Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹11.4 L+₹87,346 (8.27%)Rejected-AOC | L2 | Rejected-AOC MORE THAN LOWEST | |
| 3 | L3₹12.5 L+₹1.9 L (18.4%)Rejected-AOC | L3 | Rejected-AOC MORE THAN LOWEST | |
| 4 | L4₹12.9 L+₹2.3 L (21.7%)Rejected-AOC M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | L4 | Rejected-AOC MORE THAN LOWEST | |
| 5 | L5₹13.4 L+₹2.9 L (27.1%)Rejected-AOC D 55 HAKIKAT RAI RD ADARSH NAGAR DELHI 33 | L5 | Rejected-AOC MORE THAN LOWEST |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Jan 2021, 6:00 pmClosed
GE (NORTH) MAMUN
GE (NORTH) MAMUN C/O 56 APO
REPAIR/ MAINTENANCE OF DIFFERENT TYPE OF WATER COOLER, DESERT COOLER, AIR CONDITIONER, REFRIGERATION, DEEP FREEZERS INCLUDING MISC WORKS UNDER AGE E/M-II OF GE (N) MAMUN.
2020_MES_401449_1
GE(N)/M- /2020-21 NIT-58
Open Tender
Civil Works
Item Rate
270 days
GE (N) Mamun
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (N) Mamun
₹30,000
Yes
19 Feb 2021
7 Dec 2020
7 Jan 2021
7 Dec 2020
5 Jan 2021
22 Dec 2020
Amount
Taking down the compressor unit carefuly from the water cooler of Cap 40/80Ltr any make and any cap and exchange it with the company vide latest new compressor and tested certificat by the company (Purchase Vr, test certificate, warranty is to be furnished by the contractor to the Engr-in-Charge in token of purchase and serviceability). Fixing of sealed unit and charging of refrigerant gas (environment friendly) including testing the complete unit for required performance and smooth functioning for 24Hrs all as spd and directed by Engr-in-Charge.(Note 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs). Make : Emerson Copeland/Voltas/Sidwal/Usha/Blue star
All as per Srl item No 01 above but of 60/120 Ltrs capacity . Make : Emerson Copeland/Voltas/Sidwal/Usha/Blue star
All as per Srl item No 01 above but of 150/150 Ltrs capacity . Make : Emerson Copeland /Voltas /Sidwal/Usha/Blue star
Supply and replacement of Starting capacitor 80/100 Mfd for water cooler Make :Havells /Asian/Texla.
Supply and replacement of running capacitor 10/15 Mfd for water cooler . Make: Tibcon/EPCOS/Texla.
Supply and replacement of push cock 15mm dia chromium plated inner & outer thread as per sample
Supply and replacing of blower fan blade for water cooler suitable for 1/10HP & 1/35 HP fan motor only including nuts/bolts any make and any capacity.
Supply and replacement of starting relay 85002 suitable for water coolers of any make and capacity Make: Kirloskar/Sri Ram/Hi Tech/Technomech.
Supply and replacing of unserviceable blower motor 1/10HP for water cooler 60/120 & 150/150 ltrs capacity including nuts/bolts single phase, 230volt AC, Make. Universel/AUE/Airmaster
Supply and replacing of unserviceable blower motor 1/35HP for water cooler 40/80 Ltrs including nuts/bolts single phase, 230volt AC, Make.Universel/AUE/Airmaster
Supply and replacement of thermostat switch for water cooler any capacity. Make: Renutral/Indofoss/Annapurna.
Supply and replacement of condensing coil suitable for Water Cooler of capacity 40/80,60/120,150/150 Ltrs including welding/soldering, at site complete all as spd and directed. As per sample
Supply and replacement of OLP of water cooler any cap as per sample
Supply and replacement of PVC connection pipe for water cooler any cap as per sample
Supply and replacement of old unsv copper bound Fan motor with frame legs and nut, bolts including iron blade for desert cooler 1350RPM or 1/7HP single phase 220 volt 50C/S, 375-450mm including fixing nut bolts of desert cooler and making necessary electrical connection and testing complete all as specified .Make Khaitan/Aristo/AirMaster/Cool home
M&L for rewinding of desert cooler fan motor of 1/7HP /1/8 HP single phase 3 speed with super ennamelled copper wire of appropriate gauge with insulating material complete after removing old burnt wire including servicing change the unserviceable bush, shaft and testing after completion , complete all as specified and directed by Engr-in - charge.
S&F in replacement of old unsv water lifting submersible pump for Desert cooler single phase 220-240volts,50Hz including connection lead, 18watt complete all as specifed and directed.Make Khaitan/Aristo/AirMaster/Cool home
Supply and replacement 3 way PVC water distributor for desert cooler including nuts and bolts suitable size & PVC elbow . As per sample
Supply and replacement of capacitor 4mfd for desert cooler Make: Havells/Tibcon/Texla and making all necessary electrical connection.
Supply and replacement front grill complete with flexible louvers for circulating of air made out of 22gauge GI sheet for desert cooler (any make and any size) size all as per site requirement including making holes, nuts and bolts for fixing.
Supply and replacement three way speed control switch including 5Amp switch rotary type for desert cooler of make as per sample and making all the necessary electrical connection.
Supply and replacement side grill, rear/ back grill for desert cooler made out 24gauge GI sheet (any make and any size) of desert cooler all as per site requirement.
Replacement PVC float valve assembly with PVC float valve 15mm dia suitable for water cooler/desert cooler. Make as per sample
Replacement Water tank for desert cooler made out 24 gauge GI sheet including suitable size of nuts & bolts for fixing arrangment (any make and any size) of desert cooler) all as per sample.
Supply and Fixing side pillar made out of 24 gauge GI sheet including suitable size of nut and bolts for fixing arrangement as per sample
Supply and replacement PVC flexible pipe 15mm dia for Desert Cooler as per site requirement and making necessary connection for free flow of water.all as per sample
Supply and replacement Iron Fan blade for desert cooler any make and any size all as per sample
Supply and replacement Front patti for desert cooler any make and any size all as per sample
Supply and replacement of cooler body top made of out 24 gauge GI sheet suitable size for desert cooler including suitable size of nuts & bolts for fixing arrangement as per sample
Supply & replacement Plug top 5/6 Amps , 230V with connection copper lead 1.5m long suitable for 5/6Amps socket etc for desert cooler, Refrigerator complete all as specified and directed.
Replacement of PCB circuit, display with remote suitable for Split type AC 1.5 Ton Make Mistbishi hot & cold Srl No 8001856T & 92412462 BE Model No MSZ-HP18 VA & SRK18CS-S6 including all electrical connections at site complete all as spd and directed suitable for site requirement. As per sample.
Taking down the Aqua guard carefully from the site for servicing /cleaning including replacement filter, ultra violet rod, micro carbon sand, UV membrane ,PVC pipe 15mm with nut bolts, washers complete refixing the Aqua Guard to its original position and testing complete.
Supply and replacement of capacitor 50+ 6Mfd, 6 /8 pin for window/split AC. Make: Havelles/Asian/Crompton Greaves/Texla.
Scratching out of old paint by blower lamp, making the smooth surface incl denting of desert coolers. Apply two coats of enamel paint as per existing colour after one coat of red oxide as primer all as directed by Engr-in-Charge.
Scratching out of old paint by blower lamp, making the smooth surface incl denting of water coolers of any size. Apply two coats of enamel paint as per existing colour after one coat of red oxide as primer all as directed by Engr-in-Charge.
Taking down the compressor unit carefully from window type AC of Cap 1.5Ton of any make and exchange it with the new compressor suitable to the fixed in any make/Model of AC and tested by the company (Purchase Vr, test certficate, warranty is to be furnished by the contractor to the Engr-in-Charge in token of purchase and serviceablility). fixing of sealed unit and charging of refrigerant gas R-22 (enivronment friendly) including testing the complete unit for required perfomance and smooth functioning for 24Hrs all as specified and directed by Engr-in-Charge.(Note 1. All Engineering works shall be carried out at site/E/M store yard only in presence of JE/Engr- in- Charge. 2. No equipment shall be transport/carry out to local market for repairs). Make : Emerson Copeland /Haier /Whirlpool/Voltas/BlueStar/LG
All as per Srl item No 36 above but of window type AC 2Ton.Make : Emerson Copeland/ Haier/ Whirlpool/Voltas/BlueStar/LG
All as per Srl item No 36 above but of Split AC 1.5 Ton.Make : Emerson Copeland/ Haier/ Whirlpool /Voltas/BlueStar/LG
All as per Srl item No 36 above but of Split AC 2Ton.Make : Emerson Copeland/Haier /Whirlpool /Voltas/ BlueStar/LG
Replacement of electric blower motor double shaft having capacity 1/5HP/1/7HP for 1.5/2 Ton window type AC complete all as spd and directed by Engr-in-Charge.Make : Airmaster /AUE/Universal
Replacement of sheet metal enclosure with plug, socket and earth point and MCB 30Amps, SP 230volts Make: Legrand/Havells/Schneider.
Supply & Fixing Plug top for sheet metal enclosure as per sample
Replacement of condensor coil suitable for window type AC 1.5/2.0 Ton including welding/soldering at site complete all as spd and directed. As per sample
Replacement of Cooling coil suitable for window type AC 1.5/2.0 Ton including welding/soldering at site complete all as spd and directed.As per sample.
Replacement of PCB circuit with remote suitable for window type AC 1.5/2.0 Ton including all electrical connections at site complete all as spd and directed suitable for site requirement.As per sample.
Replacement of PCB circuit, display with remote suitable for Split type AC 1.5/2.0 Ton including all electrical connections at site complete all as spd and directed suitable for site requirement. As per sample.
S&F in replacement old unsv indoor unit for split AC 1.5Ton complete including PCB blower motor , swing motor and making the all connections all as directed by Engr-in-Charge. Make LG/Hitachi/Mitsubishi
S&F in replacement of old unsv outdoor unit for split AC 1.5Ton hot & cold complete with reverseble cycle valve compressor, fan etc. complete including making the all connections and charging the gas all as directed by Engr-in-Charge. Make LG/Hitachi/Mitsubishi
S&F in replacement old unsv indoor unit for split AC 2 Ton complete including PCB blower motor , swing motor and making the all connections all as directed by Engr-in-Charge. Make LG/Hitachi/Mitsubishi
S&F in replacement of old unsv outdoor unit for split AC 2 Ton complete with compressor, reversiblle cycle valve fan etc. complete including making the all connections and charging the gas all as directed by Engr-in-Charge. Make LG/Hitachi/Mitsubishi
Replacement of unserviceable AC cabinet incl all accessories like condensing coil, cooling coil/blower motor, Electronic controlling & remote, capilary,filter, reversible cycle valve hot & cold excluding compressor suitable for window type AC 1.5 Ton including all electrical connections at site complete all as spd and directed. Asper sample
Replacement of PVC front Grill suitable for window type AC 1.5/2.0 Ton at site complete all as spd and directed. Make LG,Voltas.
Supply & Fixing reversible cycle valve including brazing with suitable size of cooper for window & split AC any capacity
Replacement of electric blower motor Single shaft for out door unit capacity 1/10HP for 1.5Ton Split type AC complete all as spd and directed by Engr-in-Charge. As per sample
Charging Gas R-22 for AC 1.5/2.0 Ton any type including required brazing to pipe & connecting complete all as spd. (450gm gas in each Can)
Replacement of unserviceable Cooling blower for Split AC 2.0/1.5 Ton as per sample
Replacement of unserviceable Condensing fan motor for Split AC as per sample
Replacement of unserviceable Copper Pipe ½"
Replacement of unserviceable Copper Pipe ¼"
M&L for PVC insulated flexible copper conductor 3 core 4 Sq mm 1100volt grade, connected & testing complete all as spd.
M&L for PVC flexible waste condesing drain out pipe for split AC suitable size fixed properly on wall /floor etc. connetced propery all as directed
M&L for servicing of AC window /split upto 1.5/2Ton cap by means as cleaning & washing of AC with brushes /chemical etc. and change of filter etc. and all as directed incl taking down /refixing in position of AC connected & testing complete & all as directed.
M&L for angle iron frame works in repairs of size 25x25x4mm suitable for supporting of AC's & Desert Coolers, Water cooler securtiy wire mess structure complete with grouting In wall palced on floor incl rollers on floors etc. Make good the disturbed surfacs upto matched in existing incl required of cement /bricks etc complete all as directed
Taking down the compressor unit carefuly from the deep freezer of Cap 285Ltr/310Ltr any make and exchange it with the new compressor (Purchase Vr, test certificate, warranty is to be furnished by the contractor to the Engr-in-Charge in token of purchase and serviceability). Fixing of sealed unit and charging of refrigerant gas R-134A (environment friendly) including testing the complete unit for required performance and smooth functioning for 24Hrs all as spd and directed by Engr-in-Charge. All machinery works will be carried out at E/M store yard under direction of Engr-in-charge.
Replacement of starting relay suitable for deep freezers cap 285Ltrs/310Ltrs complete all as spd and directed . Make As per sample
Relacement of thermostat switch suitable for deep freezer cap 285Ltr/310Ltr complete all as specified & directed . Make : As per sample
Replacement of old unsv Blower motor for Deep Freezer 4x4 Make as per sample
M&L for replacement of Voltage stabilizer 04 KVA to 5KVA , input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc. Make Johnson/INTEG/Blue Star/Autronica/V Guard
M&L for replacement of Voltage stabilizer 2 KVA to 3 KVA, input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage complete with accessories etc. Make Johnson/INTEG/Blue Star/Autronica/V Guard
Taking down the compressor unit carefully from the refrigerator of Cap 286/310Ltr any make and exchange it with the new compressor (Purchase Vr, test certificate, warranty is to be furnished by the contractor to the Engr-in-Charge in token of Purchase and serviceablility) including and charging of refrigerant gas 134a (enivornment friendly). Testing the complete unit for required performance and smooth functioning for 24Hrs all as spd and directed by Engr-in-Charge. Make: Whirlpool/LG/Samsung/Godrej.
All as per Srl item No 70 above but of capacity 165/175Ltr capacity refrigerator of any Make: Whirlpool/LG/Samsung/Copeland/Godrej
Replacement of cooling coil assly suitable for refrigerator 286/310Ltrs capacity including nuts/bolts with door assly all as spd and directed by Engr-in-Charge. Make: LG/Whirpool/Kelvinator or any other As per sample.
All as per Srl item No 72 above but suitable for 165Ltr/175Ltr/180Ltr capacity refrigerator as per sample.
Replacement of copper filter of any type of refrigerator as per sample
Replacement of unserviceable timer for double door refrigerator. Make: LG/Samsung/Whirlpool.
Replacement of unserviceable biometer for double door refrigerator. Make: LG/ Samsung/Whirlpool.
Replacement of blower motor for double door refrigerator. Make LG/Samsung/ Whirlpool.
Replacement of unserviceable starting relay for Godrej refrigerator (PTCR with capacitor Make: Godrej/LG/Whirlpool.
Replacement of unserviceable starting relay for LG refrigerator as per sample. Make: Godrej/LG/Whirlpool.
Supply only Flame Gas cane for soldering summer appliances
Replacement of thermostate switch suitable for Refrigerator as per sample
Charging Gas R-134a for suitable summer appliances including required brazing to pipe & connecting complete all as spd.(450gm gas in each can)
Repair , rewinding and maint of voltage stabilizer of any make and capacity 4KVA up to 5 KVA after disconnecting the voltage stabilizer from machine, rewinding with super enamalled copper of existing gauge including replacement of u/s part like voltmeter, Amp meter, cut out relay, electric circuit, indicator lamp, Top plug, flexible wire including neccessary painting with two coats of synthetic enamel paint after proper sctretching and preparing the surface , complete all as specified and directed.
Repair , rewinding and maint of voltage stabilizer of any make and capacity 2KVA up to 3 KVA after disconnecting the voltage stabilizer from machine, rewinding with super enamalled copper of existing gauge including replacement of u/s part like voltmeter, Amp meter, cut out relay, electric circuit, indicator lamp, Top plug, flexible wire including neccessary painting with two coats of synthetic enamel paint after proper sctretching and preparing the surface , complete all as specified and directed.
Bulb Thread for Refrigerator 310/165/180 Ltr cap as per sample
S&F Capillery Tube suitable size 0.31 & 0.36mm suitable for Refrigerator & Deep Freezer as per sample
Gas charging pin valve for Refrigerator, Deep Freezer , water cooler & AC's as per sample
M/S NILESH ENTERPRISES
M/S SAROOP ELECTRICAL & MECHANICAL WORKS
Chanana Engineers & Contractors
GARG CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .