| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.5 LAccepted-AOC 127 3 LOWER BAZAR SHIMLA HP | SHIMLA | SHIMLA | HIMACHAL PRADESH | ₹4.5 L Quoted ₹4.7 L | 1 | Accepted-AOC L1 |
| 2 | 2₹4.7 LRejected-Finance CHITRAKALA ART STUDIO GALLERY DREAMLAND JAKHU ROAD SHIMLA 171001 H P | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171001 | ₹4.7 L | 2 | Rejected-Finance L2 |
| 3 | 3₹4.8 LRejected-Finance 01 SUBHASH NAGAR POKHRAYAN POKHRAYAN KANPUR DEHAT KANPUR DEHAT UTTAR PRADESH 209111 | KANPUR DEHAT | UTTAR PRADESH | 209111 | ₹4.8 L | 3 | Rejected-Finance L3 |
| 4 | Rejected-Technical | - | - | Rejected-Technical As per clause No.3, 5,8 of tender document |
Tender Value
₹4.3 L
EMD Value
₹4,296
Closing Date
7 Feb 2026, 11:00 amClosed
Sr. Executive Engineer
City Electrical Division, HPSEBL, Shimla
Estimate for repair and maintenance of electrical installation and wiring in all blocks of Kumar House Comple and RM of LT Panel. under the jurisdiction of this division
2026_HPSEB_127147_1
Tender No29/2025-26
Open Tender
Electrical Works
30 days
Shimla
As per tender document
2 documents required · 2 mandatory
₹590
₹4,296
20 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
7 Feb 2026
31 Jan 2026
Estimate for repair and maintenance of electrical installation and wiring in all blocks of Kumar House Complex, HPSEBL, Shimla-04.
Estimate for R/M of LT Panel at various locations under the jurisdiction of this division
Note:- Bidder are instructed to fill in the (+/-)% after referring to the irem, rate and quantity in Annexures uploaded online alongwith tender documents
Please Enable Macros to View BoQ information
Chargeable to : 74.703
SCHEDULE OF QUANTITIES AND PRICE
Tender No. HPSEBL/CED/P-Tender No.29 /2025-26 Annexure A
Supplying and Fixing following Piano switch / socket on the existing switch box/cover. as required i)15/16 A socket
Supplying and Fixing following Piano switch / socket on the existing switch box/cover. as required i) 15/16 A socket
Supplying and Fixing following Piano switch / socket on the existing switch box/cover. as required i) Bell Push
Supplying and Fixing modular switch / socket on the existing switch box excluding modular plate and switch box etc. as required i) 15/16 A switch
Supplying and Fixing modular switch / socket on the existing switch box excluding modular plate and switch box etc. as required i) 15/16 A socket
Supplying and Fixing modular switch / socket on the existing switch box excluding modular plate and switch box etc. as required i) Bell Push
Supplying and Fixing call bell/buzzer suitable for single phase 230V, Buzzer
Supplying and Fixing call bell/buzzer suitable for single phase 230V, Ding Dong
Supplying and Fixing MCCB 4 pole 415volt. With thermal magentic Release for overload and short circuit protection breaking Capacity (Ics=100%Icu with positive isolation) with Spreader MCCB 400 Amp, 36kA 4 Pole Released
Supplying and Fixing MCCB 4 pole 415volt. With thermal magentic Release for overload and short circuit protection breaking Capacity (Ics=100%Icu with positive isolation) with Spreader MCCB 630 Amp, 36kA 4 Pole Released
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings. Specification of LED fittings: Diffuser - Polycarbonate diffuser/PMMA, Luminaire efficacy - ≥100 lm/w, Color rendering index - CRI shall be greater than 80 , Working/ operating temperature - 00 to + 450c or better , Color temperature - 60000K + 10%, Drive current (LED) - As per OEM., Surge Protection - 2.5 KV minimum , Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. , Fixture - Should comply with LM 79 test from UL/NABL lab. , LED Type/ Make/ Model - Power CREE/ OSRAM/NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED - 25000 burning hours at 70% lumen maintenance i) LED Batten Light ≥2000Lumens
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings. Specification of LED fittings: Diffuser - Polycarbonate diffuser/PMMA, Luminaire efficacy - ≥100 lm/w, Color rendering index - CRI shall be greater than 80 , Working/ , Color temperature - 60000K + 10%, Drive current (LED) - As per OEM., Surge Protection - 2.5 KV minimum , Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. , Fixture - Should comply with LM 79 test from UL/NABL lab. , LED Type/ Make/ Model - Power CREE/ OSRAM/NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED - 25000 burning hours at 70% lumen maintenance i) LED Batten Light ≥1000Lumens
S/E of LED Downlighter round type surface with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. Diffuser - Polycarbonate diffuser/PMMA, Luminaire efficacy - ≥100 lm/w, Color rendering index - CRI shall be greater than 80 , Working/ operating temperature - 00 to + 450c or better , Color temperature - 60000K + 10%, Drive current (LED) - As per OEM., THD - Less than 10%, Surge Protection - 2.5 KV minimum Efficiency Driver - ≥85%, Protection - Shall have under voltage and over voltage protection. Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. Fixture - Should comply with LM 79 test from UL/NABL lab. LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED - 50000 burning hours at 70% lumen maintenance LED Down Light ≥2400Lumens.
S/E of LED Downlighter round type surface with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. Diffuser - Polycarbonate diffuser/PMMA, Luminaire efficacy - ≥100 lm/w, Color rendering index - CRI shall be greater than 80 , Working/ operating temperature - 00 to + 450c or better , Color temperature - 60000K + 10%, Drive current (LED) - As per OEM., THD - Less than 10%, Surge Protection - 2.5 KV minimum Efficiency Driver - ≥85%, Protection - Shall have under voltage and over voltage protection. Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. Fixture - Should comply with LM 79 test from UL/NABL lab. LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED - 50000 burning hours at 70% lumen maintenance LED Down Light ≥1500Lumens.
S/E of LED Downlighter round type surface with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings. Diffuser - Polycarbonate diffuser/PMMA, Luminaire efficacy - ≥100 lm/w, Color rendering index - CRI shall be greater than 80 , Working/ operating temperature - 00 to + 450c or better , Color temperature - 60000K + 10%, Drive current (LED) - As per OEM., THD - Less than 10%, Surge Protection - 2.5 KV minimum Efficiency Driver - ≥85%, Protection - Shall have under voltage and over voltage protection. Guarantee of LED fittings including LED driver - 2 years against manufacturing defect. Fixture - Should comply with LM 79 test from UL/NABL lab. LED Type/ Make/ Model - Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer. Life of LED - 50000 burning hours at 70% lumen maintenance LED Down Light ≥1200Lumens.
ROAD LIGHTING FIXTURE 120WATT Housing & Finish- Pressure die-cast aluminium alloy for housing (heat sink) for effective thermal management, sturdiness, excellent corrosion resistant, separate optical and control gear compartment & top opening for easy maintenance. Polyster powder coated grey after phosphochromate treatment. Operating temperature: -10° C to + 50° C, Operating voltage range: 140 V - 270 V, Average life L70B50: 50000 hours, Light source: High efficiency long life LED modules with SMD LED package mounted on MCPCB. Lumen efficacy of LED >140 lm/W with PC lens to ensure better uniformity of light distribution. Electronic Driver: Powered by Built-in, Potted electronic LED driver (SMPS based constant current supply) with lower THD, Output Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection upto 10 kV with external SPD & other safety tests as per IS 15885 Part-2/ Sec13. Mounting & Maintenance : Suitable for pole mounting with bracket arm OD 58 mm (max). Recommended mounting height with suitable inground reinforcement is 9 -10 m. Make:Havels/ Philips/Crompton/Panasonic
Supplying and Fixing 32A rating, 240, 10ka 'C' curves miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections, testing and commissipning etc. as required Single Pole 32 A
Supplying and Fixing Flexible wire 0.5sq mm
Grand Total
Chargeable to : 74.510
SCHEDULE OF QUANTITIES AND PRICE
Tender No. HPSEBL/CED/P-Tender No.29 /2025-26 Annexure B
Repair of LT distribution Panel by dismantling of burnt 630A MCCB and providing, fixing, testing & commissioning of MCCB 630 Amp. Capacity, Thermal Magnetic Release (Range 320-400 Amp.) Breaking Capacity 36kA, 4 Pole Fixed Type make Schneider/Siemens/Havels//ABB/ Legrand along with spreader links complete in all respect in (E) Section Ghora Chowki and in (E) Section Ridge
Grand Total
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
BOQ_187682.xls
BOQ • 0.25 MB
TENDERDOCUMENT30.pdf
Tender Documents • 0.21 MB
ES29.xls
Additional Documents • 0.05 MB
Download all tender documents and submit your bid