| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.6 LAccepted-AOC | L1 | Accepted-AOC FIRST LOWEST BIDDER | |
| 2 | L2₹35.0 L+₹4,412 (0.13%)Rejected-AOC | L2 | Rejected-AOC SECOND LOWEST BIDDER | |
| 3 | L3₹35.6 L+₹61,400 (1.75%)Rejected-AOC | L3 | Rejected-AOC THIRD LOWEST BIDDER | |
| 4 | L4₹35.6 L+₹63,245 (1.81%)Rejected-AOC | L4 | Rejected-AOC FOURTH LOWEST BIDDER | |
| 5 | L5₹36.1 L+₹1.1 L (3.17%)Rejected-AOC NEAR PUNJAB NATIONAL BANK KANDOLI NAGROTA JAMMU | JAMMU | JAMMU AND KASHMIR | 180001 | L5 | Rejected-AOC FIFTH LOWEST BIDDER |
Tender Value
₹46.4 L
EMD Value
₹92,800
Closing Date
15 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Nagrota
Garrison Engineer Nagrota Pin 901208 c/o 56 APO
SPECIAL REPAIR BUILDING NO NP 01 AND PS 502 AT NAGROTA MILITARY STATION
2023_MES_598033_1
GEN-8545/2023-24
Open Tender
Civil Works
Item Rate
180 days
Nagrota
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Nagrota
₹92,800
Yes
6 Jul 2023
24 May 2023
22 Jun 2023
24 May 2023
15 Jun 2023
10 Jun 2023
Amount
SCHEDULE ‘A’ PART-I Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings complete all as specified & directed.
M & L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
M & L for Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed
Dismantling timber scantlings of fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section framed Work )complete all as specified and as directed
M&L Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, gusset plates, or flat sections) including distance pieces, cleats etcFe 410 -W (GdeE- 250) qualityA complete all as specified and as directed
M&L Mild steel screw bolt (machine made) dia 16 to 20 mm with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 22.5cm and n exc 30cm long complete all as specified and as directed
Demolition of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr complete all as specified and as directed
M&L Brick work with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and as directed
All as per srl item No 08 above but except bricks.
Dismantling wall & ceiling boards(fibre pulp insulation etc) or insulation boards/ slabs/blankets, any thickness including cover fillets complete all as specified and as directed.
S&F GI snap grid (powder coated) frame work of grid size 605x605mm including hangers 6mm dia GI (upto 1200mm long) for false ceiling including notching and preparing holes, including aluminium cleat/corner pieces and GI 4mm dia suspenders with utterfly clips, wall angle of size 24 x 24mm, main runner (teee) of size 24 x 38mm, cross tee of size 24 x 28mm, (No of suspenders shall be decided by the GE as per actual size requirement) including 4mm thick non asbestos fibre cement plain builiding boards fixed to aluminum snap grid and providing two coats of white wash including preparation of surfaces including dismantling wall and ceiling board, any thickness includiing cover fillets if any all complete all as specified and as directed
M&L for Solid PVC Wall Lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications complete all as specified and as directed .
Taking down cement plaster on brick or stone walls, etc .including raking out joints, hacking for key, scrubing down with water etc .complete all as specified and as directed
M & L 15mm thick rendering on brick work or concrete surface in cm 1:4 to be fair and even with out using extra cement complete all as specified and as directed
M&L for rendering 15 mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement complete all as specified and as directed
M & L preparation of new decorated surfaces of external walls and applying two coat of cement base paint over a coat of primer complete as specified and directed
Preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 to 2 mm thick wall care putty over a coat of primer on walls etc complete all as specified and as directed
Demolition of cement concrete (unreinforced) ground floor to 3rd floors and pavings n exc 15 cm thickness (below or above ground level ) and removing unserviceable material exc 100 mtr complete all as specified and as directed
M&L for 25mm thick PCC type BO 1:2:4 (12.5mm graded aggregate in flooring finishing rough to recieveing Top layer for flooring complete all as specified and directed.
S&F vitrified ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, in floors etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and as directed
M&L for screed bed or bedding layer of cement mortar 15mm thick in CM 1:6 for laying floor finish complete all as specified and as directed
S&F vitrified ceramic tiles 10mm thick,(square/rectangular ) polished ,light shade area of each tiles not exceeding 0.36sqm, on vertical surface such as skritting etc.set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade complete all as specified and as directed
Machine cut kota stone flooring 18-20 mm thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone including grinding and polishing ( mirror finish) (Each stone not less than 55 cms x 55 cms) over 25mm thick PCC (1:2:4) type B1 over 15mm thick screed bed in CM ( 1:4) as in floor finished rough and applying a coat of cement slurry @ 03 Kg/Sqm of surface complete all as pecified and directed.
Chequered cement concrete coloured tiles 30 cm x 30 cm x 25 mm thick set , jointed and pointed in neat cement slurry with grey cement and pigment in floors complete all as specified and as directed
M&L for Screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:6 complete all as specified and as directed
M&L for PCC (1:3:6) 75 mm thick Type C-2, using 40mm graded stone aggregate as in floors in bed to recive tiles /path tiles etc complete all as specified and as directed .
M & L for PCC 1:2:4 type B-1 as in benching coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills etc complete all as specified and as directed .
Taking down chowkats or frames with shutter (with out taking off shutter from the frame) exc 1.5 sqm & n. exe 4 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed
Taking down chowkats or frames with shutter (with out taking off shutter from the frame) n exc 1.5 sqm each incl cutting holes for taking out hold fast or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.) complete all as specified and as directed
S&F Aluminum frame of natural anodized aluminum min 1.5mm thick of size 101.60x44.45mm Powder coated including necessary jointing cleats and fixing frame to wall/floor complete in all respect as per manufacture instructions and incluiding making good disturbed surfaces complete all as specified and directed by Engr-in-charge (Aluminum frame will be provided with/without groves & to accommodate glass, grill etc as per site requirement). complete all as specified and as directed
S&F aluminum doors shutter powder coated air tight with natural anodized party glazed with and including 5mm thick tinted glass and party panel with and including 12mm thick prelaminated particle board (All aluminum member Top, Bottom, Vertical & Middle of shutter made of size 82.55 x 44.45 x 1.50mm thick (Minimum) including necessary cleats glazing clips, 5mm thick tinted glass, rubber packing with anodized aluminium beading/glazing clip size 19.00 x 17.30 x 0.70mm wt 0.097 Kg/RM of both side and fixing aluuminum fitting ie SS hinges 100mm three numbers, handles 200mm long two number, tower bolts 150mm two numbers and mortize lock with 06 lever one number in each leaf and Incl "C" Channel and roller for sliding purpose and incl making good the distrubed surface complete in all respect . All aluminum member and fitting should be ISI marked complete in all respect as per manufacture instructions complete all as specified and as directed
M&L for powder coated Anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and as directed
S&F butt hinges of mild steel cold rolled medium weight of size 100mm complete all as specified and as directed
S&F Aluminium anodised, barrel tower bolts size 200 mm of extruded section and fixed complete all as specified and as directed
S&F Aluminium handles, cast type, anodised Size-150mm, anodised section and fixed complete all as specified and as directed
M L for preparation of old plastered surfaces of walls, & applying two coats of oil bound distemper complete all as specified and as directed
M & L for preparation of old decorated plastered /concrete/ brick surfaces of walls (up to 3rd storey with necessary scaffolding) and applying one coat of cement based paint on old decorated surfaces including preparation.complete all as specified and as directed
M&L for Reinforced cement concrete 1:2:4 (nominal mix) as in slabs supported on walls, beams and coloumns and the like slab laid in slops all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed
M&L 18 to 20 mm thick Granite black (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, over 15 mm thick CM 1:4 complete all as specified and as directed
M&L Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed
S & F in repair bib taps 15mm bore cast copper alloy chromonium plated with, screwed down, screwed for iron pipe complete all as specified and as directed
S&F for Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mmx460mm with bowl size 410mm x330mm x 160mm complete all as specified and as directed Make: Prayag, Cat No- 1216D & equivalent in Nirali, Jayana.
M & L TMT bar but 5mm dia and over upto and including 10mm dia in stirrups, spacers and bindersincluding cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed
M&L for colored non skid ceramic tiles 7to 8 mm thick, area of each tile exc 0.11 sqm but n exc 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in colored cement over and incl 10 mm thick screed bed or bedding layers of cement mortar 1:4 to match Shade, pattern, laying as in skritting etc of tiles complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed
M&L for glazed ceremic tiles 350x250x7 mm/450x350x7mm thick, as in dado, vertical surfaces set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles laid over and including 10 mm thick rendering in CM (1:4) complete all as specfied and directed.
Taking up or down steel tubing for 15mm dia pipe and connections including cleaning for re-fixing or removal to store.complete all as specified and as directed
M&L for 15mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed
Taking up or down steel tubing for 20mm dia pipe and connections including cleaning for re-fixing or removal to store.complete all as specified and as directed
M&L for 20mm dia bore galvanized steel water tubing, “medium grade,” together with all fittings; (ISI marked) such as elbows, bends tees, nipples, union sockets, sockets etc and short pieces and fixed complete to walls and ceilings or laid in floors complete all as specified and dirceted.
Precast cement concrete type B-1, 1:2:4 (20mm graded) aggregate as in manhole cover all as specifed including form work complete all as specified and as directed
M&L rendering 5mm thick in cm (1:3)as in ceiling , soffit of chajja etc.complete all as specified and as directed
M&L for applying three coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified and as directed
M&L machine pressed pre cast concrete interlocking paver ( with grey cement and pigment) any shape and size confirming to IS -15658-2006 of 60 mm thickness ,M-40 grade complete all as specified and as directed
Material and labour Roughening surface of old concrete, roofs by picking, sweeping clean and washing down with , Wire brushing and cleaning top surface of tiles, lime terracing or cement concrete, including flashings and junction of parapets, and use to neat cement slurry complete removing debris and rubbish from site complete all as specified and as directed
M&L for PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) with average thickness 50 mm laid in two layers of 25 mm thickness each with wire netting of 0.60 mm dia and size of mesh 12 mm x 12 mm laid between the two layers finished even and smoothes in roof padding all as specified and as directed Note:- The wire mesh shall be measured and paid for separately under the respective item
Supply only 25 mm size, wire netting of galvanized iron chicken mesh, 0.71 mm dia complete all as specified and directed.
Material and labour APP based polymeric membrane minimum weighing 3.5 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified laid over a coat of bituminous primer @ 0.40 ltr /Sqm & finished with applying bitumen grade 85/25 coat @ 1.2 Kg /Sqm. APP membrane shall be laid by torching with 75mm overlap in longitudinal direction and 100mm overlap in transverse direction all as directed and finished with applying one coat of aluminium paint as directed by Engineer-in-Charge and laid as per paticular specification complete all as specified and as directed
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of internal diameter 150mm complete all as specified.
M&L for Reinforced concrete pipes, class NP2, 200 mm bore laid and jointed complete with collars complete all as specified and as directed
Concrete bed to drain pipes including forming cradles in cement concrete 1:4:8 type D2 for 200mm bore NP2 pipes complete all as specified and as directed
Demolition of existing soakage well & septic tank and removing the all sludge outside the MOD land complete all as specified and direced.
S&F On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc complete for 30 user conventional type complete all as specified and as directed
M&L for Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.80m dia X 3.0m effective depth complete all as specified and as directed
Taking down carefully unserviceable Aluminium point wiring complete (light, fan socket, bell or power) with fitting such as switches, ceiling rose lamp holder, regulators, sockets, light fittings etc. and keeping in safe custedy for taking credit all as specified and as directed
Taking down ceiling fan/Exhaust fan any sweep, removing blades ,cleaning the fan completely for dust and dirt, oiling & greasing and hanging the same back to its original positions including connecting with three core flexible copper wire to ceiling rose etc after the completion of the point wiring including replacement of old unserviceable fan hook, rubber pad, nut bolts and washers etc, complete, all as specified and directed
M&L for Point wiring using FRLSH PVC insulated unsheathed multi strand copper conductor cable 1100 volt garde 1.5 sqmm including 1.5 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor earth wire drawn through and including non metallic rigid PVC conduit medium grade ISI marked not less than 20mm dia ,concealed in wall and surface on ceiling with all conduit fittings & fixing acessories inculding sunken anodised pressed steel terminal box not less than 1.2mm thick covered with 3 mm thick plastic laminated sheet cover of suitable size with brass screws for mounting switches , sockets , fan regulators etc incl testing and making good to disturbed surface to match existing surface for one light/fan/bell point complete all as specified and directed.
All As per Srl item N0 70 above but for one socket out let 5Amp controlled by one switch on same board with other switch .
All As per Srl item N0 70 above for one socket out let 5 Amp controlled by one switch on independent board with other switch .
All as per item No 70 above but point wiring with 2.5sqmm FRLS multi stranded copper conductor cable for main circuit and 2.5sqmm cable as earth continuity conductor for one 15 Amp socket out let controlled by one 15 Amp switch on independat board.
All as per item No 70 above but point wiring with 4 sqmm FRLS multi stranded copper conductor cable for main circuit and 4 sqmm cable as earth continuity conductor for controlled by two pin and earth plug and socket complete all as specified and directed
S&F Single pole & neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 amp 240V complete all as specified and as directed
S&F switch piano flush type 5 Amps single pole one way complete all as specified and as directed
S&F switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and as directed
S&F switch socket combination 2 in 1 5 pin 5 /15 Amps flush type complete.
S&F of ceiling rose 3 terminal complete PVC/Polycarbonate isolated boly complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc as required all as specified and directed.
Supply and fixing LED lights fitting 1x 18 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) compatible conventional fan regulator complete all as specified and as directed .
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed .
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed
S&F sheet metal enclosure distribution board SPN 12 way 230 V, 50 Hz double door with neutral, Earthing bar and din rail complete incl taking out existing UNSV DB with MCBs. complete all as specified and as directed
S&F MCB SPN 40 A to 63 A 10 KA 240 volts "C" series complete all as specified and as directed
S&F MCB single pole 5 to 32 Amps 10 KA 240 volts "C" series complete all as specified and as directed
S&F sheet metal enclosure double door for distribution board factory made for MCB DB load link vertical TPN 4 way suitable for MCCBas incomer, 125 Amp,4 pole. (when MCB's are to be used) with suitable size of busbar complete,fixed flush in wall including chases wall for fixing DB and making good the distributed wall surfaces to match with existing specification including taking downcomplete all as specified and as directed
S&F MCCB 125 A 4Pole 16KA 415 Volt with fixed magnetic and fixed thermal setting complete all as specified and as directed
S&F MCB SP 63 Amps 10 KA 230 volts "C" series complete all as specified and as directed
S&F building security light luminaries energy saving and envirnment friendly long life LED light of 25W made up of pressure die cast aluminium housing with acrylic cover as diffuser with IP66 protection and Impact resistanve of IK07, including GI bracket light grade 25 mm dia, 1.2 m long bend in shape fixed on wall having an angle 120 degree, fixed with and including two nos 25x4 mm size flat mild steel clamp made to shape and suitable size nuts, bolts and washers etc including taking down of existing light fitting and complete ,all as specified and directed.
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6 sq mm as earth continuity conductor connected to commen earth and earth dolly complete incl taking out existing UNSV service connections.complete all as specified and as directed
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh of 22 gauge, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI pit shall be filled with charcoal dust and common salt all as shown in electrical plate No 3 of MES SSR Part-I (2009) as specified including provision of 15mm dia medium grade GI pipe for earth wire protection and 20 mm dia for watering complete , all excavation and earth work & connecting the earthing to an earthing test point / main switch board as specified and testing on completion complete all as specified and as directed
S & F Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified.
S & F Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified and as directed
S & F Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified and as directed
S & F Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified and as directed
S & F Modular white cover plate incl Modular base frame/boxes & powder coated Modular sheet metal concealed box for 6 module complete all as specified and as directed
All as per Item No-99 above but 3 module complete all as specified and as directed
All as per Item No-99 above but 2 module complete all as specified and as directed
All as per Item No-99 above but 8 module complete all as specified and as directed
All as per Item No-99 above but 12 module complete all as specified and as directed
S & F Modular blanking plates 1 module complete all as specified and as directed
S &F LED sleek surface round ceiling mounted decorative down light fitting with PC cover suitable for 1x12 watt complete all as specified and as directed Make : Cat No BGSLO sleek surface 12 WH RD of Bajaj or equivalent in Havells / Polycab.
Supply and fixing swing type wall mounting fan 400 mm sweep single phase AC 230/240V complete for wall mounting incl grouting, holding down bolts, nuts, and provision of flexible copper conductor cable 3 core 23/0.0076 size from ceiling rose to fan complete all as specified and as directed . Make per model No Airboll Hi-speed of Havells and equivalent in Bajaj / CG.
M&L for sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 20 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 6.0 sq mm as earth continuity conductor connected to commen earth and earth dolly incl taking out existing UNSV service connections.complete all as specified and as directed
Sub main wiring with two single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 Sq mm drawing through and including concealed rigid non metallic PVC conduit medium grade ISI marked 25 mm dia including one single core FRLS PVC insulated unsheathed 1100 volts grade cable with stranded copper conductor of size 10 sq mm as earth continuity conductor connected to commen earth and earth dolly complete all as specified and as directed
Supply and fixing wall mounted busbar chamber 415V, 3 Phase 4 wire, 50Hz AC supply system fabricated from stainless steel with 3mm thick for outer cell TPN aluminium busbar of cap 100 Amp 4 pole 8 ways complete all as specified and as directed Make : Havells cat part No : IHBC010008 or equivalent in approved make.
Supply,installation,connecting, testing & commissioning Split AC 2.0 Ton capacity hot & cold, reversible cycle non CFC refrigerant including cutting of wall /window & grouting of nut bolts frame 60cmx40cm of angle iron of size 40x40x6mm thick etc. for installation AC's. Making good disturbed surfaces by means of using sand, cement etc. complete all as specified & directed Make : Hitachi/Ogeneral/Voltas (Note :- A.C. Should be minimum 3 star rated under BEE Label) .
S&F Voltage stabilizer 6 KVA, input voltage range 90 volt to 280volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc. complete all as specified and as directed Make :V-Guard/Johnson/BlueStar
Karmnaya Construction
Nitika electricals and engineers works
RAJINDRA ENGINEERS & CONTRACTORS
M/S. RAM PAUL KHAJURIA & BROS.
STAR CONSTRUCTIONS
M/S MANISHA BUILDERS
Hare krishna engineering const.
BHARTI CONSTRUCTIONS
SUNIL AND CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .