Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹7.6 LAccepted-AOC | 1st | Accepted-AOC The lowest bidder M/s Kailash Chand Babulal has been accepted pl. | |
| 2 | 2nd₹8.0 L+₹14,240 (1.82%)Rejected-Finance FLAT NO 201 LAXMI PARK NIWAS BT KAWADE ROAD GHORPADI PUNE 411036 | PUNE | MAHARASHTRA | 411036 | 2nd | Rejected-Finance L2 | |
| 3 | 3rd₹8.0 L+₹15,781 (2.01%)Rejected-Finance | 3rd | Rejected-Finance L3 | |
| 4 | 4th₹8.8 L+₹95,780 (12.2%)Rejected-Finance | 4th | Rejected-Finance L4 | |
| 5 | Rejected-Technical 24 DH SCHEME NO 74 C VIJAY NAGAR INDORE INDORE MADHYA PRADESH 452001 | INDORE | MADHYA PRADESH | 452001 | - | Rejected-Technical Documents are not correct. |
Tender Value
₹9.9 L
EMD Value
₹19,858
Closing Date
7 Feb 2022, 6:00 pmClosed
GE AWC MHOW
GE AWC MHOW
MAINTENANCE AND REPAIR OF DESERT COOLERS, WATER COOLERS, REFRIGERATORS, DEEP FREEZERS, SPLIT/WINDOW/ CASSETTE/TOWER ACs AND CENTRAL AC PLANT WITH CONNECTED ITEMS UNDER GE (AWC) MHOW.
2022_MES_500388_1
8558 GE(AWC) /MHOW / OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AWC MHOW
All as per NIT and Tender Documents.
7 documents required · 7 mandatory
₹500
Yes
GE AWC MHOW
₹19,858
Yes
28 Mar 2022
8 Jan 2022
8 Feb 2022
10 Jan 2022
7 Feb 2022
24 Jan 2022
Amount
Repair/Maints/Servicing complaint from in respect of non functioning of any type of Air Conditioners of windows/ split type/ Cassette/Tower type of any capacity due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the AC by replacement/ renewal of air conditioners functional complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/articles renewed only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Taking down of old serviceable split AC of 1.5TR/2 TR capacity from site, taking out residual refrigerent gas from the split AC by cutting the CP pipes/ tubes carefully and shifting ,transporting , fixing, installing, commissioning and testing including charging with Non CFC refrigerant gas taken out from the existing AC and making connections fixing of all piping work alongwith its insulation complete all as specified and directed .
Taking down of old serviceable Window type AC of 1.5TR/2 TR capacity from site and shifting ,transporting , fixing, installing, commissioning and testing including charging with Non CFC refrigerant gas and making connections fixing of all piping work alongwith its insulation complete all as specified and directed .
Repair/Maints/Servicing of Non functioning of 1.5 /2 TR capacity ,any type of Air Conditioners of windows/ split type of any capacity by testing the leakage in system by filling of nitrogen gas upto 300 PSI and repairing of leakage spot/ joints with gas welding work , cleaning and flushing the complete system with gas, making the complete system leakproof, vaccumising and charging of gas Non CFC and testing on load including renewal of air filter complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/articles renewed and gas ( except air filter) only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips, PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Repair/Maints/Servicing of Non functioning of 4 TR capacity Air Conditioners Cassette type of any capacity by testing the leakage in system by filling of nitrogen gas upto 300 PSI and repairing of leakage spot/ joints with gas welding work , cleaning and flushing the complete system with gas, making the complete system leakproof, vaccumising and charging of gas Non CFC and testing on load including renewal of air filter complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/articles renewed and gas ( except air filter) only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Supply & fixing (in repairs) starting capacitor (conforming to IS:2993 - 1975) AC 230/270 volts in plastic container 80-100 mfd complete all as specified and directed .
Supply & fixing (in repairs) starting capacitor (conforming to IS:2993 - 1975) AC 230/270 volts in plastic container 100-120 mfd complete all as specified and directed .
M&L for renewal of running capacitor of plastic container of 36 Mfd capacity all as directed by EIC.
M&L for renewal of running capacitor of plastic container of 45 to 50 Mfd capacity all as directed by EIC.
S&F in repairs Thermostate switch for 1.5 TR / 2 TR Window type AC all as directed by EIC.
S&F discharge copper pipe line heavy duty 3/8"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F discharge copper pipe line heavy duty 1/4"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S&F discharge copper pipe line heavy duty 1/2"dia with puff insulation and flair nuts from indoor to outdoor unit of spilt AC 1.5 / 2 TR capacity all as specified and directed.
S & F( in repairs) PVC pipe nylon imbraided 15 mm dia for condensed water drain fitted with clamps/concealed in wall all as specified and directed.
S & F in replacement condensor unit suitable for 1.5/2 Ton capacity split AC of existing make and model complete all as specified and directed.
Dismantling of burnt blower motor of 1.5 TR window AC and supply & fixing new blower motor, double shaft, 1/5 HP (Suitable for Carrier/Voltas/Climiatzer make AC) as per sample complete including blower & condensing all as specified and directed.
Dismantling of burnt blower motor of 2.0/ 1.5 TR split AC( outdoor unit) and supply & fixing new blower motor as per existing HP (Suitable for Carrier/Voltas/Climiatzer make AC) as per sample complete including blower & condensing all as specified and directed.
S&F in repair oscilliating motor for indoor unit of split AC suitable for capacity 1.5 Ton/2 Ton complete all as specified and directed.
Dismantling of burnt blower motor of 4 TR Cassette type AC( outdoor unit) and supply & fixing new blower motor as per existing HP (Suitable for Carrier/Voltas/Climiatzer make AC) as per sample complete including blower & condensing all as specified and directed.
S&F in repair oscilliating motor for indoor unit of Cassette type AC suitable for capacity 4 TR complete all as specified and directed.
Dismantling of unserviceable compressors of 1.5 TR capacities including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type ( or Rotary type or hermetically seal unit) with and including initialy charged gas with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC.
Dismantling of unserviceable compressors of 2 TR capacities including disconnecting suction / discharge copper tubing and S&F compressor reciprocating type ( or Rotary type or hermetically seal unit) with and including initially charged gas with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC.
Dismantling of unserviceable compressors of 3TR capacities including disconnecting suction / discharge copper tubing and S&F compressorreciprocating type ( or Rotary type or hermetically seal unit) with and including initially charged gas with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas Non CFC complete all as directed by EIC.
Dismantling of unserviceable compressors of Cassette type 4 TR capacities AC's including disconnecting suction / discharge copper tubing and S&F compressor rotary type (cruise type) with and including initialy charged gas with nuts, bolts, rubber grommet and washer, connecting copper tubing by welding, flare nuts, rectifying leak and repairs if any, flushing by nitrogen & etc, Vacuumising, charging with refrigerant gas R-22, Mineral oil 3 Ph 50Hz 380-415V complete all as directed by EIC.
S&F in repairs air filter suitable for window type air conditioners complete all as specified and directed.
S&F in repairs air filter made out of Nylone suitable for 1.5TR/2 TR split AC capacities air conditioners of any existing make.
Dismantling of defective worn out wiring of indoor unit of split AC of capacity 1.5 TR / 2 TR including unserviceable corded electronic remote control, supply and fixing new control wiring and corded electronic remote control to suit / match the existing system all as specified and directed by EIC.
Dismantling of defective worn out wiring of cassette type AC of capacity 4 TR including unserviceable corded electronic remote control, supply and fixing new control wiring and corded electronic remote control to suit / match the existing system all as specified and directed by EIC
Supply & fixing (in repairs) Renewal of PCB ( Printed circuit Board) of split type air conditioner of existing shape and size and instalation in position to make the remote control system functional complete all as specified and directed.
Supply & fixing (in repairs) Renewal of PCB ( Printed circuit Board) of Cassette type 4 TR outdoor PCB air conditioner of existing shape and size and instalation in position to make the remote control system functional complete all as specified and directed.
Supply & fixing (in repairs) Renewal of PCB ( Printed circuit Board) of Cassette type 4 TR indoor PCB air conditioner of existing shape and size and instalation in position to make the remote control system functional complete all as specified and directed.
Supply & fixing in replacement blade for blower motor of existing make and model suitable for split/window type AC 1.5/2 Ton capacity complete all as specified and directed.
Supply & fixing (in repairs) 3 phase Contactor switch for Cassette type AC's, 4 TR capacity all as specified and directed by EIC.
Supply only refrigerant gas R-22/410/32 in returnable sealed cylinder all as specified and directed by EIC.
Supply only refrigerant gas R-134 ( Non CFC) / R-407C in returnable sealed cylinder all as specified and directed by EIC.
Supply & fixing (in repairs) Renewal of rubber ring of blower motor for window type Air conditioners of 1.5 TR capacity of existing shape and size and installation in position complete all as specified and directed.
S&F starting relay for blower motor of existing make and model suitable for split/window type AC 1.5/2 Ton capacity complete all as specified and directed..
S&F thermal overload relay for blower motor of existing make and model suitable for split/window type AC 1.5/2 Ton capacity complete all as specified and directed..
Supply & fixing (in repairs) front grill cover of window type AC'S with filter suitable for 1.5 /2 Ton AC of blue star/Carries/Samson/LG complete all as specified and directed.
Dismantling of defective air curtain motor suitable for 1200mm span of any make capacity transporting the same to contractors workshop for rewinding with super enamelled copper wire of suitable gauge as per manufacturer pattern including varnishing etc complete and refixing after testing complete to its original position including servicing of rotor and bearing etc. complete all as specified and directed.
Taking down air curtain of 1200mm span for servicing and overhauling by oiling and greasing of blower motor and cleaning by electrical motor including renewal of unserviceable bearings, repairing to shaft to make the air curtain functional complete and fixing in position and testing all as specified and directed.
Repair/Maint/Servicing of non functional water cooler of any capacity due to any fault including checking the serviceability of all parts, leakage if any, repair/ brazing to capalary tubing, stopping leakage from water connections, loose electric connections, cleaning flushing to condensing coil and checking of blower motor etc. and making the water cooler serviceable. Note:- (i)Parts/ accessories/articles renewed only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers etc. shall be deemed included in the unit rate quoted by Contractor.
M&L for preparation and scraping old surfaces of water cooler body of any capacity and spray painting with two coats of synthetic enamelled paint of approved quality after filling a cavity with metal filling materials including necessary welding work of Bottom portion with Provn of angle iron frame, PGI sheet etc and made the bottom rusted part in good condition and writing S M No with white/ Black colour paint all as specified and directed.
Supply & fixing (in repairs) replacement of PVC sprinkle nozzles of size 15 mm dia heavy duty complete all as specified and directed.
Supply & fixing (in repairs) replacement of water pressure gauge with 3/8" brass sampling nozzle of size 7 kg/10 kg pressure of dia 100 mm complete all as specified and directed by the Engr-in- Charges.
Renewal of condenser fan motor of water cooler of 40 to 180 litre capacity complete all as specifiedand directed.
Renewal of condenser fan blade of water cooler of 40 to 180 litre capacity complete all as specifiedand directed.
Dismantling of unserviceable compressor up to 80 litre capacity any make/brand ( Make Emmerson Model HR-13) or equivalent of other specified make from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with initially gas filled with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vaccumising, charging with non CFC refrigerant gas matching with R-134, of following capacities and make & Model complete all as directed by Engineer-in-Charge.
Dismantling of unserviceable compressor of 120 to 180 litre capacity any make/brand ( Make Kirloskar Model No CAJ 2612/AE4440M) or equivalent of other specified make from water cooler including disconnecting suction / Discharge copper tubing and supply & fixing new compressor (sealed unit) with initially gas filled with nuts, bolts, rubbers grommet and washer, connecting copper tubing by welding flare nuts, detecting leak and repairs if any flushing and pressure testing by nitrogen & etc. vacuumising, charging with non CFC refrigerant gas matching with R-134, of following capacities and make & Model complete all as directed by Engineer-in-Charge.
Renewal of PVC sheet rubber beading of water cooler top cover of any capacities of by screwing the same to make the cover air tight/ insect proof complete all as specified.
Supply & fixing (in repairs) CP Brass push cock (inner or outer threaded) of 15 mm bore size long noze medium size complete all as directed by the Engineer-in-Charge.
Supply & fixing (in repairs) starting relay for 40 to 180 ltr capacity water cooler complete all as specified and directed .
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 4 mfd /10 mfd capacities complete all as specified and directed.
Supply & fixing (in repairs) running capacitor (conforming to IS:2993 - 1975) AC 440 volts in plastic container of 15 mfd capacities complete all as specified and directed.
Taking out existing water tank from water cooler, tracing out leakage, removing leakage by gas welding / brazing etc. and making the tank leak proof including testing complete all as specified and directed.
Renewal of rubber hose pipe of 25mm bore with mild steel clamp with nuts and bolts for waste water outlet 1.5 M long complete all as specified and directed.
Renewal of capacitor for blower motor of water cooler of suitable capacity all as specified and directed .
S&F ( in repairs) float valve , 15 mm bore of brass with nipple and polyethylene float ball complete all as specified.
Repair/Maint/Servicing of non functioning of desert coolers due to any defect and checking electric connection, pumps, PVC pipe and distributor, tightening the loose connections and renewal of PVC pipe and PVC elbow etc. and making the cooler functional complete all as specified and directed.
Supplying and fixing ( in repairs) mild steel brackets ( arms) set of four pieces with clamps , washers, rubber bush and nuts/ bolts to match with the existing complete all as specified and directed.
Taking out carefully 325 to 500 mm sweep desert cooler from its existing position from stand/ walls or pillar, removing the side panels, taking out wool wood pads or loose pads and disposed to a distance not exceeding 50 metres away as directed by EIC and spray painting with synthetic enamel paint of approved colour outside after preparation of old painted surfaces and reassembling including renewal of minor items i.e. PVC distributor, PVC nozzles and PVC pipe as required and fixing in position, writing MES No with thick synthetic enamel paint 25 mm size of letters, figures etc. complete all as specified. Note:- Wood pads shall be measured separately.
S&F ( in repairs) Renewal of wood wool pad of desert coolers suitable for 325 to 500 mm sweep complete.
S&F ( in repairs) Renewal of PVC front grill complete with indicator switch and regulators all as directed by EIC .
S&F ( in repairs) Renewal of iron front grill made out from PGI sheet 22 gauge complete with indicator switch and regulators all as directed by EIC.
S&F ( in repairs) Renewal of polycarbonate Plug top 3 pin, 6 A, cat No. 38626/ 3982 of Anchor or equivalent of other specified.
S&F ( in repairs) Renewal of desert cooler body complete with PVC distributor, PVC nozzles and pipe, suitable for 450 mm/500 mm sweep exhaust fan /kit, made out of 22 gauge PGI sheet and side panels set of three duly filled with Khas khas including deassembling the fan, pump and its connected fittings, grills, regulator and cable etc.from wornout body and fixing the same renwed Cooler Body complete all as specified and directed.
M&L renewal of fan motor, single phase, 230 volt AC, complete with blade arm for 20" sweep size suitable for desert cooler all as specified and directed by EIC.
Supply and fixing in repairs submersible pump for desert cooler single phase, 1/40 HP, 230 volts complete all as specified.
Supply and fixing fan blade set for desert cooler single phase , 230 volts complete all as specified.
S&F ( in repairs) side panel made of 22 gauge MS sheet galvanized set of three for desert cooler complete all as specified.
Supply and fixing capacitor 4/6 mfd for desert cooler single phase , 230 volts complete all as specified.
Supply and fixing switch piano type 5 Amp, single pole for desert cooler single phase , 230 volts complete all as specified.
Supply and fixing regulator switch of 3 speed for desert cooler single phase , 230 volts complete all as specified.
S&F ( in repairs) Metal clad plug and socket assembly 20 A, DP complete all as specified and directed.
S&F (in repairs ) PVC insulated and PVC sheathed 3 core copper conductor flexible round cable size 2.5 sqmm all as specified and directed .
Repair /Maints/Servicing of refrigerator/ deep freezer in respect of non functioning of refrigerators / deep freezer due to any defect i.e. gas leakage, no power supply, low pressure, no cooling unserviceablity of compressor or any other part all as specified and directed by EIC.
M&L for renewal of sealed unit Compressor suitable upto 165 litre capacity refrigerator and deep freezer duly charged with initially filled refrigerent non CFC charged including necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of sealed unit Compressor suitable for 300/320 litre capacity refrigerator and deep freezer duly charged with initially filled refrigerent non CFC charged including necessary brazing work to make the system leak proof complete all as specified and directed.
M&L for renewal of fan motor of deep freezer of suitable size complete all as specified and directed
S & F over load protector suitable for refrigerator of capacity 165 to 300 litres all as directed by Engineer-in-Charge.
S & F in repairs thermostat defrost type for refrigerator all as directed by Engineer-in-Charge.
S & F (in repairs) Renwal of electric lamps, 15 watts, 230V, 50 Hz screw/ pin type as per existing Make.
S & F in repairs rubber door gasket magnetic type for Refrigerator of 165 to 300 litres capacities all as directed by Engineer-in-Charge.
Supply & fixing ( in repairs) vegetable basket with glass suitable for refrigerator of 165 to 300 litres capacities all as specified and directed by Engineer-in-Charge.
Supply & fixing ( in repairs) shelves suitable for refrigerator of 165 to 300 litres capacities as per site requirement all as specified and directed by Engineer-in-Charge.
Supply & fixing ( in repairs) Drain pump for cassette type Ac's capacities of 4 TR, 220-240V, 50/60Hz all as specified and directed by Engineer-in-Charge.
M&L for Repair overhauling of exahaust system installed at 'B' Mess including check of all vents, leakage & water pipe lines etc complete all as specified and directed EIC.
Taking out the old unserviceable winding and cleaning the slots of motor capacity 20 HP and rewinding the same with PVC insulated copper wire of existing gauge ,weight, size etc complete including all insulations, varnishing, heating etc and making all connections & testing to make it functional complete all as directed .
M&L for Replacement of unservicable rubber belt NO- 105/106 all as directed by Engineer-in-Charge.
S & F MCCB 4P ,415 Volts 25 KA 40-100 Amps complete all as specified and directed.
S & F MCB SP, C- Curve ,230 Volts 10 KA 6-32 Amps complete all as specified and directed.
S & F single pole and neutral sheet metal enclosure with 2 pin and earth plug and socket with 1 single pole MCB 20 Amp.
S&F (in repairs ) PVC insulated and PVC sheathed 3 core copper conductor flexible round cable size 1.5 sqmm all as specified and directed .
M&L for Repair of unservicable star delta motor starter suitable for 20 Hp motor complete all as specified and directed EIC.
S&F insulation for copper tube of split/Tower/cassette type Ac of capacity 1.5 to 4 ton complete all as specified and directed.
Repair/Maints/Servicing of cold storage room ( plus temperature and minus temperature ) of 'B mess' due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the cold storage functional by replacement/ renewal, complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/regrigerant gas/articles renewed only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Taking out the old unserviceable winding and cleaning the slots of centrifugal pump motor, 5 HP to 7.5 HP and rewinding the same with PVC insulated copper wire of existing gauge ,weight, size etc complete including all insulations, varnishing, heating etc and making all connections & testing to make it functional complete all as directed .
Desclaing of condenser unit by using cleaning solution, HCL, Sulphuric Acid, shoftner chemical, circulating pump, descaling brush, shoue, hand gloves, flange gaset, rubber insertation gasket etc. of capacity 37.5 TR chiller complete all as specified & diected.
Repair/servicing of hot water generator pump & motor of capacity 1 Hp complete all as specified & diected.
Repair/servicing of hot water generator capacity 54 Kw including replacement of unserviceable element complete all as specified & diected.
Servicing of pump & motor of capacity 5 Hp to 7.5 Hp complete all as specified & diected.
Repair and servicing of chiller plant panel of capacity 37.5 TR, cleaning all contactors and removing damaged electric cable and rewiring with the same gauge new copper wires and make functional complete all as specified and directed. Note- All should be done by specialised refrigeration mechanic.
Maintenence/Servicing complaint from in respect of non functioning of Air Conditioner plant of 37.5 x 2 TR capacity due to loose electrical connections,no power supply, gas leakage or any other minor default / defects, identifying and rectifying the defects and making the Plant functional and checking of all meters and make them functional complete all as specified and directed by Engr-in-Charge. Note:- (i)Parts/ accessories/articles/gas renewed only shall be measured and paid separately under appropriate items).However minor items like nuts, bolts, washers, tapes,nails, screws, Aluminium clips,PVC rawl plugs/ sleeves, connector block, clamps, Aluminium lugs, etc. shall be deemed included in the unit rate quoted by Contractor.
Repair/servicing of cooling tower tank with removing of small leakage (sump FRP) of suitable size including foot valve and cleaning of fins by chemical complete all as specified & diected.
Servicing/ cleaning of AHU filter of suitable size complete all as specified & diected.
Replacement of AHU filter of suitable size complete all as specified & diected.
M&L for writing with 2 inch wide letters of SM/MES No.- as per sample on the central Ac plant/ Acs / Desert cooler / Water cooler / Refrigerator / Deep freezer etc complete all as specified and directed. Note- Writing upto 30 nos. letters count will be counted as one job.
Replacement of section stainer Y type of suitable size of central ac plant complete all as specified & diected.
Ganga Enterprises
Vinayak Trading House
shanti electricals
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .