHUJA RAWATBHATA RAJASTHAN 323307 | RAWATBHATA | CHITTORGARH | RAJASTHAN | 323307 | ₹11.5 Cr | L2 | Rejected-Finance Other than lowest |
| 3 | L3₹11.5 CrRejected-Finance NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU J K 181221 | JAMMU | JAMMU | JAMMU AND KASHMIR | 181221 | ₹11.5 Cr | L3 | Rejected-Finance Other than lowest |
| 4 | L4₹11.5 CrRejected-Finance | ₹11.5 Cr | L4 | Rejected-Finance Other than lowest |
| 5 | L5₹11.7 CrRejected-Finance 401 SHASTRI NAGAR JAMMU 180004 | JAMMU | JAMMU | JAMMU AND KASHMIR | 180004 | ₹11.7 Cr | L5 | Rejected-Finance Other than lowest |
Tender Value
₹14.5 Cr
EMD Value
₹10.5 L
Closing Date
11 Sept 2020, 6:00 pmClosed
CE Udhampur Zone
CE Udhampur Zone PO Garhi, Udhampur PIN-182121
ADDN/ALTN TO EXISTING OFFICERS AND JCOs/ORs MARRIED ACCOMODATION UPTO MAP SPECIFICATION AT DHAR ROAD UNDER GE (ARMY) DHAR ROAD UDHAMPUR
2020_MES_355860_1
87857-A/E8
Open Tender
Civil Works
730 days
Dhar Road Udhampur
As per NIT
9 documents required · 9 mandatory
₹3,000
GE (Army) Dhar Road Udhampur
₹10.5 L
Yes
2 Feb 2021
26 Jun 2020
15 Sept 2020
26 Jun 2020
11 Sept 2020
31 Aug 2020
Amount
Taking down chowkats or frames including shutters (without taking off shutters from the frame) not exc. 1.5 Sqm each, complete all as specified.
Taking down chowkats or frames including shutters (without taking off shutters from the frame) exc. 1.5 Sqm but n exc 4.0 sqm each, complete all as specified.
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplied and fitted in openings as per specification and drawing shown in SSR Part-II, complete all as specified.
Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side and as gap insert for top rail & bottom rail, panelling of plain colour PVC sheets to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplied & fitted in the frame at site as per specification & drawings shown in SSR Part-II, complete as specified.
Pressed steel frames of size 105mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets including necessary fixing lugs, butt hinges (100mm medium weight-03 Nos), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, complete all as specified.
Pressed steel frames of size 125mmx60mm for doors with one or more rebates fabricated out of 1.25mm thick mild steel sheets with and including necessary fixing lugs, hinges (100mm medium weight-03 Nos on each rebate), lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, complete all as specified.
Pressed steel frames of size 75mmx60mm for cupboard frames with one or more rebates fabricated out of 1.25mm thick mild steel sheets with and including necessary fixing lugs, continuous (Piano) hinges mild steel bright finished or electrogalvanised width of flaps (when open) 30mm and fixed with chowkhat by rebated and welded, lock strike plate with and including filling of hollow portion in PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate and making good the existing surface in cement mortar 1:6, complete all as specified.
2nd class hard wood (Sal/Hollock), Factory made glazed and skeleton shutters, 35mm thick, open rebated and prepared to receive glass or gauge etc., (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass/wire cloth etc., size of members of shutters as specified in clause 8.24 (a) of SSR Part-I for door shutters, supplied and fitted to chowkhat, complete all as specified.
35mm thick flush shutters, solid core construction, with block board core and plywood face panels commercial type on both sides, complete all as specified.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm fixed with stainless steel wire staples or beading etc, complete all as specified.
18mm thick water proof solid Medium Density Fibre Board prelaminated both sides (approved Colour) for doo/cupboard shetters/shelves and partition of required size fabricated by jointing and fitted with necessary arragement as in cup board cup board back side, partition and shelves etc fixed with each other using solvent cement adhesive and stainless steel screws. The edges of board visible and shutters shall be lipped with 18mm wide x 1mm thick edges leaping tapes as per manufacturer instructions, complete all as specified and as directed.
100mm long aluminium anodised butt hinges, type B-21 with galvanised mild steel screws, complete all as specified.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long (ISI marked), complete all as specified.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 125mm long (ISI marked), complete all as specified.
Aluminium anodised, barrel tower bolt of extruded section and fixed, 200mm long (ISI marked), complete all as specified.
Aluminium handle, cast type, anodised, 100mm long (ISI marked), complete all as specified.
Aluminium handle, cast type, anodised, 125mm long (ISI marked), complete all as specified.
Aluminium handle, cast type, anodised, 150mm long (ISI marked), complete all as specified.
Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) with and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy and fixed, 300mm long, complete all as specified.
Door eye viewer, viewing angle 180 degree, mounting diameter 14mm, total size 4 x 2.5cm (LxD) with good quality glass eye lens, , brass chromium plated fixed in position for door shutters, complete all as specified & directed.
Door seal brush (Aluminium plate with nylon brush) of required length for any size of doors, fixed with stainless steel screw, complete all as specified and as directed. Make:- Harrison or equivalent
Floor door stopper of aluminium alloy body and tongue, anodised, overall length of cover plate 100mm, complete all as specifed.
300mm ordinary rat tail rod pattern door spring including roller and roller plate of mild steel, fixed to chowkhats/welded to chowkhats as directed, complete all as specified.
100mm size hasp & staple, aluminium, safety type, including bolt to hinge plate and fixed with screws, complete all as specified.
Stainless steel pipe of 20mm dia, heavy grade with and including fixing brackets, stops, rollers etc., in cupboards, complete all specified & directed.
Powder coated Aluminium windows/vents complete all as specified in particular specification and as shown on drawings for various sizes and pattern with following powder coated aluminium sections :- Notes:- A. The rates quoted for powder coated aluminium sections shall be deemed to include the following:- (i) The aluminium section and fittings shall be Pure polyster powder coated of thickness not less than 50 microns. (ii) Rubber gasket for fixing glass to windows/vent shutters. (iii) Fixing of window in openings with and including min 75x10 GI screws all around @ 300C/C (Min 2 Nos on one side) with PVC RAWL PLUGS/Sleeves. (iv) Rollers, concealed lock cum handle & other fittings for sliding shutters shall be provided as per manufactures instructions and approved by GE. (v) Silicone sealant shall be applied on internal as well as external periphery of window and masonry joint to avoid water seepage. (vi) All other sundries all as per manufacturer instructions and as directed. B. The rates quoted for powder coated sections shall exclude the cost following and shall be paid seerately under respective items of Sch`A'/BOQ:- (i) Glass and wire mesh (ii) 40x40x3 aluminum angle provided on all corners of the windows. (c) Aluminum-U-channel shall be provided for fixing of wire mesh. (d) Powder coated aluminium handles and hinges for fixing of openable shutters C. OTHER (i) No allowance for wastage/overlaps shall be considered for payment. (ii) Range of dimension of opening size has been mentioned. The same shall be fixed as per measurements of opening of windows as per site requirement by the GE/EIC during execution of work. (iii) Powder coated aluminium section shall be provided all as shown on drawings and as directed.
(a) THREE TRACK powder coated aluminium section as in window/vents frame for sliding shutters.
(b) Powder coated aluminium sections as in window/vents frame for openable shutters.
(c) Powder coated aluminium sections as in sliding window shutters.
(d) Powder coated aluminium sections as in openable window shutters.
(e) Powder coated aluminium tower bolts 75mm long and fixed.
(f) Powder coated aluminium butt hinges 75mm and fixed.
(g) Powder coated aluminium handle 75mm and fixed.
(h) Powder coated aluminium plate type II Gate and shutter, hook and eyes 100mm and fixed.
Sheet glass 4 mm thick ordinary quality for fixing to aluminium windows with all necessary fixing arrangement, complete all as specified.
Demolition of cement concrete unreinforced of any description in any position not otherwise specifically provided for, complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc., complete all as specified.
Brushing neat cement slurry with 3.0Kg of cement per square metre, complete all as specifed & directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing), racking out joints, hacking for key and scrubbing and removing rubbish off the premises, complete all as specified.
Non-skid rectfied jointless light coloured group ceramic tiles 7 to 8mm thick (square/rectangular) PEI Grade-1, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry at 3kg/sqm and pointed in coloured cement to match, laid over and including 10mm thick bedding layer in cement mortar 1:4, complete all as specified.
Non-skid rectfied jointless light coloured group ceramic tiles 7 to 8mm thick (square/rectangular) PEI Grade-1, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry at 3kg/sqm and pointed in coloured cement to match, laid over and including 10mm thick plastering in cement mortar 1:4, complete all as specified.
Glazed rectfied jointless light coloured group ceramic tiles, PEI Grade-0 of size 300mmx450mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, complete all as specified.
Pre-Polished kota stone as in flooring/treads of stair,18- 20 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 20mm screed layer in cement mortar 1:3, complete all as specified. Notes:- 1. Single piece kota stone shall be provided in treads of stair as per site requirement. 2. Slabs of not less than 550mm x550 shall be provided in all other places of flooring.
Pre-polished kota stone, 18-20 mm thick as in vertical surfaces such as skirting/dado/riser of steps etc., laid and jointed with grey cement slurry mixed with pigment to match the shade of slab, laid over and including 10mm thick plastering in cement mortar 1:3, complete all as specified. Notes:- 1. Single piece kota stone shall be provided in riser of stairs as per site requirement.
25mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate as in levelling course, rough finished, complete all as specified.
Prepration of new wooden surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified.
PCC 1:2:4 (nominal mix), type B-2 using 40mm graded crushed stone aggregate as in foundations, filling, mass concrete, complete all as specified & directed.
50mm thick PCC 1:3:6, nominal mix, type C1, using 20mm graded crushed stone aggregate as in plinth protection, laid in alternate bays (not exceeding 2 Sqm each) surface finished even and fair without using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising of one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified.
Providing precast cement concrete 1:2:4 type B0 louvres and jallies, 35mm thick (measured solid), including all mouldings but excluding frame set in cement mortar 1:4, complete all as specified and as directed.
Demolition of reinforced cement concrete of any description in any position not otherwise specifically provided for such as kitchen chimney, chajja, shelves, OH tanks etc. (Reinforcement cut as required to facilitate demolition), complete all as specified and as directed.
RCC 1:2:4, nominal mix, using 20mm graded crushed stone aggregate as in chajjas, shelves and the like, complete all as specified & directed. Note: Reinfocement shall be measured and paid for separtely.
RCC 1:2:4, nominal mix, using 20mm graded crushed stone aggregate as in as in beams, cantilevers, bressummers, lintels over 1.5m span, complete all as specified. Note: Reinfocement shall be measured and paid for separtely.
Precast RCC 1:2:4, nominal mix, using 20mm graded crushed stone aggregate as in landings, cover slabs (for manhole etc.), shelves, chullah hoods, chajja and similar articals with plain faces, set in cement mortar 1:4 complete all as specified & directed. Note: Reinfocement shall be measured and paid for separtely.
Form work to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete, complete all as specified & directed.
Form work to sides and soffits of floor or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc alo splays between floors and beamsfor rough finished surfaces of concrete, complete all as specified & directed.
Form work to edges of concrete flats, break in floors, openings in concrete walls, floor and roof and sides of RCC/PCC bands in walls, horizontal or sloping, sides of window cill, concrete railing and similar work exc. 5cm and nexc 10cm wide for rough finished surfaces of concrete, complete all as specified & directed.
Mild steel TMT bars 10mm dia & over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500D, complete all as specified& directed.
Mild steel TMT bars 6 to 8mm dia , cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, conforming to grade Fe-500D, complete all as specified& directed.
Taking down existing roof treatment of any description and any type and in any position and removing the deberis from site outside MD land, complete all as specified and as directed.
15mm thick plastering in cement mortar 1:4 MIXED WITH WATER PROOFING COMPOUND AS PER MANUFACTURER INSTRUCTIONS) on roof surfaces after applying cement slurry @ 3kg/Sqm, surface finished even and smooth without using extra cement, complete all as specified. Note: WPC shall be measured and paid for seperately under respective item
Supply only liquid water proofing compound, complete all as specified.
40mm thick PCC 1:2:4 nominal mix, type B-0, using 12.5mm graded stone aggregate in two layers of 20mm each MIXED WITH WATER PROOFING COMPOUND AS PER MANUFACTURER INSTRUCTIONS) on roof surfaces, surface finished even and smooth without using extra cement, complete all as specified. Note: WPC shall be measured and paid for seperately under respective item
ROOF TRATETMENT FOR NON-ACCESSIBLE ROOF :- Priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 Ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20Kg/Sqm and thereafter proviging polmeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm, having a centre core of 90 micron high molecular density polyethlene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/sqm, Top surfaces of roof after carrying out treatment as specified here-in-above shall be provided with 2 coats of aluminium paint over a coat of primer as per manufacturer’s instructions, complete all as specified & directed.
ROOF TRATETMENT FOR ACCESSIBLE ROOF :- Priming the roof surface with bituminous primer conforming to IS-3384 @ 0.30 Ltrs/Sqm and applying a coat of hot blown 85/25 grade bitumen conforming to IS-702 @ 1.20Kg/Sqm and thereafter providing polmeric water proofing membrane (five layered) of weight not less than 3 Kg/Sqm, having a centre core of 90 micron high molecular density polyethlene film followed by another coat of semi hot blown 85/25 grade bitumen @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.50 Kg/sqm, complete all as specified & directed.
Taking down old PCC tiles from roof and removing bedding at any position and removing the deberis outside the MD land, complete all as specified and as directed.
Cement concrete tiles, coloured, machine pressed, factory made of size 30cmx30cm, 20mm thick, with grey cement and pigment, set, jointed and pointed in neat cement slurry, laid over and including 15mm thick screed layer in cement mortar 1:4 over roofs, complete all as specified.
PCC 1:2:4 (nominal mix), type B-0 using 12.5mm graded crushed stone aggregate MIXED WITH WATER PROOFING COMPOUND AS PER MANUFACTURER INSTRUCTIONS as in roof kerbs/benching or mud stops, rounded or chamfered on edges including necessary formwork, complete all as specified & directed. Note: WPC shall be measured and paid for seperately under respective item
Chicken wire mesh of size 12.5 mm and wire dia 0.51 mm (24 SWG) hexagonal construction, stretched firmly for roof treatment, complete all as specified.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:6, complete all as specified.
Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4 in HALF BRICK WALL, complete all as specified.
RCC 1:2:4, nominal mix, using 20mm graded crushed stone aggregate as in slab, complete all as specified & directed. Note: Reinfocement shall be measured and paid for separtely.
Cutting holes through stone wall exc. half brick and not exc. 1 brick built in cement mortar for inserting hold fast and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required
WATER PROOFING TREATMENT TO FLOOR AND VERTICAL SURFACES OF SUNKEN PORTION COMPRISING THE FOLLOWING:- (a) Demolition of floor and lime/cement concrete etc, removing all loose particles alongwith existing water proofing treatment (any number of layers) and cleaning by brushing with wire brushes to remove all dirt and cleaning the surface with water. (b) Providing 60cm long, 40mm dia GI medium grade spout pipe by making holes and making the surface good . (c) Brushing neat cement slurry @ 1.2 Kg/sqm duly blended with and including water proofing compound. (d) Rendering 15mm thick in cement mortar 1:3 mixed with and including Water proofing compound on sunken surface including walls. The corner of sunken portion shall be rounded in concave shape and adequate slope shall be made during plastering to accomodate sump pipe and curing the sunken potion with water minimum for 48 hours by ponding. (e) Apply a coat of bituminous primer conforming to IS 3384 @ 0.70 lit per sqm. After dryinh of primer apply a coat of hot blown 85/25 grade bitumen @ 1.2 Kg/Sqm. (f) Applying self adhesive type APP (Atactic Poly-propylene polymer) modified membranes, five layered, 3mm thick weighing not less than 1.5 Kg/Sqm, having a centre core of polyester non-woven mat (FP) reinforcement. (g) PCC 1:7:12 for filling of sunken portion after concealing all membrane and sealing all joints with sealing compound of MC Bouchemie/Roofex/Forre/Choksy/Dr Beck & Coty/FOSROC.
15mm thick plastering in cement mortar 1:4 on fair faces of brick surfaces or concrete surfaces, MIXED WITH WATER PROOFING COMPOUND AS PER MANUFACTURER INSTRUCTIONS surface finished even and smooth without using extra cement, complete all as specified. Note: WPC shall be measured and paid for seperately under respective item)
15mm thick plastering in cement mortar 1:4 in PATCHES NOT EXC 3SQM EACH on fair faces of brick surfaces or concrete surfaces, MIXED WITH WATER PROOFING COMPOUND AS PER MANUFACTURER INSTRUCTIONS surface finished even and smooth without using extra cement, complete all as specified. Note: WPC shall be measured and paid for seperately under respective item)
Complete removal of existing treatment from internal/external wall surfaces including scraping, sand papering or by using mechanical sander, complete all as specified and as directed.
Preparation of plastered or unplastered surfaces of walls by comp, roof border, drops, fins, chajja/roof facia, columns etc and applying two coats of exterior emulsion paint over a coat of acrylic primer, complete all as specified.
10mm thick plastering in cement mortar 1:6 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified.
10mm thick plastering in cement mortar 1:6 in PATCHES NOT EXC 3SQM EACH on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified.
Rough cast plaster average thickness 15mm thick in cement mortar 1:4 as preparatory coat for undulations of surface where required, complete all as specified.
Add/deduct for evey 5mm average thickness over/under of 15mm th rough cast plaster , complete all as specified.
Preparation of new plastered surfaces of wall and applying two coats of Acrylic distemper over a coat of Alkali resistant primer, tint and shade as approved by the GE, complete all as specified.
Preparation of plastered surfaces of wall by applying 2mm thick wall care putty in two coats and smoothening the surfaces with sand paper/mechanised sanding etc preparatory to paint, complete all as specified and as directed.
Preparation of new plastered surfaces of wall and applying three coats of white wash, complete all as specified.
5mm thick plastering in cement mortar 1:3 on concrete surfaces of ceiling, fascia, chajja, roof projection, surface finished even and smooth without using extra cement, complete all as specified.
Complete removal of existing treatment from ceiling surfaces including scraping, sand papering or by using mechanical sander, complete all as specified and as directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified.
Vetrified ceramic coloured tiles, light shade 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match, laid over and including 10mm thick bedding layer in cement mortar 1:4, complete all as specified.
Vetrified ceramic coloured tiles, light shade 10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm, as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, complete all as specified.
Taking down cement plaster/terrazo plaster on brick or stone surfaces etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified.
Dismantling boarding of any description, fixed in any position with nails including cover fillets, complete all as specified.
18mm thick water proof solid MDF Board prelaminated both sides of approved shade fitted with necessary arrangement as in kitchen cabinet back sides, partition, shutters and shelves, etc., fixed with solvent cement adhesive and stainless steel screws and providing 1mm thick PVC lipping to exposed edges, complete all as specified and as directed.
Extruded brass handle, fancy type as approved by the GE, polished, 125mm long (ISI marked), complete all as specified.
Continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30mm, complete all as specified.
Magnetic catcher suitable for kitchen cabinet shutters, complete all as specified.
Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc., laid, bedded and pointed in any mortar, complete all as specified.
18-20mm thick Granite (Zed-Black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over 15mm thick in cement mortar (1:4) bedding including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, with and including providing nosing to edges of slab and drilling of hole for gas pipe using mechanical method, complete all as specified & directed. Note: Granite stone slab shall be in single piece to fit.
Stainless steel plate rack of size 750mm x 900mm x250mm as per sample kept in GE’s office of minimum thickness of strip not less than 0.50mm, fixed in repairs, complete all as directed.
Stainless steel plate rack of size 775mm x 900mm x230mm as per sample kept in GE’s office of minimum thickness of strip not less than 0.50mm, fixed in repairs, complete all as directed.
Sink made of stainless steel sheet not less than 0.80mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever cast iron bracket, connecting union etc. and overall size 495x420mm with bowl size 410x330x160mm with and including stainless steel heavy duty waste coupling and PVC waste collapsible pipe, fixed in repairs, complete all as specified & directed.
Stainless steel sink with drainage board made of stainless steel sheet not less than 0.80mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever cast iron bracket, connecting union etc. and overall size 915x460mm with bowl size 410x330x160mm with and including stainless steel heavy duty waste coupling and PVC waste collapsible pipe, fixed in repairs, complete all as specified & directed.
Stainless steel sink with drainage board made of stainless steel sheet not less than 0.80mm thick for kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever cast iron bracket, connecting union etc. and overall size 1040x510mm with bowl size 510x405x203mm with and including stainless steel heavy duty waste coupling and PVC waste collapsible pipe, fixed in repairs, complete all as specified & directed.
Sink mixer with regular spout wall mounted with connecting legs and wall flanges and including all necessar fitting, complete all as specified. Make: Jaquar Cat Part No. CON 319KN or equivalent in Make as per Appx `E' to Particular specification.
Sink mixer with regular spout wall mounted with connecting legs and wall flanges and including all necessar fitting, complete all as specified. Make: ESS ESS Cat Part No. EC-12 or equivalent in Make as per Appx `E' to Particular specification.
Bib tap, 15mm bore, fancy type, , chromium plated with wall flange, cast copper alloy with crutch or butterfly handle screwed down, screwed for iron pipe or for brass ferrule, fixed in repairs, complete all as specified.
Soap tray brass chromium plated and fixed to plugs on wall with brass screws, complete all as specified. Make: Jaquar Cat Part No. ACN 1131N or equivalent in Make as per Appx `E' to Particular specification.
Soap tray brass chromium plated and fixed to plugs on wall with brass screws, complete all as specified. Make: ESS ESS Cat Part No. AC 703 or equivalent in Make as per Appx `E' to Particular specification.
PVC (SWR) floor trap, plain with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified.
PVC (SWR) multi floor trap with grating including jointing to waste pipe with solvent cement, dia of outlet 75mm, complete all as specified.
Wall mixer with provision for overhead showes with 115mm long bend pipe on upper side, connecting legs and wall flanges, complete all as specified and directed. Make: Jaquar Cat Part No. CON 273KNUPR or equivalent in Make as per Appx `E' to Particular specification.
Wall mixer with provision for overhead showes with 115mm long bend pipe on upper side, connecting legs and wall flanges, complete all as specified and directed. Make: ESS ESS Cat Part No. EC-10 or equivalent in Make as per Appx `E' to Particular specification.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified. Make: Jaquar Cat Part No.ACN 1111SM or equivalent in Make as per Appx `E' to Particular specification.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified. Make: ESS ESS Cat Part No.AC 701 or equivalent in Make as per Appx `E' to Particular specification.
Towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs, complete all as specified. Make: ESS ESS Cat Part No.AC 701 or equivalent in Make as per Appx `E' to Particular specification.
Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified. Make: Jaquar Cat Part No. ACN 1121N or equivalent in Make as per Appx `E' to Particular specification.
Towel ring brass chromium plated, fixed with brass screws and plugs, complete all as specified. Make: ESS ESS Cat Part No. AC702 or equivalent in Make as per Appx `E' to Particular specification.
Corner glass shelf 200mm (brass brackets), fixed with brass screws and plugs, complete all as specified. Make: Jaquar Cat Part No. ACN 1173 or equivalent in Make as per Appx `E' to Particular specification.
Corner glass shelf 200mm (brass brackets), fixed with brass screws and plugs, complete all as specified. Make: ESS ESS Cat Part No. AC 207A or equivalent in Make as per Appx `E' to Particular specification.
Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints, fixed in repairs, complete all as specified. Make: ESS ESS Cat Part No. RF 202 for Shower and Cat Part No. SA-105 for shower arm or equivalent in Make as per Appx `E' to Particular specification.
Brass chromium plated shower rose of 200mm size with arm and with or without swivel joints, complete all as specified. Make: Jaquar Cat Part No. OHS 1779 for shower and SHA 49483 for arm or equivalent in Make as per Appx `E' to Particular specification.
Angle valve with wall flange, 15mm bore, fancy type, chromium plated with long shank and cup, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repair, complete all as specified. Make: Jaquar Cat Part No. CON-059KN or equivalent in Make as per Appx `E' to Particular specification.
Angle valve with wall flange, 15mm bore, fancy type, chromium plated with long shank and cup, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., fixed in repair, complete all as specified. Make: ESS ESS Cat Part No. T-112B or equivalent in Make as per Appx `E' to Particular specification.
Angle valve with wall flange, 15mm bore, fancy type, chromium plated with long shank and cup, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, both ends screwed for iron pipe or for union etc., complete all as specified. Make: ESS ESS Cat Part No. T-112B or equivalent in Make as per Appx `E' to Particular specification.
PVC connections 15mm size with Brass nuts of length 600mm, fixed in repairs, complete all as specified. Make: Prayag Cat Part No. BCT-04 or equivalent in Make as per Appx `E' to Particular specification.
PVC connections 15mm size with Brass nuts of length 600mm, complete all as specified. Make: Prayag Cat Part No. BCT-04 or equivalent in Make as per Appx `E' to Particular specification.
Vitreous China, wash hand basin, counter top, white, of size 530mmx445mmx195mm including brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper with and including PVC collapsible waste pipe of suitable length, fixed in repairs, complete all as specified. Make: Jaquar Cat Part No. ECS-WHT-601 or equivalent in Make as per Appx `E' to Particular specification.
Vitreous China, wash hand basin, flat back white of size 450mmx350mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand with and including PVC collapsible waste pipe of suitable length, fixed in repairs, complete all as specified. Make: Cera Cat Part No. S 2040102 or equivalent in Make as per Appx `E' to Particular specification.
Vitreous China, wash hand basin, flat back white of size 515mmx410mm including brackets, brass CP waste coupling 32mm dia with long screwed shank and fly nuts,32mm dia, chain and plug, porcelain stopper including cutting for and pinning in ends of brackets or erecting stand with and including PVC collapsible waste pipe of suitable length, complete all as specified. Make: Cera Cat Part No. S 2040121 or equivalent in Make as per Appx `E' to Particular specification.
Chrromium plated brass Centre hole mixer without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB, complete all as specified. Make: Jaquar Cat Part No. CON-167KNV or equivalent in Make as per Appx `E' to Particular specification.
Chrromium plated brass Centre hole mixer without pop up waste system 15mm bore for mixing hot and cold water screwed down for iron pipe for WHB, complete all as specified. Make: ESS ESS Cat Part No. T-118 or equivalent in Make as per Appx `E' to Particular specification.
Mirror cabinet PTMT of 400mmx500mm with magnetic locking arrangement fixed with and including wooden plugs with chromium plated brass screws, complete all as specified. Make: Prayag Cat Part No. 554 or equivalent in Make as per Appx `E' to Particular specification.
One piece closet with bowl for cupled WC with PP soft seat cover, hinges fixing accessories and accessories set of size 360mmx680mmx765mm, strap 220mm cistern with cistern fittings and necessary fixing fittings complete, fixed in repairs, complete all as specified. Make: Jaquar Cat Part No. CNS-WHT-755SS or equivalent in Make as per Appx `E' to Particular specification.
Vitreous Chinaware squatting pan, orissa pattern size 580mm x 440mm with integral foot rests, white, with cast iron ‘P’ or ‘S’ trap, front or back inlet, including provision of lime concrete, making connections to trap and to flush pipe etc. and making good to floors, fixed in repairs, complete all as specified. Make: Cera Cat Part No. Calina S 3010102 or equivalent in Make as per Appx `E' to Particular specification.
PVC valveless, with top button double action type,syphonic action type flushing cistern, 10 litres capacity, low level, white with inlet, ball valve, float and handle, 32 mm dia PVC long bend flush pipe, fixed in repairs, complete all as specified. ake: Prayag Cat Part No. 504 or equivalent in Make as per Appx `E' to Particular specification.
Peg set of six, stainless steel of suitable length, complete all as specified. Make: Prayag Cat Part No. BEA 30 or equivalent in Make as per Appx `E' to Particular specification.
Toilet paper holder,stainless steel, fixed with and including chromium plated brass screws and and wooden/plastic cleats on walls, complete all as specified. Make: Jaquar Cat Part No. AKP 35753PS or equivalent in Make as per Appx `E' to Particular specification.
Health faucet brass chromium plated with 8mm dia 1.2 mtr long flexible pipe and wall hook fixed with brass chromium plated screws, complete all as specified. Make: Jaquar Cat Part No. ALD CHR-573 or equivalent in Make as per Appx `E' to Particular specification.
Taking up or down steel pipe 15mm bore including cleaning for refixing, complete all as specifed.
GI water tubing, medium grade, 15mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified.
Refixing old GI water tubing, medium grade, 15mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified.
Taking up or down steel pipe 20mm bore including cleaning for refixing, complete all as specifed.
GI water tubing, medium grade, 20mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified.
Refixing old GI water tubing, medium grade, 20mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified.
GI water tubing, medium grade, 25mm bore with all fittings, fixed complete to walls and ceilings or laid in floors, complete all as specified.
25mm dia fancy type PVC coated on MS pipe coloured curtain rod with and including brackets and knob at both ends as per site requirement including taking down old existing PVC conduit pipes with accessories, complete all as specified.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and or reveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe-290 grade-E-165, complete all as specified.
Mild steel Framed work as in safety doors fabricated out of mild steel hollow sections of sheet thickness not less than 1.6mm thick, MS square bars or other section with, rails, braces, sliding door bolt fabricated out of 16mm Ms round bar, staple etc with and including provn for fixing of wire mesh, complete and fixed to mild steel pressed chowkhats, complete all as specified and as directed. Note: (ii) Sketch drawing for safety door shall be provided by the GE during execution of work. (ii) Wire mesh shall be measured and paid for seperately
Expanded metal, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanized steel staples supplied and fixed complete to wood or steel members, weight exc 4 Kg per Sqm, complete all as specifed & directed.
Prepration of new or previously untreated steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified.
Rotationally moulded polyethylene water storage tank (cylindrical vertical), tripple layer construction with threaded tank cover, white colour, hoisted & fixed in position of capacity 500 ltrs including taking down old unserviceable tank and removing from site, complete all as specified.
Rotationally moulded polyethylene water storage tank (cylindrical vertical), tripple layer construction with threaded tank cover, white colour, hoisted & fixed in position of capacity 1000 ltrs including taking down old unserviceable tank and removing from site, complete all as specified.
Dismantling of water tanks of capacity n. exc 500 litres and refixing in same postion after cleaning the tank to the entire satisfaction of Engr-in-Charge, complete all as specified.
Dismantling of water tanks of capacity n. exc 1000 litres and refixing in same postion after cleaning the tank to the entire satisfaction of Engr-in-Charge, complete all as specified.
Gun-metal, globe or gate valves of 20mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified.
Gun-metal, globe or gate valves of 20mm dia, with iron wheel head, screwed both ends for iron pipe, fixed in repairs, complete all as specified.
Gun-metal, globe or gate valves of 25mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified.
Gun-metal, globe or gate valves of 25mm dia, with iron wheel head, screwed both ends for iron pipe, fixed in repairs, complete all as specified.
20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) and fixed, complete all as specified and as directed.
PVC tank nipple 20mm suitable for HDPE water tank min wt 45gm and fixed, complete all as specified and as directed.
PVC tank nipple 25mm suitable for HDPE water tank min wt 65gm and fixed as in overflow pipe, complete all as specified and as directed.
Cutting chases in brick wall not exc 10cm girth for concealed water tubing and making good the surfaces in cement mortar 1:3, complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering, complete all as specified.
Dismantling wall & ceiling board (fibre, pulp, insulation etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets, complete all as specified.
Pre-painted galvatume aluminum zinc coating GI based profile steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified & directed.
False ceiling with Gypsum based ceiling tiles and frame work (with aluminium foil on one side) of size 595mm x 595mm of thickness not less than 9mm including with GI powder coated frame angle/tee grid frame work for ceiling with following specifications:- (a) Bottom Tee- 25mm x 25mm, 1.0mm thickness (b) Cross Tee- 25mm x 25mm, 1.0mm thickness (c) Wall angle- 25mm x 25mm, 1.00mm thickness (d) 1.imm dia GI wire suspenders alonwith adjustable clamps to maintain levelling in cluding fixing to ceiling fasteners as per manufacturers instructions. (e) Rest all as directed by the GE Make: Vinyl TOUCH of LaGyp or equivalent in Make as per Appx `E' to Particular specification.
Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, hoes, bends, swan-necks, etc., including cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories), complete all as specifed.
PVC (SWR) pipes, 110mm dia, single socketed, in any length with rubber ring joints and epoxy adhesive, fixed to walls, complete all as specified & directed.
Dismantling of cast iron or reinforced concrete drain pipes, jointed in cement mortar in any position, internal dia of pipe upto 100mm, complete all as specified & directed.
PVC (SWR) pipes, 75mm dia, single socketed, in any length with rubber ring joints and epoxy adhesive, fixed to walls, complete all as specified & directed.
110mm bore PVC (SWR) bends any radius and fixed with epoxy adhesive, complete all as specified.
75mm bore PVC (SWR) bends any radius and fixed with epoxy adhesive, complete all as specified.
110mm bore PVC (SWR) junction single (Single T ) equal or unequal and fixed with epoxy adhesive, complete all as specified.
75mm bore PVC (SWR) junction single (Single T ) equal or unequal and fixed with epoxy adhesive, complete all as specified.
110mm bore PVC (SWR) junction double (double T ) equal or unequal and fixed with epoxy adhesive, complete all as specified.
75mm bore PVC (SWR) junction double (double T ) equal or unequal and fixed with epoxy adhesive, complete all as specified.
Add to Srl item No 162 and 166 if provided with oval access door, complete all as specified.
Add to Srl item No 163 and 167 if provided with oval access door, complete all as specified.
PVC (SWR) vent cowl of size 110mm bore and fixed with epoxy adhesive, complete all as specified.
Prepration of old decorated steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
Prepration of old wooden or wood based surfaces of any description n exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
Removal of vegetation from roots etc on wall/roof area not exceeding 1 Sqm each by applying suitable chemical and making good the disturbed surface by grouting the holes and matching the suface by 15mm thick plastering in cement mortar 1:3, complete all as specified and as directed.
Prepration of old wooden or wood based surfaces of any description exc 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified.
Providing of anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron., complete all as specified.
Anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors, complete all as specified.
Anti termite treatment of voids in masonry using chemical emulsion (Cholorophyrus 20% EC) one litre per hole, at 300mm intervals including drilling holes at 45 degree and replugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors, complete all as specified. Notes for Srl item 176 to 178 :- (a) Anti termite treatment shall be got done through an approved specialized agency which is a member of Indian Pest Control Association holding valid license as per Clause 13 of Insecticides Act 1968. Persons employed to do the Antitermite treatment shall be qualified as per Rule 10 of the rules framed under the Insecticides Rule 1971. The work shall be carried out through any of the agency as mentioned in list of makes attached hereinafter. (b) Anti termite treatment shall be carried out with emulsion as mentioned in Appx-`A’ of makes attached hereinafter shall be purchased directly from manufacturer or his authorized agent. Purchase vouchers shall be produced to the GE for verification. (c) Cholorophyrus 20% EC Chemicals brought to site in sealed containers bearing ISI certification marks shall only be permitted to be used.
Grinding and polishing to existing Kota stone flooring to the entire satisfaction of GE, complete all as specified and as directed.
Welding in repairs not exc 2.5cm in length to metal of any thickness to be welded, complete all as specified and as directed.
0.56mm thick plain aluminium sheet alloy 31000 H4, in ridges, hips, valley gutters, drip and straight flashings, complete all as specified and as directed.
20-25mm thick pre-formed filler board for expansion joints, complete all as specified and as directed.
Providing RCC nominal mix 1:2:4 including necessary formwork and providing 5mm thick plaster in cement mortar 1:3 for RCC projected portion as in dwarfs, facia, fin etc including demolition of existing and providing TMT bar if required, complete all as specified and as directed. Note: Length of dwarfs, facia, fin etc. shall be measured irrespective of any thickness and height for payment purpose.
Repair of RCC slab, columns, beams by removing of old portion of concrete and cleaning/brushing and removing of loose concrete and applying required cement slurry @ 3.5 Kg/Sqm, making good with cement concrete nominal mix 1:1.5:3 including necessary formwork and providing 5mm thick plaster in cement mortar 1:4 to match the finished surface, complete all as specified and as directed.
Demolition of cement concrete, un-reinforced in ground floors and paving not exceeding 15cm thickness (below or above ground level), complete all as specified.
75mm thick PCC 1:4:8 (nominal mix), type D-2 using 40mm graded crushed stone aggregate as in sub base of interlockin tiles, complete all as specified & directed.
Machine pressed precast concrete interlocking paver block, shape and size as approved by the GE, confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment laid over and including 25mm thick sand cushioning, complete all as specified and as directed.
Factory made Pre-cast cement concrete block type B1, 1:2:4 as in kerb stone made to shape as directed, exc. 10 cm in width and setting in mortar 1:4, complete all as specified and as directed.
PVC (SWR) pipes, 75mm dia, single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified & directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in any type of soil, complete all as specified & directed.
Excavation in trenches not exc. 1.5m wide and not exc. 1.5m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables/pipes etc. n exc 10 sqm on plan and n exc 1.5m in depth in any type of soil and getting out, complete all as specified and as directed.
Excavation in trenches not exc. 1.5m wide and exc. 1.5m but n exc 3m in depth; for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10 sqm on plan and n exc 1.5m in depth in any type of soil and getting out, complete all as specified and as directed.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm, complete all as specifed.
Removing excavated material (spoil) to a distance not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point, complete all as specified.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete)set in cement mortar and laid in trenches, internal dia of pipe 150mm, complete all as specifed & directed.
Salt-glazed stoneware drain pipe, internal dia of pipe 150mm, laid in trenches and jointed and tested, complete all as specified.
Reinforced concrete pipes, class NP2, laid & jointed complete with collars, bore of pipe 300mm, complete all as specified & directed.
Concrete bed to 150mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret M-10 (Nominal mix) type C-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Concrete bed to 300mm bore drain pipes including packing under, and haunching against the sides of pipes after they are laid in cement concret M-10 (Nominal mix) type C-2 using 40mm graded stone aggregate, and tested, complete all as specified & directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching, internal dia of pipe 150mm, complete all as specified.
PCC 1:2:4, nominal mix, type B2, using 40mm graded crushed stone aggregate as in surface channel and drains including necessary formwork, complete all as specified.
Extra for forming fair finished drain or channel in PCC 1:2:4 type B0, 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified.
Add or deduct for Extra for forming fair finished drain or channel in PCC 1:2:4 type B0 for each 25mm girth or part thereof over or under 30cm in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc., complete all as specified.
Construction of Septic tank for 100 Users (Brick Construction), complete all as specified and as shown on drawings No. CEUZ/TD/1202/03 sheet 1/2 & 2/2 dated 14/10/2014 and 11/05/2007 respectively..
Construction of soakage well 1.80 m dia and 4.5m deep (Internal dimensions) (Brick construction), complete all as specified and as shown on drawing No . CEUZ/TD/1202/03 sheet 1/2 & 2/2 dated 14/10/2014 and 11/05/2007 respectively.
PCC 1:2:4 , nominal mix, type B-1, using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, coping, bed plates, hold fast and the like including weathering, slightly rounded or chamfered angles and throating including necessary form work, complete all as specified.
15mm thick plastering in cement mortar 1:4 on other than fair faces of brick surfaces, finished even and smooth without using extra cement, complete all as specified.
Removing all loose scale and corrosion deposits of the exposed corrugated steel including surface preparation. Corrugated steel should be cleaned al around including the back of exposed steel bars and removing all the loose concrete around the reinforcement with the clearance as recommended by the manufacturer of rust remover, then applying rust remover with brush by complete wetting the rusted material surface by rust remover & leaving for 24 Hrs and thereafter surface preparation of coated bars and applying 2nd coat of the rust remover & leaving the same for the specific period as per manufacturer's instructions and further again preparing and cleaning the steel surfaces for treatment, complete al as specified and directed by the Engr-in-Charge, Make : Sika/ Rustoff 100/fosroc Rebacklens/BASF Emaco S420 Sika Rustoff 100/fosroc Rebacklens/BASF Emaco S420.
Rebaring of Mild steel TMT bars 8mm to 20mm dia (as per existing provn at site) of required length with Sika Anchor Fix&3+/ fosroc lockfix/equivalent in BASF wherever required in RCC members including power drilling, cleaning of holes then rebar should be inserted in the holes that should b filled with epoxy as mentioned above to ensure the bond as per manufacture instructions, complete for the following diameter of bars as per site requirement & as directed by Engr-In-Charge. (Where ever required necessary welding of rebar’s shall also be done with main reinforcement without any extra cost).
CORROSION RESISTANCE COATING: M&L for applying passivator/anti corrosion coating to the prepared surface of item 210 above. The material shall be cement base polymer modified coating for corrosion protection and shall be applied as per manufacture instructions. Make: Sika Armatec 108/Fosroc Nito cote AP-35/equivalent in BASF.
Preparation of old RCC/concrete surface and applying a coat of two components solvent free epoxy bonding agent using brush after cleaning of surface from all dust or laitance all as per manufacturer instructions and as directed by Engr-In-Charge. Mak: Sika 32Lp/Fosroc Nitobond Ep/equivalent in BASF. Note : The new concrete surface shall be placed within the open times as specified the manufacturer to ensure maximum bonding. .
PATCH WORK FOR INSUFFICIENT CONCRETE COVER OF SOFFIT AREA OF CONCRETE. Providing and applying ready to use single component high strength polymer modified cementitious repair mortar 25 mm thick with water/powder ratio as specified by manufacturer so as to achieve the following parameter:- 28 days compressive strength >=50N/mm2 Flexture strength at 28 days>= 5N mm2. Make: Sikatop 122 HS/Fosroc Nito mortars/or equivalent in BASF. .
CURING COMPOUND Applying high efficiency water based film forming curing compound over the fresh concrete/cementitious surface to form a continuous non-penetrating coating, providing a barrier to moisture moss ensuring more efficient cement hydration improved durability and reduced shrinkage. The compound shall be applied by sprayer only as per manufacturer instructions to ensure complete and proper coverage. Pump pressure should be maintained to give an even fine spray and Finish as per the manufacturer's specification. Make: Fosroc Concure WB Sika Antisol EWP or equivalent in FOSROC/BASF. .
Making V groove of 10mm wide and 30mm deep or upto the extend of crack present at site over crack line using electricity operated angle grinder with diamond concrete saw blade and cleaning it by air blower. The groove shall be cut on the concrete surface along the crack over beam or column to be repaired, there after sealing of exposed ‘V’ grove with solvent –free, moisture tolerant, thixotropic, two part structural adhesive and epoxy repair mortar cum surface leveling mortar as per manufacturer's instructions and as directed by Engr-In-Charge. Make: Sika Sikagard 694 F(I)Fosroc Nito cote-VF or equivalent in BASF. .
PRESSURE GROUTING IN THE HONEY COMBED CONCRETE Providing and fixing grouting nozzles and injecting high strength epoxy resin injection through the nozzles under pressures using grout pump to fill all possible and gaps left within concrete mass, all per directions of Engineer-in-Charge, the process shall consist of;- 1. Drilling Hole : drilling holes in structural members at the intervals as per recommendation of engineer in charge. 2. Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. 3. Fixing of Nozzles : Insert 12 mm dia, 50-75 mm long injection packers in cleaned holes with structural grade epoxy adhesive. 4. Supply and apply a shrinkage free low viscous epoxy resin based injection grout. 5. Cutting of Packers/Nozzles : Cut the packers by out of wheel after completion of grouting without damaging structural elements. Make: Sika Sikadur 52/Fosroc CONBEXTRA-Ep 10 or equivalent in BASF. .
15-16mm thick granite (Zed Black), machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting to fix WHB of required size and grinding and polishing and providing nosing, rounding to edges of stone slabs one edge, complete all as specified and as directed. Note: Granite shall be provided in single piece. For payment purpuse no deduction for opening made for WHB shall be made. .
Taking down old unserviceable/deteriorated batten/PVC conduit point wiring aluminium/ copper from existing place i.e. light, fan, socket or power points complete with all unserviceable fittings such as switches, sockets,bell push , ceiling rose, pendants, Holders, etc, with and including sunken boxes, concealed/surface condit with all fittings such as bends jection, elbow etc for new provn and making good the disturbed surface in cement mortar 1:4, complete all as specified and directed.
Taking down old unserviceable ceiling fan regulator any type, complete all as specified and directed.
Taking down old unserviceable call bell any type, complete all as specified and directed.
Taking down old unserviceable submain wiring any size 4/6 Sq mm 02 run copper conductor single phase with earth wire including PVC conduit, complete all as specified and directed.
Taking down old unserviceable FTL /bulk head/security light etc light fitting any type and sketch fittings, complete all as specified and directed.
Taking down unserviceable MCB DB, SPN/TPN with MCBs of any make/capacity, complete all as specified and directed.
Point wiring with 1.5 Sqmm, multistrand, copper conductor cable, FRLS, PVC insulated and unsheathed, drawing in and including PVC conduit of appropriate size (wall thickness not less than 1.8mm thick) concealed in wall and surface on ceiling fixed with saddles (for fan Points only), terminated in sunken anodised pressed steel terminal boxes of not less than 1.6mm sheet thickness of appropriate size, covered with 3mm thick plastic laminated sheet top cover with brass screws for mounting switches, sockets, regulators etc. and continuous PVC insulated and unsheathed 1.5 Sqmm multistrand copper conductor cable FRLS, PVC insulated and unsheathed as earth wire, complete all as specified and making good to disturbed surface in cement mortar 1:3 for one light/fan/bell point controlled by one switch 5/6 Amp.
Point wiring with 1.5 Sqmm, multistrand, copper conductor cable, FRLS, PVC insulated and unsheathed, drawing in and including PVC conduit of appropriate size (wall thickness not less than 1.8mm thick) concealed in wall, terminated in sunken anodised pressed steel terminal boxes of not less than 1.6mm sheet thickness of appropriate size, covered with 3mm thick plastic laminated sheet top cover with brass screws for mounting switches, sockets, regulators etc. and continuous PVC insulated and unsheathed 1.5 Sqmm multistrand copper conductor cable FRLS, PVC insulated and unsheathed as earth wire, complete all as specified and making good to disturbed surface in cement mortar 1:3 for one socket outlet 5 Amp point controlled by one switch 5 Amp ON INDEPENDENT BOARD.
Point wiring with 2.5 Sqmm, multistrand, copper conductor cable, FRLS, PVC insulated and unsheathed, drawing in and including PVC conduit of appropriate size (wall thickness not less than 1.8mm thick) concealed in wall, terminated in sunken anodised pressed steel terminal boxes of not less than 1.6mm sheet thickness of appropriate size, covered with 3mm thick plastic laminated sheet top cover with brass screws for mounting switches, sockets, regulators etc. and continuous PVC insulated and unsheathed 2.5 Sqmm multistrand copper conductor cable FRLS, PVC insulated and unsheathed as earth wire, complete all as specified and making good to disturbed surface in cement mortar 1:3 for 15 Amp socket outlet independent.
Point wiring with 1.5 Sqmm, multistrand, copper conductor cable, FRLS, PVC insulated and unsheathed, drawing in and including PVC conduit of appropriate size (wall thickness not less than 1.8mm thick) concealed in wall and surface on ceiling fixed with saddles (for fan Points only), terminated in sunken anodised pressed steel terminal boxes of not less than 1.6mm sheet thickness of appropriate size, and continuous PVC insulated and unsheathed 1.5 Sqmm multistrand copper conductor cable FRLS, PVC insulated and unsheathed as earth wire, complete all as specified and making good to disturbed surface in cement mortar 1:3 for One light/fan/bell point controlled by one switch 5/6 Amp. Note:-For modular switch/sockets/bell push etc modular sheet metal enclosure and cover plate will be measured and paid for seperatly
Point wiring with 1.5 Sqmm, multistrand, copper conductor cable, FRLS, PVC insulated and unsheathed, drawing in and including PVC conduit of appropriate size (wall thickness not less than 1.8mm thick) concealed in wall, terminated in sunken anodised pressed steel terminal boxes of not less than 1.6mm sheet thickness of appropriate size, and continuous PVC insulated and unsheathed 1.5 Sqmm multistrand copper conductor cable FRLS, PVC insulated and unsheathed as earth wire, complete all as specified and making good to disturbed surface in cement mortar 1:3 for One socket outlet 5 Amp point controlled by one switch 5 Amp ON INDEPENDENT BOARD. Note:-For modular switch/sockets/bell push etc modular sheet metal enclosure and cover plate will be measured and paid for seperatly
Point wiring with 2.5 Sqmm, multistrand, copper conductor cable, FRLS, PVC insulated and unsheathed, drawing in and including PVC conduit of appropriate size (wall thickness not less than 1.8mm thick) concealed in wall, terminated in sunken anodised pressed steel terminal boxes of not less than 1.6mm sheet thickness of appropriate size, and continuous PVC insulated and unsheathed 2.5 Sqmm multistrand copper conductor cable FRLS, PVC insulated and unsheathed as earth wire, complete all as specified and making good to disturbed surface in cement mortar 1:3 for 15 Amp socket outlet independent. Note:-For modular switch/sockets/bell push etc modular sheet metal enclosure and cover plate will be measured and paid for seperatly Note for Srl item No 212 to 218:- The rates for point wiring includes for cutting chases in wall and making good the disturbed surface in cement mortar 1:6.
Modular switch single pole, one way, 6 Amps, 1 module, complete all as specified and as directed.
Modular switch single pole, one way, 16 Amps, 1 module, complete all as specified and as directed.
Modular socket, 6 Amps, 2/3 pin combined 2 module, complete all as specified and as directed.
Modular socket, 6/16 Amps, 2/3 pin combined 2 module, complete all as specified and as directed.
Modular Bell push 6 Amp, single pole, 1 module, complete all as specified and as directed.
Modular step type fan regulator, 120W , 2 module, complete all as specified.
Modular TV socket , 1 module, complete all as specified.
Modular Telephone jack with shutter, 1 module, complete all as specified.
Modular white cover plate with frame 1 module complete all as specified and as directed.
Modular white cover plate with frame 2 module complete all as specified and as directed.
Modular white cover plate with frame 3 module complete all as specified and as directed.
Modular white cover plate with frame 4 module complete all as specified and as directed.
Modular white cover plate with frame 6 module complete all as specified and as directed.
Modular white cover plate with frame 8 module complete all as specified and as directed.
Modular flush box 1/2 module fabricated out of MS sheet 1.6mm thick, complete all as specified and as directed.
Modular flush box 3 module fabricated out of MS sheet 1.6mm thick complete all as specified and as directed.
Modular flush box 4 module fabricated out of MS sheet 1.6mm thick complete all as specified and as directed.
Modular flush box 6 module fabricated out of MS sheet 1.6mm thick complete all as specified and as directed.
Modular flush box 8 module fabricated out of MS sheet 1.6mm thick complete all as specified and as directed.
Switch piano flush button 5 Amp single pole, one way, complete all as specified.
Switch piano flush button 15 Amp single pole, one way, complete all as specified.
Socket outlet 2 in 1, 3 pin, 5/6 Amp, flush type, complete all as specified.
Socket outlet combination, 2 in 1, 3 pin, 5 & 16 Amp, flush type universal, complete all as specified.
Bell push, flush type, 5/6 Amp, complete all as specified.
Ceiling rose surface type, bakelite 65mmx50mm, 3 terminals, complete all as specified..
Angular lamp holder PVC/polycarbonate type with back plate for batten fittings, complete all as specified.
Electric bell, Ding-Dong, 230 Volts, complete all as specified.
Stepped type electronic fan regulator, flush type, complete all as specified.
TV socket with shutter, flush type, with and including sunken box and hylam sheet cover of suitable size, complete all as specified.
Non Metallic Rigid PVC conduit, ISI Marked, conforming to IS 9537, medium grade of size 25 mm dia (wall thickness not less than 1.8mm) including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete including Cutting & Chasing required on brick wall not exceeding 10 CM girth for concealed conduit wiring and making good to disturbed surface with cement mortar 1:3 complete all as specified and directed.
Sub main wiring with four run of FRLS PVC insulated unsheathed flexible copper conductor (Multistranded), single core of size 16 Sqmm, 1100 Volts grade and two run of 16 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing incl PVC flexible conduit drawing in new/existing PVC rigid conduit, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing, complete in all respect all as specified and directed. Note :- Four run of single core cable with two run of continuous earth wire of copper conductor wire and shall be measured and paid as one unit length.
Sub main wiring with four run of FRLS PVC insulated unsheathed flexible copper conductor (Multistranded), single core of size 10 Sqmm, 1100 Volts grade and two run of 10 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing incl PVC flexible conduit drawing in new/existing PVC rigid conduit, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing, complete in all respect all as specified and directed. Note :- Four run of single core cable with two run of continuous earth wire of copper conductor wire shall be measured and paid as one unit length.
Sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistrands), single core of size 6 Sqmm, 1100 Volts grade and one run of 6 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing incl PVC flexible conduit drawing in new/existing PVC rigid conduit, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing, complete in all respect all as specified and directed. Note :- Two run of single core cable with one run of continuous earth wire of copper conductor wire shall be measured and paid as one unit length.
Sub main wiring with two run of FRLS PVC insulated unsheathed flexible copper conductor (Multistranded), single core of size 4 Sqmm, 1100 Volts grade and one run of 4 Sqmm FRLS PVC insulated unsheathed as earth (In Green Colour), flexible copper conductor (Multistrands) for continuous earthing incl PVC flexible conduit drawing in new/existing PVC rigid conduit, connecting incoming / outgoing electric connections by using required size copper lugs / thimbles and making good the disturbed surface to match with existing, complete in all respect all as specified and directed. Note :- Two run of single core cable with one run of continuous earth wire of copper conductor wire shall be measured and paid as one unit length.
SPN Distribution Box, double door of protection grade IP 43 in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 8 way, confirming to IS 13032 & 8623 complete all as specified and directed. Make- Legrand cat no 507611 or equivalent in Make as per Appx `E' to Particular specification. Note: MCB DB and MCBs shall be of same make.
MCB SPN, 40 to 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408618 to 408620 or equivalent in Make as per Appx `E' to Particular specification.
MCB SP, 6 to 32 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408587 to 408595 or equivalent in Make as per Appx `E' to Particular specification.
MCCB 4 pole , 125 Amps, 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand Model DPX3 160 cat no 420056 or equivalent in Make as per Appx `E' to Particular specification.
MCB TPN, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408683 or equivalent in Make as per Appx `E' to Particular specification.
MCB TP, 63 Amps 240 volts, AC , 10 KA breaking capacity 'C' Series,"ISI marked and conforming to IS 8828/IEC 60898-1 complete all as specified and directed. Make- Legrand cat no 408661 or equivalent in Make as per Appx `E' to Particular specification.
AC box by modular type enclosure with 4 module 25 Amps socket and 25 Amps plug single pole and neutral fitted with two pin and earth plug and socket complete with , 240 volt, 25 Amps ,power unit of suitable rating including taking down old AC box, complete all as specified and directed . Make- Crabtree Cat No ACAO252504 or equivalent in Make as per Appx `E' to Particular specification.
TPN Distribution Box double door of protection grade IP 43, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way,vertical incl provide the fixing arranegement of MCCB 4 pole 125 Amps as incomer confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make- Legrand cat no 507895 or equivalent in Make as per Appx `E' to Particular specification.
TPN Distribution Box double door of protection grade IP 43, in fine powder coated, matt finish with best CRCA sheet, fitted with shrouded neutral, insulated pin type copper bus bar, Din rail, earth bar of 4 way, confirming to IS 13032 & 8623 including chasing/cutting of wall and concealed and making good as existing surface complete all as specified and directed. Make- Legrand cat no 507780 or equivalent in Make as per Appx `E' to Particular specification.
Wall mounted LED batten 18/20 Watt with 01 No LED tube rod, extruded aluminium heat sink provided for efficient heat dissipation and integrated electronic driver complete all as specified and directed. Make- CG cat No LDL-20-CDL or equivalent in Make as per Appx `E' to Particular specification.
Taking down of LED tube light fitting with tube and store in safe custady carefully and refixing at same/other places of serviceable light any capacity any type incl proper connection with ceiling rose with new 3 core connecting copper conductor wire all as specified and directed
Wall mounted Mirror light LED fitting, 10 Watt, 2 Feet long incl integrated electronic driver including dismantling taking down unsv sketch fitting any type complete all as specified and directed. Make- Crompton Cat No LDL-10-CDL or equivalent in Make as per Appx `E' to Particular specification.
Decorative wall mounnted luminaire with & including 09 watt LED lamp complete as directed and specified Make- Havells cat No LHFOAJE1TN1I060 or equivalent in Make as per Appx `E' to Particular specification.
LED building security light 35 watt, 230V complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm three core copper flexible conductor cable, One GI medium grade suitable size dia bracket of total length 50 cm and fixed to wall with 2 Nos MS Clamp 32x6mm and fastener incl taking down unsv fitting any type, complete all as specified and directed. Make- Crompton Cat No LSTS-36-CDL-M or equivalent in Make as per Appx `E' to Particular specification.
LED lamp 12 watt, CDL, B-22 base, 230V, PF-0.95 (min) incl dismantling/taking out unsv CFL/LED Bulb.
Taking down existing ceiling fan and deposited in MES store for safe custudy all as directed
Taking down existing exhaust fan and deposited in MES store for safe custudy all as directed
Ceiling fan (white) complete 230 V,1200 mm sweep. BEE 5 star rated white colour including all fixing arrangement and connection with 3 core flexible copper cable all as specifed and directed . Make- Crompton model HS Plus equivalent in Make as per Appx `E' to Particular specification.
Exhaust fans (metal body) AC single phase 230/ 240 V of size 300 mm sweep 900 RPM with louver including cutting of hole of adequate size including making good existing surfaces with and including fixing with MS fasnut all as specified and directed Make- Havells model Turbo Force or equivalent in Make as per Appx `E' to Particular specification.
Refixing of existing serviceable ceiling fan any size from MES store yard along with new connection wire 3 core and new MS clamp properly all as directed
Refixing of existing serviceable exhaust fan any size from MES store yard along complete with and including fixing with fasnuts and provisioning of three core flexiable copper cord of size 23/0.0076 of required length from ceiling rose or connector to Exhaust fan for connection, complete all as specified & directed.
Wall mounted fan 230 volts single phase oscillating 400 mm sweep suitable for wall mounting incl connection and fixing arrangement all as specified and directed. Make- Crompton/Bajaj/Havells
Taking down Old unserviceable rusted earthing plates, complete all as directed.
Taking down old unserviceable / defective energy meter any type any capacity and deposited to MES E/M store all as specified and directed
Taking down old serviceable energy meter any type any capacity and deposited to MES E/M store and refixing after complete repairs of the block and making connection, complete all as specified and directed
AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlite LCD display of rating 5 - 30 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power alongwith transparent hinge type PVC meter box including connection with thimble , PVC flexible pipe and proper sealing all as specified and directed.
AC Three phase static energy meter of accuracy class 1.0, 3 X 240 V, 50 Hz with Backlite LCD display of rating 10 - 60 A (suitable for measurement of KWH only) with special features like TOD, temper logging, optical communication port display in absence of power alongwith transparent hinge type PVC meter box including connection with thimble , PVC flexible pipe and proper sealing all as specified and directed .
Earthing as per IS:3043 with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funnel and making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonry including excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire with Gi protection pipe upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately).
Taking down old unserviceable LT cable/service connection 1100 volts 16sqmm 2 core/4core, complete all as specified & directed.
Taking down old unserviceable LT cable/service connection 1100 volts 35sqmm to 50 sqmm 3.5 core, complete all as specified & directed.
Sand cushioning to underground cables complete all as specified in clause 19.75 of SSR Part-I laid before and after laying of cable, complete all as specified. Note: For measurement pupose punned depth shall be measured.
Sub class ‘B brick, old size, brick covering laid dry, flat, transversally along the length of cable on sand cushioning, with width equal to the length of the brick, complete all as specified and directed.
GI tubing (light grade) with all fittings, laid in trenches or under road crossing as protection pipe, or fixed alongwith walls/poles with and including clamps, bore of pipe 40mm including taking down existing pipe, complete all as specified.
GI tubing (light grade) with all fittings, laid in trenches or under road crossing as protection pipe, or fixed alongwith walls/poles with and including clamps, bore of pipe 50mm including taking down existing pipe, complete all as specified.
Cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 30 cm in depth for passing of UG cable/pipe lines and making good of disturbed surface to match with the existing surfaces by using new material i.e bitumen, aggregate complete incl compaction of cutting portion and making good all as specified and directed .
1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 16 Sqmm 2 core with required aluminium cable lugs, fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board all as specified and directed. Note:- Earth work, brick protection and sand cushioning shall be measured and paid for separately.
1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 16 Sqmm 4 core with required aluminium cable lugs, fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board all as specified and directed. Note:- Earth work, brick protection and sand cushioning shall be measured and paid for separately.
1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 35 Sqmm 3.5 core with required aluminium cable lugs, fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board all as specified and directed. Note:- Earth work, brick protection and sand cushioning shall be measured and paid for separately.
1100 volts grade heavy duty cable with PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape, armoured with galvanised steel wire or tape and overall PVC sheathed 50 Sqmm 3.5 core with required aluminium cable lugs, fixing or passing through pipe, laid in trenches or fixed to pole/wall or fixed to LT panel board all as specified and directed. Note:- Earth work, brick protection and sand cushioning shall be measured and paid for separately.
Post top lantern light fitting 40 watt LED decorative indirect light with IP 65 protection complete with all accessories including taking down old, complete all as specified and as directed. Make:- Crompton cat part no LPTO-40-CDL or equivalent in Make as per Appx `E' to Particular specification.
Taking out old unserviciable 40/50mm bore GI water tubing lines and connected unserviceable pipe and fitting including segregation of serviceable pipe and fittings and keep in safe custody for reuse serviceable pipe line and fitting from trench/ in ground/under road /under PCC path etc at the site of work complete all as specified and as directed.
Taking out old unserviciable 25/20mm bore GI water tubing lines and connected unserviceable pipe and fitting including segregation of serviceable pipe and fittings and keep in safe custody for reuse serviceable pipe line and fitting from trench/ in ground/under road /under PCC path etc at the site of work complete all as specified and as directed.
Taking out old unserviciable old unserviceable gate valve 20mm/25mm dia, complete all as specified and as directed.
Taking out old unserviciable old unserviceable gate valve 40mm/50mm dia, complete all as specified and as directed.
GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., in old existing or new routes, laid in trenches or under roads, bore of pipe 50mm, complete all as specified & directed.
GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., in old existing or new routes, laid in trenches or under roads, bore of pipe 40mm, complete all as specified & directed.
GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., in old existing or new routes, laid in trenches or under roads, bore of pipe 25mm, complete all as specified & directed.
GI water tubing, medium grade, with all fittings such as sockets, bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs and unions etc., in old existing or new routes, laid in trenches or under roads, bore of pipe 20mm, complete all as specified & directed.
Refixing/laying old GI water tubing, any grade, with all fittings such as socket, bends, elbows, tee, union etc., laid in trenches or under roads or above G.L in new or old position, bore of pipe 50mm. Note: Pipe retrieved from taking down shall be reused. Cost of new fittings, if required, including cutting, threading, as required as per site requirement, shall be deemed to be included in the rate quoted.
Refixing/laying old GI water tubing, any grade, with all fittings such as socket, bends, elbows, tee, union etc., laid in trenches or under roads or above G.L in new or old position, bore of pipe 40mm. Note: Pipe retrieved from taking down shall be reused. Cost of new fittings, if required, including cutting, threading, as required as per site requirement, shall be deemed to be included in the rate quoted.
Refixing/laying old GI water tubing, any grade, with all fittings such as socket, bends, elbows, tee, union etc., laid in trenches or under roads or above G.L in new or old position, bore of pipe 25mm. Note: Pipe retrieved from taking down shall be reused. Cost of new fittings, if required, including cutting, threading, as required as per site requirement, shall be deemed to be included in the rate quoted.
Refixing/laying old GI water tubing, any grade, with all fittings such as socket, bends, elbows, tee, union etc., laid in trenches or under roads or above G.L in new or old position, bore of pipe 20mm. Note: Pipe retrieved from taking down shall be reused. Cost of new fittings, if required, including cutting, threading, as required as per site requirement, shall be deemed to be included in the rate quoted.
Gun-metal, globe or gate valves of 20mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified.
Gun-metal, globe or gate valves of 40mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified.
Gun-metal, globe or gate valves of 50mm dia, with iron wheel head, screwed both ends for iron pipe, complete all as specified.
Construction of brick masonary valve pit of size 600mmx600mmx600mm (Internal dimension) with follwing specifications :- Pit shall be underground with foundation in PCC (1:3:6) type-C2 brick work in CM (1:6), internally finished with 15mm thick cement plaster in CM 1:4 and externally flushed pointed as work proceeds. Flooring shall be 40mm thick PCC (1:2:4) type B-1 laid over 75mm thick hardcore. Cover shall be of 6mm thick MS black sheet fixed to angle iron frame made out of 25x25x6mm by friction hinges welded to frame and sheet. Angle iron frame will be grouted on masonry chamber with MS hold fasts. Locking device will be provided to lock MS sheet cover to angle iron frame. One handle made out of MS round bar 12mm dia D type 15cm long shall also be welded on MS sheet cover. The steel surfaces exposed to view shall be painted with two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, complete all as specified and as shown in drawing No. CEUZ/TD/1500/15 sheet 1/1 dt 12.01.2015
CREDIT SCHEDULE: Deduct credit schedule Part-II Rs 23,11,447.00 (Minus) as listed in Schedule. Note: Tenderers will not quote against this item being a firm amount. Contract Sum will be worked out after deducting the credit schedule amount during acceptance of tender.
Gupta Construction Company
M/s Khajuria Construction Co.
SHIV CHARAN GUPTA AND SONS
DES RAJ NAGPAL CONTRACTORS PVT.LTD
vijay builders
MOOL RAJ SHARMA
M/s Ravinder Kapoor Engineers and Builders
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid