Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹29.1 L+₹1.1 L (4.10%)Rejected-Finance MIG FLAT 6D POCKET I SECTOR 10 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹32.0 L+₹4.1 L (14.5%)Rejected-Finance 26 740 35 KESARI HOUSE NEAR RICO INDUSTRIAL AREA DEVIPURA SIKAR RAJASTHAN 332 001 | SIKAR | SIKAR | RAJASTHAN | 332001 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹37.5 L+₹9.5 L (34.0%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical 37 222 BUNDU KATRA AGRA UP | AGRA | UP | - | Rejected-Technical Rejected due to non-compliance of eligibility criteria |
| Sl No | Description | Qty | Unit | Elmek Engineers L2 | SHRI HARI CONSTRUCTION L4 | AUTOMATION AND SWITCHGEAR PANELS L1 | HUMERS INFRATECH L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed. | 136 | Cum | 100 ₹13,600 Lowest | 200 ₹27,200 | 150 ₹20,400 | 180 ₹24,480 |
| 2.00 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed. | 93 | Cum | 35 ₹3,255 Lowest | 50 ₹4,650 | 70 ₹6,510 | 120 ₹11,160 |
| 3.00 | Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed. | 43 | Cum | 35 ₹1,505 Lowest | 50 ₹2,150 | 60 ₹2,580 | 150 ₹6,450 |
| 4.00 | Supply & spread unwashed dry river sand for sand cushioning for covering the under ground cable in trenchescomplete all as specified and directed.
Note :- Punning thickness shall be measured. | 27 | CUM | 500 ₹13,500 Lowest | 850 ₹22,950 | 500 ₹13,500 Lowest | 2,200 ₹59,400 |
| 5.00 | M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified and directed. | 2.9 | Per 1000 Nos | 5,000 ₹14,500 | 3,000 ₹8,700 Lowest | 6,000 ₹17,400 | 9,000 ₹26,100 |
| 6.00 | Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 volts grade , suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including road bore with GI pipe upto 50 RM jointing & testing of cross sectional area 120 sqmm 3 core complete all as specified and dircted. | 375 | RM | 1,310 ₹4,91,250 | 1,400 ₹5,25,000 | 1,100 ₹4,12,500 Lowest | 1,350 ₹5,06,250 |
| 7.00 | M&L for cable end termination, jointing kit, HT 11 KV grade,heat shrinkable, indoor type complete with jointing material suitable for HT XLPE cable 120 sqmm x 3 core complete all as specified and directed . | 8 | EACH | 5,000 ₹40,000 | 4,000 ₹32,000 | 12,000 ₹96,000 | 3,200 ₹25,600 Lowest |
| 8.00 | Supply, install, erection, commisioning and testing HT 11 KV.outdoor extensible type , cubical , 4-way (RRL-2LBS+2VCB)), Gas (SF6) Insulated RMU including comprising with 2 Nos x LBS (Load break switches) and 2 No x VCB of rating of each 630 Amp 3 phase 50 cycles 12 KV, 20kA/ 3 Sec Ambient temperature - (-5 degree Celsius to +55 degree Celsius), Manual Operated SF6-Breaker having copper bus bar 1000Amp , cast resin tank with , LV Current transformer compatible with self powered relay & 11 KV regin cast PTs (one set of 3 Nos) with saperate metering chamber complete including comprising of following all as specified and directed:-
Each Load break switch will include the following:
(i) SF6 three position switches with position ON-OFF-EARTH
(ii) Breaker shall be motirized with 110V DC control voltage to operate two position double spring mechanism with provision of manual operation.
(ii) Mechanical indicators for position ON-OFF-EARTH.
(iii) Mimic diagram at the front facia of RMU
(iv) Socket for Capacitive Voltage Indicator ( "Live Cable “ Indicating LEDs energized through Capacitive Voltage Dividers.)
(v) Padlocking facility
(vi) Cable box suitable for cable termination of 1 No. 3 core 120 sq.mm. XLPE cable.
Each Circuit Breaker will include the following:
(i) Manually operated SF6 insulated VCB 3 pahse 630A 12 KV rating circuit breaker having resin cast tank and Earthing Switch with full making capacity with position ON-OFF
(ii) Manual Line disconnector with three position switches ON-OFF-EARTH
(iii) Anti reflex operating handle.
(iv) Auxiliary switches 6 NO + 6NC with wiring
(v) Shunt Trip coil (230V AC) for external trip signal. | 2 | EACH | 11,50,000 ₹23,00,000 | 15,50,000 ₹31,00,000 | 11,00,000 ₹22,00,000 Lowest | 12,50,000 ₹25,00,000 |
| 8.10(vi) Self powered O/C + E/F relay protection 3 phase definite time over current and short-circuit protection with variable tripping times (ANSI 50/51), 3 phase over current protection with selectable inverse time characteristics and definite time short-circuit current element (ANSI 50/51), definiteMake WIB Woodward AVK SEG/equivelent (vii) Power Pack battery should be minimum 30 minute backup capacity with battery charge . (viii) Live Cable “ Indicating LEDs energized thru Capacitive Voltage Dividers (ix) Cable box suitable for cable termination of 1 No. 3 core 120 sq.mm. XLPE cable. Accessories with each RMU includes : (i) Operating handle - 1 No (ii) Right angled Cable boots- 4x sets Make Siemens /equivelent. (iii) Capacitor Voltage indicator type HR-ST - 4 Nos. Make Hortsmann. Saperate Metering chamber includes :- (i) 3 Phase, 3 Limb draw out type bus connected Epoxy potential transformer, ratio 11KV/√3/110V/√3 AC accuracy 1.0, burdon 50 VA - 01 (ii) Digital type voltmer -1No (iii) RYB indication - 1set Note :-(i) RMU shall be outdoor PCC platform mounted. (ii) Civil work PCC platform ) for RMU is deemed to be included in the unit rate quoted by contractor. The PCC platform details as per the manufacturer's instructions. | |||||||
| 9.00 | M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.25 metres below ground level with the top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including galvanised iron or steel earth strip lead 32X6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel earthing wire protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth strip on pole/ test point. Watering pipe shall be 20mm bore GI medium grade including excavation and earth work in any type of soil, PCC pit and RCC cover complete all as specified and directed. | 6 | EACH | 6,000 ₹36,000 | 4,500 ₹27,000 Lowest | 5,000 ₹30,000 | 7,500 ₹45,000 |
Tender Value
₹36.6 L
EMD Value
₹73,200
Closing Date
29 Sept 2025, 6:00 pmClosed
CWE Mathura
HQ CWE Mathura
As per tender documents
2025_MES_706276_2
CWE/MTR/BPR of 2025-26
Open Tender
Miscellaneous Works
Item Rate
180 days
GE Bharatpur
As per NIT documents
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹73,200
Yes
26 Nov 2025
8 Sept 2025
6 Oct 2025
8 Sept 2025
29 Sept 2025
15 Sept 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .