Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC D 35 1ST FLOOR CLOCK TOWER HARI NAGAR NEW DELHI 110064 | WEST | DELHI | 110064 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.0 L+₹3.1 L (18.1%)Rejected-Finance 43 VIMAL ENCLAVE CHAMRAULI MODE SHAMSHABAD ROAD AGRA UP 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹20.0 L+₹3.1 L (18.3%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹21.3 L+₹4.4 L (26.2%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹23.4 L+₹6.5 L (38.3%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
6 Nov 2024, 6:00 pmClosed
GE (East) Agra
Garrison Engineer (East) Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt-282001
REPAIR/MAINT OF LED FITTINGS AND FIXTURES, MODULAR SWITCH, SOCKET AND CONNECTED WIRING OF FMC, GWL ROAD, MANEKSHAW, KB LINE UNDER GE (E) AGRA
2024_MES_679697_1
9636/E8
Open Tender
Electrical and Maintenance Works
Item Rate
210 days
AGRA (UP)
Please refer tender documents
10 documents required · 10 mandatory
₹500
GE (East) Agra
₹50,000
Yes
24 Dec 2024
16 Oct 2024
13 Nov 2024
16 Oct 2024
6 Nov 2024
30 Oct 2024
Amount
Taking down carefully existing unserviceable copper / aluminum point wiring of any description & in any position with and ncluding taking out existing unserviceable conduits or battens of any description with sunken boxes/junction boxes and all fitting, accessories & fixtures such as switches, ceiling roses, pendants, regulators, socket, light fittings, lamp holders etc but excluding tube light fittings and making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in including PVC concealed conduit not less than 20 mm dia with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC conduit and GI modular sunken box of suitable module as per site requirement not less than 1.6mm thick and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Note:- Conduit shall be fixed on surface of roof with necessary saddles where concealing of conduit is not feasible at no extra cost for the following :- (a) One light /fan point controlled by one switch
(b) One 5 pin socket outlet 5 Amps on same board complete all as specified and directed.
(c) One 5 pin socket outlet 5 Amps on independent board complete all as specified and directed.
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
(e) One light point controlled by two 2 - w a y s w i t c h e s , with cables 1.5 sq. mm size complete all as specified and directed.
All as per item No 2.00 here in before but with cable size 4 Sq mm for one 5 pin 15/16 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 4 sqmmcomplete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in existing PVC conduit and FRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for MS modular sunken box of suitable module as per site requirement not less than 1.6mm thick and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles for the following :- (a) One light /fan point controlled by one switch
(b) One 5 pin socket outlet 5 Amps on same board complete all as specified and directed.
(c) One 5 pin socket outlet 5 Amps on independent board complete all as specified and directed.
(d) One bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed.
All as per item No 4.00 here in before but with cable size 4 Sq mm for one 5 pin 15/16 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 4 sqmm complete all as specified and directed.
M&L point wiring with 1.5 sqmm multi stranded copper conductor 1100 volts. grade FRLSH PVC insulated unsheathed cable with proper colour coding drawn in including suitable size of PVC casing caping with all accessories and FRLSH PVC insulated 1.5 Sqmm multi standard sheathed copper wire for continues earth, including cutting and chasing of wall surface for laying PVC casing caping and MS modular sunken box with suitable module as per site requirement not less than 1.6mm thick and connecting earth and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles. Note :PVC Casing capaing shall be fixed on surface of roof with necessary fittings at no extra cost for the following :- (a) One light /fan point controlled by one switch
(b) One 5 pin socket outlet 5 Amps on same board complete all as specified and directed.
(c) One 5 pin socket outlet 5 Amps on independent board complete all as specified and directed.
All as per item No 6.00 here in before but with cable size 4 Sq mm for one 5 pin 15/16 Amps socket out let on independent board and multistrand insulated copper earth continuity conductor of size 4 sqmm complete all as specified and directed.
Supply and fixing modular switch piano single pole, one way 6 Amps 1 module, complete all as specified and directed.
Supply and fixing modular switch piano single pole, two way 6 Amps 1 module, complete all as specified and directed.
Supply and fixing modular switch piano flush type 16 Amps single pole one way, one module, complete all as specified and directed.
Supply and fixing modular socket outlet 2/3 pin 6 Amps combined 2 module, complete all as specified and directed.
Supply and fixing modular socket multipurpose 3 pin 6/16 Amps combined 2 module, complete all as specified and directed.
Supply and fixing modular step type, 2 module electronic fan regulator heavy duty 120watts 240 volts. , complete all as specified and directed.
Supply and fixing Modular Bell push 6A 1 module pole, one way, complete all as specified and directed.
Supply and fixing call bell, Ding dong type, 230 volts AC single pole complete all as specified and directed.
Supplying & fixing for ceiling rose PVC Polycarbonate isolated body 62.5 x 25 mm, three terminals, complete all as specified & directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 1 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 2 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 3 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 4 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 6 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 8 module for mounting switch and sockets complete all as specified and directed.
Supply and fixing modular cover plate with metal frame (inner and outer) 2x6 (12) module for mounting switch and sockets complete all as specified and directed.
Supply and fixing blank spacer plate for single module complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20W) luminaire lumen >2000 lm, system efficiency of >120 lumens /W, with Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
S&F in repair Inverter LED batten with square profile and polycarbonate channel. Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <20W (4 feet 20W) luminaire complete all as specified and directed.
S&F in repair LED batten Tube Light surface / wall mounted with specially designed powder coated aluminum housing, high optically efficient polycarbonate diffuser, in built electronic driver duly wired upto terminal block, power consumption <10W (2 feet 10 W) luminaire lumen >1000 lm, system efficiency of >100 lumens /W, with LED binning as per ANSI Bin C78.377A, photo biological safety report as per IEC624718 & electrical insulation class I, Ingress protection IP 20, colour rendering index CRI>80, temp range 0 to 450C, driver efficency>85%, power factor>0.9, THD <20% as per IEC 61000-3-2, colour temp -6500K, surge protection 2.5 KV, 50000 burning hrs (min) as per L70 criteria, two stages isolated constant current operated driver with range 150-270V AC and seafty extra low voltage safe level <60V DC as per IEC standard with LM70 & LM80 certification complete all as specified and directed.
Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing in replacement LED building security light fitting 35 Watt 230 V AC out-door type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection, fixed to pole or wall of building with and including suitable Bracket made out of 25 mm dia GI light grade pipe, 1.00 m long bent to shape by cutting & welding as required & directed and fixed with two Nos of FI clamps 35x6 mm to be tightened with suitable size of bolts, nut and washers and including painted with two coat of aluminium paint over a coat of red oxide primer, and including connecting the fitting to electric source with & including twin twisted copper flexible wire of size 0.75 sqmm three core with suitable size flexible PVC conduit including all accessories and fixing arrangements for fixing the light fitting and writing the date of fixing on security light with permt marker complete all as specified and directed. Note:-The period of defects liability shall be 02 Years from the date of installation of security light.
Dismantling, taking down exisitng ceiling fan and re-fixing & connecting up including provision of cable from ceiling rose or connector to fan, complete all as specified and directed.
M&L for sub main wiring using two 4 x 10 sqmm single core PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of dia not less than 32 mm with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 10 Sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. (NOTE : Four run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
M&L in replacement for sub main wiring using two 2x6 sqmm single core PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) as required dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x 6 sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
M&L in replacement for sub main wiring using two 2x4 sqmm single core PVC insulated, unsheathed stranded copper conductor cable of voltage rating upto and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) as required dia with standard accessories along-with one run of PVC(green colour) insulated , unsheathed, stranded copper conductor of size 1x 4 sqmm as earth continuity conductor connected to earth dolly complete all as specified and directed. (NOTE : Two run of single core PVC cable with one run of earth conductor and conduit /batten shall be measured as one unit.)
Supply & fix in repair of sheet metal enclosure Vertical TPN DB 4 Way double door, Suitable for Flush Mounting and Surface Mounting, With 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management, fully insulated busbar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Prefitted masking sheet, Reversible Door for IP 54 DB's, With provision for 250 Amp MCCB as incomer and SP/TP MCB's as outgoing incl cutting/chasing of wall and make in good to the disturbed surface complete all as specified and as directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. TPN 415 volts 6 way with IP-43 protection double door complete with appropriate size bus bar and neutral link, fixed flush in wall including chases wall for fixing DB & taking down and making good distributed wall surfaces to match with existing complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 8 way with IP-54 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply & fix in repair sheet metal enclosure MCB distribution board. Single pole & neutral 240 volts 4 way with IP-54 protection double door complete with appropriate size bus bar and neutral link complete all as specified and directed.
Supply and fixing in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amp, complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole, 160 Amps, 50 Hz, Icu=36 KA at 415 volts with thermal magnetic alongwith adjustable magnetic protection for current setting Icu=Ics = 100% with adjustable over load setting (minimum 70% to 100%) value from 10 to 15 times of related capacity standard complete all as specified and directed.
Supply and fixing in repair MCB TPN 100 Amps, 415V 10KA 'C' curve and current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB SP 6 to 32 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing in repair MCB SPN 40 to 63 Amp ('C' curve) having short circuit rating 10KA, 240 volts complete with connection testing and commissioning complete all as specified and directed.
M&L in replacement for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burried directly in ground vertically to a depth not less than 2.25 M below normal ground level ) with top edge of the plate not less than 1.50 M below normal ground level , connected to and including galvanized steel wire 4mm dia as earth lead soldered and riveted to earth plate by means of nuts, bolts, check nuts & washers, of galvanized iron or steel with connected to test point and testing on completion including 15mm GI light grade pipe for earth lead protection from earth point to earth plate, including provn adequate quantity of charcoal dust mixed with 35 % common salt to a packed thickness of not less than 15 cm in alternate layers of charcoal and salt on all sides of earth plate with 20mm bore medium grade GI Pipe for watering,GI check nut, funnel and wire mesh with and including all necessary excavation & earth work in soft/loose soil, returning filling in, removal of surplus soil to a distance 50 metre,,PCC 1:3:6 type C-1 as in earth pit, 40 mm thick RCC cover using cement concrete 1:2:4 type B-1 reinforced with & including 8 mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 and as directed. NOTES:-(i) On testing, after completion of Job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chas-es or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated sit-uation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
Taking down, refixing and connecting electric meters 10-60 amps alongwith CIU & STTD complete as specified and direced.
Supply, fixing and connecting in repair for Electric circuits for size of 1.0 sqmm copper FRLS wire for inverter in existing conduit/casing caping complete all as specified & directed.
S S TRADERS (BID ID -3158679)
M/s Tomar Builders (BID ID -3159215)
Bhakti c (BID ID -3158411)
M/S SHRINATH CONTRACTION (BID ID -3158989)
SIYA ASSOCIATES (BID ID -3158005)
3Krishna Enterprises (BID ID -3159182)
VARDMAN ENTERPRISES (BID ID -3158445)
sumesh furniture (BID ID -3158752)
Mahendra Enterprises (BID ID -3158839)
rohan traders (BID ID -3159099)
M/S OM Enterprises (BID ID -3158951)
M/s SCHOLASTIC ENTERPRISES (BID ID -3158994)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .