Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.7 LAdmitted-Finance | ₹13.7 L | L1 | Admitted-Finance |
| 2 | L2₹13.7 L+₹6,953 (0.51%)Admitted-Finance | ₹13.7 L+₹6,953 (0.51%) | L2 | Admitted-Finance |
| 3 | L3₹16.2 L+₹2.6 L (18.7%)Admitted-Finance | ₹16.2 L+₹2.6 L (18.7%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | CENTRE POINT ENGINEERING AND SUPPLIERS L1 | Bilal Electricals L3 | HM PEERZADA ENTERPRISES L2 |
|---|---|---|---|---|---|---|
| 1.00HT Line | ||||||
| 1.01 | SITC of 11KV Isolator Double Break 3-pole 630 Ampere Horizontal Mounting Type Without Earthing Switch ( to be inserted at main Road towards Odina Village and Job including all GI Fixture required to install the isolator on DP Poles structure as per standard including Pad clamps 6 No of size | 1 | Job | 25,000 ₹25,000 Lowest | 30,000 ₹30,000 | 76,900 ₹76,900 |
| 1.02 | SITC of 09 Mtr. Long Pole ( ST-410 SP33) including pit excuavation of 1/6th of pole length | 36 | No's | 18,500 ₹6,66,000 | 19,500 ₹7,02,000 | 17,900 ₹6,44,400 Lowest |
| 1.03 | SITC 0.1 ACSR Conductor (DOG). | 4.5 | Km | 90,000 ₹4,05,000 | 1,50,000 ₹6,75,000 | 71,230 ₹3,20,535 Lowest |
| 1.04 | SITC 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm suitable for 0.1 ACSR | 112 | No's | 199 ₹22,288 Lowest | 250 ₹28,000 | 350 ₹39,200 |
| 1.05 | SITC V -Shaped GI Cross Arms (75X40X6 mm) with top Bracket including Clamps and GI Nuts and Bolts. (Job include cross belting and CI if any required as per site requirement ) | 1,080 | Kgs | 120 ₹1,29,600 | 100 ₹1,08,000 Lowest | 131 ₹1,41,480 |
| 1.06 | SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete | 3 | Set | 500 ₹1,500 Lowest | 500 ₹1,500 Lowest | 999 ₹2,997 |
| 1.07 | SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm | 39 | No's | 1,000 ₹39,000 | 500 ₹19,500 Lowest | 599 ₹23,361 |
| 1.08 | SITC of Red-Oxide for painting of Poles | 36 | Ltr's | 100 ₹3,600 | 200 ₹7,200 | 5 ₹180 Lowest |
| 1.09 | SITC of Aluminium paint for painting of Poles | 36 | Ltr's | 300 ₹10,800 | 200 ₹7,200 Lowest | 499 ₹17,964 |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
14 Aug 2026, 2:00 pmClosed
Executive Engineer ED Sumbal
Office of the Executive Engineer ED Sumbal Near Irrigation Colony Sumbal
Augmentation/segregation of 11 KV feeders to overcome LCP Constraints for various Divisions of KPDCL falling under the jurisdiction of PAO, KPDCL Sopore Under UT Capex 2026-27 ( 11kV feeder for Odina village from Rec stan Odina )
2026_PDD_317186_1
EDSbl 07 of 2026-27
Open Tender
Electrical Works
Turn-key
45 days
Sumbal
as per SBD
6 documents required · 6 mandatory
₹1,000
Executive Engineer ED Sumbal
₹29,000
8 Sept 2026
22 Jul 2026
17 Aug 2026
22 Jul 2026
14 Aug 2026
23 Jul 2026
22 Jul 2026 - 23 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1HT Line | |||||
| 1.01 | SITC of 11KV Isolator Double Break 3-pole 630 Ampere Horizontal Mounting Type Without Earthing Switch ( to be inserted at main Road towards Odina Village and Job including all GI Fixture required to install the isolator on DP Poles structure as per standard including Pad clamps 6 No of size | 1 | Job | 1 | ₹1 |
| 1.02 | SITC of 09 Mtr. Long Pole ( ST-410 SP33) including pit excuavation of 1/6th of pole length | 36 | No's | 1 | ₹36 |
| 1.03 | SITC 0.1 ACSR Conductor (DOG). | 4.5 | Km | 1 | ₹4.5 |
| 1.04 | SITC 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm suitable for 0.1 ACSR | 112 | No's | 1 | ₹112 |
| 1.05 | SITC V -Shaped GI Cross Arms (75X40X6 mm) with top Bracket including Clamps and GI Nuts and Bolts. (Job include cross belting and CI if any required as per site requirement ) | 1,080 | Kgs | 1 | ₹1,080 |
| 1.06 | SITC of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete | 3 | Set | 1 | ₹3 |
| 1.07 | SITC of Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25X3 mm | 39 | No's | 1 | ₹39 |
| 1.08 | SITC of Red-Oxide for painting of Poles | 36 | Ltr's | 1 | ₹36 |
| 1.09 | SITC of Aluminium paint for painting of Poles | 36 | Ltr's | 1 | ₹36 |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.85 MB
SBD07.pdf
Tender Documents • 1.03 MB
Drawings.pdf
Other Document • 5.44 MB
Specifications.pdf
Additional Documents • 3.87 MB
BOQ_1038317.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .