| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹40.8 LRejected-Finance ARRORIAN STREET DISTT PATIALA | 1 | Rejected-Finance Rejected due to higher | |
| 2 | 2₹41.5 L+₹67,441 (1.65%)Rejected-Finance 125 WARD NO 4 KARKHANA NO 1 DHURI PIN 148024 DISTRICT SANGRUR | DHURI | SANGRUR | PUNJAB | 148024 | 2 | Rejected-Finance Rejected due to higher |
Tender Value
₹34.6 L
EMD Value
₹69,300
Closing Date
29 Dec 2021, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Ranbir Club Sangrur
PROVIDING IMPROVED ACCESS TO WATER THROUGH HOUSEHOLD CONNECTIONS IN EXISTING VILLAGE
2021_WSS_79111_1
WSSD/2021-22/72
Open Tender
Civil Works
Item Rate
90 days
Sangrur
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹69,300
21 Jan 2022
13 Dec 2021
29 Dec 2021
13 Dec 2021
29 Dec 2021
13 Dec 2021
90 days
Amount
Tubewell
Drilling of 500 mm dia bore with Reverse Rotatry Rig in all kinds of soil including the cost of consumable stores, fuel oil and transportation of rig to the site complete in all respect.
up to 140 mtr
Supplying, lowering of MS Pipe as per IS: 4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore.
200mm nominal diameter (weight 33.6 kg per metre) 6.4mm thickness
Supplying, fixing of lowering of Stainless Steel Cage type wire wound screen as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
(s) 200mm Steel Strainer (slot size 0.75mm) 6.30 mm thickness
Supplying, fixing and lowering of Stainless Steel Socket as per IS: 8110-2000 or latest ISI Marked, Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore complete in all respect
200 mm internal diameter
Supplying, Lowering & fixing of M.S. special socket to connect S.S. Strainer to M.S. Pipe duly welded with suitable grade welding electrode complete in all respect.
200 mm internal diameter
Supplying at site Wooden box of suitable size with Lid & locking arrangment for preserving strata sample collected from the bore.
Drilling of 9” trail bore with hand boring machine including rate for electric logging ( electric Logging shall be carried out by contractor up to full depth) complete in all respect. Water sample of water wearing strata which are suitable for pumping out water shall be tested for physically & chemically analysis heavy metal & uranium. The rates for testing will be separate paid against Tube well relevant item of this bid. cared
Collection of water samplbe from different strata and testing of sample from approved laboratory (Phisical & chemical Analysis)
Supplying and fixing M.S well cap having thread to fix on housing pipe complete in all respect
200 mm internal diameter
Supplying & fixing of ball plug of M.S. pipe complete with inverted U-hook attached to the bottom plug complete in all respect.
(c) 200mm internal diameter (weight 33.6 kg per metre) 6.40 mm thickness
Supplying & fixing of M.S. Clamp of size 150mm x 12mm made out of MS Flat 1.52 m long, suitable to fit Housing pipe including the cost Nut & Bolts of Suitable size complete in all respect.
Development of stabillizing of the tubewell with air compressor of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Capacity of Air compressor 300 cfm at 250 PSI
Development of stabillizing of the tubewell with submersible pump of required capacity as directed by the engineer-in-charge including cost of tools, appliances & consumable to the satisfaction of Engineer-in-charge.
Supplying at site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore. The gravel should be free from dust, dirt or the vegetable manner as per IS 4097/1967 with latest amendments (to be paid as per acual length of pipe)
Ceiling of unpotable strata.
Testing of water sample for Heavy metal/Uranium from approved laboratory (Toxic material such as Arsenic, lead, mercury, pesticide etc.)
Making electric Logging of borehole with electronic well logger including cost of equipment at site etc. Complete in all respect
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respect.
Providing and fixing sanitary seal, clasy seal and sterilization of well on completion of tubewell as per BIS: 2800: 2019 complete in all respact
Providing Local sand
Pumping Machinery
Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set of reputed Make capable of delivering 301 LPM against a head of 77 mtr (minimum 12.50 BHP) along with electric panel board consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. including M.S. Column Pipe of suitable size minimum 65 mm =57 mtr (in 3 mtr lengths each with flanges , screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable 4 mm2 = 120 mtr. +(60 Extra Submersible Cable 4 mm2( Cable for both side including PVC Pipe excavation) (reputed make) complete in all respects as per standard Specifications. Including Non-return valve, SS Pressure gauge, gravel pit , GM ferrule for C.I fitting outsite Pump Chamber complete. & CONSTRUCTION OF V-NOTCH HAUDI.(size1.80 m x 0.90 m) including cost V-notch Complete in all respect
Repair of Expansion Joint including cost of labour and material complete in all respact.
Size 80 mm i/d
Size 100 mm i/d
P/F OHSR Jali including cost of labour and material complete in all respact.
CI Cover of OHSR including cost of labour and material complete in all respact.
Repair of OHSR stair case railing and pickets including cost of labour & material complete in all respects.
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
P/F aluminum ladder in side the OHSR as per standard design complete in all respect
P/F iron ladder out side the OHSR as per standard design complete in all respect
Repair of leakage of OHSR including material including cost of labour and material complete in all respact.
Cleaning of OHSR tank.
Crediy of old Sluice Valves
Pumping main
Providing, Laying, fixing & jointing of P.V.C pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specificationa.(15 mtr For Bye Pass)
110 mm o/d 10 kg cm2 pipe
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge)
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department (size 0.9m x 0.9m (including cost of Carriage) (For New & Existing Water Works)
Distribution
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for less than 3 mtr street width. included excavation.
PVC pipe 63mm o/d 6Kg/sqcm
Providing, Laying, fixing & jointing of PVC Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing including excavation & back filling complete as per specifications for more than 3 mtr street width.included excavation.
PVC pipe 63mm o/d 6Kg/sqcm
PVC pipe 75mm o/d 6Kg/sqcm
PVC pipe 90mm o/d 6Kg/sqcm
PVC pipe 160mm o/d 6Kg/sqcm
Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
Dismantling of Flexible Pavements (Bituminous Courses) (By Manual Means)
Dismantling of bituminous courses of flexible pavements by manual means and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately as per technical clause 202 of MORT&H specifications
PVC pipe 63mm o/d
PVC pipe 75mm o/d
PVC pipe 90mm o/d
PVC pipe 160mm o/d
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in - charge)
Providing, Fixing & jointing Cast Iron Surface box for Sluice Valve, Air Valve, Fire hydrant etc. including all carriages complete.
Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department.
Size 0.6 m. x 0.6 m.
Size 0.9 m. x 0.9 m.
Hand boring horizontly for crossing of pipe under road or any other obstacle by using Auger/Bocki method including excavation,stringing and jointing of pipe upto 160mm complete.
water connection
Providing proposed water connection to house hold up to wall with providing, laying jointing, testing MDPE pipe lines 15mm i/d=2.000 mtr & 2.50 mtr G.I Pipe, including cost of specials such as tees, bends, sockets, elbow etc. cutting, threading, and testing in trenches in the ground and ISI marked 15mm i/d GM ferrule as per IS: 2692 and 3'' i/d clamp with c.i. bib cock 15mm i/d as per IS:210 with stainless steel spindle of approvel make as per CSR 30.65 (b) Including cost of dismantling brick paving /CC flooring & relaying the same original condition in complete respect
Improvement in Existing connections on existing pipe including cost of labour & material complete in all respects.
Chlorinator
Providing, Installing, testing & commissioning one No. Electronically actuated, Diaphragm Operated, Metering Syatem, Chemical Dosing Chlorinator, suitable for delivering 0.5 to 6 Litres of Bleaching powder solution/ Sodium Hypo Solution per hour under maximum delivery pressurSe upto 7 kg.cm 2 and suction lift not less than 1.5 m, as per DWSS standard specifications.
Repair of Pump Chamber
Scraping of Cement plaster
12.5 mm thick cement plaster 1:4
Scraping of White washing inside of Pump Chamber
Scraping of snowcem robbiacem etc.
White washing 2 coat inside of Pump Chamber
Finishing Wall with exiterior decorative cement based paint such as snowcem robbiacem etc. on new work in two coats to give even shade.
Hollock wood Door windows including Hinges, Screws, Chocks Cleats, Stops and Cords etc. complete fixed in position (double Leaf) @ Paneled glazed or glazed and paneled
Supplying & fixing glass panes including special metal sash putty of approved make.
Congolmerate floor 40mm thick cement concrete 1:2:4 on 100mm thick cement concrete 1:8:16 and 100mm sand as stone filling for plinth protection.
Conglomerate floor 50mm thick cement concrete topping 1:2:4 using mechanical mixer for mixing of material
BALJIT KUMAR CONTRACTOR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .