Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.0 LQualified 001 CLUB ROAD RAMNA HARISHBHA CHOWK MUZAFFARPUR BIHAR 842001 | MUZAFFARPUR | BIHAR | 842001 | L1 | Qualified MII | |
| 2 | L2₹5.3 L+₹33,400 (6.74%)Qualified 00 NEAR WORKERS CLUB SHOBHAPUR COLONY BETUL MADHYA PRADESH 460001 | BETUL | MADHYA PRADESH | 460001 | L2 | Qualified MII | |
| 3 | L3₹6.4 L+₹1.4 L (29.1%)Qualified 0 GOPAL GANJ CHABUTRA KE SAMNE PRATAPGARH PRATAPGARH PRATAPGARH RAJASTHAN 312605 | PRATAPGARH | RAJASTHAN | 312605 | L3 | Qualified MII | |
| 4 | L4₹2.5 Cr+₹2.5 Cr (5005.6%)Qualified CHENNAI TAMIL NADU 600032 INDIA | CHENNAI | TAMIL NADU | 600032 | L4 | Qualified MSE, MII |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
3 Mar 2022, 8:00 pmClosed
REPAIR AND REPLACEMENT OF UNSV LT PANEL BOARD OF
3177526
GEM/2022/B/1975343
REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANG
10 days
Karnataka; Bengaluru Urban
Total value wise evaluation
BOQ
5 documents required · 5 mandatory
3 yrs
₹3 L
80%
Exempted
3 Mar 2022
21 Feb 2022
3 Mar 2022
| Item No | Item Title | Description | Qty | Unit | Consignee | Delivery (days) |
|---|---|---|---|---|---|---|
| 1 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.1 | Taking down carefully the existing aluminium point wiring of any size and capacity and type by disconnecting from the either terminals complete including fittings and fixtures such as switches, sockets,ceiling rose, regulators and light fittings any type etc by unscrewing and taken away from site complete. Note :The cost of unserviceable materials will be charged from the contractor against schedule of credit. | 2 | Each Job | Bangalore | 10 |
| 2 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.2 | Supplying, fabricating, erect, test and commissioning indoor type cubicle LT distribution main panel board of suitable sizeat Aerodynamics plant of existing size totally enclosed, weather and vermin proof, suitable ventilated, 440 volts 50 HZ, AC supply, factory made fully compartamentalised made out of 2 mm thick CRCA sheet steel for load bearing and 2.0 mm thick non load bearing portions, protection of encloser IP-54 as per IS/IEC 61439-1&2 rated fault of 65 KA with internal arc containment CPRI approved complete with pretreatment and powder coating of approved colour incuding suitale angle iron/flat iron frame work/support, excavatiion and earth work, PCC foundations etc as per existing size inclludings the following, supplied fitted and connected internally complete. | 1 | Each Job | Bangalore | 10 |
| 3 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.3 | (a) 03 Nos Bus bar of equal size of aluminium conductor bus bar with PVC coloured heat shrinkable type sleeves continuous rating 400 Amp and 01 Nos bus bar aluminium conductor rating 200 Amps mounted on non cracting resing type insulators with CTs digital type KWH meter, amemeter and voltmeter with selector switch, etc of LED type indicating lamps R,Y,B on incoming side. | 1 | Each Job | Bangalore | 10 |
| 4 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.4 | (b) MCCB 4 Pole 250 Amp 36 KA, 415 Volt, 50 HZmagnetic thermal release as main incoming Make : Schneider/Seimens/ABB/L&T /Havells | 1 | Each Job | Bangalore | 10 |
| 5 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.5 | (c) MCCB 3 Pole100 Amp 36 KA, 415 Volt, 50 HZ and FASD starter of cap 40 HP complete with auxillary contactor 40 Amp including relay 01Nos and timer and single phase Preventor 415 V, voltmeter and amperemeter for compressor including making all connection and interlocking complete as per existing -02 Nos Make : Schneider/Seimens/ABB/L&T /Havells | 1 | Each Job | Bangalore | 10 |
| 6 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.6 | (d) MCCB 3 Pole 63 Amp 25 KA, 415 Volt, 50 HZ and FASD starter of cap 7.5HP complete with auxillary contactor 25 Amp including relay 01Nos and timer and single phase Preventor 415 V, voltmeter/ameter for AHU including making all connection with AHU and interlocking wiring complete as per existing -01 Nos Make : Schneider/Seimens/ABB/L&T/Havells | 1 | Each Job | Bangalore | 10 |
| 7 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.7 | (e) MCCB 3 Pole 63 Amp 25 KA, 415 Volt, 50 HZ and DOL starter of cap 5 HP complete with auxillary contactor including relay 01Nos, timer,single phase Preventor 415 V, including making all connection with pump and interlocking wiring complete as per existing -02 Nos Make : Schneider/Seimens/ABB/L&T | 1 | Each Job | Bangalore | 10 |
| 8 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.8 | (f) MCB 3 Pole 63 Amp 25 KA, 415 Volt, 50 HZ and DOL starter of cap 2 HP complete with auxillary contactor including relay 01Nos, timer,single phase Preventor 415 V, for CT Fan including making all connection with CT Fan and interlocking wiring complete as per existing -01 Nos Make : Schneider/Seimens/ABB/L&T/Havells | 1 | Each Job | Bangalore | 10 |
| 9 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.9 | (g) MCB 3 Pole 63 Amp 25 KA, 415 Volt, 50 HZ including making connection for heater and interlocking wiring complete as per existing -02 Nos ( These MCB will be assemble in single compartment) Make : Schneider/Seimens/ABB/L&T/Havells | 1 | Each Job | Bangalore | 10 |
| 10 | REPAIR /REPLACEMENT OF UNSERVICEABLE LT PANEL BOARD OF A&K AND FALCON BUILDING AC PLANT AT ADE BANGALORE Item No.10 | (j) Indication : Green (ON) & Red (OFF) for main ACB | 1 | Each Job | Bangalore | 10 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_3177526.pdf
GEM_BID
e3_2022-02-21-19-31-11_2fc6a638a06e95f402911d3f03655844.pdf
BOQ
boq_item_sample_file_2022-02-21-19-31-11_df509c2b5ae2dfd19c27c8f3fdcc724c.csv
BOQ
termsCondition.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .