Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L2₹37.6 L+₹1.9 L (4.91%)Accepted-AOC PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L2 | Accepted-AOC L1 after rejection of non bonafide beads | |
| 2 | L1₹38.0 LRejected-Finance | L1 | Rejected-Finance Rejected due to non bonafide bid | |
| 3 | L3₹41.1 L+₹3.1 L (8.10%)Rejected-Finance HO SR NO 73 TAPKIR MALA CHOWK TAPKIR NAGAR KALEWADI PIMPRI PUNE 411017 | PUNE | MAHARASHTRA | 411017 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹85,900
Closing Date
27 Dec 2021, 6:00 pmClosed
Shri Dhiraj Kumar, IDSE, EE
Garrison Engineer (East), Near COD Estate, Ranjhi, Jabalpur (MP)-482011
As per BOQ
2021_MES_490798_1
8370/E8
Open Tender
Electrical and Maintenance Works
Item Rate
334 days
Garrison Engineer (East) Jabalpur
D b (i) d(v)
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jabalpur
₹85,900
Yes
5 Mar 2022
27 Nov 2021
29 Dec 2021
27 Nov 2021
27 Dec 2021
13 Dec 2021
27 Nov 2021 - 4 Dec 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, regulators, sockets etc and making good disturbed surfaces of walls, floors, as per existing finishes etc complete all as specified.
Taking down carefully unserviceable/partly unserviceable light fittings any type, tube light fittings and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes complete all as specified and directed.
Taking down serviceable/unserviceable electric meter including meter box from existing position carefully for refixing adjacent to main switch board including making good to disturbed surfaces to match with existing surfaces complete all as specified and directed.
Fixing only serviceable electric meter on & including wooden board to the wall and including making good disturbed surfaces to match with the existing surfaces complete all as specified and directed.
M&L for the following point wiring with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS), with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm (FRLS) stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 20 mm dia with MS sheet metal sunken switch/Terminal box 1.2 mm thick and hylam switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified Make of cable - FINOLEX / PLAZA / HAVELLS/POLYCAB & Make of PVC conduit & conduit accessories - PLAZA / FINOLEX/ KALINGA. Note : (i) Making good to match with the adjoining surface shall be included in the quoted rate. (ii) Rate shall be included for Cutting/chases of wall/floor/ceiling complete all as specified and directed.
Same all as per item No 5 above but One light point controlled by one way switch.
Same all as per item No 5 above but One ceiling /exhaust fan point controlled by one switch and regulator.
Same all as per item No 5 above but One 3 pin 5 amp socket out point on the same board with other switches.
Same all as per item No 5 above but One 3 pin 5 amps socket out let point on independent board.
Same all as per item No 5 above but One bell/buzzer point controlled by one bell push.
Same all as per item No 5 above but One light point controlled by two 2-way switches.
Same all as per item No 5 above but for one socket outlet 15 Amp on independent board with 2.5Sqmm (FRLS) cable and 1.5 Sqmm (FRLS) earth wire.
S&F in repair Switch piano flush type single pole one way 5 Amps of ISI mark. Make : Havells/ Anchor/ Plaza.
S&F in repair Switch piano flush button type two ways 5 Amps of ISI mark. Make : Havells/ Anchor/ Plaza.
S&F in repair Socket out let 2 in one, 5/3 pin 5 Amp of ISI Mark. Make : Havells/ Anchor/ Plaza
S&F in repair Switch socket combination 5 Amps 5 pin flush type duly ebbosed ISI mark of make Make : Havells/Anchor/Plaza
S&F in repair Switch socket combination 5 in 1, 5 pin 5/15 Amps flush type universal. Make : Havells/Anchor/Plaza
S&F in repair Ceiling rose, surface bakelite 65x50 mm three terminal complete all as specified Make : Havells/Anchor/Plaza
S&F in repair Call bell AC-230 Volt single pole ding dong Make : Havells/Anchor/Plaza
S &F in repair Bell push, flush type 5 Amps. Make : Havells/Anchor/Plaza
S&F in repairs regulator electronic step type 100/120 watt 5 step complete all as specified and directed Make : Havells/Anchor/Plaza
S&F in repair Lamp holder insulated body with back plate for angle holder all as per specified Make : Havells/Anchor/Plaza
S &F in repairs LED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack, 1x20 Watt, 4 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc.with all accessories internal prewired & including coneecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos complete all as specified and directed. make- Havells Cat Pt No SABERLP36WLED840SPMMAWH or Equivelant of Philips/Bajaj
S &F in repairsLED tube light fittings decorative ultra slim linear fixture with extruded alluminium heat sink envioromentel friendly Energy efficient ready to use pack,1x10 Watt, 2 feet, surface mounting type extruded pvc, snap on installers and domestic electronic Driver, connector block etc.with all accessories internal prewired & includingconeecting up with 2 core flexible cppper conductor cable with sutable size & suitable for and mounting clamps PVC squre box 75x75mm - 2 nos complete all as specified and directed. make- Philips Cat Pt No Philips 20W B22d_3 Crystal white t Bulb or Equivelant of Havells/Bajaj
Supply and fix in repairs LED security light fitting of 30 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of make Havells Cat NoENDURAPEARLSL30WLED757SASYTOPCMP or Bajaj Cat Pt No EXNT P 36L WH CR PC SD.Equivelant of Philips/Bajaj
S&F Surface mounting round, decorative LED down lighter 12 WATT and transulent defuser, prefixed with flat profile and mounting clamps etc., complete all as specified Make Havells Cat Pt No ENDURANEODLR15WLED840MOD or Equivelant of Philips/Bajaj.
S&F in repairs LED light fittings decorative 34/36 Watt surface mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc complete all as specified and directed of Make Havells Cat Pt No BOCR2X2R60WLED857SPCMSGENSSL or Equivelant of Philips/Bajaj
S&F in repairs LED light fittings decorative 36/34 Watt recess mounting type extruded metal/aluminium body, and electronic LED driver, connector block etc. with all accessories internal prewired & including connecting up with 2 core flexible copper conductor cable with suitable size and mounting clamps etc complete all as specified and directed Make Havells Cat Pt No VENUSNEO2X2PLR18-48WLED840MOD or Equivelant of Philips/Bajaj
S&F in repairs GI pipe 'light grade' bracket 25mm dia- 0.9m long & 2 set of clamps made out of 30x5mm MS flat & fixed with anchor bolt suitable for 30W security light fitting complete all as specified and directed
S&F in repairs earth enclosure with 2 pin earth plug socket complete with MCB SP 20/25 Amp, flush mounting type Make -Havells/ LEGRAND/L&T
Taking down ceiling Fan/Exhaust Fan of any size or make complete all as specified and directed.
Hanging only ceiling fan of 1200mm/1400mm/1500mm during wiring Sweep by providing fan hooks in proper manner and making connection with 3 core copper cable including painting all as per specified and directed by Engr-in-Charge.
Fixing only Exhaust fan 230/250/300/380/450 sweep heavy duty including 3 core copper cable & cutting holes if required etc. complete all as specified.
S&F in repairs capacitor 2.5 mfd suitable for ceiling fan/exhaust fan complete all as specified.
Dismantling unserviceable main switch/ kitkat DBs/ MCB including wooden board from existing position and making good disturbed surfaces of wall to match with existing surfaces complete all as specified and directed.
S&F MCB DB made of sheet steel , powder painted with neutral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door, Make -L&T/LEGRAND/SCHNEIDER
S&F MCB DB made of sheet steel, powder painted with bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 4 ways Double door IP-43-IK09 protection grade, Make -L&T/LEGRAND/SCHNEIDER
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail ,230 Volts SPN with 8 ways Double door , IP-43-IK09 protection grade, Make -L&T/LEGRAND/ SCHNEIDER
S&F MCB DB made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, earth bar and Din rail , 230 Volts SPN with 12 ways Double door IP-43-IK09 protection grade, Make -L&T/LEGRAND/SCHNEIDER
NOTE FOR ITEM Nos 28 to 32 -(i).The unit rate includes for cutting the brick walls to accommodate DB to make flush to wall/DB to be fixed on wall including frame made out of MS flat 40x5mm (ii).The unit rate includes for making good the disturbed surfaces including finishes to match with the adjoining surface. (iii) MAKE OF DB & MCB L&T/LEGRAND/ SCHNEIDER
S&F in repair of pvc insulated unsheathed bright annealed bare copper conductor 0.5 sq mm cond. const (NO./Dia mm) (16/0.20) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/Plaza.
S&F in repair of pvc insulated unsheathed bright annealed bare copper conductor 0.75 sq mm cond. const (NO./Dia mm) (24/0.20) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/Plaza.
S&F in repair of pvc insulated unsheathed bright annealed bare copper conductor 1 sq mm cond. const (NO./Dia mm) (32/0.20) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/Plaza
S&F in repair of pvc insulated unsheathed bright annealed bare copper conductor 1.5 sq mm cond. const (NO./Dia mm) (30/0.25) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- polycab/Hevells/Plaza
S&F in repair of pvc insulated unsheathed bright annealed bare copper conductor 2.5 sq mm cond. const (NO./Dia mm) (50/0.25) single core industrial cable & pvc insulated, pvc round sheathed multicore indistrial cable for voltage grade up to 1100 V as per IS 694:1990 as site requirement and as directed by Engr-in-Charge. Make- Polycab/Hevells/Plaza.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm (FRLS), earth continuity conductor of size 2.5 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 4 sqmm and one wire of 2.5 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 6 Sqmm (FRLS), earth continuity conductor of size 4 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 25 mm dia with fittings (ISI marked) fixed on walls/roof/floors all as directed by Engineer in Charge. Notes:- Two wires of 6 sqmm and one wire of 4 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 Single core of size 16 Sqmm (FRLS), earth continuity conductor of 2 Single core 10 Sqmm (FRLS) to be drawn through in and including on metallic PVC conduit medium grade 80 mm dia with fittings (ISI marked) on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) FOUR wires of 16sqmm and TWO wire of 10 sqmm & PVC conduit shall be measured as one unit.
M&L in repairs for Sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 4 Single core of size 10 Sqmm (FRLS), earth continuity conductor of size 2x6 Sqmm (FRLS) to be drawn through in and including non metallic PVC conduit medium grade 50 mm dia with fittings (ISI marked) on walls/roof/floors all as directed by Engineer in Charge.Notes:- (i) Four wires of 10sqmm and two wire of 6 sqmm & PVC conduit shall be measured as one unit. Note : For Item Nos 38 to 41, The makes of wire : PLAZA/ FINOLEX/ PARAGON/ HAVELLS and Makes of conduit : FINOLEX/ SUPREME
S&F in repairs MCB TPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified Make -L&T/LEGRAND/SCHNEIDER.
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 63Amps complete all as specified Make -L&T/LEGRAND/SCHNEIDER.
S&F in repairs MCB SPN 240 Volts, 'C' series, breaking capacity 10 KA of rating 6-32Amps complete all as specified Make -L&T/LEGRAND/SCHNEIDER.
S&F in repairs MCB SP 6-32 Amps 'C' series, breaking capacity 10 KA of rating complete all as specified Make -L&T/LEGRAND/SCHNEIDER.
Earthing complete with galvanized steel earth plate electrode 600mm x600 mm x 6mm buried directly in ground vertically to a depth not less then 2.25 meter below normal ground level with top edge of the plate not less then 1.50 meter below normal ground level connected to galvanized earth wire 4.00mmdia by means of bolts ,nuts ,check nuts and washers complete up to and including test point made out of 40 x 6mm alum flat including earthing pit , charcoal common salt ,Earthing lead 4.00mm dia up to 7.5m, 20mm dia medium grade GI watering pipe ,G.I. protection pipe 15 mm dia up to 7.5m long,,PPC pit in PCC 1:2:4 type B-1 using 20 mm graded stone aggregate ,PCC pit cover including earth work complete all as shown in electrical plate No-3 of SSR-2009 (part-I)
Refixing of servicable MCB any type or size
Taking down partly unservicable tube light fittings any type,and fixtures, etc, and Refixing the same after repair including making good the disturbed surface complete all as specified.
Supply & Fix in repairs latest version, energy saving LED bulb of 7 Watt Make Phillips/Havells/Bajaj.
Supply & Fix in repairs latest version, energy saving LED bulb of 9 Watt make Phillips/Havells/bajaj.
Supply & Fix in repairs latest version, energy saving LED bulb of 12 Watt make Phillips/Havells/Bajaj.
Supply & Fix in repairs latest version, energy saving LED bulb of 15 Watt make Phillips/Havells/Bajaj.
Supply & Fix in repairs LED tube rod retrofit type of 18/20 Watt energy efficient,eco freindly of make Crompton Cat Pt No LT5RT-18-CDLor Havells Cat Pt No LHLDEFXD5L8R020 or Philips Cat Pt No 20W865 T8 IND I-2100 lm, or Bajaj Cat Pt No BLRB 20W CW LED.
Supply & Fix in repairs LED Batten suitable for 18/20 Watt LED tube make of Crompton Cat pt No DMLN1LT8-16 or Havells Cat Pt No LHFXCEP1TNNW020 or Philips Cat Pt No BN021C LED20S PSU CW GR S2, Or Bajaj Cat Pt No BLRB-DB-118 I.
Supply & fix in repairs post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 15/20 w led lamp fitting including lamp all as specified and directed. MAKE: HAVELLS/Philips/Crompton/Bajaj
Supply & Fix in repairs electronic ballast suitable for 1x36 watt tube light fitting make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x28watt make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs copper ballast suitable for 1x36watt make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x18watt make - CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x36watt CFL fitting make - CROMPTON/ BAJAJ /HAVELLS
Supply & Fix in repairs electronic ballast suitable for 1x11watt CFL fitting make - CROMPTON/ BAJAJ /HAVELLS
Supply & Fix in repairs bipin holder suitable for 28/36 watt tube light fitting CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs starter holder suitable for 40/36 watt tube light fitting CROMPTON- / BAJAJ /HAVELLS
Supply & Fix in repairs starter suitable for 40/20 watt tube light fitting CROMPTON- / BAJAJ /HAVELLS
S&F in repairs PVC rectangular block of size 100 x100 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover. Make : ANCHOR/PHILIPS/HAVELLS
S&F in repairs PVC rectangular block of size 175 x100 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover Make :ANCHOR/PHILIPS/HAVELLS
S&F in repairs PVC rectangular block of size 200 x150 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover. Make : ANCHOR/PHILIPS/HAVELLS
S&F in repairs PVC rectangular block of size 250 x200 x50mm for mounting switches, sockets/fan Regulator etc with 3mm thick plastic laminated sheet cover. Make : ANCHOR/PHILIPS/HAVELLS
S&F in repairs PVC rectangular block of size 350 x300 x50mm for mounting switches, sockets/fan Reg, etc with 3mm thick plastic laminated sheet cover. Make : ANCHOR/PHILIPS/HAVELLS
S&F in repairs modular switch piano flush type single pole one way 5 amps. Make : ANCHOR/HAVELLS/LEADER/HPL
S&F in repairs Modular socket out let 2 in one, 5/3 pin 5 Amp. Make : ANCHOR/HAVELLS/LEADER/HPL
S & F in repairs modular switch socket combination 6 pin, 3 module 5/15 Amps flush type universal. Make : ANCHOR/HAVELLS/LEADER
S&F in repairs modular bell push, flush type 6 Amps. Make : ANCHOR/HAVELLS/LEADER
S & F in repairs modular electronic regulator 100/120 watt step type. Make :ANCHOR/HAVELLS/LEADER/HPL
S&F MCCB DB vertical type made of sheet steel , powder painted with nuetral bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 ways Double door. MAKE - L&T/LEGRAND/HAVELLS
Taking down and dismantling of ceiling fan, segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts, (spareparts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and supply and fixing the following items and including necessary transportion to workshop, for 1200/1400/1500mm sweep fan :-
Split pin - 02 Nos
Connection block - 1 No
Insulation rubber bush. - 01 No
Fixing or hanging only ceiling fan after winding fan under item No. 76 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
All as pr item No. 77 here-in-above but exhaust fan of size 225mm to 450mm sweep (except rubber roll, split pin)
Fixing only Exhauest fan after winding fan under item No. 78 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
All as pr item No. 76 here-in-above but air circulater fan of size 600 mm to 750mm sweep (except rubber roll, split pin)
Fixing only air circulater fan after winding fan under item No. 80 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed
All as pr item No. 76 here-in-above but wall fan of size 300 to 400 mm sweep (except rubber roll, split pin)
Fixing only wall fan after winding fan under item No. 82 above and connecting up including provision of 3 core 1.5 Sqmm cable from ceiling rose or connector to fan( max up to 1m length) all as specified and directed.
Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassmbling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed including taking down.(Note- (A) Overhauling of ceiling fans will be carried out at AGE E/M Yard only. (B) The spares required shall be measured and paid separately in the relevant items).
Taking down exhaust fan, of any size and type & cleaning/servicing and overhauling the same, refixing the same on its existing position and connection up complete all as specified and directed.
Supply, fixing and connecting up flexible copper wire twin core of 23/.0078.
Supply only in repair gun metal bush of any size (Make - MSP).
Supply only in repair bearing for ceiling fan (Make - TATA/SKF No.6201/6202).
Supply only in repair bearing for ceiling fan (Make - TATA/SKF No.6203/6204).
Supply only IN REPAIR fan condensor 4 MFD (Make – USHA / UNIVERSAL).
Supply only in repair split pin.
S&F in repair canopy of ceiling fan bottom and upper side of size 1200/1400/1500mm. Make :- USHA/ORIENT/BAJAJ/HAVELLS
Painting of ceiling fan 1200/1400 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified.
Supply & fix in repair fan blade made out of aluminium alloy suitable for wall mounting fan of sizx 300 to 450 mm
Supply & fix in repair GI tubing light grade 40 mm dia use as down rod of ceiling fan ,cut to required length & incl. drilling of hole at both side
Supply & fix in repair GI tubing light grade 20 mm dia use as down rod of ceiling fan ,cut to required length & incl. drilling of hole at both side
Supply & fix in repair GI tubing light grade 15 mm dia use as down rod of ceiling fan ,cut to required length & incl. drilling of hole at both side
S & F in repairs Mild steel work in framed work such as Fan hooks, Clamps, gratings, ladders etc., with ends of bars welded and/ or riveted, or forged and similar work confirming to Fe 410 - O or Fe 310 - O and incl painting to surfaces using two coats of metallic primer and a coat of synthetic enamelled paint of desired colour as directed.
Supply and hanging in replacement 1200mm sweep ceiling fan BEE 5 star rated of colour as approved by GE with double ball bearing, 350-370RPM, 220/240 volts, AC 50 Htz power consumption shall be within the norms under standard test condition along with down rod, canopy and all accessories all as supplied by manufacturer and connecting up with & including of PVC insulated and sheathed three core FRLS copper conductor flexible cable of size 16/0.20mm of sufficient length complete all as specified and directed. Make: Crompton Cat part No. HS Plus- 5 Star or equivalent model of make- Havells or Khaitan or Usha or Bajaj as approved by GE. Note ; old fans shall be deposited to CDA
Supply and fixing in replacement 300mm sweep wall mounted fan of colour as approved by GE with high performance motor, thermal overload protector (TOP) helps in protecting the motor in case of any high voltage fluctuation, aerodynamically designed, operating voltage 220-240 volts, AC 50 Htz complete with and all accessories all as supplied by manufacturer and all necessary nuts, bolts etc of suitable shape and size for fixing to wall as directed & making good the disturbed surfaces as per existing specifications and necessary connections complete all as specified and directed. Make: Havellsor Crompton or Khaitan or Usha or Bajaj as approved by GE. Note ; old fans shall be deposited to CDA
Supply and set in replacement 400mm sweep table fan of colour as approved by GE with high performance motor speed 1360 RPM having 3 Nos motor speed for better air delivery, thermal overload protector (TOP) helps in protecting the motor in case of any high voltage fluctuation, aerodynamically designed & balanced blades, operating voltage 220-240 volts, AC 50 Htz complete with and all accessories all as supplied by manufacturer and necessary connections complete all as specified and directed. Make: Havells model-Swing ZX or equivalent model of make- Crompton or Khaitan or Usha or Bajaj as approved by GE. Note ; old fans shall be deposited to CDA
S&F in repairs garden light 45 Watt warm white LED post top with decorative circular design compliant to dark sky norms, with polycorbonate opal diffuser and IP 65 protection of Bajaj Cat Pt No BGCP 45W LED WW or equivalent of Philips/WIPRO/Crompton
Supply and fix LED building security light fitting of 45 watt, aluminium pressure dia cast IP 66 with high power LED & LED driver of make /Bajaj/Havells/Phillips
S&F in repair of service connection cable using PVC insulated unsheathed, aluminium conductor cable 2 core of size 10 Sq mm, of standred nominclature follow SEI normes all as directed by Engr-in-Charge.
Febricate supply & fix sign board mentioning Office of CDA, Jabalpur of size 2 x 1 meter with inbuilt lighting arragment with standred capital letters all as specified and directed by engr-in-Charge.
S& F MCCB DB VERTCLE TYPE made of sheet steel , powder painted with NUTRAL bus bar 200 A, neutral link, IP-43-IK09 protection grade , 415Volts TPN with 4 way Double door , L&T CAT NO-DBVTL004DD/ LEGRAND CAT NO-607913/ equivalent of ABB
Suply & fix MCCB 63 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98603OOOO /Legrand cat no-420013/schneider cat no-LV510315
Suply & fix MCCB 200 A 35 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92109OON1OG /Legrand cat no-420248/schneider cat no-LV525342
Suply & fix MCCB 250 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92109OOP1OG /Legrand cat no-420249/schneider cat no-LV525343
Supply and install steel, tubular swaged poles complete with cast iron base plate, nuts and taper plug , bolts, nuts and screws as specified type 410-SP- 31 (9.0 m long).
Taking down steel tubular/pcc pole of any size including insulater & cross arm& stay wire & refixing at new location directed by engr-in -charge note - excavation/earth work& pcc measured & paid seperately
Excavation in trenches for laying of cables ,poles and stay in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.50 mtr deep and getting out complete all as specified and directed.
Returning & filling in, including spreading and leveling, watering and well ramming in layers n.exc. 25cm all as specified and directed by Engr-in-Charge.
Removing excavated soil n.exc 50 mtr and depositing where directed at a level n. exe 1.5mtr above the starting point all as specified and directed.
M&L for plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation of poles etc all as specified.
M&L for plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete for stays ,foundation and platform for transformer installation as specified.
M&L for plain cement concrete 1:3:6 type C-2 using 20 mm graded stone aggregate for coapping of pole
S & F 1100 Volts grade line composite phase separators, moulded & bolted type as per IS 1445 - 1997 make max well or Denson suitable for the following :-
Taking down unservisable U/G cable from trenches, wall, floor etc and removing to store for safe custody uopto 25 sqmm Note:- Excavation for taking will not paid for separatly, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
Taking down unservisable U/G cable from trenches, wall, floor etc and removing to store for safe custody above 35 opto 95 sqmm Note:- Excavation for takeing will not paid for separatly, the cable shall be deemed to have taken down from the trenches excaveted for laying of cables.
S& F XLPE insulated armoured and pvc sheated heavy duty electric cable with aluminium conductor 1100 volt grade laid in tranches passing through pipes /ducts including testing complete of following cross sectional area and size note- rate is inclusive of cable gland & cable lugs.
2 core, 4 sqmm cross sectional area
2 core, 6 sqmm cross sectional area
2 core, 10 sqmm cross sectional area
4 core, 16 sqmm cross sectional area
3-1/2 core, 25 sqmm cross section area
3-1/2 core, 35 sqmm cross section area
3 -1/2 core, 50 sqmm cross sectional area
3 -1/2 core, 70 sqmm cross sectional area
3 -1/2 core, 95 sqmm cross sectional area
Steel tubing In repair GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 40 mm diaMake - ITC / JINDAL /ZENITH/TATA/ PRAKASH SURYA
Steel tubing In repair GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 50 mm dia Make - ITC / JINDAL /ZENITH/TATA/ PRAKASH SURYA
Steel tubing In repair GI light grade for cable protection passing under road /floor or for fixing to poles all as specified and as directed of size 80 mm dia Make - ITC / JINDAL /ZENITH/TATA/ PRAKASH SURYA
Supply & lay RCC hume pipe for Road crossing of cables class NP-2 of size 100mm dia complete all as specified and directed
Cutting of hardstanding/ Road for laying of pipe line/cable and making good surfaces after laing of pipe line/ cable up tp 30cm in depth complete all as specified and directed
Material &labour for Boaring of hole under road/hard standing by trenchless technology including HDPE pipe heavy duty of size 100mm dia complete all as specified and directed
M&L for unwashed Sand cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note : maesurement shall be done after puning down of sand complete all as specified and directed.
M&L for brick covering with width equal to length of bricks as mechanical protection to cable with well burnt sub class `B` bricks laid dry and flat complete all as specified and as directed.
Relaying dismentaled Brick covering with width equal to length of bricks as mechanical protection to cable complete all as specified and as directed.
Taking down of faulty LT under ground cable of size upto 3.5x120 sqmm from trenches /pole/wall etc for detecting fault including repair and jointing at site including relaying at the same location complete. Note- Excavation /earth work and cable jointing &jointing kit shall be measured and paid for separately under relevent item of schedule.
Supply & JOINT cable jointing kit straight through joint epoxy type of size 10 sqmm 4core to 16 sqmm 4 core cable size complete.
Supply & JOINT cable jointing kit straight through joint epoxy type of size 25 sqmm 3.5 core to 50 sqmm 3.5 core cable size complete.
Supply & JOINT cable jointing kit straight through joint epoxy type of size 70/ 95 sqmm 3.5 core cable size complete.
Taking down partly unserviceable / unserviceable ,SECURITY/STREET/GATE/FLOOD light fittings from pole/tower for necessary repair and make serviceable as per complaints given by dept through job card / complaint register on day to day basis & all as specified and directed Engr-in-Charge .
Fixing only repaired servicable fitting of any size & any make
Supply & fix Lamp holder porcelain suitable for street light fitting Screw type E-40 base complete all as specified and directed
Supply & fix Lamp holder porcelain suitable for street light fitting Screw type E-27 base complete all as specified and directed
Supply & fix IN REPAIR LED Lamp 40/45 watt type RETROFIT E-22 BASE complete all as specified and directed
Supply & fix IN REPAIR LED Lamp 30/35watt type RETROFIT E-22 BASE complete all as specified and directed
Supply & fix IN REPAIR LED Lamp 20/25 watt type RETROFIT E-22 BASE complete all as specified and directed
Taking Down of street light Bracket including clamps of any type/any size from to pole/wall including necessary nut & bolts as directed complete all as specified and directed.
Fabrication and installation of GI pipe bracket made of medium Grade tubing of size 40 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr includingcomplete all as specified and directed
Fabrication and installation of GI pipe bracket made of medium Grade tubing of size 32 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including complete all as specified and directed
Fabrication ,supply & fix pair of MS flat strip clamps 30 mm x 5 mm with GI bolts nuts and washer for GI bracket of street light includingcomplete all as specified and directed
S&F LED street light lumanaries of size 90 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make-BAJAJ/HAVELLS/PHILIPS
S&F LED street light lumanaries of size 72 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make-BAJAJ/HAVELLS/PHILIPS
S&F LED street light lumanaries of size 60 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make-BAJAJ/HAVELLS/PHILIPS
S&F LED street light lumanaries of size 45 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make-BAJAJ/HAVELLS/PHILIPS
S&F LED street light lumanaries of size 100 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make-BAJAJ/HAVELLS/PHILIPS
S&F LED street light lumanaries of size 25 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection. Make-BAJAJ/HAVELLS/PHILIPS
supply & fix post of lantern fitting made out of black ABS plastic spigot & spun alluminium funnel shaped with clear acraylic cover suitable for 45 w led lamp fitting including lampall as per 112364 of make BAJAJ /wipro ca no-LP02-501-XXX-57-XX/ CROMPTON - LPTO-40/CDL to mount on gate all as per site requirement and spesified and directed by Engr-in-Charge.
Supply & fix In repair PVC insulated 3 core 2.5sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed
Supply & fix In repair PVC insulated 3 core 1.5sqmm multistranded COPPER conductor for connection of Security light from JN BOX to Security light /OH conductor to security light all complete as specified and directed
Supply & fix Astrorex D-22, Multifunctional digital time swithces cat no 004767 of legrand or equivalent of L & T/MDS/GIC
Supply and fix galvanized earth strip 32 mm x 6 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Supply and fix ALLUMINIUM earth strip 25 mm x 4 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Supply and fix COPPER earth strip 20 mm x 3 mm for earthing from earth plate to equipment complete fixed on pocelain insulator every 1 meter interval all as specified and as directed.
Suply & fix MCCB 160 A 35 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92109OOM1OG /Legrand cat no-420247/schneider cat no-LV516343
Suply & fix MCCB 125 A 25 KA,4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- CM92108OOL1OG /Legrand cat no-420056/schneider cat no-LV516312
Suply & fix MCCB 100 A 25 KA, 4 POLE ,thermal magnetic relese, Ics=100% Icu & L&T cat no- SL98605OOOO /Legrand cat no-420055/schneider cat no-LV510317
Taking down MCCB any type & any size
Preparation for surface of existing PCC poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality Exterior grade apex paint all as directed by Engr in charge.
Preparation for surface of existing steel poles including cross arms, nuts, bolts, for painting LT pole 7.5 mtr long above ground level and applying one coat of approved quality of aluminum paint all as directed by Engr in charge.
M&L for run lead joints complete for water mains with spigot & socket pipes and fittings, all as specified and directed. Bore of pipe :-
150 mm dia
100 mm dia
80 mm dia
Supply & fix rubber gasket joint for flange end of following size :
150 mm dia
100 mm dia
80 mm dia
Supply & fix machanical joint ISI marked for spigot end pipe of following size :
Supply and laid spigot/flanged/ socketed CI fittings. Such as bends (any type radius and angle), tapers, tees, collars & tail piece socket/flanged/spigot etc of size 200mm to 300mm dia.
Dismantling/taking out unserviceable sluice valve of size 80mm to 300mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed.
Supply and fix In repair CI sluice KIRLOSKAR MAKE valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 ISI marked complete all as specified and directed of sizes :-
Supply and fix CI sluice valve KIRLOSKAR MAKE both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846/2000 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed of sizes :-
Cutting of road /hard standing for laying /dismentling of pipe line and making good surfaces matching with the existing surface after laying of pipe line.up to 30 cm complete all as specified and directed.
Taking up or down GI Tubing and connections including cleaning for refixing or removal to store of size :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Refixing old GI Tubing and connection in New or old position (walls, Ceiling, Floors etc) of size :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
Laying only old serviceable removed GI Tubing from site and connection in New or old position (in trenches) of sizes complete all as specified and directed :-
Supply and laying in repair GI tubing medium grade with all fittings and fixed complete laid in trenches of size :-
Supply and laying in repair GI tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors of size :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
Removing Unserviceable Gate valve/stop valve of water supply lines, closing the opening with plug or preparing for new as required necessary fitting complete and deposited to E/M store yard of size :-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Supply and fix in repair Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete of size :-
20 mm dia
25 mm dia
40 mm dia
50 mm dia
Cutting existing galvanised iron pipe in position for insertion of new pipe/tees, branches etc.
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
100 mm dia
Taking up Submersible Pump assembly including column pipe approx 50 to70 mtrs using chain pulley block manually and carrying out following phase of work all as directed for 17.5HP/15 HP Pump Set .(i) Transportation of submersible pump -motor assembly for necessary repair. (ii) Carrying out overhauling of motor assembly 3phase ,taking out burnt winding wire,rewinding using super enamelled copper winding wire of appropriate gauge and turn,providing insulation materials and replacement of bearing and assembling with repaired/serviceable pump and testing complete all as directed by Eng-in Charge. (iii) Carrying out dismantling and overhauling of multi stage pump, incl cleaning and derusting of casing, replacement of worm out spare like bearings, impellar bushing, coupling etc & refixing of existing serviceable components after proper cleaning, machining all as required & assembling testing at workshop complete for 17.5/15 HP submersible pump of any make including carrying out painting by two coat of synthetic enamelled paint over a coat of primer,assembling the pump and motor including testing complete.
Adopter
Balancing Ring
Base plate
Bearing Bush
Bearing housing lower
Bearing housing upper
Bearing housing lower open type
Bearing housing upper open type
CI Bearing
Coupling
Coupling key
Drain plug
Flange lower
Flange upper
Flange lower stud
Flange upper stud
Gronmet
Motor Base
MS washer
Ny lock nut
Plug washer
Pressure cup Equeliser
RT disc
Rocker
Rotor clip
Rotor Dowl pin
Rotor nut
Rotor sleev
Stand guard
Stater circlip
Stud O ring
TB axel
T bolt
T bolt housing
Water seal
Water seal O ring
Material & labour for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed by Engr -in - Charge.
Fabricate,supply & fix stainless steel spindle suitable for following dia sluice valve complete with stainless steel nut and threding as per sample & directed by Engr-in- Charge :-
For 150 mm sluice valve
For 100 mm sluice valve
For 80 mm sluice valve
S&F in replacement Digital water leval indicator system 150 mm size digit direct display,operated on 230v Ac, suitable for upto 20 metre height over head Reservior/underground sump of any capacity, preadjustable alarm for upper & lower level, temp range -5 to 50 degree, humidity up to 90% RH, reset push switch for silent the alarm including 4 core 1.5 sqmm copper cable. MAKE: SURYA ELECTRONICS & CONTROLS / RECTRONIC DEVICE & CONTROLS
M&L Fully Automatic Star Delta Motor starter 15 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 11-18 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
M&L Fully Automatic Star Delta Motor starter 12.5 HP in sheet-steel enclosure type MK-1 .feature (Motor Rating AC-3 Duty, 415V, 50Hz, 3-Ph) and Relay Range 9-14 complete all as specified. (Make : L&T cat no SS 96257 or Equivalent OF SIEMENS/schneider)
S & F PVC Insulated unsheathed cable 37/2.04 mm dia single core multistranded bright annealed copper conductor 1100 volts, including taking down conf to IS-694 complete all as specified. Make : Plaza/ Paragon/ Polycab
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 1200 x 1200x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing
Dismantling of existing valve pit and M&L for construction of masonry valve pit (as per drawing No CEJZ/TD/819/91 dated 16/04/91) with the following specification:- Brick work in CM (1:4) with sub class 'B' bricks, 15mm thick plastering in CM (1:4), PCC (1:4:8) type D-2 in foundation, chamber of internal size 900 x 900x1200 mm,150mm thick copping on top in PCC (1:3:6), type C-1, 3mm thick MS sheet for cover, angle iron 40mmx40mmx5mm for frame all around with suitable handle with locking arrangement including two coats of synthetic enamel paint over a coat of red oxide primed on MS work and three coats of white wash and preparation of surfaces complete all as specified and shown on drawing.
M&L draining water from OH reservoirs not exc. 18 Mtr head/staging, and cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 mtr including one coat of synthetic enamel paint on all steel surfaces such as ladder, railing, inlet & over flow CI pipes connected sluice valves of the respective OH tanks/ground level reservoir etc writing letters with white paint (date of cleaning and capcity of tank of 100000 gallon capacity) on black painted surface of tanks all as directed by Engineer-in-Charge.
S&F in repairs for water supply installations LED street light lumanaries of size 90 W pressure die cast aluminium housing with heat resistance toughed glass & IP66 protection Make: Havells Cat Pt No ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or equivelent of Philips or Bajaj.
Manning and Operation of rutine maintenance of water supply installations (Pump House) with deputing one skilled FGM operator of proper trade with ITI qualified having minimum 4 years of experience for round of clock of Two shift of 08 hours each shift (for 16 hrs including holiday and Sunday) for operation of pump sets, chloromes plant/Bleaching Dozer for proper pumping of Lekhanagar including all valves, maintaining all eqpt of pump house, OH tanks, in perfect conditions cleaning of all water supply installation and sorrounding area all specified and directed by Engr-in Charge. The installation comprises the following installations : (a) 04 Nos borewell (15 HP submersible including Starter, panels and connected items). (b) 04 Nos of Sluice Valves for pumping from borewells. (c) 04 Nos of Sluice valves supply from OH tank.
Manning and Operation of rutine electrical complaints by deputing one skilled Electrician and one helper (helper unskilled) operator of proper trade with ITI qualified having minimum 4 years of experience for of 08 hours each shift daily from 8.00 AM to 4 PM including holiday and Sunday) for complaints of Lekhanagar residential colony. All complaints of nature of LT and internal electrification shall attained by the electrician and helper, the safty equipment will be provided by the contractor as per precribed procedure.
Manning and Operation of rutine water supply complaints by deputing one skilled Plumber of proper trade with ITI qualified having minimum 4 years of experience for of 08 hours each shift daily from 8.00 AM to 4 PM including holiday and Sunday) for complaints of Lekhanagar residential colony. All complaints of nature of water supply shall attained by the Plumber, the safty and required tool/equipment will be provided by the contractor as per precribed procedure.
(i) It is the responsibility of AGE/JE to ensure that attendance register is maintained at all the installation duly signed kept on record and payment of trade men for the Nos of days present will only be made, Engineer-in-Charge will be responsible for payment of trade men in his presence. Contractor shall provide proper dress to tradesmen as approved by Eng-in-Charge and during duty hours all tradesmen shall be in proper uniform otherwise necessary recovery @ double the quoted rate for per day shall be made from his dues.
(ii) Leave of deployed person in inescapable cases shall be allowed on prior intimation but Contractor on demand of Engineer-in-Charge, shall arrange alternate arrangment. Payment shall not be allowed for leave period.
(iii In no case wages of deployed persons shall be less than the Minimum wages fixed by Govt Competent Authority. It is mandatory requirement for Contractor that payment of deployed person shall be made through Cheque/RTGS/Acceptable Electronic Mode only. Proof of payment shall be submitted by Contractor to Engineer in Charge monthaly basis or during claiming on account of Advance (RAR)/FB.
(iv) The Employees Provident Funds & Miscellaneous Provisions (EPF & MP) Act, 1952. shall be strictly adhered to by the Contractor. Social Security to workers i.e. EPF, ESIC, Personal Insurance(if applicable) on part of Employer shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
(v) Statuatory levies/GST if applicable on part of contracts shall be paid by Contractor and accordingly, Contractor/Bidder shall include all these factors in his quoted rate.
(vi) Deployed person shall report daily to JE or Engineer-in-Charge or nominated Officers by Accepting Officer for their attendence & obtain instructions. An attendence register shall be maintained by Contractor on site shall be certified by MES rep every day.
(vii) T&P - Working Tools/plants, protective cloths, communication & conveyance arrangments shall be provided by Contractor at his own cost.
(viii) An uniform of blue shirt/jersy duly embossed "MES OUTSOURCING SERVICES" at back and name plate of the person on front left shall be provided by contractor to all workers at his own cost.
(ix) Documentation - Attendance register & wages register,Daily work register as per the format provided by the Deptt shall be prepared & maintained at his own cost.
(x) Contractor shall be made security pass for all operators and maintain proper register duly signed by all concerned.
Schedule of credit amount of Rs. 2,25,387.00 to be deducted during AOC
shri krishna traders
Goodluck Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .