Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance G 1 1154A MANSAROVER PARK SHAHDARA DELHI DELHI 110032 | SHAHDARA | DELHI | 110032 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹19.6 L
EMD Value
₹39,217
Closing Date
1 Sept 2020, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer Elect
O/o EE (E), PWD NES/ M-251, LM Bund Road, Ramesh Park, Delhi-92
RMO E and M Services at Sanskar Ashram Dilshad Garden Delhi. 2 At VREC Rohtas nagar and Gokalpuri. 3). At Anand gram, Kasturba gram, Gandhi gram, Leprosy Complex and HLTB/HLAB Jail block, Tahirpur Delhi. (SH- Improvement E.I and Fans)
2020_PWD_193807_1
21/EE (E)/ PWD NE and Shah. Elect. Divn/20-21
Open Tender
Electrical Works
Item Rate
60 days
Vrs Sites under SD-2
Please refer Tender documents.
10 documents required · 10 mandatory
₹0
₹39,217
5 Sept 2020
24 Aug 2020
1 Sept 2020
24 Aug 2020
1 Sept 2020
24 Aug 2020
30 days
Amount
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. "Group C"
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Double pole
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6 way, Double door
12 way, Double door
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 kA,TPMCCB
250 A, 25 kA,TPMCCB
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connection but excluding modular plate etc as reqd.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 8 way (4 + 24), Double door
12 way (4 + 36), Double door
S.I.T.C of 18 to 20 watt 1200 mm long high efficiency LED linear batten Luminaries having aluminium extruded housing and polycarbonate diffuser within built APFC driver having efficiency of driver 85% power factor > 0.90, THD <20% with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency 100 luman per watt. and colour temperature of 6000 K, CRI >80 including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable i/c dismantling of existing old fitting if any etc. Complete as required.
Supplying and Fixing 380 mm dia 900 RPM exhaust fan heavy duty PVC type suitable for operation on 230 volt, ±10%, 50 Hz supply to fixed on wall i/c connection with 1.5 Sq.mm PVC insulated PCV sheathed copper conductor single core cable i/c testing etc as reqd.
Supplying Installation, testing & commissioning of wall fan 400 mm sweep in the existing surface and making good the damage, making connections, interconnections, earthing etc, as required.
S.I.T.C of 36 to 40 watt recessed mounted LED Luminaries of size 600 mm (Length) x 600 mm (Width) housing made with white powder coated CRCA sheet metal and polycarbonate diffuser suitable for operation on 150 to 265V single phase A.C. supply, having system efficiency not less than 100 luman per watt. and colour temperature of 6000-6500 K, CRI >80 with driver having power factor > 0.90, THD < 20% and efficiency > 85% driver should be IC Complete, with minimum 2.5 KV surge protection, LED life with L-70 criteria shall be not less than 50000 burning hours etc. including connection with 1.5 sq. mm. PVC insulated copper conductor FRLS cable with the help of 4 nos. fastener Hook, Clutch wire and sleeve etc. i/c making connections, testing, commissioning etc. complete as required.
Supplying and Fixing of 70-80 watt LED Flood Light fitting aluminium die cast housing ,IP 65 with high power LED as light source, system lumen efficiency of ≥ 120 lm/W, min lumen output 8000 lumens colour rendering (CRI) ≥ 70, and correlated colour temperature (CCT) of 5500 - 6500 (±300K). The luminaries should have 10KV surge protection, PF≥0.95, the total harmonic distortion≤ 10% operatable in voltage range of 220-270 V, total burning hours 50000 with LM 70/79/80 Certificates The driver used must be a constant current driver with efficiency of ≥ 85% and driving current ≤ 725mA complete r on surface with suitable fasteners as required and as per direction of Engineer-In charge. i/c dismantling of existing fittings.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
6 x 1.5 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Replacement of old defective boxes by Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches etc. as required. 3 Module (100 mmX75 mm)
6 Module (200 mmX75 mm)
8 Module (125 mmX125 mm)
12 Module (200 mmX150 mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 amp socket outlet
S & fixing 3 x 10 sqmm. P.V.C insulated XLPE Al. conductor armoured cable on surface of wall i/c connection testing etc. as required.
S & fixing 3.5 X120 sqmm. P.V.C insulated XLPE Al. conductor armoured cable on surface of wall i/c connection testing etc. as required.
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
S.I.T.C of 5 KVA single capacity double step automatic voltage stabilizer with working range 170-270 volt including suitable connection etc. complete as required.
Supplying & Replacement of existing of old worn out of stainless steel storage type water cooler 150/150 Ltr. capacity, fully stainless steel suitable for operation on 230 V+10% 50 Hz single phase AC supply i/c making water line and electrical connection etc as required.
SITC Reverse osmosis system with U.V technology in completely concealed unit designed to deliver up to 150 liters per hour of purified water through a 6 stage purification process. Its membrane have a pore size which prevents the passage of micro organisms and total dissolved salts making the water lighter, taste natural and safe to drink. Technical Specification (i) Production Capacity 150 LPH (ii) RO Membrane (Thin Film Composite) 300 GPD x 3 Nos. (iii) Input Power Rating 230 V AC,50 Hz (iv) Operating Temperature 5 Degree C TO 45 (v) % of Recovery of Purifier Water 70% (vi) % of Rejection in TDS 95 % Approx. (vii) Maximum Inlet (TDS) water:- 1500 PPM (viii) Stages of Filtration Particulate Filter-Membrane Life Enhancer Filter-Sediment Filter-Pre-carbon Filter-R.O. Membrane Filter-Post Carbon Filter (ix) suitable size pump
S/F of 3 Core 1.5 sq.mm PVC insulated Copper Wire as main lead of Desert/Room coolers i/c commissioning etc. as required.
Less on account of buy back of following dismantled material received from this site.
Box type fittings/Mirror optic
MCB/MCCB
TPMCCB
Water Cooler
XLPE cable
M/s JAI SHREE BALAJI ELECTRICAL
Uday Raj Pandey
Krishna Electreical Works
M/s Rahul Associates
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .