Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹42.1 L+₹2.6 L (6.52%)Rejected-Finance GURDASPUR ROAD OPP WAREHOUSE PATHANKOT 145 001 PB | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹44.1 L+₹4.5 L (11.5%)Rejected-Finance KRISHNA SOCIETY OPP TODI XRAY AND DIAG CENTRE MAKUM ROAD TINSUKIA ASSAM 786125 | TINSUKIA | ASSAM | 786125 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹46.4 L+₹6.8 L (17.2%)Rejected-Finance NEAR OLD CCS JUNGLIGHAT SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹46.7 L+₹7.1 L (18.0%)Rejected-Finance 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹43.3 L
EMD Value
₹86,600
Closing Date
27 Jan 2023, 6:00 pmClosed
Garrison Engineer Haddo
GARRISON ENGINEER HADDO Military Engineer Services Haddo Post Port Blair Andaman and Nicobar 744102
ADDITION / ALTERATION AND REPAIR TO FIRE FIGHTING PIPELINE AND CONNECTED ITEMS AT CG JETTY UNDER GE HADDO, PORT BLAIR
2023_MES_573726_1
8714/GE/H/PB
Open Tender
Civil Works
Item Rate
180 days
GE Haddo Port Blair
Class D and Category a(ii) / c(vi)
9 documents required · 9 mandatory
₹500
GE Haddo
₹86,600
Yes
2 Mar 2023
7 Jan 2023
30 Jan 2023
7 Jan 2023
27 Jan 2023
21 Jan 2023
9 Jan 2023 - 16 Jan 2023
Amount
Supplying, installation, testing, perfect aligning and proper leveling and commissioning of fire service main pump of TAC (Tariff advisory committee) approved have to discharge capacity of 4560 LPM at head of 90 mtr. Horizontal centrifugal type multistage pump of horizontal split casing with bronze impeller , cast steel casing body, and stainless steel shaft, shaft sleeves of stainless steel as per IS standards ,directly coupled to water cooled turbo charged diesel engine complete with self starter , battery, diesel storage tank capable to store 8 hours full load diesel requirement, radiator with blower fan ,pipe coupling for engine cooling system, corrosion inhibitor coolant pipe element filters for fuel and oil shut off coil with safety for OP/HWT/OVERSPEED , dry type air cleaner residential silencer , stainless steel exhaust flexible bellows , fuel injection pump, battery charging alternator ,exhaust pipe made out CTIC “c” class MS pipe, Engine & pump and mounted on common MS Channel/Common Base plate and fixed with suitable bolts & antivibrating pads, grouted in PCC foundation/platform inclusive of all accessories complete in all respect, with & incluing the following complete all as specified and directed: i) CI/Brass Foot Valve along with strainer (Make- Kirlosker/Venus/Audco) - 1 Nos Suitabe for Suction of Pump ii) Flanged CI Sluice valve - 1 Nos Suitable of Deliverry of Pump, iii) Flange CI NRV - 1 Nos, Suitable for Delivery of Pump iv) MS ERW Medium Grade Suction pipes of Dia as Specified by Manufactures to a Length Not More than 9 Meters v) MS ERW Medium Grade Delivery pipes of Dia as Specified by Manufactures to a Length Not More than 6 Meters v) Burden type pressure gauge on delivery of Pump set. vi) Interconnection of Delivery mains Vii) 25 mm bore GI Pipe line for Priming viii) 25 mm bore Gun Metal Gate Valve (Priming Valve) - 1 Nos viii) PCC Foudnation Make - Kirloskar, Mather & Platt/Grundfos & Make of Diesel Engine –CUMMIN/Kirloskar (For Ground Hydrant System) NOTE : 06 hours continuous testing of diesel driven pump will be carried out by IEM. The cost of testing is deemed to be included in the quoted rate.
Supplying, installing, testing, perfect aligning and commissioning of fire service main pump, multistage, of TAC (tariff advisory committee) approved having suction and delivery flange, capable to deliver discharge of 4560 LPM (liters/min) at 90mtr head of horizontal centrifugal type multistage pump of horizontal split casing cast steel with bronze impeller ,wearing ring of bronze/steel , shaft stainless steel, shaft sleeves of stainless steel as per IS- 12469 :1988 standards, directly coupled to totally enclosed fan cooled (TEFC) squirrel cage A.C induction motor of suitable capacity to operate on 3ph.440v 50cyc. A.C. with ‘B’ class insulation and both pump and motor are to be erected on common M.S. base plate and required size M.S channel suitable rigid foundation, nut bolts washer, coupling guards, and antivibration rubber pads, with & incluing the following complete all as specified and directed: i) CI/Brass Foot Valve along with strainer (Make- Kirlosker/Venus/Audco) - 1 Nos Suitabe for Suction of Pump ii) Flanged CI Sluice valve - 1 Nos Suitable of Deliverry of Pump, iii) Flange CI NRV - 1 Nos, Suitable for Delivery of Pump iv) MS ERW Medium Grade Suction pipes of Dia as Specified by Manufactures to a Length Not More than 9 Meters v) MS ERW Medium Grade Delivery pipes of Dia as Specified by Manufactures to a Length Not More than 6 Meters v) Burden type pressure gauge on delivery of Pump set. vi) Interconnection of Delivery mains Vii) 25 mm bore GI Pipe line for Priming viii) 25 mm bore Gun Metal Gate Valve (Priming Valve) - 1 Nos viii) PCC Founation Make :-Kirloskar/ KSB /Mather & Platt/Grundfos (For Ground Hydrant System). NOTE : 06 hours continuous testing of electric driven fire pump will be carried out by IEM. The cost of testing is deemed to be included in the quoted rate.
Supply and lay MS ERW pipe of size 250mm dia, conforming to IS : 1239-1982 ISI marked , including all fabrication fittings and joints and laid in ground fixed on wall /celling with heavy duty ‘U’ bolts on MS channels, brackets with fasteners all as directed and applying 2 coats of synthetic enamel paint over a coat of zinc dichromate primer ,including testing at .complete all as specified and directed.
Supply and lay MS ERW pipe of size 150 mm dia, conforming to IS : 1239-1982 ISI marked , including all fabrication fittings and joints and laid in ground fixed on wall /celling with heavy duty ‘U’ bolts on MS channels, brackets with fasteners all as directed and applying 2 coats of synthetic enamel paint over a coat of zinc dichromate primer, including testing at .complete all as specified and directed.
Supply and fix 200mm bore hand operated butterfly valve of pressure not less than 15 Kg / Sqcm with complete set complete all as specified and directed. Make : Kirloskar / AUDCO / L&T / Upadhyay / Normax
Supplying, installing, testing perfect aligning and proper leveling and commissioning of jockey pump horizontal end suction centrifugal type, commissioning of jockey pump horizontal end suction centrifugal type, conforming to 12469:1988 of 180 LPM at 90 mtr Head with bronze impeller, bronze working parts, heavy duty stainless steel shaft and directly coupled to suitable capacity motor , ‘H’ class insulation, squirrel cage induction motor working on 3 ph, 415 volts , A.C. both pump & motor are to be mounted on common base plate along with suitable rigid foundation , nut bolts, with coupling guards and antivibration rubber pads in an approved manner with accessories complete in all respect, and including the following complete all as specified and directed: i) CI/Brass Foot Valve along with strainer (Make- Kirlosker/Venus) - 1 Nos Suitabe for Suction of Pump ii) Flanged CI Sluice valve - 1 Nos Suitable of Deliverry of Pump, iii) Flange CI NRV - 1 Nos, Suitable for Delivery of Pump iv) MS ERW medium grade Suction pipes of Dia as Specified by Manufactures to a Length Not More than 9 Meters v) MS ERW medium grad Delivery pipes of Dia as Specified by Manufactures to a Length Not More than 6 Meters v) Burden type pressure gauge on delivery of Pump set. vi) Interconnection of Delivery mains Vii) 25 mm bore GI Pipe line for Priming viii) 25 mm bore Gun Metal Gate Valve (Priming Valve) - 1 Nos viii) PCC Founation Make :-Kirloskar/ KSB /Mather & Platt/Grundfos (For Wet Riser System). NOTE : 06 hours continuous testing of electric driven fire pump will be carried out by IEM. The cost of testing is deemed to be included in the quoted rate.
Supply and fix sluice valve, class PN-1.6 flanged and drilled at both ends confirming to IS:14846 with ISI mak, having stainless steel spindle and gun metal rings including wheel for operation all as specified including all joints with rubber gasket and jointing materials, bolts, nuts, washers etc with the following sizes complete all as specified and as directed.Note : cost includes the suitable GI nuts and bolts.
200 mm bore
150 mm bore
Supply installation testing commissioning of ISI marked pressure switches of range 2 kg/cm2 to 10 kg/cm2 for pump set complete
Supply and Fix sheet steel enclosure of fully automatic Star delta Starter of capacity 150 HP, over load relay range of 80 to 140 amps, operated at 415 V AC supply, with D range air break contactor ,electronic motor protection relay with built-in feature having pause of 0.30 sec for motor protcion against single phasing, electronic star delta timer,suitable 3 pole MCCB incomer of rapturing capacity 10-25KA and housing should be IP 54 protected complete all as specified and as directed by Engr-In-Charge. Make : C&S / L&T / ABB / SIEMENS / Havells
Supply, Install, commisioning and testing of mono block pump set , centrifugal ,electrically driven, appropriate capacity of 3 phase induction motor with CI casing , bronze impeller and stainless steel shaft mounted on heavy duty bearings with meachanical seals suitable for continous operation at 415 volts , 3 phase , 50 Hz supply with discharge 5.7 LPS , at head 12 mtr including necessary PCC foundation complete all as specified by OEM and supply,fix and laying 2m length of LT cable armoured 1100 Volt grade with copper stranded conductor 3 core of suitable size from DOL starter to motor including cable glands,lugs,thimble etc and connection complete and as directed. MAKE : Kirloskar / Crompton / Jyoti / Beacon / KSB / GRUNDFOS
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 240 sq mm 3.5 core complete all as specified and directed.
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 185 to 240sqmm,Indoor type complete all as specified and directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded ,armoured electric power cables (heavy duty) 1100 Volts grade with single core of 50 Sqmm for Main fire pump complete all as specified and as directed
M&L for taking down of following items from CG Jetty sea water pump house and shifting to MES store yard all as specified and as directed by Engineer -In- Charge (a) Electrical droven 125 HP centrifugal pump-01 No. (b) Diesel driven 125 HP pump-01 No. (c) Disel driven rotary screw type air copmressor cap of 400cfm at 7 Kg/sqcm-01 No. (d) Electric driven rotary screw type air compressor cap of 400cfm at 7 Kg/sqcm-01 No. (f) 3 HP monoblock pump- 01 No Note :1. The contractor should visit the CG jetty pump house before Quoting the Tender. 2. The Required Tools/Vehicles and Plants should be arranged by Contractor 3. Required Cranes for lifting the above said items and Transportation Vehicles for shift the old items to MES Store yard should be arranged by Contractor including labour. 4. The Quoted rates deemed to be include all the Above notes 1,2 & 3
Supply and Fixing in replace of Out door LT Panel / LT Pillar Box of required size including takiung down old LT panel with following specifications. Fabrication Details : CPRI approved Main frame 3.0mm thick CRCA sheet, partition sheets / covers / doors of 3.0 mm thick CRCA sheet, gland plates 3.0 mm thick MS sheet (undrilled), base frame on ICMS channel with provision of incoming and outgoing cable entry at the bottom for outdoor installation, free standing floor mounted with degree of protection IP 65 and locking arrangements. Bus bar details : Material shall be alluminum bus bar, sleeving heat shrinkable type, with bus bar sizes for phase 50mmx12mm aluminium Flat, neutral 50x12mm aluminium flat and bus bar support of epoxy type. Painting Detais : Pillar box shall be powder coated and painted with two coats of synthetic enamel spray paint over a coat of redoxide primer.
Accessories for Pillar Box : 0-500V Digital voltmeter - 01 No and 0-630V Digital Ammeter - 01 No(0-500A),(Flush type) and Indication Lamps (LED) - 03 No. make: L&T /Binay /Elmeasure (a) Incomer:- 400A 4 pole , Change over switch -1no. (b) Outgoing:-(i) 250A,4 pole,MCCB, 35kA -3 nos. (c) 125A,3 pole,MCCB, 35kA - 4 nos. (d) 5 HP DOL starter-02 Nos (e) 30 HP FASD starter-01 No (f) 50 HP FASD starter-01 No Note: Quoted rate is deemed to be includes cost of MCCBs, Volt meter, Ammeter, Idiction lamps, Change over switches and connected wiring with necessary spreader links, lugs,glands and connecting of cables complete all as specified as per site conditions and as directed by Engineer-in-Charge.
Supply and laying in trenches or in cable ducts HDPE DWC pipe of size 110mm(OD)x95mm(ID) alongwith connected accessories like couplers,bends,end caps etc for LT/HT cable protection complete all as specified and as directed.
M & L Lifting RCC cover slabs of size 2 to 4 meters long, 1 to 1.5 meter width and upto 300mm thick and about 2 to 4 tons in weight lying on jetty by cutting /chipping the clearance groove all around ,keeping aside using a crane for layiing of new LT cables/water pipe line including removing of old water pipes of any type and any size and making good surface with PCC 1:2:4 complete all as specified and as directed. Note : (a) two or three slabs shall be taken out/removed as per site condition for laying the new water pipe line in the span of 4 to 5 meters, as per site requirement extra slabs if required to remove it will be also measured separately (b) Cost of T & P required for the work shall be included in the quoted rate. (c) Site will be available in a restricted manner and prior approval shall be obtained before work (d) Contractor is liable for any damage caused to existing services or structtures during the execution of work.
Supply and fix in replace old of fire yard hydrant stand post 80mm dia MS flange type of 1.50m height complete all as specified and as directed
Supply and fixing in replace of old Gun metal ,single outlet type fire hydrant landing valve, type B ISI marked of size 63mm dia internal flanged type complete with brass spindle cast iron wheel, gasket, nut bolts for mounting in flanged MS pipes and instaneous coupling ISI marked, confirming minimum operating pressure 7 Kg/cm2 complete all as specified and directed. MAKE : Zoloto / Safex / Nitin / Flame Guard Indus / Ceasfire
BABBAR ENGINEERS
ss enterprises
SKV Engineering
Prasur Electricals & Engineering Co.
CHANDER SEKER ENTERPRISE
V KARTHICK
Bismi Builders & Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .