Tender Value
₹9.8 L
EMD Value
₹12,300
Closing Date
13 Jan 2025, 11:00 amClosed
PE EnM Karo OCP
OFFICE OF PE EnM Karo OCP
Making boundary along the sides of the platform, providing arrangements for proper lighting in the periphery, making arrangements for welding works and making shed adjoining to the Road Weighbridge no. 9, at Kargali Railway Siding, under Karo OCP, Bn
2025_CCL_324696_1
P.E. (EnM)/ Karo OCP/ e-tender/ 2024-25/ 83
Open Tender
Electrical and Maintenance Works
Item Rate
7 days
KARO OCP
Please refer Tender documents.
3 documents required · 3 mandatory
₹12,300
30 Jan 2025
2 Jan 2025
14 Jan 2025
2 Jan 2025
13 Jan 2025
3 Jan 2025
2 Jan 2025 - 13 Jan 2025
Amount
Erection of Metalic Pole of above 8 meter and upto 10 meter in cement concrete 1:3:6 (1 cement:3coarse sand:6graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required
Erection of Metalic Pole of above 6.5 meter and upto 8 meter in cement concrete 1:3:6 (1 cement:3coarse sand:6graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc as required
Cutting of 18 nos. of 90 lbs Rail Pole to make into poles of required length (77.4025 x 18 nos. x 2 sides = 2786.49")
Cutting of M.S. Plates
Supply and fixing of 32 mm dia 2 metre long G.I. pipe, (medium class) bracket for mounting of fluoroscent H.P.M.V./ H.P.S.V. L.E.D. Light fittings on pole including binding the pipe to the required shape, 2 nos. 40 mm x 3 mm flat iron clamps with nuts and bolts and washers painting the flat iron with primer and finish paint etc. as reqd (for hanging departmental L.E.D. lights)
Supplying and drawing 2 x 4 sq. mm. size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (for Service Wire)
Supply, providing and applying of Red Oxide Primer for painting of poles with all accessories, including labour cost. (Per pole requirement: 2.5 litre). Thus, for 18 nos. of poles: 45 litre
Supply, providing and applying of Aluminium paint and double coat painting with all accessories, including labour cost. (Per pole requirement: 3.2 litre). Thus, for 18 nos. of poles: 57.6 litre
Earth work in surface excavation not exceeding 30 cm in depth but exceeding1.5 min width as well as10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto1.5 m,as directed by Engineer-in-Charge:
Surface dressing of the ground including removing vegetation and in equalities not exceeding15 cm deep and disposal of rubbish, lead upto 50 m and lift up to 1.5 m.
Filling available excavated earth (excluding rock) in trenches, plinth. sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50m and for all lift
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:3:6 (1 cement : 3 coarse sand (zone III) derived from natural sources : 6 graded stone aggregate 40mm nominal size)
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.80 mm thick with zinc coating not less than 275 gm/m²
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board,415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double doo
Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25A
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of "Single Pole & Neutral" poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and fixing following capacity TP&N disconnector fuseswitch unit inside the existing panel boardwith ISI marked HRCfusesincludingdrilling holes in cubicle panel, making connections, etc. as required. 32A TP&N
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing metal box of 150 mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 amps socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Providing and fixing 400 A capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.
Supplying and erection of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required.
Supplying and drawing 3 x 6 sq. mm. size of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. (for Service Wire)
Total impact of GST for the purpose of CTC
RAJA ELECTRICAL WORKS (BID ID -1114780)
M/S UNIVERSAL TRADERS (BID ID -1114773)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .