Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.8 LAccepted-AOC NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹37.1 L+₹68,862.50 (1.89%)Rejected-Finance WZ 1000 B NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹37.2 L+₹83,262.50 (2.29%)Rejected-Finance SHOP NO 33 GOPI NATH BAZAR DELHI CANTT 10 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹37.8 L+₹1.4 L (3.86%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹39.3 L+₹2.9 L (7.99%)Rejected-Finance | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
17 Jul 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REPAIR/REWINDING AND MAINTANANCE OF 3311 KV TRF AND REROUTINGINTER CONNECTING OF SUB STN THROUGH HT CABLES AT VARIOUS LOCATOINS WITH CONNECTED ITEMS AT KIRBY GRID IN THE AREA OF AGE (U) ES NO I UNDER GE U ELECT SUPPLY DELHI CANTT10
2021_MES_454184_1
GE ELECT/D-41/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹80,000
Yes
14 Sept 2021
29 Jun 2021
19 Jul 2021
30 Jun 2021
17 Jul 2021
12 Jul 2021
60 days
Amount
Material and Labour for Disconnection Electrically and Mechanically out door Power transformer 33/11 KV up to 16 MVA from HV, LV terminal and control wiring from transformer to control box/Marshaling box complete. Transportation of unserviceable transformer 33/11 KV of up to 16 MVA capacity including radiator by dismantling to workshop for carrying out necessary repairs. Cost of proper washing of radiator checking against any leakage/along and returning back to its original installation position/location is deemed to be included in quoted rates, re-installation, connecting mechanicallay and electrically, testing,commissioning at site and put on load complete all as specified and directied (Men power, T&P rates are included in the quoted rates). NOTES:- (I)Before Lifting of power TRF GE/Engr-in- Charge to be visit/inspect the workshop (ii) All testing equipments in workshop will be calibrated and should be NABL certified only.(NABL certificate will be submitted before lifting of TRF). (iii) Finally,GE /Engg-in-Charge will decide the workshop on the basis of last five years performance of workshop in power TRF repair in MES only and will be binding on contractor to execute the ibid scope of work from the factory decided by Engr-In-Charge.
Material and Labour for Drainining out Power Transformer 33/11 KV of up to 16 MVA Transformer oil including radiator and storing the oil in suitable container (Empty container shall be supplied by the contractor for filling of oil required and shall become the property of contractor after re-use of transformer oil) complete all as specified and directed.
Material and Labour for opening of top cover by unscrewing nut, bolts & washers etc and and taking out core assembly from tank by disconnecting from tap changer HT & LT side bushing stud to outside by dismantling the channel of Power transformer 33/11 KV, up to 16 MVA capacity. After dismentling of Transformer and physical joint inspection of core coil assembly (removing all 3 limbs HV &LV winding from Core Assembly) washing of core assembly by hot oil for removing brunt carbon and copper particals and cleaning of complete top yoke by oil. Re Tanking after re-assembling core,coil , tap leads and tightening of top cover fixing of HV & LV Bushing, OLTC connection, Connection of CT. Filling of oil, conservator tank ready for final testing all as directed in presence of rep of MES. Note :- (i) Rewinding and copper coil cost will be measured in the respective item. (ii) Testing cost measured separately.
Supplying and fixing of complete set of 33/11 KV up to 16 MVA transformer gaskets and insulting material, crep tapes,Craft paper, Nomex Tapes, PCB, insulation glue, cotton tapes, webbing tapes etc complete all as specified and directed.
Material and Labour in repairs for rewinding of HT/LT coils with copper wire DPC/super enameled high quality matching with existing gauge and impedence including requisite insulating paper/material in each layer of winding after taking down old existing winding of HT/LT coils of power transformer 33/11 KV, up to 16 MVA complete. Note : (i) The rate quoted against these items is inclusive necessary provision of all types of insulating materials , heating and varnishing etc.
Material and Labour for drying/ovening of complete Core coil assembly(CCA) in vacume chamber and continous monitering to improve of IR Values after varnishing the coil to eliminate moisture content from Power Transformer 33/11 KV, up to 16 MVA capacity complete .
Material and Labour after drying and ovening and Re-assembling of 33/11 KV,up to 16 MVA Transformer core, tesing of magnetic circuit for IR values, assembly and connection of OLTC of all phases, testing of transformer at low voltage, checking of ratio and polarity test. all as specified and directed. Note: (i) These operations/tests shall be carried out in the factory,results found satisfactory before bringing transformer to the original site for re-installation. (ii) The quoted rates shall be deemed to include complete testing before and after repairs, as per IS-2026, Megger Ratio, LV&HV High Voltage Test, DVDF and vector Group Test and Leagae/Pressure Testing at 0.35 Kg for 24 Hrs to check the healthiness of the transformer, No load test, Full load Test, Impedance test, Voltage/Short Ckt impedance test.
Material & labour for repair /overhauling/Servicing of OLTC ( On load tap changer ) of 33KV/11KV Power transformer of capacities 8/10 MVA at site by carried out following work of make :- Schenider (a) Opening of top plate of OLTC. (b) Draining out of transformers oil from the OLTC. (c) Stoping of leakage of oil from main shaft of OLTC including replacement of oil seal and all gasket of OLTC. (d) Checking /servicing of moving and fixed contact of OLTC and resistence test of contact. (e) Flushing of OLTC assembly with hot new oil and removing of sludge. (f) Filling of new transformer oil in OLTC . (g) Tightening of all tapping leads and connections. (h) Refixing of top plate of OLTC in original position after overhauling. (i) Electrical testing of manual/auto operation of OLTC. Note :- Transformer oil as required shall be measured and paid separately under item No 2 here-in -before as supply only.
M&L in replacement Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized strip 32mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I, connected to earth test point and the equipment on the other nuts and washers of galvanised iron side complete all as specified, including testing and commissioning complete all as directed. Note :- (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in soft/loose soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 type C2 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement 6mm dia both ways as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
Excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and levelling of bottom suface to required level all as specified and directed by Engineer- in- Charge.
Returning filling in,. Including spreading, levelling,. Watering and well ramming soil in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material (ie soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point all as specified and directed by Engineer-in-Charge.
Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc, complete all as specified.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm complete all as specified..
All as per srl item No 14 here-in-before but using old cable cover obtained under srl item No 10 here in before complete all as specified..
S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per srl item No 16 here-in-before but using old bricks obtained under srl item No 10 here in before complete all as specified..
S&F of KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral 63 Amps including embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body complete all as specified and directed.Incluiding MS clamp of size 25x3 mm with suitable size nut,bolts & washer.
Supply drawing, connecting and testing iof 3 core, 1.5 Sqmm PVC insulated and PVC round sheathed copper conductor (flexible ) industurial cable, 1100 Volts conforming to IS 694 in steel tubular poles from KIOSK box to street light fitting including providing suitable copper lugs all as specified and directed by Engr-in-charge.
S&F of HDPE Pipe of size 50 mm dia 3kgf/cm square for cable protections/pole for crossing of culverts/nallah complete all as specified and directed .
Supplying, laying, jointing testing and connecting of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable of size 16 Sqmm 4 core (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed . Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable of following sizes (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches / ducts / encased in GI pipe / fixed to pole, including jointing & testing complete all as specified and directed of following sizes
185 Sqmm 03 Core
240 Sqmm 03 core
S&F cable route indicator made of RCC (Nominal Mix) type B0 1:2:4 (12.5mm graded stone aggregate) with 8mm TMT Bar c/c of size 1m height X 60cm wide X 10cm thick tapered on top, visible above ground, duly painted with synthetic enemel paint of yellow colour base and letters with black paint. The description for writing for HT cable 33 KV as directed by Engr-in-charge complete all as specified and directed. Note : Rate for PCC 1:3:6 for foundation (min size 0.8mx0.3mx0.3m) of aggregate size 20mm for cable route indicator deemed to be included in the item.
M&L for ON load Centrifuging and dehydration including filteration and cleaning of transformer oil by dehydration machine of 33 KV transformer at site and topping up deficient transformer oil including testing of samples before and after dehydration and filteration complete all as specified and directed. Note :- Deficient quantity of Transformer oil required for top up shall be measured and paid separately under item No 25 here-in -after as supply only.
Supply only transformer oil of approved quality as per IS having dielectric strength of 45-60 KV in 2.5mm gap for filling in OLTC & for topping up in transformer as required and directed
NOTE :- (a)The above module consisting of one Load break Switch and 01 VCBs shall be alligned appropriately and must have electrical and mechanical interlocking as per latest electrical safety norms including foundation complete As per OEM
mayur enterprises
M/s JAIMAA ASSOCIATES
M P TYAGI ENGINEERS AND CONTRACTORS
Buddham Builders
MV Engineers And Contractors
Water Power Engg. Enterprises
Rajindera Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .