Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.2 LAccepted-AOC | L1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | L2₹30.4 L+₹7.4 L (32.1%)Rejected-Finance BOOTH NO 15 SHOPPING COMPLEX URBAN ESTATE PHASE II JALANDHAR CITY PIN 144022 | JALANDHAR | PUNJAB | 144022 | L2 | Rejected-Finance Other than the lowest bid | |
| 3 | L3₹32.3 L+₹9.3 L (40.6%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L3 | Rejected-Finance Other than the lowest bid | |
| 4 | D M T UTILITY SERVICES L4₹34.0 L+₹11.0 L (47.8%)Rejected-Finance | L4 | Rejected-Finance Other than the lowest bid |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Nov 2022, 6:00 pmClosed
Garrison Engineer (West) Jalandhar Cantt
Kabir Road Jalandhar Cantt
DAY TO DAY MAINT OF INTERNAL ELECTRIFICATION JCO OR MD ACCN AT KK VIHAR BHAGAT ROAD FAFA RT LINE AND VAJRA COMPLEX UNDER GE (W) JRC
2022_MES_552954_2
GE/JAL(W)-54/2022-23
Open Tender
Civil Works
Item Rate
270 days
Jalandhar Cantt
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer (West)
₹90,000
Yes
16 Jan 2023
1 Nov 2022
23 Nov 2022
1 Nov 2022
21 Nov 2022
8 Nov 2022
Amount
Attending of complaints from 0900 hrs to 1700 hrs by deploying electrician along with helpers for checking of existing electrical items including carrying out repairs such as tightening of loose electric connections, nuts, bolts, screws, repair/ replacement of switches, sockets, switch boards ceiling fans/exhaust fan, DB wiring etc as required to make the item functional and to ensure contiunous electric supply complete as specified and directed by Engr-in-Charge. Note: (a) Replacement of electric fitting shall be mesured and paid for seperately under respective items (b) Rate quoted deemed to be inclusive of T&P etc. (c) The saftey and insurance of persons/helper engaged in Execution shall be responsibility of contractor. (d) As the Nos of complaints shall be on required basis the financial effect to this is deemed to be included in the rate quoted. (e) Penalty rs 50/p per complaint per day be charged if complaint not rectified within 24 hours
Taking down carefully aluminium / copper point wiring (light / fan / socket or power) & sunken boxes while not disturbing existing conduit complete including fitting such as switches, ceiling roses, socket, light fittings, regulators etc complete and making good disturbed surfaces of walls and floors .
Taking down sub main wiring of two single core PVC cable PVC insulated 4 / 6 sqmm including conduit or wooden batten and remove from the site of work and making good the disturbed surfaces of wall or floor etc. as directed by Engineer-in-Charge.
Taking down main switch / DB and making good disturbed surface of wall as directed by Engineer-In-Charge.
M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into existing PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet all as specified. (a) One light / fan / call bell point controlled by one, one way switch.
(b) Do all as per Ser item No -5 above but for 5 amps socket on independent board
(c) Do all as per Ser item No- 5 above but for 5 amps socket on same board
M&L for point wiring with PVC insulated, unsheathed cable single core multistranded copper conductor FRLS cable 1.5 sqmm size, 1100V grade, drawn into and including PVC rigid concealed conduit medium grade (ISI marked) including PVC unsheathed cable single core copper FRLS conductor 1.5 Sqmm as continuous earth wire and including pressed MS sheet sunken box 1.6 mm thick with 3 mm thick laminated bakelite sheet one light / fan / call bell point controlled by one, one way switch.all as specified.
Do all as per ser item No- 5 above but with 2.5 sq mm cable for 15 amps switch socket combination outlet on independent board complete all as specified and directed.
Supply & fixing switch piano flush type single pole one way 5 Amps all as specified.
All as item 7 here-in-before but single pole 5 Amps two way all as specified.
Supply & fixing switch piano flush type single pole 15 Amps.
Supply & fixing socket outlet 5 Amp flush button type all as specified.
All as per item 7 here-in-before but 6 pin 5/15 Amps multi type.
Supply & fixing ceiling roses surfaces bakelite two three terminals 65 x 50 mm all as specified.
Supply & fixing lamp holder PVC, insulated body with back plate suitable for batten fittings including LED lamp 9W all as specified.
Supply & fixing bell electric (dingdong) 230 volt, SP
Supply & fixing switch piano single pole bell push all as specified.
Supply and fix ceiling fan regulator Electronic rotary Step type single phase A/C 230 volts all complete as specified and directed.
Supply & Fixing MCB DP 240 volts 40 Amps to 63 amps in the existing DBs.
Supply & Fixing MCB single pole , 240 volts, 6 to 32 Amps in the existing DBs.
Supply & Fixing MCB, 240 volts, 63 Amps SPN .
Supply & fixing inrepair MCB DB SPN suitable for MCBs 8 way all as specified and directed by Engr-in-Charge.
Supply & fixing inrepair decorative wall light fixture made up of polycarbonate, with LED Bulb of suitable base of 9W .
Supply & fixing MCCB 4 pole of capacity 100 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment all as specified and directed by Engineer -in-Charge Make: SCHNIDER/SEIMEN/LEGRAND
Supply & fixing MCCB 4 pole of capacity 63 Amps with breaking capacity 16 Kilo Amps including all electrical connections and fixing arrangment all as specified and directed by Engineer -in-Charge Make: SCHNIDER/SEIMEN/LEGRAND
S &F in repair LED secuirty light fitting 25 Watt with Electronic driver IP 66 Powder coated pressure die cst aluminum body with heat resistance toughened glass and accessories like GI Bracket , clmaps etc
S & F 6.5 W LED Bulk Head fitting and connecting electricity using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed
S&F in replacement LED lights fitting 1 x 20W, 220V, with driver, including LED tubelight connecting up with electricity to celling rose using PVC insulated and overall sheathed flexible copper conductor of size 0.75mm 3 core complete all as specified and directed.
Supply & fixing LED tube rod 20 W in existing tube light fittings including making necessary conections as required for LED tube all as directed .
Supply & fixing distribution board VTPN, double door, 08 way 440 Volts with sheet metal enclosure 200 Amps busbar with MCCB 63 Amps, 4 pole.
Supply & fixing MCB TPN , 4 pole100 Amps415 volts. Make: SCHNIDER/SEIMEN/LEGRAND
M&L for concealed conduit sub main wiring of 2 run of single core multi stranded PVC insulated FRLS and unsheathed copper conductor as per IS-694 red and black colour of size 6 sqmm 1100 volts grade with 6.0 sqmm multi strand copper conductor PVC insulated and unsheathed FRLS cable in green colour earth continuity wire connected to common earth dolly in PVC pipe including cutting chasing complete with all accessories as specified and directed.
Material & labour for submain wiring with two RUNS of single core 4 sqmm for main wire and one run of single core 4 sqmm as earth wire of stranded copper conductor PVC insulated unsheathed FRLS cables drawn through and including concealed conduits in wall and necessary cutting and chassing for rigid PVC conduit ISI marked of required size dia and all accessories complete all as specified & directed.
Supply & fix bakelite Hylem sheet 3mm thick of size 10"x12" superior quality, including cutting of sheet to fix switch socket & regulator, including unscrewing the existing switch, socket, regulator and refixing the same on new sheet with new machine screw complete all as specified and directed.
All as per item no 35 but of size 8"x10" complete all as specified and directed.
All as per item no 35 but size 8"x5" complete all as specified and directed.
All as per item no 35 but size 4"x4" complete all as specified and directed.
M&L for fixing MS sunken box of 1.6 mm thick of box sizes of size 10" x 12" and making good to wall. (a) boxes of size 10" x 12"
(b) boxes of size 8" x 10"
(c) boxes of size 8" x 5"
(d) boxes of size 4" x 4"
S&F mettalic louvers made of 1.2 mm thick MS sheet including nuts, washers and screws etc required for fixing of louvers, suitable for 250/300mm exhaust fan fixed at ground floor/ first floor/ second floor of buildings and making good to wall. Note : The cost is inclusive of necessary T & P required for fixing the louvers
M&L for earthing complete with GI steel earth plate electrod 60x60cmx6.00mm thick buried directly in ground /earth pit not less than 2.25m deep below the ground level with top edge of the plate not less than 1.5 m below the normal ground level connected to test point by using GI wire of dia 4 mm as earthing lead soldering/revated to earth plate at one end and connected DB by means of nut, bolts etc complete with PCC pit (1:3:6) type GI cover with handle funnel with watering pipe wire mess GI protection pipe for earthing lead all complete as specified and as per electric plate No.5 of SSR Part I
B.P CONSTRUCTION CO
CHOUDHARY AND SONS
D M T UTILITY SERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .