| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹1Accepted-AOC | 1 | Accepted-AOC OK | |
| 2 | 2₹5.5 L+₹79,362.27 (16.8%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹5.8 L+₹1.1 L (23.8%)Rejected-Finance | 3 | Rejected-Finance L3 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
7 Feb 2022, 3:00 pmClosed
Executive Engineer
M.C. KARNAL
Installation of 1 no High Mast Light and 3 mini mast light in community center, Sec-7, Karnal. (District plan scheme 2021-22)
2022_HRY_206316_1
31.01.22/1/light
Open Tender
Civil Works
Works
30 days
Karnal
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹10,000
Yes
31 May 2022
2 Feb 2022
7 Feb 2022
2 Feb 2022
7 Feb 2022
2 Feb 2022
Amount
Supply and Erection of T- channel bracket made of curved brackets casted monolithically with pole as per design and drawing with same material as that of pole including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-incharge. Bracket duly erected/mounted on existing 9 mtr./10 mtr. High Octagonal pole and should be suitable for LED light fitting dia including the cost of labour and petty material etc.
Supply and erection of under ground Aluminium armoured cable XLPE insulated cable ,loose in existing pipe or trenches complete with necessary connections. Cable as per list approved by DULB/PWD Department etc. 16 Sq. mm 4 Core Cable .
200 watt Flood light :- Supply and Erection of LED based flood light and it must be posses the following minimum specification :- 1.The 05 years warranty will be given by the Manufacturer/Brand area Manager in written. Only then, LED light will be acceptable. 2. LED lights fittings as per list approved by DULB/PWD Department etc.
NS "100 watt Flood light :- Supply & Erection of LED based flood light and it must be posses the following minimum specification :- 1.The 05 years warranty will be given by the Manufacturer/Brand area Manager in written. Only then, LED light will be acceptable. 2. LED lights fittings as per list approved by DULB/PWD Department etc. " 1 Input voltage:- 90-270 V, AC standred with cut off at 300v with automatic on provision. for protection from surge high voltage the provision of auto shut down should be provided. 2 Input Frequency:- Input Frequency =50 Hz + 3% 3 Power factor :- (>0.95) 4 Working Humidity:-10% to 90% RH 5 Working temperature:- -10°C to (+) 50°C) 6 Luminary efficiency:- ≥100 lumen/watt as per LM79 data from certified third party testing facility like NABL approved lab/UL Lab. 7 Optics-Lens Material/Make of lens:- High impact polycarbonate (PMMA)/Cathode, Ledlink, Ledil. 8 Luminary Housing:- power pressure die cast aluminium housing with ADC 12 Or LM6 alloy and toughened glass cover. 9 Screws, Fasteners & Clamping material:- Stainless steel Grade – 304. 10 Surge / Spike Protection:- 4 KV (internal) and 10 KV using external certified surge protector. 11 Make of LED:- Lumileds/Cree/Osram /Nichea /Samsung/Seoul or any other equivalent. 12 Color Temperature:- 5500-6500K 13 Color rendering index:- ≥ 70 14 Life expectancy of the project (LEDs):- Minimum 50000 hrs. with minimum 70% lumen output L70 data to be produced for LEDs and LM79 for Luminaries. 15 LED Printed Circuit Board:- Metal Core Printed Circuit Board. Thermal Conductivity ≥ 2W/MK 16 Class of Power Supply:- Class II, LVLE input output isolations (Max 100 VA output) 17 THD:- ≤ 10% 18 Uplight:- Zero Uplight as per LM79 report from NABL/Lighting Facts/accredited third party testing facility. 19 Photomtry :- LM79 Report from NABL/Lighting Facts accredited lab for all variants. 20 Lumen depreciation (L-70) :- ≥ 50,000 hours (as per TM21 using L80 data & INSITU data by LED manufacture LM 80 report). 21 Ingress Protection:- IP66 as per IEC 60598/IEC 60529 from NABL accredited lab for all LED. 22 Conducted Emission and Radiation:- Emission test report from NABL accredited lab conforming limits complying with IEC 61000. 23 Driver Test:- As per BIS 24 Wattage Variation:- ±10% 25 Wattage of LED:- 1-3 watt 26 Pole entry dia :- Should be suitable for mounting of 30 to 56mm outer diameter poles with locking bolts / should provide with complete bracket with locking bolt. 27 LED drive current:- <1000mA 28 Beam angle:- 80° / 135° with lens 29 Safety Test:- As per IEC 61347 – 2 - 13 30 LED lights fittings as perlist approved by DULB/PWD Department 31 LED light fitting will provide a on site Guarantee/Warranty certificate applicable for minimum five(5) years from the date of commissioning of LED lights fitting from company in written.
Supply, erection and commissioning of Timelite 63/65 A. 3 pole / 230V Astronomical time switch Indo Asian / Standard / L&T / Havells make automatic Timer ON/OFF the street light, pillars, wall, MS pedestal where ON/OFF point is available cabinet is fabricated from 22 gauge MS sheet painted, wiring, connection ON/OFF from the bottom of the cabinet the lite DB IP 54 protection complete with Digital timer, 32A. TPN MCB (Indo-Asian), fuse unit, indication lamp suitable for switch from rectifier system, switching system Bakelite connector 32A. Digital timer, auto / manual system, time setter, fiber sheet rubber & plastic components, wiring & component fitting, chemical (Epoxy) including the cost of labour and petty material etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of the work.
Bidder Name
Amount
Royal Traders(GSTN-06BDLPK6716N1Z1)
Mohit Malhotra Contractor(GSTN-NA)
Choudhary Electricals(GSTN-NA)
Mohit Malhotra Contractor
Choudhary Electricals
Mohit Malhotra Contractor
Choudhary Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .