REPAIR/MAINTENANCE/REPLACEMENT OF LT UG CABLES, OVER HEAD LINES, POLES, LT PANELS, MCCBS, JOINTS AND CONNECTED ITEMS AT D-IB ZONE UNDER AGE E/M -1 OF GE (NORTH ) MAMUN
2021_MES_479251_2
GE(N)/M-48/2021-22
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹40,000
18 Jan 2022
13 Nov 2021
29 Nov 2021
13 Nov 2021
27 Nov 2021
13 Nov 2021
Amount
Dismantling old unserviceable steel poles/Strut any size and shifting n.exceeding 50 meters for setting aside for disposal action complete all as specified and directed.
M&L for steel tubular swaged pole 09 mtr long with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP 31, painted with two coats of aluminium paint over a shop coat of primer including 30 cm strip painting in alternate colour with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
Dismantling old unserviceable concrete pole/Strut any size and shifting n.exceeding 50 meters for setting aside for disposal action complete all as specified and directed.
M&L for prestressed cement concrete pole 9 mtr long, 102 mm x 172 mm at top and 102 mm x 289 mm at bottom Class-10 complete, erected truly in vertical position and painting the poles with alternate layer of 30 cm with synthetic enamel paint upto 1.5 mtr above from the coping complete all as specified and directed.
Taking out cable LT 1100 volts grade, heavy duty aluminium conductor of size 10-16 Sqmm, any core from trenches, wall pole or pipe for rectification of faults or replacement including seggregating serviceable/un-serviceable cable and stacking aside for reuse or removing to MES store for disposal action. Note: Earth work shall be measured and paid separately under respective item of BOQ.
All as per Srl Item 5 but of size 25-35 Sqmm
All as per Srl Item 5 but of size 50-70 Sqmm
All as per Srl Item 5 but of size 95-120 Sqmm
All as per Srl Item 5 but of size 150-185 Sqmm
All as per Srl Item 5 but of size 240 Sqmm
Laying, connecting and testing retrieved serviceable cable of size 10-16 Sqmm all as specified and as directed. Note : Cable termination lugs shall be provided for connecting cable without any extra cost.
All as mentioned in item No 11 but cable size 25-35 Sqmm
All as mentioned in item No 11 but cable size 50-70 Sqmm
All as mentioned in item No 11 but cable size 95-120 Sqmm
Supply, laying, connecting, commissioning and testing in replacement XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 Volts grade, cross sectional area 240 Sqmm, 3.5 core connected with cable termination kit complete all as specified and directed. Note: Cost of cable termination kit shall be measured and paid seperately under respective item of BOQ.
All as per Item No 15 but Size 185 sqmm 3.5 core
All as per Item No 15 but Size 150 sqmm 3.5 core
All as per Item No 15 but Size 120 sqmm 3.5 core
All as per Item No 15 but Size 95 sqmm 3.5 core
All as per Item No 15 but Size 70 sqmm 3.5 core
All as per Item No 15 but Size 50 sqmm 3.5 core
All as per Item No 15 but Size 35 sqmm 3.5 core
All as per Item No 15 but Size 25 sqmm 4.0 core
All as per Item No 15 but Size 16 sqmm 4.0 core
All as per Item No 15 but Size 10 sqmm 4.0 core
All as per Item No 15 but Size 10 sqmm 2.0 core
Taking up/down service connections, PVC insulated aluminium stranded conductor of size 6/10 sqmm any core suspended by insulating hangers including suspension wire and shifting to MES store for further disposal actioncomplete complete all as specified and directed.
Supply, laying, connecting and testing PVC insulated aluminium stranded conductor, 6 Sqmm, 2 core, 1100 Volt grade heavy duty served with inner sheathing of PVC tape and overall PVC sheathed one twin core cable flat or circular in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire,complete complete all as specified and directed.
All as per item No 28 but cable size10 sqmm 2.0 core
All as per item No 28 but cable size 16 sqmm 2.0 core
Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed. Note :- (i) The overhead lines shall be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission shall be obtained from department by contractor one day prior to trimming in particular area and shut down of that area shall be arranged by department. (ii) Distance between two LT poles shall be measured as one span for the purpose of payment, irrespective of the No of trees required to be trimed. (iii) Fortnightly inspection of lines shall be made jointly by contractor / his authorised rep and rep of Engr-in-Charge. Out come whether lines are free from tree branches or otherwise shall be kept on records for payment payment purposes. (iv) The OH line shall be maintained for whole period of contract. Payment of this item shall be made under final bill only. (v) The payment for the period for which line is not maintained shall be deducted proportionately based on fortnightly inspection carried out as detailed above.
S&F in replacement GI strip 32x6 mm complete with saddles/ insulators made out of porcelain or fiber and buried in ground or fixed to wall etc for loop earthing including taking out old strip complete all as specified and directed.
M&L for Cable straight through/end termination jointing kit, heat shrinkAble, 1100 volts grade complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 25-35 sq mm, 2/3.5/4.0 core complete all as specified and directed.
All as per Item No 33 but size 50 sq mm, 3.5 core
All as per Item No 33 but size 70 sq mm, 3.5 core
All as per Item No 33 but size 95 sq mm, 3.5 core
All as per Item No 33 but size 120-150 sq mm, 3.5 core
All as per Item No 33 but size 185 sq mm, 3.5 core
All as per Item No 33 but size 240 sq mm, 3.5 core
Supply and fixing in replacement of GI tubing, light grade 25 mm bore with fittings laid for protection of cable under road crossing fixed to walls or pole complete all as specified and as directed.(clAmps for fixing pipe, nuts, bolts washers shall be measured separately )
All as per Item No 40 but 40 mm bore
All as per Item No 40 but 50 mm bore
All as per Item No 40 but 80 mm bore
All as per Item No 40 but 100 mm bore
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use or for disposal action complete all as specified and directed.
Fixing only serviceable cross arms items retrieved from item No 45, applying one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M&L for Cross arms, bracings, supports, clAmps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
Dismantling ACSR conductor of LT OH line after unbinding from insulators for replacement/re-stringing of damaged conductors including seggregating serviceable/unserviceable conductors for re-use or for disposal complete all as specified and directed.
Restringing of dismantled aluminium conductor retrieved from item No 48 on LT OH line with new aluminium binding wire including stretching with 3% sag, re-connecting of all cables disconnected jumpers with proper jointing with binding wire complete all as specified and directed.
M&L in replacement ACSR of LT OH line including securing with insulators using aluminium binding wire, jointing jumpers etc including all disconnected cables, jumpers with proper binding complete all as specified and directed.
Dismantling earth wire from LT OH line after unbinding from pole for re-use or for shifting to MES store for taking credit to contractor complete all as specified and directed.
M&L for Galvanised steel earth wire of service feeder or distributor span of LT poles including binding with insulators using GI binding wire, jointing jumpers etc complete all as specified and directed.
Dismantling and taking old/UNSV stay assembly including stay wire and insulator complete all as specified and directed.
M&L for Stay assembly complete with accessories as shown in electrical plate No.1 of SSR Part-I, 2009 (stay clamp, stay wire, stay insulator, stay grips, galvanised thimble for wire 19mm dia, stay bow, stay-rod and stay-plate of 300x300x6mm size, 20 mm dia stay rod , stay bow, nuts, bolts and GI check nuts etc. complete all as specified and directed. Note : Excavation, PCC, stay clamp and loop type insulators will be measured separately under respective items of BOQ.
M&L in replacmement galvanized stay strand of 7/4mm size complete all as specified and directed.
Dismantling insulators of any type, any size complete all as specified and directed.
Fixing only shackle type insulators retrieved from item No 56 complete all as specified and directed.
Fixing only pin type insulators retrieved from item No 56 complete all as specified and directed.
M&L loop type insulator large size with overall dimensions (90 x140) mm with 25.5 mm dia hole, vitreous white brown or green complete all as specified and directed.
M&L shackle type insulator, 100 mm height, 115 mm dia, 31x5 mm strap,14 mm dia bolts Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers, insulator bolts, washers and nuts, ompletecomplete all as specified and directed.
M&L Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade complete all as specified and directed.
Dismantling LT panel from site by removing all cable connections, earthing strip/wires, floor/wall mounting supports including making good disturbed surface matching with existing surface and shifting for further disposal action complete all as specified and directed.
Supply, install, testing and commissioning in replacement LT feeder pillar box, outdoor type, floor mounted, made out of CRCA sheet 3.15 mm thick, CPRI approved, conforming to IEC 61439, weather proof, dust and vermin proof, IP -65, powder coated, with common elecrolytic, sleeve insulated Aluminium bus-bar 900 Amps, 3 phase 4 wire system, 415 volts AC, both sides openable, compartmentalised, double door and locking arrangements for each compartment, prewired with Copper cable not less thatn 1.5 sq mm, provided with danger notice plate, panel mounted on 50x50x6mm angle iron frame with leg 90 cm long, 30 cm embedded and secured in PCC foundation 1: 2:4 type B1 using 20 mm graded aggregate of size (700x300x300mm -02 Nos), size of panel shall suitable to accommodate and comprising the following components :- (a) MCCB 630 Amps, 4 pole,36 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer) (b) MCCB 250 Amps, 4 pole,25 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 02 Nos (c) MCCB 160 Amps, 4 pole,25 kA, 415 volts, 50 Hz withThermal Magnetic : O/L & S/C protection- 01 No (d) MCCB 63 Amps, 4 pole,16 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (e) MCB TPN 32 Amps, 16kA, 415 volts, 50 Hz - 01 No (f) MCB SPN 32 Amps, 16kA, 240 volts, 50 Hz - 01 No (g) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lAmps for phase indication (RYB)- 01 set Make of MCCB : Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL) Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item No 63 but busbar capacity 200 Amps and comprising the following components: (a) MCCB 63 Amps, 4 pole,16 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer) (b) Onload changeover switch, 4 pole,415 volts, 63 Amps -01 No (c) MCB SPN 32 Amps, 10kA, 240 volts, 50 Hz - 10 Nos (d) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set Make of Onload changeover switch : L&T/ABB /SIEMENS/C&S
All as per item No 63 but busbar capacity 200 Amps and comprising the following components: (a) MCCB 100 Amps, 4 pole,16 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer) (b) MCB SPN 32 Amps, 10kA, 240 volts, 50 Hz - 06 Nos (c) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set
All as per item No 63 but busbar capacity 300 Amps and comprising the following components: (a) MCCB 160 Amps, 4 pole,25 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer) (b) Onload changeover switch, 4 pole,415 volts, 160 Amps -01 No (c) MCCB 63 Amps, 4 pole,16 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 03 Nos (d) MCB TPN 32 Amps, 10kA, 415 volts, 50 Hz - 02 Nos (e) MCB SPN 32 Amps, 10kA, 240 volts, 50 Hz - 02 Nos (f) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set
All as per item No 63 but busbar capacity 300 Amps and comprising the following components: (a) MCCB 160 Amps, 4 pole,25 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (Incomer) (c) MCCB 100 Amps, 4 pole,16 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (c) MCCB 63 Amps, 4 pole,16 kA, 415 volts, 50 Hz with Thermal Magnetic : O/L & S/C protection- 01 No (d) MCB TPN 32 Amps, 10kA, 415 volts, 50 Hz - 01 No (e) MCB SPN 32 Amps, 10kA, 240 volts, 50 Hz - 01 No (f) Multifunction function meter (voltage,Amps ) including CTs and LED pilot lamps for phase indication (RYB)- 01 set
S&F in replacement MCCB 3 pole 415 volts , fixed type 25 Amps to 100 Amps, 16 kA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu, including spreadres complete all as specified and directed. Make: Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL)
All per item No 68 but 125 Amps
S&F in replacement MCCB 4 pole 415 volts fixed type 25-100 Amps with breaking capacity 16 kA, thermal release adjustable from 80 to 100% & fixed magnetic release with Ics = 100% Icu , including spreaders complete all as specified and directed. Make: Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL)
All per item No 70 but 125 Amps
All per item No 70 but 160 Amps
S&F in replacement MCCB 4 pole 415 volts, 200 Amps, 25kA, thermal release adjustable from 80 to 100% & magnetic release adjustable from 5 to 10 In with Ics-100% Icu, including spreaders complete all as specified and directed. Make: Schneider (NSX)/Legrand (DPX) /SIEMENS ( 3 VL)
All as per Item No 73 but 250 Amps
All as per Item No 73 but 350 Amps
All as per Item No 73 but 400 Amps
Excavating in trenches in soft / loose soil, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation of poles, trenches for laying of cable, or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
All as per item No 77 but n exc 1.5 m wide and exc 1.5 m and n exceeding 3.0 m in depth
Removing excavated material to a distance not exceeding 50 Mtr and deposting where directed at a level not exc. 1.5 mtr above the starting point.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each all as required and directed.
M&L for well burned bricks, laid flat (old size) sub class B designation 75 for cable protection with width equal to the width of brick complete all as specifed and directed.
M&L for sand cushioning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches and punned down (total 18cm punned thickness shall be measured) complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregrate for foundation filling as mass concrete including necessary form work complete all as specified.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregrate for coping of poles and foundation of stay complete all as specified.
S&F in replacement MCB SP 6-32 Amps, "B" grade, 10 kA, 240 volts AC. Make : Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item No 85 but 40-63 Amps
S&F in replacement MCB SPN 6-32 Amps, "B" grade, 10kA, 240 volts AC. Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item No 87 but 40-63 Amps
S&F in replacement MCB TPN 6-32 Amps, "B" grade, 10kA, 415 volts AC. Make of MCB: Legrand (DX3)/Schneider (Acti-9)/Siemens (Betagard)
All as per item No 89 but 40-63 Amps
M&L Current transformer 400 Amps rating, conforming to IS 2705:Part-I & II/IEC: 185 with latest amendments, suitable to fix on LT panel busbar, varnished with super enameled electrolytic grade copper wires, fiber glass tape insulated or cast resin, CT’s have marking and name plate as per IS 2705 in addition to class of insulation & ISF. The markings shall be indelible complete all as specified and directed.
All as per Item No 91 but 300 Amps
All as per Item No 91 but 200 Amps
All as per Item No 91 but 160 Amps
All as per Item No 91 but 100 Amps
S&F in repairs LED Pilot lamp, 240 volts AC (R/Y/B) fixed in LT panels with integral circuit including wiring as required complete all as specified and directed. Make: C&S/L&T/Schneider/ABB
M&L for spray painting on LT panel with two coats of synthetic enamel paint including preparation of old painted surface including writing all feeder name with capacity, with sticking incomer/out going of breaker complete all as specified and as directed
M&L for earthing complete with galvanised steel earth plate electrode, 600x600x6mm thick, buried directly in the ground (earth pit not less than 2.25m deep below normal ground level with top edge of plate not less than 1.50m below ground level connected to galvanized iron strip of 32x6mm as earth lead by means of bolts, nuts and washers of GI up to test point, GI light grade pipe 40mm bore as protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal and salt, 40mm thick pre-cast RCC (1:2:4) type B-0 (Nominal mix) cover reinforced with XPM (weighing n.less than 4 Kg/Sqm) with suitable steel handle, and angle iron 40X40X3mm frame and chamber of PCC (1:3:6) type C-0 (including earth work in any type of soil, removal of surplus soil to a distance n.exc.50m) and connecting, testing on completion, all as shown on electric plate No. 03 of SSR-2009 Part-I, complete all as specified and directed. Notes: 1. Earth strip & protection pipes length upto & including 7.50 metre is deemed included in unit rate quoted by the contractor. 2. Earth filling shall be done by vegitable soil. Soil shall be free from stone, boulders, aggregate, gravels. 3. On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost.
Deduct Total amount of SCHEDUL 'A' SECTION-II (SCH OF CREDIT) Rs 79,445.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum.
AGGARWAL ASSOCIATES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .