Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance 98 PANIYARE PURWA MAKRAND NAGAR SARAIMEERA KANNAUJ KANNAUJ UTTAR PRADESH 209726 | KANNAUJ | UTTAR PRADESH | 209726 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹10,000
Closing Date
22 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE ETC Shahjahanpur
Electy. Trans. Circle Shahjahapur
Work
2023_UPTCL_868557_1
27 ETC(S)/2023-24
Open Tender
Electrical Works
Fixed-rate
90 days
Hardoi
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹10,000
4 Jan 2024
7 Dec 2023
23 Dec 2023
7 Dec 2023
22 Dec 2023
7 Dec 2023
7 Dec 2023 - 22 Dec 2023
Amount
Safe carriage of Oil storage tank of 50KL including loading, unloading & carriage upto the site of approx 30KM from 220KV Substation Mallawan to 132KV Substation Sandila
Complete safe dismantling of the accessories of 132/33KV 20MVA Transformer (BHEL make)including opening of jumpers,removal of earthing,removal of bushings,conservator tank,pipe lines, cooling fans,marshelling box, radiators including oil draining from radiator, opening of control cable and fixing of blanking plates on the radiators,pipelines,conservator tank, turret etc with proper stacking.Nut & Bolts to be provided by contractor.
Dismantling of following equipments with due opening of jumpers ,earthing, Cable connections ,Nut bolts and shifting to store from site:
120KV LAs with Structure
145KV 0.2Class CTs
36KV 0.2Class CTs
Shifting of oil filled main tank of 132/33KV 20MVA (BHEL make) Transformer from the plinth to storage place upto 20meter (approx) distance including turning of tank if required with all T&P and other associated work to complete the job.
Additional shifting of 132/33KV 20MVA Transformer main tank upto 35 meter distance (1job for every 5 meter)
Shifting of oil filled main tank of 132/33KV 40MVA Transformer from storage place to plinth upto 20meter (approx) distance including turning of tank if required with all T&P and other associated work to complete the job.
Additional shifting of 132/33Kv 40MVA Transformer main tank upto 25 meter distance (1job for every 5 meter)
Complete drain out of Transformer oil from 40MVA T/F into empty oil drum/storage tank
Replacement of all gaskets including the top of 40MVA Transformer by providing & fixing new gaskets as per existing size made of rubberised cork sheet made of kotika/turboze/nucork brand grade 07.
Replacement of all ring shaped washer placed on air release valve of all radiators by providing new gasket as per existing size made of special plastic teflon washer of suitable size 28 to 30mm
Overhauling of diverter switch & buchholz relay of 40MVA Transformer after removing dirty transformer oil from its chamber.Filling of frsh centrifused transformer oil & checking of proper operation of buchholz relay.
Cleaning the core & winding by fresh transformer oil and removing the sludge from bottom of 40 MVA Transformer
Painting of Transformer after removal of rust/ dust then painting them with one coat of Red oxide then two coat with smooth gray of ISI mark paint.
Complete erection of 132/33KV 40MVA Transformer including erection of radiator, conservator tank,all bushings,turrets, buccholz relay, connecting pipes, cooling fans,motor drive mechanism of tap changer and attending the oil leakage if any and all other associated works for satisfactory completeion of work. All T&P to be provided by the contractor at his own cost.
Creating vaccum inside the main tank for period of 12 hrs and top of oil to core, winding tank, conservator & radiator of 40MVA Transformer
Centrifuging of oil in main transformer tank un-interrupted till the desired BDV valueof the oil is achieved including recording of all the parameters hourly such as temperature, BDV, PPM vaccum etc.Centrifuging Machine, operator, lubricant and all T&P to be provided by contractor.
Erection of following equipments as per instruction manual and technical specification including shifting from store to site alongwith necessary cable connections and jumpering:-
120KV LAs with structure
145KV 0.2sClass CTs
36KV 0.2sClass CTs
Earthing of Main Tank, marshelling box, Drive mechanism, Transformer neutral etc of 40MVA Transformer, 3No of 145Kv CT, 3No of 36KV CTs along with their JB and 3no of 120KV LAs with 75x10mm and 50x6mm MS Flat strips which includes providing, cutting,welding, strengthening and bending of MS flat and shifting of all other associated material from store to work site:-
Painting of MS Earthing strip (R. Mtr.) by rubbing with sand paper & wire brush then painting with 1coat of Red Oxide primer & 2 coats of 1st quality synthetic enamel paint of Asian/Berger/Nerolac make in Bus green color including vertical support.
75x10mm size MS earthing strip
50x6 mm size MS earthing strip
Providing of bore well type pipe earthing 5 meter below the water level but minimum depth of pipe earthing should be 40 meter at T/F neutral, LA & CT's by using Ist Class GI pipe (ISI mark) of size 40mm dia. All the material will be provided by the contractor.
Making of triangular bridge for above pipe earhting by using 32mm dia round bar & GI strip of size 50x6 mm. All the material will be provided by the contractor.
Jumpering of HV Bushings of Transformer with ACSR panther conductor
Jumpering of LV Bushings of Transformer with twin ACSR panther conductor
Erection & installation of RTCC panel of 40MVA T/F along with shifting from storage place to Control room including termination & connection of control cables at RTCC panel side & transformer side as per technical specification.
Laying of following size control cable from RTCC panel at control room to equipments like Fans, OTI, WTI, marshelling Box etc of Transformer at site including making necessary holes in gland plates whereever required with providing 7 fixing of cable glands of appropriate size, PVC ferrules as per drawing and all associated works to complete the work satisfactorily:-
2CX2.5sqmm
4CX2.5sqmm
6CX2.5sqmm
Cable connection (laying of cable if required) as per schedule of 40MVA Transformer ,Cooling fans,Marshelling box , all mechanical relays using existing cable for both functioning in Auto & manual mode. MCBs, O/L relay, contactors, Timer etc to be provided by contactor if required
Pre commissioning test of 40 MVA 132/33Kv Transformer in which following tests are to be conducted:- i)SFRA ii)Tan Delta Capacitance measurement of windings iii)Tan Delta capacitance measurement of bushings iv)Winding resistance measurement v)Voltage Ratio Test vi)Magnetizing Current test vii)Magnetic Balance Test viii)Insulation resistance Test & PI Test ix)Short Circuit Test
Proper packing of HV bushings of dismantled 20 MVA 132/33Kv Transformer (BHEL)Make including proper wrapping with polythene sheets in the wooden crates (to be provided by contractor) and stacking them in stores
Supply of 132KV bushing palm clamp made of brass length 4inch hollow type with slots of dia as per dimension of bushing rod with GI nuts and bolt and spring/plain washer. As per sample.
Supply of 33KV bushing palm clamp made of brass length 4inch hollow type with slots of dia as per dimension of bushing rod with GI nuts and bolt and spring/plain washer. As per sample.
Supply of 132KV bushing clamp made of LM6 aluminium alloy for panther conductor with GI nuts and bolt and spring/plain washer. As per sample.
Supply of 33KV bushing clamp made of LM6 aluminium alloy for twin panther conductor with GI nuts and bolt and spring/plain washer. As per sample.
Supply of BREATHER size 6 kg size for 40MVA T/F As per sample.
Supply of BREATHER size 1kg size for 40MVA T/F As per sample.
Supply of sand buckets as per technical specification
Supply & installation of 150Watt LED flood light fitting with lamp of latyest design complete with De-fuser suitable for outdoor installation with IP65 enclosure( power supply single phase 230volt 50Hz AC )
Providing and Fixing of Updated Single Line Diagram in PVC sheet of size 6x6 feet of complete 132/33KV switchyard of 132KV Substation Sandila as per instruction by concerning JE/SDO.
Obtaining No Objection Certificate from office of Electrical safety Directorate, Lucknow for first time energisation of 40 MVA 132/33KV Transformer (including payment of fee as per challan.)
rbs engineering
TAJ ENTERPRISES
Awadh Construction Company
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .