Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical | Accepted-Technical Fullfill All other Qualification Criteria |
| 2 | Accepted-Technical | Accepted-Technical Fullfill All other Qualification Criteria |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
7 Apr 2026, 6:00 pmClosed
EO NP Dhariyawad
Office of the EO NP Dhariyawad
02 - Nagar Palika kshetra me Pole lagane ka karya Dhariyawad.
2026_DLB_548727_2
NIT No 100/2025-26 NP Dhariyawad
Open Tender
Miscellaneous Works
Percentage
DHARIYAWAD
As per given in NIT and Conditions
3 documents required · 3 mandatory
₹1,000
As per NIT and Conditions
₹36,000
Yes
9 Apr 2026
27 Mar 2026
9 Apr 2026
27 Mar 2026
7 Apr 2026
27 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1As Per RUIDP SOR 2023 | |||||
| 2Supply and erection of P.C.C. poleasper REC manualno 15/1979 (ammended uptodate) andasper latest Discom specifications with factorofsafety 2.5 including excavation of pituptopole planting depth 1/6 thofpolelength.and back filling with stone aggregate /boulder sand soil by rammin gand watering etc complete asrequired. All as per preap proved by Engineer in-charge.For additional technical parameters of product /work refer Annexure 'A' attached with this BSR 9.0 Mtr long PCC pole of 200 Kg Working Load | |||||
| 3Supply and erection of GI stay set confirming to pattern-1 of BS:16/1974 and as per latest Discom Specifications complete with stay rod with anchor plate fitted with cast iron cross head and steel bow, in cement concrete 1:3:6 including excavation of pit-re-filling etc complete as reqd. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR Stay set of dia 20mm, 2.4m long stay rod and anchor plate 380 x 380 x 4.0 mm | |||||
| 4Supply and fixing of LT porcelain pin insulator as per IS 1445-1997 and as per Discom's standard specifications,suitable for working voltage 1100 volts including all accessories like MS Forged GI LT Pin confirming to IS:7935/1975 (latest amended) Nut, Bolt etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 100 mm x 70 mm | |||||
| 5Supply and fixing of following LT Supporting accessories with nut bolt & Clamps made out as per standard Discom's specifications with two coats of Red oxide and two coats of Aluminium paint etc. as required. All as per pre approved by Engineer in-charge.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR LT cross arm 1200 mm long with clamp | |||||
| 6Supplying and drawing of XLPE insulated LT Aerial bunched Aluminium conductor cable confirming to IS 14255/1995 and IS 398 (Pt-4)/ 1994 and as per Discom Specs. on existing cross arms through I hook with all necessary T&P required including binding and twisting etc. complete in all respect as required. All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . 1 X 25 sq. mm. + 1X25 sq. mm. (insulated) | |||||
stage.html
html • 0.02 MB
technical_978283.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.12 MB
Tendernotice_2.pdf
PDF • 22.42 MB
BOQ_978283.xls
BOQ • 0.28 MB
Corrigendum.pdf
PDF • 0.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .