| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹33.8 L+₹1.4 L (4.38%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹34.7 L+₹2.3 L (7.09%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹35.0 L+₹2.6 L (7.90%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹35.4 L+₹3.0 L (9.26%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹42.5 L
EMD Value
₹85,000
Closing Date
14 Dec 2023, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
PROVN OF A TOILET BLOCK AT RECOVERY CAMP P COY TRG AREA 4 TECH TRG BN 3 EME CENTRE PROVN OF 01 GENERATOR WITH SHED FOR AUTO SCHOOL 2 TECH TRG BN 3 EME CENTRE PROVN OF BTY CHARGING SHOP AT 194 FD WKSP COY AND CERTAIN MW AT BAIRAGARH UNDER GE BHOPAL
2023_MES_628893_1
8212
Open Tender
Civil Works
Item Rate
183 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹85,000
Yes
14 Feb 2024
18 Nov 2023
16 Dec 2023
18 Nov 2023
14 Dec 2023
2 Dec 2023
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline
Surface excavation n exc 30 cm deep and averaging 15 cm deep and getting out in soft/ loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes, pier holes, etc. but n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed.
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in foundations including rafts, footings, foundation beams, plinth beams, base for columns and mass concrete etc complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts etc complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5 m span etc. complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregate) as in chajjas and similar work complete all as specified and directed.
M&L for reinforced cement concrete design mix M-25 (using 20 mm graded stone aggregates) in slabs supported on walls, beams & columns complete all as specified and directed.
Use and waste for formwork to sides of concrete foundation, footing, bases of columns, rafts, raft beam sides and soffits of foundation and plinth beam for flat rough finished concrete surfaces complete all as specified and directed.
Use and waste for formwork to sides of pillars, posts, struts, pier column for flat rough finished concrete surfaces complete all as specified and directed.
Use and waste for formwork to chajjas including edges for flat rough finished concrete surfaces complete all as specified and directed.
Use and waste for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. for flat rough finished concrete surfaces complete all as specified and directed.
Use and waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for flat fair finished concrete surfaces complete all as specified and directed.
S&F for mild steel TMT bars, 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F for mild steel TMT bars, 5 mm and over upto and including 10 mm dia as in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L for hard core of broken stone of gauge not exceeding 63 mm, deposited, spread & levelled in layers not exceeding 15 cm thick watered and rammed to a true surfaces complete all as specified and directed.
M&L for red bajri/ moorum filling including spreading, levelling, watering & well ramming, in layers not exc 15 cm each complete all as specified and directed.
M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (area of the sub structure in contact with backfill shall be measured) complete all as specified and directed.
M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed.
M&L for 100 mm thick plain cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) as in sub base for floor, finished even and rough complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4, type B-1 (using 20mm graded aggregate) as in levelling course in floors, finished even and rough to receive floor finish complete all as specified and directed.
M&L for 25 mm thick plain cement concrete 1:2:4, type B-1 (using 20mm graded aggregate) as in flooring finishing even and smooth with using extra cement complete all as specified and directed.
M&L for brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:6 complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on any face of brick work or concrete surfaces mixed with water proofing compound as per manufacturer's instruction & finished even and smooth without using extra cement complete all as specified and directed. (Note: Water proofing compound shall be measured and paid seperately)
M&L for 10 mm thick rendering in cement mortar 1:6 on any face of brick work or conrete surfaces/stone masonary, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound ISI marked complete all as specified and directed.
M&L for 10 mm thick rendering in cement mortar 1:3 on concrete surfaces as in ceiling, finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of newly plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a coat of cement based putty complete all as specified and directed.
M&L for preparation of newly plastered sufaces of walls and applying / finishing walls with remium acrylic smooth exterior paint with silicone additives of required shade: New work with two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm complete all as specified and directed.
M&L for preparation of newly plastered of ceiling surfaces and applying three coats of white wash complete all as specified and directed.
S&F of factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width struck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent cement supplying and fixing in the frame at site as per specification & drawing complete all as specified and directed.
S&F of solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube and fixing in opening as per manufacturer instructions complete all as specified and directed.
S&F of aluminium alloy, anodized sliding door bolt of 250 mm length with hasp and staple and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolt of extruded section or cast aluminium alloy complete all as specified and directed.
S&F of butt hinges, medium weight, mild steel of 100mm size and fixed with screws complete all as specified.
S&F of aluminum handles cast type, anodized of 150 mm size and fixed with screws complete all as specified and directed.
S&F aluminum anodised barrel tower bolt of 150 mm size, extruded section and fixed with screws complete all as specified and directed.
S&F of anodised aluminium powder coated sections (minimum thickness of powder coating 50 micron) as in doors, windows, ventilators, partitions, shutters and frames with or without sash bars including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, necessary fittings etc. complete all as specified and directed.
S&F of 4.8 mm thick frosted glass and fixed to doors, windows/ ventilators etc. complete all as specified and directed
M&L for 75 mm thick plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection, finishing the surface even and smooth without using extra cement laid in bays n exc 2 m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
Removing surplus soil obtained from excavation to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting paint complete all as specified and directed.
S&F of vitreous china wash down water closed pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) but including white plastic seat cover with aluminium hinging device complete all as specified and directed.
S&F of syphonic action type PVC low level flushing cistern of 10 ltrs capacity incl flush pipe and fixing to supply pipe including PVC connection 15 mm bore and 600 mm long with brass heads & washers with making connections complete all as specified and directed.
S&F 15 mm bore bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferulle and fixed complete all as specified and directed.
S&F 15 mm bore stop cock, cast copper alloy, chromium plated with long shank and cut (concealed type), screwed down, screwed for iron pipe or union and fixed complete as specified and directed.
S&F 15 mm bore stop angle cock, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or union and fixed complete as specified and directed.
S&F of vitreous china urinal, half stall type, white (excluding flushing cistern, flush pipe and waste pipe) but including brass cromium plated urinal spreader and fixed complete all as specified and directed.
S&F of wash basins, vitreous china (flat back or angle back type) of 630 x 450 mm size including cutting for and pinning in ends of brackets or erecting stand/supported on wall, fixed with and including waste pipe, waste coupling, 15 mm dia pillar taps cast copper alloy with capstan head chromium plated with long screwed shanks and fly-nuts, screwed for iron pipe 15 mm bore and fixed complete all as specified and directed.
S&F of PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified and directed.
S&F of brass chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flanges and fixed complete all as specified and directed.
S&F of 100 mm dia CP grating and fixed complete all as specified and directed.
S&F of stainless steel soap dish, any type, fixed with plugs with CP brass screws and fixed complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls/ laid in trenches/floors complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed in walls / laid in trenches/floors complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) junction single (Single T), equal or unequal and fixed with solvent cement complete all as specified and directed.
S&F of PVC (SWR) bends any radius 110 mm dia and fixed with solvent cement complete all as specified and directed.
S&F of PVC (SWR) bends any radius 75 mm dia and fixed with solvent cement complete all as specified and directed.
S&F of 75mm dia PVC (SWR) floor/nahani trap with CP brass grating including jointing with solvent cement complete all as specified and directed.
S&F of PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) vent cowl and fixed complete all as specified and directed.
S&F for chromium plated shower rose 125 mm with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
M&L for provission of water proofing roof treatment to non accessible RCC roof with APP modified membrane with non woven polyster reinforced of weight not less than 3 Kg/Sqm of thickness not less than 3 mm having thermal insulation with white mineral/ gravel or plain finish on upper side of membrane uniformely embedded during manufacturing process with and including comprising of following specifications:-
(a) Cleaning the surface of the roof, parapet and gutters, drain mouths etc. over which water proofing treatment is to be applied shall free from all foreign matters such as fungus, mass, dust etc. by wire brushing and dusting. For cast iron drain outlets the groove shall be cut around to tuck in the treatment as pipes, chimney stacs etc. and other similar situations to ease up about corners. (b) All joints and changes in direction should be curved with cement mortar 1:3 mixed with SBR latex @ 200 ml per bag of cement and curved well before laying the membrane. (c) Applying bituminous primer conforming to IS : 3384-1965 @ 0.30 Kg/Sqm on prepared surface till the surface is properly impregnated. (d) APP modified water proofing membrene as specified shall be laid by torch application method laid on hot bitumen 85/25 grade (bonding material) at the rate of 1.2 kg/sqm primer surface as per manufacturers instructions, the overlaps while torching shall be 100 mm in both directions (longititudinal and transverse directions). All overlap joints shall be sealed throughly by thermofusing both the membrene layers and sealing it with the help of hot trowel. The overlap joints shall be made as monolithic layer. (e) A fillet of PCC (1:2:4) type B-0 of 100 mm x 100 mm shall be provided at all junctions of vertical and horizontal surfaces and wherever there is a change of direction. The membrane should not be taken over at any steep turns and hence all corners /junctions should be rounded. (f) Providing 10 mm thick screed bed in CM 1:4 mixed with and including water proofing compound @ 3% by weight of cement applied over roof slab and the plaster is cured the roof will be tested for water tightening by ponding with water for 72 Hrs for any seepage / leakages etc. if any seepage is oberved the rectification will be carried out by pressure grouting under the pressure of 5 Kg/Sqcm using cement based cement grout. After the surface is repired the slab will be tested for watertightness against before processing further treatments.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors over and including 15mm thick screed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and directed
M&L for glazed ceramic coloured tiles in vertical surface such as dado, riser, skirting etc. of size 350x 250x 7mm/ 450x 300x 7mm thick, set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
M&L for granite stone work (any type) 18 to 20 mm thick (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms, counter, shelves and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in cement mortar 1:4 complete all as specified and directed.
S&F of 1000 Ltrs capacity rotational moulded polyethylene water stotage tanks, triple layer (cylinderical verticle with closed top) hoisted & fixed in position as specified in SSR Pt-I including 20mm bore brass ball valve complete all as specified and directed.
M&L for ceramic parking/ path tiles anti slip joint free coloured tiles 15 mm thick matte finish (Square/rectangular) area of each tiles n exc 0.36 Sqm as in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed. Make : Johnson/ Kajaria/ Orientbell
M&L for concrete bed to drain pipes 150 mm dia including packing under, and haunching against the sides of pipes after they are laid and tested in cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) complete all as specified and directed.
S&F of 150 mm dia RCC NP2 drain pipes laid in trenches and jointed in cement mortar 1:3 and testing complete all as specified and directed.
Returning, filling in any type of soil including spreading, levelling, watering and well ramming in layers n. exc 25 cm complete all as specified and directed.
Removing excavated material to a distance exc. 500 m but n exc. 1.5 km and depositing where directed at a level n exc 1.5 mtr above starting point complete all as specified and directed.
M&L for PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, coping, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chemfered angle and throating complete all as specified and directed.
M&L for precast cement concrete 1:2:4 type B-1 (using 20 mm graded aggregate) as in cover slab for manholes etc; and set in cement mortar 1:4 complete all as specified and directed.
S&F of mild steel TMT bars 6 to 8 mm dia bars, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F of LLDPE septic tank for capacity of 25 Users of conventional designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 type D-2 below foundation, vent shaft and making necessary connections as per site requirement complete all as specified and directed.
M&L for soakage wells excavation in ordinary soil, foundation in PCC 1:3:6 wells of honey combed and soild in M-25 concrete, including intercepting chamber, screen chamber brick work in CM 1:4, RCC cover slab in M-25/SFRC interconnecting pipes of RCC/DWC complete Filling with brick bats complete of size (1.8 m dia x 3.0 m effective depth) as per TD complete all as specified and directed.
Cutting into existing manholes/septic tanks for connecting new drains, making good to pipes and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section ) in cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) smooth finished, and reforming benching as required of 150 mm dia pipe complete all as specified and directed.
S&F of GI tubing medium grade with all necessary fittings and fixed to wall and ceiling or laid in floors complete all as specified and directed of following sizes:-
15 mm bore.
20 mm bore.
25 mm bore.
40 mm bore.
50 mm bore.
S&F of gun metal glove or gate valve, conforming to IS: 778 with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed of following sizes:-
20 mm bore.
25 mm bore.
40 mm bore.
M&L for clean dry sand cusion/ covering for protection of underground cables in trenches complete all as specified and directed.
M&L for sub class 'B' bricks locally available of best quality laid dry in trenches for cable protection complete all as specified and directed.
M&L for cutting PCC/floor/road of section n exc 0.3 x 0.3 m and making good in PCC 1:2:4, type B-I (using 20mm graded stone aggregate) after laying of pipe complete all as specified and directed.
Excavation in post holes in any type of soil (or similar holes) each n exc 0.5 cum and getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, incl removing of surplus soil complete all as specified and directed.
S&F rolled mild steel work as in rafter, purlins, trusses and like (beam, tee, angle, channel or flat sections (Fe 410-W(Gde E-250 quality) complete all as specified and directed.
M&L for preparation of new or previously untreated surfaces of steel and iron surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc chrome primer complete all as specified and directed.
S&F of 0.50 mm thick pre- painted galvalume aluminum zinc coating GI based corrugated steel sheeting of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas and fixed with self tapping screws complete all as specified and directed
S&F of 0.50 mm thick pre- painted galvalume aluminum zinc coating GI based plain steel sheeting of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, chajjas and fixed with self tapping screws complete all as specified and directed.
S&F for stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed complete all as specified and directed.
S&F for mild steel framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, framed guard bars, barred iron doors, ladders, framework of water tanks, and similar work confirming to Fe-290, Gde E-165 complete all as specified and directed.
M&L for ceramic acid resistant joint free coloured tiles 300 x 300 x 10-12 mm thick matte finish (Square/rectangular) area of each tiles n exc 0.36 Sqm as in floors etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed.
M&L for ceramic acid resistant joint free coloured tiles 300 x 300 x 10-12 mm thick matte finish (Square/rectangular) area of each tiles n exc 0.36 Sqm as in walls etc; set and jointed in neat cement slurry and pointed in white or coloured cement to match shade of tiles complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundations / mass concrete complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) with and including wearproof topping of 20 mm thick using approved metallic floor hardner in concrete floors and pavings, and finished even and smooth complete all as specified and directed.
M&L for concealed point wiring with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC Casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS PVC insulated, unsheathed, single core multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides including 2.8mm thick laminated hylem sheet cover, ISI marked for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washers complete all as specified and directed for the following points:- Note : Wiring to be done as per approved colour code in IE rule. Rate includes chase cutting for concealed wiring.
(a) One light point / fan/ exhaust fan/ bell point
(b) One 3 pin 5 Amp socket outlet on same board.
(c) One 3 pin 5 Amp socket outlet on independent board.
M&L for concealed point wiring for 3 pin 15 Amp socket outlet on independent board with 2.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC Casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS PVC insulated, unsheathed, single core multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly including sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides including 2.8mm thick laminated hylem sheet cover, ISI marked for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washers complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule. Rate includes chase cutting for concealed wiring.
S&F of switch piano flush type single pole one way 5 Amps complete all as specified and directed.
S&F of ceiling rose surface bakelite 65mmm dia, three terminal complete all as specified and directed.
S&F of lamp holder, PVC/polycorbonate type with back plate with and including LED bulb retrofit type 9/10 watts complete all as specified and directed.
S&F of LED light fitting 1 x 20 watts, 220 volt, AC, decorative box type with driver, holder including LED tube light and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F of LED mirror light fitting with high output diffuser 2 feet, 10 watts, 220 volt, AC, decorative type with driver, holder including LED light and connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F of 250mm sweep exhaust fan, steel body, AC single phase, 140-285 Volts with blades, frame and louvers including connecting with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
M&L for sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 4.0 Sqmm drawn in and including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 4.0 Sqmm (Green colour) as earth continuity conductor cable connected to earth dolly complete all as specified and directed. Note: Three runs of cable shall be measured as a single length.
M&L for concealed point wiring with 1.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC Casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS PVC insulated, unsheathed, single core multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly including modular sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out side for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washers complete all as specified and directed for the following points:- Note : Wiring to be done as per approved colour code in IE rule. Rate includes chase cutting for concealed wiring.
(a) One light point / fan/ exhaust fan/ bell point
(b) One 3 pin 5 Amp socket outlet on same board.
(c) One 3 pin 5 Amp socket outlet on independent board.
M&L for concealed point wiring for 3 pin 15 Amp socket outlet on independent board with 2.50 sqmm (nominal area), FRLS PVC insulated, unsheathed, single core multi-stranded copper conductor cable, 1100 volts grade, ISI marked, drawn through and including concealed medium grade PVC conduit not less than 20 mm dia, ISI marked, with all accessories (PVC Casing and caping of size 25 mm, ISI marked with complete accessories to be used wherever wiring to be run on ceilings and concrete surfaces) including one run of 1.5 sqmm FRLS PVC insulated, unsheathed, single core multi stranded copper conductor (Green colour cable) as earth continuity wire connected to common earth dolly including modular sunk sheet steel terminal box made out of 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted with two coats of anti corrosive black bituminous paint over a coat of red oxide primer in and out sides for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washers complete all as specified and directed. Note : Wiring to be done as per approved colour code in IE rule. Rate includes chase cutting for concealed wiring.
S&F of modular cover plate with frame grey colour of 2 modules complete all as specified and directed. Make: L&T Cover plate Cat part No. CB92102FM01/ grid frame cat part no- CB92102GB00 or equivalent in legrand/ scheinder
S&F of modular cover plate with frame grey colour of 3 modules complete all as specified and directed. Make: L&T Cat part No. CB92103FM01/ grid frame Cat Part No. CB92103GB00 or equivalent in Legrand/ Scheinder
S&F of modular cover plate with frame grey colour of 6 modules complete all as specified and directed. Make: L&T Cat part No. CB92106FM01/ grid frame Cat part no- CB92106GB00 or equivalent in legrand/ scheinder
S&F of modular cover plate with frame grey colour of 8 modules complete all as specified and directed. Make: L&T Cat part No. CB92108FM01/ grid frame Cat part no- CB92108GB00 or equivalent in legrand/ scheinder
S&F of modular switch 1 way, single pole, 10 Amp, 240 volts complete all as specified and directed. Make: L&T ENGLAZE CB92601SM10 (Stone Grey colour) or equivalent in Legrand /Sceinder
S&F of modular socket, 6A, 2/3 pin combined 2 module, 240 volts, flush type complete all as specified and directed. Make: L&T ENGLAZE CB92202CM06 (Stone Grey colour) or equivalent in Legrand/ Sceinder
S&F of modular socket outlet multipurpose 2 in 1, 3 pin 5 and 16 Amp, 230 volts complete all as specified and directed. Make: L&T ENGLAZE CB92302CW16 (Stone Grey colour) or equivalent in Legrand / Sceinder
S&F of modular switch, single pole 16 Amp, 230 volts complete all as specified and directed. Make: L&T ENGLAZE CB92302SM16 (Stone Grey colour) or equivalent in Legrand / Sceinder
M&L for sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLS cable of 6.0 Sqmm drawn in and including non metallic rigid PVC conduit of 25 mm dia, ISI marked including one run of PVC insulated unsheathed, multistranded copper conductor FRLS cable of 6.0 Sqmm (Green colour) as earth continuity conductor cable connected to earth dolly complete all as specified and directed. Note: Three runs of cable shall be measured as a single length.
S&F of sheet metal enclosure for MCB, DB, TPN 415 Volts, 200 Amps rated busbar, 4 way, double door, factory made fabricated out of CRCA steel sheet, semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003), IP 43 protection class, with MCB TP as incomer and MCB SP in outgoing complete all as specified and directed.
S&F of sheet metal enclosure for MCB, DB, TPN 415 Volts, 200 Amps rated busbar, 8 way, double door, factory made fabricated out of CRCA steel sheet, semi glossy finished with epoxy polyster based powder paint sprayed (RAL 9003), IP 43 protection class, with MCB TP as incomer and MCB SP in outgoing complete all as specified and directed.
S&F of MCB, TPN, 16 to 32 Amps, 415 Volts, 10 KA breaking capacity, 'C' curve including making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, TPN, 40 to 63 Amps, 415 Volts, 10 KA breaking capacity, 'C' curve including making connection with suitable size copper lugs complete all as specified and directed.
S&F of RCBO, 30mA, 40 Amps, SPN for earth leakage protection including making connection with suitable size copper lugs complete all as specified and directed.
S&F of MCB, SP, 6 to 32 Amps, 240 volts, 10 KA breaking capacity, 'C' curve including connection with suitable size copper lugs complete all as specified and directed.
S&F of LED 24 watt recess mounting light fitting (2 x 2 luminaire) with white powder coated CRCA housing with high power LEDs and aluminium front frame with flat white high power transmission acrylic cover including connecting with PVC insulated multistranded copper flexible cable 0.5 sqmm, two core complete all as specified and directed.
Supply and laying XLPE insulated, PVC sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sq. mm, 4 core, laid in trenches or in floors and testing complete all as specified and directed.
Supply and laying XLPE insulated, PVC sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 16 sq. mm, 4 core, laid in trenches or in floors and testing complete all as specified and directed.
Supply and laying XLPE insulated, PVC sheathed, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sq. mm, 3.5 core, laid in trenches or in floors and testing complete all as specified and directed.
S&F of LED flood light fitting 70 Watt, 230 volts, AC, outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrison resistant including driver and lamps complete including connecting with PVC insulated multistranded copper wire of suitable size complete all as specified and directed.
M&L for earthing with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron earth wire of 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3, SSR including excavation of earth pit in any soil, charcoal dust, common salt 15 mm all around earth plate, PCC M-15 (nominal mix) as in pit and cover, water pipe funnel and GI protection pipe light grade 15mm dia upto panel connecting earth lead to panel complete all as specified and directed. Note : Earth continuity conductor including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate.
Supply, installation, testing and comissioning of 62.5 kVA (50KW) Diesel Generating Set comprising of water cooled engine @ 1500 RPM, 3 Phase, 415 Volts, 50 Hz, 0.8 pf alternator mounted on a base frame along with fuel tank, 12 V battery with leads, first fill of lubricating oil, engine safeties & protections, anti vibration mounting pads, AMF control panel, exhaust system and acoustic enclosure as per the CPCB Norms including one tool kit for repair purpose complete all as specified and directed. Make: Crompton Greaves, Model No. GPWII-PII-62.5 or equivalent in Cummins / Kirloskar.
M&L for earthing complete with galvanised steel plate earth electrode 600 x 600 x 6 mm thick, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to earthing lead of 32 x 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers from earth plate to test point upto 7.5 meter including necessary concrete chamber in cement concrete M-15 (nominal mix), precast RCC cover slab in cement concerete M15 (Normal Mix) of size 40 x 40 x 5 cm duly reinforced with 8 mm dia TMT bars @ 150 mm C/C both ways with one handle for lifting, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI Pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/strate and testing complete all as specified and directed.
S&F of on load changeover switch, 4 pole, 100 Amps, manual changeover in sheet metal enclosure complete all as specified and directed.
City buildcom builders & devlopers
ROYAL CONSTRUCTION
M/s H V Infra Projects
M/S RAKESH TRADERS
POONAM ELECTRIC INDUSTRY
AJIT ENTERPRISES
SHIV SHANKAR MISHRA
M/S AJAY JAIN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .