GE (AF) SIRSA
OFFICE OF GE (AF) SIRSA
REPAIR/MAINTENANCE OF FIRE DETECTION AND FIRE FIGHTING SYSTEM ALONG WITH PERIODIC MAINTENANCE AND REPAIRS OF VARIOUS LIFTS UNDER AF STN SIRSA
2026_MES_792583_1
GE/SRA/T-49/2026-27
Open Tender
Miscellaneous Works
Item Rate
365 days
SIRSA
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) SIRSA
₹40,000
Yes
6 Oct 2026
6 Oct 2026
20 Oct 2026
6 Oct 2026
19 Oct 2026
14 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1SCHEDULE 'A' PART-I : REPAIRS TO FIRE ALARM & FIRE FIGHTING SYSTEM | |||||
| 1.01 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" installed in buildings at WSA Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-
(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 Nos.
(c) Smoke Detectors - 58 Nos. (d) Heat Detectors - 58 No.
(e) Manual Call Point - 14 No. (f) Control Module - 59 No.
(g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No.
(j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible Wire - 1660 RM | 4 | EACH QTR | - | - |
| 1.02 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" installed in ATC Building Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-
(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel Two loop - 05 No.
(c) Smoke Detectors - 58 No. (d) Heat Detectors - 58 No.
(e) Manual Call Point - 14 No. (f) Control Module - 59 No.
(g) Fault/ Short Circuit Isolator - 05 No. (h) Remote Response Indicator - 116 No
(j) PVC Conduit Pipe 25mm - 850 RM (k) Copper Flexible wire - 1660 RM | 4 | EACH QTR | - | - |
| 1.03 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" installed in SRE Building & PAR Building including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults incl replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-
(a) Fire Alarm Control Panel Four loop - 01 No. (b) Fire Alarm Control Panel One/Two loop - 04 No.
(c) Multi sensor detector Smoke & Heat with base - 35 No. (d) Fire alarm sounder/siren electronic type 65 DB to 120 DB - 02 No
(e) Manual Call Point -10 No. (f) Addressable Control Module - 06 No.
(g) Fault/ Short Circuit Isolator - 04 No. (h) Remote Response Indicator - 27 No
(j) PVC Conduit Pipe 25mm - 516 RM (k) Copper conductor cable - 1940 RM
NOTE: Work in all the above buildings shall be measured as a single unit. | 4 | EACH QTR | - | - |
| 1.04 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" installed in AUDITORIUM Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed comprising of the following :-
(a) Fire Alarm Control Panel Four loop (Make:Notifier) - 01 No (b) Network repeater panel - 01 No.
(c) Analogue addressable multi sensor detector - 210 No. (d) Addressable heat detector -04 No
(e) Analogue addressable control module -12 No (f) Fault isolator module - 10 No.
(g) Remote response indicator -04 No (h) Addressable zone interface module -04 No
(j) Hooter / strobe rated 100 db- 12 No . (k) Manual call point- 12
(l) PVC Conduit Pipe 25mm - 380 RM (m) Beam detector - 04 Nos
(m) Copper conductor cable 1.5sqmm- 1050 RM | 4 | EACH QTR | - | - |
| 1.05 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" installed in TECH FLT HANGAR & SQN HANGAR Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-
(a) Fire Alarm Control Panel Four loop (Make: Notifier) - 02 No
(b) Network repeater panel 4 inch 640 character - 04 No.
(c) Analogue addressable multi sensor detector with hard addressing feature - 766 Nos
(d) Addressable fixed temperature 57 degree thermistor type heat detector - 06 No.
(e) Analogue addressable mini monitor module -32 No (f) Fault isolator module - 48 No.
(g) Analogue Addressable with hand addressing - 55 No. (h) Analogue addressable monitor module - 20 No
(j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No.
(l) Dual action addressable manual pull station with address switch - 59 No.
(m) Response indicator for detector - 252 No
(n) Intelligent electronically addressable duct detector (high velocity- 10 Nos
(o) Wall / ceiling mounted type Fire/flame detector - 16 Nos
(p) PVC Conduit Pipe 25mm - 7260 RM
(q) Copper conductor cable 1.5sqmm- 7000 RM
NOTE: Work in both the hangars shall be measured as a single unit. | 4 | EACH QTR | - | - |
| 1.06 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" installed in IGLOO - 05, 06 & 07 Including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified & as directed comprising of the following :-
(a) Fire Alarm Control Panel Four loop (Make: Honeywell) - 02 No
(b) Network repeater panel 4 inch 640 character - 04 No.
(c) Analogue addressable multi sensor detector with hard addressing feature - 398 Nos
(d) Addressable fixed temperature 57 degree thermistor type heat detector - 30 No.
(e) Analogue addressable mini monitor module - 40 No (f) Fault isolator module - 80 No.
(g) Analogue Addressable with hand addressing - 50 No. (h) Analogue addressable monitor module - 20 No
(j) Analogue addressable control relay module - 20 No. (k) Hooter / strobe rated 82 Db- 59 No.
(l) Dual action addressable manual pull station with address switch - 59 No.
(m) Response indicator for detector - 252 No
(n) Intelligent electronically addressable duct detector (high velocity- 10 Nos
(o) Wall / ceiling mounted type Fire/flame detector - 30 Nos
(p) PVC Conduit Pipe 25mm - 7260 RM
(q) Copper conductor cable 1.5sqmm- 10000 RM
NOTE: Work in all 03 Igloos shall be measured as a single unit. | 4 | EACH QTR | - | - |
| 1.07 | M&L for periodic inspection (once in a Qtr) for proper upkeepment and functioning of the "Fire Alarm & Fire Detection System" including checking for all parameters and carrying out petty repairs, identifying and rectifying the faults including replacement of defective parts & accessories and testing the whole system complete all as specified and as directed for the following buildings :-
(i) Base Ops (ii) Signal Unit (iii) CCR (iv) Logistics (v) SMC (vi) Stn HQ
NOTE: Work in all the above buildings shall be measured as a single unit.
GENERAL NOTES TO ITEM NO 1.01 TO 1.07 :-
(i) The work shall be carried out through an experienced and competent agency/technician. Necessary supporting documents shall be submitted before commencement of work for approval of GE.
(ii) In addition to scheduled quarterly inspection, the contractor shall attend all complaints/emergency calls received from the Department and visit the site for diagnosis and rectification of faults/breakdowns. Failure to attend the complaint within 12 hours of receipt, without adequate justification accepted by EIC, shall attract penalty of ₹200/- per day or part thereof for the period of delay. In case replacement of a major/unserviceable component covered under a separate BOQ item is required, the time reasonably required for approval, procurement and replacement shall be considered separately.
(iii) The quoted rate shall include labour, all visits, testing, T&P, transportation, consumables and minor/petty spares/accessories normally required for routine maintenance and minor repairs. Major/unserviceable components specifically covered under separate BOQ items shall be replaced after diagnosis/recommendation and approval of EIC and shall be measured and paid separately. Replaced components shall be handed over to EIC/User as directed.
(iv) All equipment/components of the system shall be inspected, tested and checked for proper functioning. Operational testing shall be carried out in the presence of the User's representative and Engineer-in-Charge.
(v) A test/maintenance report indicating defects noticed, action taken and components replaced shall be submitted after each quarterly inspection and major breakdown, duly signed by the contractor and countersigned by the User's representative/Engineer-in-Charge.
(vi) All T&P, testing instruments, ladders, transportation and safety equipment required for execution of the work shall be arranged by the contractor at his own cost. The contractor shall take all necessary safety precautions and shall be responsible for damage caused due to negligence or improper execution.
(vii) Where OEM-specific equipment, software, testing equipment or procedures are involved, the work shall be carried out by the OEM or its authorised agency/technician, as applicable. The system shall be restored to normal operating condition after completion of the work. | 4 | EACH QTR | - | - |
| 1.08 | S&F in repair including testing and commissioning of addressable type Fire Alarm Control Panel complying with BS EN 54, 2-loop panel, capable of accommodating up to 200 detectors and modules per loop, complete with all accessories, loop cards, power supply card, alarm, acknowledge/reset controls and other necessary components, including taking down and removal of existing panel, complete as specified and directed by the Engineer-in-Charge.
NOTES:-
(I) The new panel shall be of a type compatible with the existing addressable fire alarm field devices and system configuration, wherever such devices are proposed to be retained. Where the existing devices are not compatible with the offered panel, the contractor shall replace the affected devices with compatible devices of the same approved make/system, as required for complete and satisfactory operation, within the scope of the item.
(II) The existing compatible detectors, modules and loop wiring shall be retained and connected to the new panel wherever found serviceable, including necessary programming, addressing, testing and commissioning, without extra payment. Any other external fittings/accessories, if replaced, shal be measured and paid seperately. | 2 | EACH | - | - |
| 1.09 | -ditto- but for 4-Loop Addressable Type Fire Alarm Control Panel | 1 | EACH | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
BOQ_888733.xls
BOQ • 0.41 MB
GENINSTRCTIONT.pdf
Tender Documents • 1.79 MB
Tender.pdf
Tender Documents • 2.08 MB
CREDIT.pdf
Tender Documents • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .