| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-Finance | ₹1.5 Cr | L1 | Accepted-Finance LOWEST |
| 2 | L2₹1.5 Cr+₹3.4 L (2.29%)Rejected-Finance MONORANJAN APARTMENT GARALGACHA BENARAS ROAD NEAR PETROL PUMP P O GARALGACHA DANKUNI DIST HOOGHLY PIN 712311 WB | DANKUNI | HOOGHLY | WEST BENGAL | 712311 | ₹1.5 Cr+₹3.4 L (2.29%) | L2 | Rejected-Finance HIGHEST |
| 3 | L3₹1.7 Cr+₹18.1 L (12.1%)Rejected-Finance KRISHNAPUR P O GARALGHACHA P S CHANDITALA DANKUNI HOOGHLY PIN 712708 W B | DANKUNI | HOOGHLY | WEST BENGAL | 712708 | ₹1.7 Cr+₹18.1 L (12.1%) | L3 | Rejected-Finance HIGHEST |
Tender Value
Refer Docs
EMD Value
₹2.2 L
Closing Date
4 Nov 2022, 2:00 pmClosed
Superintending Engineer PWD Electrical
Superintending Engineer PWD North Bengal Electrical Circle P.W.D Inspection Bungalow Annex Building 1ST Floor Kutchery Road Venus More Siliguri
Electrical Installation works for the proposed Electric Crematorium under Darjeeling Municipality in the district of Darjeeling Supply Installation Testing and Commissioning of Double Furnace Electric Crematorium
2022_WBPWD_411836_1
WBPWD/SENBEC/NIT-03/2022-2023
Open Tender
ELECTRICAL WORKS ORG
Item Rate
120 days
Darjeeling
Please refer Tender documents.
4 documents required · 4 mandatory
₹2.2 L
Siliguri
16 Dec 2022
28 Sept 2022
7 Nov 2022
28 Sept 2022
4 Nov 2022
21 Oct 2022
19 Oct 2022
Amount
SUB-HEAD-I (E.I WORK AND SUPPLY & LAYING OF CABLE)
Supply, delivery of floor mounting cubicle compartmentalized 415 volt. 50Hz. Dust & moisture proof L.T distribution panel board fabricated from 16 SWG CRCA sheet for main L.T panel. The panel should have adequate strength and space to accommodate the incoming switches bus bars with all interconnection in between the switches & bus bars with solid copper rod/flexible wire of suitable capacity. The incoming terminals of SFU should be provided with extra copper bar of suitable capacity for smooth termination of double feeders. The panel board should be painted by powder coated paint and the lay out diagram of panel board should be approved by EIC before manufacturing. The panel board should comprise with the followings gadgets :-
Incomer i) S/F of 415 Volts 250-630A Microprocessor based MCCB --1No. (Make: L&T / ABB (Elegance) / Siemens / Schneider). Bus bar chamber :- ii) do-do 800 Amp capacity 99.9% - 99.5% electrolytic tinned copper 4 bar bus bar of suitable dimension mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification & all connection made with required size cu wires------1set.
Outgoing i)S/F of 415V, 400A Microprocessor based MCCB castle locking arrangement between two outgoings ---2nos (Make: L&T / ABB (Elegance) / Siemens / Schneider).-
Supply, installation, testing & commissioning CPRI approved cubical type panel board with separate compartmentalized floor mounted, indoor type dust and vermin proof powder coated panel board, suitable for 415V 3phase, 4wire,50Hz, A.C supply of suitable size made out of 14 SWG (2mm.) thick CRCA/M.S. sheet wih angle (50X50X6 mm) , flat ( 50 X 6 mm) structure with individually hinged capsule door for all compartment with lock ,providing ventilation arrangement & free standing from floor mounting . The control panel should have suitable cable entry from bottom of back through detachable gland plate (100mm.x40mm.x4mm.) thick M.S. channel to access sufficient no of incoming & outgoing cable Incl. suitable size G.I. net guard with key & locking arrengement with interconnection with adequate size cu. wire, copper bar, cu link, cable connector etc. along with necy. nuts, bolts, clamps, grouting bolts incl. providing and fixing the following accessories etc. complete as required. (Make: L&T / ABB (Elegance) / Siemens / Schneider) Incoming:- a) S & F 415A, 415V TPN Switch disconnector fuse unit open execution type with 3 Nos din type HRC fuse link--1 nos. Busbar :- S & F 415 V, 600 A current carrying capacity electrolytic grade tinned copper BBC of size having bus bar dimension of (4 x (2 x 40 mm x 5mm)) will be fixed on FRP Chair & the entire bars are insulated with PVC heat sinkable sleeves with suitable size & colour as per.
Outgoing Switch Fuse Unit: a) S & F 415V, 315A TPN Switch disconnector fuse unit open execution type with 3 Nos din type HRC fuse link--1 nos. b) S & F 415V, 63A TPN Switch disconnector fuse unit open execution type with 3 Nos din type HRC fuse link--3 nos.
Design, Engineering, maufacture, Supply, erection and commissioning of CPRI approved furnace Control Panel (Cubical panel) complete with all necessary switches, contactors, Instruments, indicating Lamp etc. The furnace Control Panel will be floor mounting, self supporting indoor type, dust & vermin proof Louver arrangement and fabrication from sheet metal work of 2.5 thick M.S. Sheet. The top, bottom and the rear door (where the instrument will be mounted) will be made from 3.15 mm thick M.S. Sheet. The approximate dimension of the panel will be 2250 mm(H)X1200(W)X1000mm(D). The panel will be painted two coats of red oxide as primer and final by synthetic light grey shade as per IS: 631 and comprising the followings:- Incoming: i) S & F of 415V, 315A TPN switch fuse unit open execution type incl. 3nos. Din type HRC fuse (Make: L&T / ABB (Elegance) / Siemens / Schneider).--- 1No. Bus Bar Arrangement: S & F 415V,415A current carrying capacity electrolytic grade tinned copper BBC (4 x 50mm x 5mm) in size for neutral & phases. The entire bars are insulated with PVC heat sinkable sleeve of suitable size & colour as per direction of E.I.C. -- 1 set.
Outgoing: a) S & F of 415V, 100A, TPN open execution type, with 3 nos. HRC Din type fuse. (Make: L&T / ABB (Elegance) / Siemens / Schneider) - 3 nos. b) S & F of 415V, 63A, TPN open execution type, with 3 nos. HRC Din type fuse. (Make: L&T / ABB (Elegance) / Siemens / Schneider) -4 nos. c) S & F of 415V, 32A, TPN open execution type, with 3 nos. HRC Din type fuse. (Make: L&T / ABB (Elegance) / Siemens / Schneider) -2 nos. d) S & F of 240V, 32A, DP main swith with rewireable type fuse . Make: (Make: L&T / ABB (Elegance) / Siemens / Schneider)-4nos. e) S & F of 2 no. 63A TP Power contactor of coil voltage 24V A.C. having 2 N.C. + 2 N.C. auxiliary contacts (Make: L&T / ABB (Elegance) / Siemens / Schneider). f) S & F of 1 no. 16A TP power contctor with Thermal O/L relay for controlling the fresh air motor. (Make: L&T / ABB (Elegance) / Siemens / Schneider)). g) S & F of 1 no. 25A TP power contactor with Thermal O/L relay for controlling the 3.7KW flue draught motor. (Make: L&T / ABB (Elegance) / Siemens / Schneider)). h) S& F of 1 set 16 amps reversing contactor with mechanical and electrical interlock with overload relay for forward and reverse operation of the door operating motor.
Supply & fixing of 415V sheet steel enclosure 63A TPN fuse switch unit on angle iron frame grouted on wall incl. 3nos. HRC type din fuse at basement level for local control the furnace heater group as per direction of EIC (Make: L&T / ABB (Elegance) / Siemens / Schneider)
Supplying and fixing 415V, 250A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. Incl. 2 nos cable end box. (Make: L&T / ABB (Elegance) / Siemens / Schneider)
S & Fixing of Manual operated Butterfly Valve for control of Fresh Air injection system from Buffer Tank.
Supply, installation, testing and commissioning of Fresh Air injection system including Forced Draft fan with 440V, 50 Hz, 1hp motor, Mild Steel ducting, butter fly valve etc. complete with set.
Supply & fixing the Thermocouple of heat sensing range 0 to 1200 degree celcious having (Cr.- Al) sensor housed in S.S 304 casing of dimension 1200 mm long x 22 mm OD complete encased to be and fitted terminal on other and for connection of Compensating wire of 2 cores 0.5 sq. mm. CR-AL for heat sensing from thermocouple to Temperature controller covered with asbestos embedded rope about 50 m length as per direction of EIC.
Supply & Fixing of 300x50x1.25mm (18SWG) perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of 25x25x3mm MS angle iron support.
Supply & laying of 1.1 KV grade 4 core 185 sq. mm. XLPE (AL) armoured cable from main L.T. panel to furnace control panel through cable trench/wall surface including S&F M.S saddles with earthing attachment in 2 nos 10 SWG G.I. wire making holes etc. as necessary mending good damages and painting as per direction of EIC. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster).
Supply & laying of 1.1 KV grade 4 core 185 sq. mm. XLPE (AL) armoured cable on existing Cable Tray and binding with suitable size GI wire. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster).
supply & Laying of 1.1kv grade 3core 10 sqmm XLPE (AL) armoured cable on existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster). (for recirculation pump and fresh air motor)
supply & Laying of 1.1kv grade 3core 16 sqmm XLPE (AL) armoured cable on existing covered masonry trench incl. taking out RC covers, setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster). (for blower motor)
supply & Laying of 1.1kv grade 4 core 16 sqmm XLPE (AL) armoured cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster) (for compound lighting)
Supply & laying of 1.1KV grade 3 core 50 sq. mm. HR PVC (AL) armoured cable from furnace control panel to furnace (at basement) in trench/wall surface/cable tray including S&F M.S saddles with earthing attachement in 1 no. 10 SWG G.I. wire making holes etc. as necessary mending good damages and painting as per direction of EIC. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster).
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of following sizes XLPE/PVC armoured cables
a) 4 core 185 sq. mm.
b) 3 core 50 sq. mm.
c) 3 core 16 sq. mm.
d) 4 core 16 sq. mm.
e) 3 core 10 sq. mm.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials.
a) 4 core 185 sq. mm.
b) 3 core 50 sq. mm.
c) 3 core 16 sq. mm.
d) 4 core 10 sq. mm.
e) 3 core 10 sq. mm.
Supply & fixing the heating element of capacity 4.5KW each for primary and secondary chamber to be working in supply voltage of 240V,50Hz made from 80/20 Ni-chrome wire of 8 SWG in coiled coil from welded S.S. studs on both ends. The coil should be inserted into the groove of existing coil brick and the S.S. studs housed into the ceramic collar tube wrapped with asbestos rope for light fitting including terminal connector of S.S. make with 8 SWG Copper (HDBC) with Insulated porcelain bids as per direction of EIC.
Electrical connections of all ancillary motors i.e. (a) Fresh Air Motor (b) Draft Motor (c) Door Lifting Motor (d) Drum controller etc. by expert electrician by jointing kits as required including Testing, commissioning.
Electrical connection of all the heating elements embedded in furnace to be grouped in a manner to operate it through contractor at starting position & running position as required including testing and Commissioning.
Supply and fixing of ceramic glazed tiles in the body of the furnace and the painting of the metal part of the furnace.
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
SUB-HEAD-II (STRUCTURAL ITEMS)
Supply and installation of complete structural work for furnace made out of 50 mm x 6 mm thick M.S. Angle, 75 mm x 50 m.m. M.S. channel and 3 mm thick M.S. Plate, Rear & Bottom side plate of adequate thickness and welded or bolted in proper manner and furnace door of electricity/manually operated made out of 16 mm plat duly welded in shape. Door Shall be internally lined with ceramic blanket etc. And as per direction of EIC.
Supply and fixing of 2 nos. cast iron door with hinge and locking arrangement from Removing arrangement for removing bones and ashes.
Supply and fixing of C.I. made counter weight. As per requirement.
Supply and fixing of manifold with a provision of three outlet, complete set and flue damper set, door guider and slide rails set and stainless steel duct for flue exhaust Path as per direction of EIC.
Supply & Delivery M.S. fabricated ash & bones collection Handle & Tray.as per specification.
SUB-HEAD-III (MECHANICAL ITEMS)
Supply and installation of two position cantilever type spring loaded body Charging trolley with handle. The trolley Shall be made out of suitable M.S. chequered plate for platforms complete with roller etc. before ricating the trolley, drawing shall be approved by site engineer and trolley shall be inspected Before delivery.
Supply & fixing of main door driving shafts with sprocket assembled - 1 set handle assembly for manually driven door operation 50 mm & 30 mm dia plumber block with bearing assembled (2 sets each) l" pitch roller chain 300 mm long with chain link.2 no. and 3/4 " pitch roller chain 1000 mm long with chain link as per difection of EIC.
SUB-HEAD-IV(REFRACTORY ITEMS)
Supply & installation of complete set of refractory shaped bricks for construction of electric cremation of I.S. 8 bricks (approx. 1007 nos. & wt. 13 m ton) insulation bricks 4000 nos. refractory slab for construction of flue duct passage inthe basement, as required, refractory heat resistant fire clay mortar of 40 bags, ceramic blanket 25 x 510 x 7120 mm Mill Board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks porlion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel Al. paints as per direction of EIC as follows:-
(a) Complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber and sufficient ventilation for Fresh air spraying. (b) Complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out ashes from the rear side and sufficient Ventilation for fresh air injection. (c) Complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for Fresh air injection to the ash chamber and cremation chamber.
SUB-HEAD-V(INTERNAL ELECTRIFICATION & LC SYSTEM)
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish (Average run 8Mts).
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. On board
Wiring with 1.1 KV grade single 2x1.5 sqmm wire incl. S&F 1x1.5 sqmm cu wire ECC core PVC insulated stranded Copper wire in 19 mm dia EI conduit and painting for low bay.
Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles.
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required.
a) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) as ECC (from TPNDB to SPNDB)
b) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC(for 15A power plug,computer board)
Supplying and fixing double door 6 way Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. INCOMING:- Supplying and fixing 415V 100A FP MCB Isolator on din rail of existing DBs and necessary connection - 1 No. OUTGOING:- Supplying and fixing 240V, 16A/32A SP MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection- 18 Nos. (Make: Siemens/ Schneider/ Legrand)
Supplying and fixing 250 V, 6-10A per way, (2+8)SPN MCBDB with SS enclosure double-door with IP-42/43 protection with DP Isolators as incomer and SPMCBs ('C' Curve, 10kA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment, 1no. 40A DP MCB Type Isolator, 8 no. 6-16A SPMCB) (Make: Siemens/ Schneider/ Legrand)
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.150x50x1.25mm (18SWG)
Supply & laying of 1.1 KV grade 4 core 35 sq. mm. XLPE (AL) armoured cable on existing Cable Tray and binding with suitable size GI wire. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster). (From L.T. Panel board outgoing switch to PBDB)
Supplying and fixing compression type gland for 1.1 KV grade 4 Core x 35 sqmm PVC armoured aluminium cable omplete with brass gland, brass ring & rubber ring for dust & moisture-proof entry including Finishing the end of armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials .
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch with indicator & 16A kit-kat flush type fuse (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
S & Fixing single/twin 4' LED tube light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. incl. s&f 1200mm 22W master LED tube.
Make Philips Cat no TMC 501P-1xT-LED20WP3241) incl. s&f 1x 1200mm 20W master LED tube or equivalent product of Crompton / Wipro having similar specification in all respect)
Make Philips Cat no TMC 502P-2xT-LED20WP3241) incl. s&f 2x 1200mm 20W master LED tube or equivalent product of Crompton / Wipro having similar specification in all respect)
Extra for suspension exceeding 25 cm. below the ceiling with S & F additional 2 nos. 20 mm. dia. E.I. conduit (14 S.W.G) supports & necy. PVC insulated ‘Cu’- wire as above.
Supplying & Fixing 9 Watt (Make- Philips / Wipro / Crompton) LED Lamp.
S&F 48" (1200mm) sweep A.C. ceiling fan complete with blades, canopy, fork, rubber, bush etc. including S&F connecting wire for down rod up to 30cm including painting the rod with approved paint and making necessary connection as required.(make - Crompton / HS Plus / 5 Star rated / Orient Energy Star / Usha, Striker Plus)
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.
Supplying & fixing of 300 mm dia (i.e., 12" dia) [EPC make] Heavy duty exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of dia 300 mm (i.e., 12" dia) including supply and fixing AL louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)suitable fo 23 cm Exhaust Fan.
Supplying & Fixing of Box type fan clamp of 150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F 12mm dia 600mm long MS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22 SWG steel binding wire, incl. supplying & covering the box with alkathene sheet, placed in order to prevent concrete from entering the box.
Supplying & Fixing 250 V AC/DC superior type Call Bell (Anchor-8320) on HW board incl. S&F HW board
Earthing in soft soil with 50 mm dia ISI Medium GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level & restoring surface duly rammed.
Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil
Connecting the equipments to earth busbar including S & F GI (Hot Dip) 6 SWG wire on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
S & F Lightning conductor Air-terminals made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4 SWG GI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plate at bottom incl. necessary holes etc. duly grouted at the top part of the chimney by making necessary arrangement as per direction of the E.I.C.
Supply & fixing of GI (Hot Dip) strips 20 mm x 3 mm thick for vertical run on Chimney outer surface with GI saddles/clamping arrangement spaced not exceeding 1000 mm apart
Making soldered joints between conductor/ down pipes / other metallic objects by 7/10 stranded GI (Hot Dip) wire incl. supply of jointing materials & painting with 2 (two) coats of Bituminous paint
S&F M.S net cover 3mm thick for motor covering (1x2ftx 3sides + 1x1ftx1side) [for recircullation pump guard)
Connecting the equipments body to earth busbar including S&F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts,
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required (50 mm dia)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation of Chimney (vertical run)
SUB-HEAD-VI (COMPOUND LIGHTING)
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Make: Finolex / Havell’s / Ploycab / RR / KEI / Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required . 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply and Laying of 1.1 KV grade 2Core x 6 sqmm PVC armoured aluminium cable after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish. (Make- Finolex / Havell’s / Ploycab / RR / KEI / Gloster)
Supplying and fixing compression type gland for 1.1 KV grade 2Core x 6 sqmm PVC armoured aluminium cable complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry including Finishing the end of armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials .
Fixing only LED street light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Supply& Fixing of 230V 72 Watt LED type street light fittings complete with set. (Make- Philips / Wipro / Crompton).
Supply and fixing 230V 120 Watt LED type flood light fittings complete with set. (Make- Philips / Wipro / Crompton) on top of masonary structure by 3 Nos. 10 mm dia x 87 mm long rag bolts, nuts & double washers complete either 37 mm x 10 mm MS flat support/or by other means as required.
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 16 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint
Supply of 6Mtrs height hot dip galvanised octagonal pole made of HT steel of grade S355 with 130 mm bottom A/F & 70 mm top A/F made up of 3mm thick G.I. sheet along with base plate of size 225 x 225 x 16 mm thick with inbuilt Sleek terminal box with required sizes studs for 4 core 16 sq mm A Al cable termination as required and 10A porceline fuse for each out going with proper pad locking arrangement (2 nos.) Make: Bajaj /TLL/Valmont /Transrail/Utkarsh/Jaquar).
Supply and Fixing of single arm header assembly fabricated from 40mm dia. GI Pipe (ISI-M) of following length rigidly welded with 80 mm dia. GI Pipe (ISI-M) of 0.3 Mtr. long as pole sleeves at an angle of 105⁰ including S/F 3Nos ½” MS jam nut each with 1No. ½” dia. through bolt, pole cap and painting as to GS of the entire assembly.
i) 1 mtr length
Erection of Single octagonal pole of length 6/8Mtrs with 4 nos. 20mm dia 600/700 mm length "J" type Bolt projected 100 mm & Nut etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block with hard jhama metal including 1300 mm depth x 500mm dia cylindrical type RCC (6:3:1) muffing and 0.50 mts. above ground level including 3 mm thick neat cemented finish and for alkathene/polythene pipe entry, for street light wiring, without Loop Box with GI earth bolt after making drilled holes etc. on base plate & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. Long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. Long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. Below the ground level as below: a) By ISI-Medium GI pipe. [G01 : 2a]
Supply & fixing compound light timer Control Unit(Indoor type) for Faculty building, Hostel Building compound and decorative light of Academic building, assembled with following accessories and wiring with 4sq.mm Cu wire(For MCB to Contractor/terminal block),1.5 sq.mm Cu wire(For control wiring). Suitable size 16 SWG CRCA sheet metal box having min depth 3.5" and should have adequate strength and space to accommodate the following accessories. i)32 A TP MCB(Make:L&T/Legrand/ABB)-1no as incommer ii)Digital 24 hour time switch(Make-GIC)-1no. iii)30A 3-Pole Power Contractor(L&T:Cat No-CS94101)-1no. iv)25 A TP MCB "C" curve(Make:L&T/Legrand/ABB) -1no as out going v) Toggle Switch(ON-OFF-ON)-1No vi) Out going terminal stud with nut--4sets. vii)Indication lamp (R,Y,B)- 1 Set. viii)EI Danger Board (6”X4”) – 1No. Metal Box should have gasket arrangement inside the door and entry and exit points of IN-OUT power, which protect the dust insertion and two locking arrangement with allen key. The panel box should be painted by powder coated paint & the layout diagram of the panel board should be approved by the E.I.C before manufacturing
Earthing with Copper plate (610 x 610 x 3mm size) having weight of 9.84 Kg and 1 No. 25 x 5mm Copper strip (3.20 mt long) & 1 no. 6 sqmm PVC insulated stranded Copper wire (4 Mt long) incl. S & F 15 mm dia GI pipe (ISI-Medium) protection (4 mt. long) to be fillied with bitumen, partly under the ground level & partly above ground level as per detail specification attached (uploaded in the specification section) [FOR 2 nos. Furnace and LT panel earthing
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos.12 mm dia holes on the GI pipe
Extra treatment of soil by using salt & charcoal for plate electrode as to G.S.
Excavation of soil for installation of Earth Electrode and filling & ramming.
Supply & fixing earth busbar of galvanized (Hot dip) MS flat 65 mm x 8 mm on wall having clearence of 6 mm from wall incl. providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
SUB-HEAD-VII (POLLUTION CONTROL WORKS)
Design, Engineering, maufacture, Supply, delivery at site , installation ,testing and commssioning of SS fabricated Venturi with packed wet scrubber and accessories complete including pipeing as required . As per technical specification
Design, Engineering, maufacture,Supply, delivery at site, installation, testing and commssioning of Mist eleminator with all accessories complete As per technical specification
Design, Engineering, maufacture, Supply, delivery at site , installation ,testing and commssioning of induced draught fan and other accessories complete with suitable rain protecting hood.
Design, Engineering, maufacture, Supply, delivery at site , installation ,testing and commssioning of SS fabricated ducting to connect existing furnace duct with the pollution control unit with auto/manual dumper control arrangement as per technical specification
Design, Engineering, maufacture, Supply, delivery at site , installation ,testing and commssioning of MS self supported chimney of 30 mtr. Length. MS ladder, inspection door. Operating plantfrom aviation lamp.
Design, Engineering, maufacture, Supply, delivery at site , installation ,testing and commssioning of Recirculation watrer pump alongwith necessary pipeline and accessories complete as required as per technical specification.
Supply, delivery at site , installation ,testing and commssioning of 1/2 HP pump motor set and making connection with supply and delivery line. Make- Kiloskar/ CGL/CRI
Two coats Al. painting of whole installation with metal primer( Red Lead) . Make- Asian Paints/ Nerolac/Berger
Design Planning & Construction of RCC foundation for self supported chimney including soil investigation work and all other necy works as per directionof EIC
LT panel for A.P.C system with necey cables and accessories from LT panel to Control Panel and all other equipments
UNITECH REFRACTORIES AND ENGINEERING CO
UNIQUE REFRACTORIES AND ENGINEERING INDUSTRIES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .