Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.7 L
Closing Date
3 Aug 2026, 3:30 pm
Signalling work in connection with "Construction of ROB in lieu of LC-40 and LC-42 in Solapur-Kurduwadi section of Solapur Division".
SUR-N-T-2026-27-21
SUR-N-T-2026-27-21
Open
12 Months
Solapur, Maharashtra
₹0
₹2.7 L
3 Jul 2026
3 Jul 2026
20 Jul 2026
02-SOR EXECUTION
03-NS SUPPLY AND EXECUTION
Item Breakup - 01-SOR SUPPLY
Modification in existing EI system as per latest Per TAN, it includes :- Design and modification in Alteration existing interface and interlocking circuit of EI system, including modification in VDU, CCIP, MT, Data logger, EI, Relay rack complete wiring conforming to RDSO specification, as per technical requirement & tentative approved signalling plan/diagrams. Required hardware will be provided by railways except the wiring, material (i.e. connectors, interconnecting cable/wires, fuses etc.). The work includes supply of modified ST/LT, interface and logic circuit, CCIP/VDU diagram etc. to suit the approved interlocking plan. It also includes modification in data logger/MT, carrying out FAT, SAT jointly with railways and satisfactory commissioning of the modified EI with full complements as per approved IP and central railway practices. All Plans and wiring diagrams shall be prepared on AUTOCAD and supplied in both soft copy and hard copies(6 sets). Alteration involving modification in upto 10 routes. (Inspection by Consignee).
Supply of Program switches with acrylic cover, Numbers snap action, base mounting type along with cover and mounting bracket 25A-7 pole 3 position Siemens type (3 LAO-25/7Y) / L&T/HAVELLS type. Drg. No. RST.C.106. (Inspection by Consignee).
Supply of Program switches, snap action, base Numbers mounting type along with cover and mounting bracket 63A-7 pole 3 position Siemens type (3 LAO-63/7Y) / L&T/HAVELLS type. Drg. No. RST.C.106 .(Inspection by Consignee)
Supply of Transformer 230V/110V-130V Single Numbers Phase 1 KVA as per RDSO/SPN/165/2023 version 4.0 Amendment 1.0 (Or latest) . (Inspection by RDSO)
Supply of Battery Charger self regulating floor Numbers mounting type with 230 V AC single phase input and output 110 V DC, 40A as per spec.IRS:S-86/2000 (Amd. 4) (Or latest) . (Inspection by RDSO)
Supply of Battery Charger self regulating floor Numbers mounting type with 230 V AC single phase input and output 24 V DC, 20A as per spec. IRS:S-86/2000 (Amd. 4) (Or latest) (Inspection by RDSO)
Supply of Battery Charger self regulating floor Numbers mounting type with 230 V AC single phase input and output 24V DC, 20A as per spec.IRS:S-86/2000 (Amd. 4) (Or latest) . for Axle counter applications (Amd.4) (Inspection by RDSO)
Supply of Battery Charger self regulating floor Numbers mounting type with 230 V AC single phase input and output 24V DC, 30A as per spec.IRS:S-86/2000 (Amd. 4) (Or latest) for Axle counter applications (Amd.4).(Inspection by RDSO)
Supply of 63 A rating, 4 pole changeover Numbers switch disconnector with dual shaft position & staggered terminals with sheet steel enclosure and extended handle of Siemens/ L&T/ HAVELLS/ LEGRAND make.(Inspection by Consignee). SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of QNA1 AC immunised relay, 8F-8B, Numbers 24 VDC along with plug board, retaining clip and connectors confirming to BRS:930: IRS S 34: IRS S 23 (Or latest) (Inspection by RDSO).
Supply of QTA2 AC immunised track relay, 9 Numbers Ohm, 2F.1B, along with plug board, retaining clip and connectors conforming to BRS: 939A & 966 (App F2) & IRS:S - 23, S34 & 60 (Or latest) (Inspection by RDSO).
Supply of QBCA1 AC immunised relay, 2FHD - Numbers 4B,24VDC along with plug board, retaining clip and connectors conforming to BRS:943; IRS S 34: IRS S 23 IRS S 60-78 (Or latest). (Inspection by RDSO).
Supply of QL1 LATCH relay, 11F-4B or 8F-6B Numbers along with plug board, retaining clip and connectors conforming to BRS:935A; IRS S 34:IRS S 23 (Or latest) (Inspection by RDSO).
Supply of Universal LED Lamp proving relay Numbers QECX61 relay, 4F-4B,AC conforming to BRS:941A, STS/E/RELAYS/AC LIT LED SIGNAL/09-2002 Amdt1, IRS S-23 & 34 (Or latest)(Inspection by RDSO).
Supply of Apparatus Case with godown locks Numbers with detachable handle on both the doors. Single Case as per Drg. No.SK 783-1 & 2 with latest alteration. (Inspection by RITES)
Supply of Apparatus Case with godown locks Numbers with detachable handle on both the doors. Half Case as per Drg. No.SK 783-1 & 2 with latest alteration.(Inspection by RITES)
Supply of Hand Cuff Locks/ Godrej Navtal lock Numbers with Three common keys.(Inspection by Consignee).
Supply of Phenolic 10mm thick sheet, grade Numbers P3 in standard size of 1.22X1.22 Mtr as per spec. No IS 2036 of 1995. (Inspection by Consignee).
Supply of ARA Terminal blocks with links made Numbers 1900.00 of PBT Specn IRS: S-75/2006 (Rev.2) (Or latest) and RDSO Drg.No.SA-23741A Alt.4, SA- 23745 Alt.5, SA-23746, SA-23748 Alt.4 & SA- 23756A Alt.3. (Inspection by RDSO).
Supply of cartridge fuse block made of PBT as Numbers per RDSO Drg No SA-23748 Alt 4, SA-23749 & Spec No IRS: S-75/2006 (Rev.2) (Or latest). Fuse block shall be suitable for round head type voltage fuses. (Inspection by RDSO).
Supply of round head type non detoriating Numbers type low voltage cartridge fuse as per Specn No IRS/S/78/92 (Or latest) 2A/4A/6A capacity (Inspection by RDSO).
Supply of Tik-tak, piano type switches,5 A (as Numbers per IS Specification). (Inspection by Consignee)
Supply of three pole plug and socket 5 Amp Numbers (as per IS Specification). (Inspection by Consignee).
Supply of Lamp 110V/24W, 2 Pin for Loc. Numbers (Inspection by Consignee).
Supply of earth electrode assembly as per Numbers Drg.No. CR/S&T/SK-815 (Inspection by Consignee). SOLAPUR DIVISION-S AND T/CENTRAL RLY
Maintenance Free Earth as per RDSO/SPN/197, Set Ver.1.0 (Or latest) consisting of :1) Copper bond steel electrode 3 Mtr long 17mm dia with copper bonding thickness of min. 250 micron & UL listed & marked-01 No. 2) Earth enhancement compound RDSO Approved in sealed bag of 10 Kgs - 03 No. 3) Copper strip 150 x 25 x 6mm - 02 No. 4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection by RDSO)4) Copper strip 300 x 25 x 6mm - 01 No. 5) 35 Sqmm Copper Cable to connect earth electrode to MEEB - 15 Mtr Approx. (Inspection by RDSO).
Supply of Electronic Timers for DAC reset Numbers arrangement 3 sec to 30 sec with 2NO/2NC contact working voltage 24V/60V DC. Siemens/ABB/L&T or SELEC (642XA programmable electronic timer switch) make (Inspection by Consignee).
Supply of GI pipe, inner dia. 100mm dia. B- Metre class as per spec. No.IS 1239 PT. 1/2004 or l a t e s t with sockets and fittings. TATA/JINDAL/ZENITH BIRLA make. (Inspection by Consignee).
Supply of DWC HDPE pipe with one snap fit Metre coupler and 'O' ring fire resistant, anti rodent, in 6 meter length of size 120 mm outer dia as per RDSO/SPN/204/2011 Ver. 1.1 with Amd.1 or latest. (Inspection by Consignee).
Supply of Paints as per relevant IS Kg specification preferably Asian/ Apcolite/Dulux m a k e in different colours in one kg pack (Inspection by Consignee).
Supply of RCC pipes half round of size 150mm Numbers dia outer and 100 mm dia internal 1 mtr long matching to IS No. 458/2003 amendment-1 with Rev.4. DRG. DRM (S&T) SUR/ 06/2023/A. (Inspection by RITES).
Design, fabrication and supply of Fuse Alarm Numbers System for monitoring Location fuses [HRC type] of various types with automatic changeover facility along with Audio & Visual indications. (Inspection by Consignee).(UNIT- NUMBER=PER FUSE) SOLAPUR DIVISION-S AND T/CENTRAL RLY
Supply of as made documents (Manuals for Lot installation, testing and maintenance of the system) (One set consists s i x (06) sets of following documents per station). (i) Manual for installation, testing, commissioning and maintenance of the system for Technicians/Jr. Engineers (Installation and maintenanace level). (ii) Functioning and system overview (Higher Management Level)(iii) Completion document as per special conditions of contract. (iv)Design & Supply of circuits and plans to suit layout given in the signaling plan f o r Hot Standby Architechture Electronic Interlocking (EI) system. All plans and wiring diagram shall be prepared on Autocad Drawing and supplied with CD. This will include supply of Control-cum-Indication Panel/VDU diagram, Square Sheet, Wiring Diagrams (Application Logic and Interface Circuit), Fuse Analysis, Contact Analysis, Tag Block Analysis, Power Supply Distribution / Power Equipment arrangement (with program switch) Diagram, Auto Change over diagram (if supplied by the contractor) and all other relevant drawings. NOTE : The contractor shall initially supply 1 set of documents (Paper Prints) for approval of Railways. He shall ensure that each sheet has a block for signature of Railway Official as well as a block for signature of firm, duly signed by the authorised signatory of the firm. The name of the work as given by Railways shall be written on every sheet under the work column.( Inspection by Consignee).
Supply of GI bend pipe, 'B' class, 50mm dia Numbers for cable entry in point machines, along with required fixing arrangements as per standard practice on Central Railway. As per Drg.No DRM(S&T). (Inspection by Consignee).
Supply of Signal No.plates. as per Drg No RST- Numbers 11393 / SK-842 (Inspection by Consignee). Total 6480477.55
Item Breakup - 02-SOR EXECUTION
Installation distribution panel/Auto Changeover Panel, power supply equipments such as Rectifiers Transformers, Battery chargers etc., mounting of Program switches on bakelite sheet of size 300 mm x 300 mm x 8 mm fitted to MS angle (size 25mm x 25mm x 5mm) brackets, wiring as per requirements. Necessary wires to be supplied by Rlys, lugs & glands to be supplied by Contractor.
Erection of CLS Post with Surface base and Numbers signal unit on top or on OFF set Bracket, fixing of front and back staging, ladder and guards, signal name plates/boards if any with contractors own brackets and fixing materials. This also includes erection of auxiliary signals like calling on, shunt signal if any. The work shall be done as per instructions of Rly engineer at site.
Termination of tail cable on Main signal units Numbers and wiring with contractor own material, fixing of lenses etc. The work shall be done as per instruction of Rly engineer at site. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Fabrication laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site.Single Case.
Fabrication laminated/Fibre glass sheet in location box by providing all fixtures as per Railway Drawing including fixing of PVC coated/with PVC pipe covered string rods at the back side for cable support with contractor's own materials. The work shall be done as per drg and arrangement similar to SK 783-1&2. with latest alterations & as per instructions of Rly engineer at site.Half Case.
Fixing of ARA Terminals and fuse blocks on Numbers 1990.00 phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts.This includes provision of two additional holes on the board on either side for cable conductor entry.
Termination terminal/fuse blocks in the apparatus Cases/ Conductor cable termination rack.This includes all associated works of pulling out the cable from underground. The work shall be done as per location plans and instructions of Rly engineer at site.
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Single Case as per Drg No . SK-803.
Excavation and Casting of Apparatus Case Numbers foundation with contractors Anchor bolts, cement, ballast and other materials. The required scaffolding Ferma etc for Casting of foundation will have to be brought by the contractor at his own cost. Half Case as per Drg No . SK-804.
Erection of Apparatus Cases. This includes Numbers filling of location foundations with river bed sand and plastering on top of the sand. Single Case.
Erection of Apparatus Cases. This includes Numbers filling of location foundations with river bed sand and plastering on top of the sand. Half Case.
Installation of Eqpt. (Relays, resistance, Numbers chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. Single Case.
Installation of Eqpt. (Relays, resistance, Numbers chargers batteries etc.as applicable) & wiring of the same in apparatus Cases as per location diagrams & circuit diagrams, as per Instruction of site incharge and practice. Half Case. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Installation RDSO/SPN/197/Ver.I or latest, to construct earthing of </= 1 ohm consisting of a. digging the earth to required depth,insertion of electrode, filling of earth enhancing compound & construction of chamber, measurement of earth value and all other work of earthing as per code of practice. All the consumables for mounting the copper tape inside the relay room, Exothermic weld materials and tools & fixtures for the welding Copper tapes and electrodes shall be arranged by the contractor.
Excavation of cable trench as per cable route cum plan,1.0 mt. deep and 300mm wide along side the track in normal soil/strata, conforming to distances as per cable route plan and refilling after cable laying. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks, clearing of route, bushes etc. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Excavation of cable trench as per cable route cum plan,1 mt. deep and 300mm wide along side the track in hard soil, conforming to distances as per cable route plan and refilling. This work includes covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by stones/bricks, clearing of route, bushes etc. The work shall be done as per the extant practice on Central Railway and instructions of Railway Engineer at site. In case depth of trench is not achievable due to site conditions proportionate payment will be made.
Cutting of all types of Roads/ platforms cum preparatory to trenching and excavation to depth of 300mmx300mm wide approx. and refilling after laying of RCC/GI /DWC pipe & to restore them to original condition. The work shall be done as per extant practice on C.Rly & instructions of Rly engineer at site.
Fixing of GI pipes for crossing the culverts, Metre bridges etc. and concreting of ends with brick masonry at both ends as per the instruction of Rly engineer at site.
Digging of trench 1.0 M deep from rail cum flange/road level (for LC) and 0.3Mtrs. to 0.6 Mtrs wide and back filling after placing of DWC/RCC/GI pipe.(Placing of DWC/RCC/GI pipe coverd separately. The ballast disturbed be screened and dressed as required by Engineer-in-charge or his representatives and road tarred immediately. Drg. No. SK 806.
Laying of DWC/RCC pipes along with collars in Metre trenches at places of track and road crossings, platform cuttings etc.
Wherever depth of 0.5M cable trench is not cum feasible, cable shall be protected as under:- Preparation of cement mixture 1:3:6 with contractor's own materials and spreading cement concrete mixture layer of 100 mm thick over the already laid cables in the excavated trench. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Horizontal boring of cable duct of minimum Metre 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for track crossing with minimum depth reckoned from the bottom of the rail/road crossing with minimum depth reckoned from ground level. The work shall be done as per extant practice & instructions of site Engineer. Prepration of site for Horizondal boring shall be carried out in presence of Railway Representative. HDPE will be supplied by Railways. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable.
Releasing Equipments,relays and relay racks, CT racks, Batteries, Block Instts., Ground frame/s, Location Boxes, TLJBs, Signal Posts, Signal Units, Equipment inside the location boxes, Lifting Barrier , rodding runs,etc as applicable including the breaking of foundation etc. as per the instructions of Rly Engineer at site & their transportation to nominated depot.
Painting of two coats of synthetic enamel Numbers paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.Apparatus Case Full Size."
Painting of two coats of synthetic enamel Numbers paint over one coat of primer on the following after scraping & cleaning surface wherever necessary with contractor' own supply of paints.Wherever required contractor shall apply coating of epoxy paint also as per instructions of site-in-charge.Epoxy paint will be supplied by Railways. NOTE:- The paint and primer should be from M/s Asian paints Co. Ltd.,. The paints will be primer (IS 5660 of 1970) the Aluminium synthetic black enamel (IS 2932 of 1974) brilliant white and yellow Painting two coats of enamel paint over one coat of primer.Apparatus case Half Size.
Lettering / Numbering Termination particulars, Numbers equipments names etc., legibly and neatly inside location boxes. Full Case.
Lettering / Numbering Termination particulars, Numbers equipments names etc., legibly and neatly inside location boxes. Half Case. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Horizontal boring of cable duct of minimum Metre 2.0 Mtr. depth alongwith laying of 120mm HDPE pipe for other locations with minimum depth reckoned from the ground level. The work shall be done as per extant practice & instructions of site Engineer. Preparation of site for Horizondal boring shall be carried out in presence of Railway Representative.HDPE will be supplied by Railway. Note:- Contractor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. BORING upto the length of 150 mtrs. Preparation of site for Horizontal boring shall be carried out in presence of Railway Representative.
Laying of signalling/Power/Telecom cable of Kilometre various cores/sizes in trenches.
Installation of earth electrode assenbly as per Numbers Drg.No.RE/S&T/SIG/Tender/SK726/85 including earth wire connected through GI wire 8 SWG supported on M.S. flat of size 6mm x 40 mm to earth electrode as per drg. No. CR/S&T/SK- 815 for sigg. Equipment such as lever frames, apparatus case, signals, relay racks,block insruments, and etc. as per RE manual. The earth value should be less than 10 Ohms including the lead wire. The value should be measured in presence of Rly. supervisor. It should be documented and painted on earth enclosure made of concrete.( only earth electrode will be supplied by Railway). All other material required for provision of earthing will be brought by the contractor.
Preparation of cable route plan, cable coreage Lot plan, location particulars, Cable termination rack particulars, cable meggering report, earth resistance particulars, Traction bonding diagram, 1/2 wire count sheet and any other drawing in Autocad in A3/A4 size.The contractor shall initially supply 3 sets of circuits complete for approval of Railways. Railways will return one set to the contractor duly approved with alterations/corrections if any. The contractor shall incorporate Railways alterations/corrections in the tracings without any deviation and submit all tracings complete in all respects to the Railways . This includes submission of final cable route plan as per laid cable duly measured at every 30m clearly indicating distance of laid cable from fixed point of reference & indicating all track crossings and tail cables. This also include designing of cable coreage plan based upon I.P in consultation with engineer-in-charge. For small/medium yards (<= 100 routes). Total 1896580.50
Item Breakup - 03-NS SUPPLY AND EXECUTION
Industrial PC (MOXA, ARS, MEDHA) (Inspection Numbers by RDSO).
MASTER RING MODEM (Inspection by RDSO).
SLAVE RING MODEM (Inspection by RDSO).
IOCOM CPU Card (Inspection by RDSO). SOLAPUR DIVISION-S AND T/CENTRAL RLY
Vital interlocking computer card (Inspection by Numbers RDSO).
VDU 1/2 changover Consignee).
WFM Relay Driver card (Inspection by RDSO).
CIU voltage and health (Inspection by RDSO).
Supply and installation of concrete (RCC) Numbers route indicators at intervals of 50 meters as per technical specification. They should be standard RCC with letters on one side "CR" and the other side "S&T Cables" as per drawing SK 12/10 of RVNL SC. In case of Telecom quad cable joint locations it shall be painted with RED colour.( Inspection by Consignee).
Supply of Concrete Earth Pit with cover. Numbers (Inspection by Consignee).
HDPE Pipe 110 mm Diameter,PE63, Class PN6, Metre with confirming to IS4984 with ISI marked (or) Latest.( Inspection by Consignee).
Supply, commissioning of Bumpless Power Supply Autochangeover device complete along with accessories using Contractor's own wiring & fixing material as per following configuration - (i) Power Supply - AC/DC. (ii) Voltage 24V to 150V. (iii) Current Up to - 45Amp. Note: The work shall be done as per instructions of Railway's Engineer in-charge. (Inspection by Consignee).
Supply, Commissioning with OEM certification of Modular power supply arrangement for VDU (42""-85"") and embedded PC with input and output redundancy arrangement and hot pluggable modules having voltage & load current digital display on each module. Each set consisting of :- 1.Isolated inverters (master/slave with auto changeover)-2 Nos. input 110V DC, output 110VAC, 500VA (as per RDSO TAN No- STS/E/TAN/3012 Version 3.0 Dated-03.11.2022) 2. Isolated DC-DC converters-02 Nos. connected in parallel with built in O-ring diode, active current sharing as RDSO/SPN/165/2023 version 4.0 or latest (input:110VDC,output:24VDC/10A) 3.Input (redundancy)O-ring diode module with two input sources and one output supply along with potential free contacts, alarm and acknowledgment switch. 4. 3U stainless steel rack with back panel, mother board and front panel power connectors, power cord for VDU panel. Make-Gallant or similar. Specification details attached.(Inspection by Consignee).
Execution of S & T work related to engineering Job /Signalling block of CTR/TTR/TSR or others, in one block, five unskilled manpower have to be provided during block for S&T connection removing & refixing as per Railway site engineer instruction.
Providing Road breaker/Concrete Breaker with Hour compressor and jack hammer for railway work such as cutting and dismantling of road concrete/ Bricks pucca structure (RCC/Steel section) including contractor's fuel, driver and all other charges completed as directed by Engg in charge. SOLAPUR DIVISION-S AND T/CENTRAL RLY
Casting of cement concrete to protect S&T cum equipments and laid cables above pipes, signal store etc by concrete mixture of cement , sand, stone in the ratio of 1:2:4 using 25 mm graded stone aggregate as per instruction of site in charge of railways. Concrete is to be casted with the help of suitable size of shuttering from as per site requirement. concrete is to be cured for sufficient time as per standard practice of railways.
Metravi Digital AC/DC Leakage Low Current Numbers Clamp Meter 23 mm Yellow & Black, 4672 or similar ( Inspection by Consignee) Total 4966266.22
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Instructions_To_Tenderer_LC_40_0_LC_42_Re.pdf