| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.4 LAccepted-AOC HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | L1 | Accepted-AOC Since L1 bidder | |
| 2 | L2₹76.9 L+₹1.1 L (1.42%)Rejected-Finance SHOP NO 2 NEW MARKET CHOWK HUSSAINPURA GURDASPUR | GURDASPUR | PUNJAB | 143505 | L2 | Rejected-Finance Since not L1 bidder | |
| 3 | L3₹85.9 L+₹10.1 L (13.3%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L3 | Rejected-Finance Since not L1 bidder | |
| 4 | L4₹1.0 Cr+₹25.2 L (33.3%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance Since not L1 bidder |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
21 Oct 2024, 6:00 pmClosed
CWE Amritsar
HQ CWE Amritsar
REPAIR MAINTENANCE AND TESTING OF MRS AND REPAIR MAINT OF TRANSFORMER WITH ALLIED WORKS AT NAMS
2024_MES_671610_1
CWE/ASR-42/2024-25
Open Tender
Civil Works
Item Rate
270 days
GE NAMS
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE NAMS
₹1.8 L
Yes
4 Dec 2024
5 Sept 2024
28 Oct 2024
5 Sept 2024
21 Oct 2024
7 Oct 2024
Amount
Servicing of HT VCB 11KV,630A /800A of Kirloskar or as per existing make alongwith tripping system and testing of vaccum circuit breaker 11KV, 630A/800A , 25KA including taking out Breaker/trolley and carried out the fwg repair/tests made for smooth operation. SM No 652/3145 HV/06 to SM No 652/3158 HV/06, SM No 652/3162-HV/17 to SM No 652/3164-HV/17, SM No 652/3126-HV/09 to SM No 652/3137-HV/09 and SM No 652/3172-HV/17 to SM No 652/3198-HV/17 complete, all as specified and directed. (a) Cleaning and greasing of mechanism- 01 Job (b)Tightning testing of mechanism parts- 01 Job. (c ) Alignment testing and adjustment of mechanism- 01 Job. (d) Operation, testing of trip and close electrical and manual mode- 01 Job. (e) Spring charging testing electrical and manual mode- 01 Job. (f) Cleaning of panel insulater CT &PT unit- 01 Job. (g) Cleaning and tightning of control/wiring CT &PT unit- 01 Job. (h) Cleaning and testing of relay with current injection method- 01 Job. (j) Testing of auxillary relay - 01 Job. (k) Allingment of trolley, checking/greasing of shutter /lock of breaker Note :- (a) The cost of minor spare parts i.e Springs, nut bolts any type, grommets, dust cover, ring of isolator contacts, clips, pin for release prop, 'Y' Phase shround, over ride stop pin , grease and lacker spray etc. unless or otherwise mentioned here-in-after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. Note :- All the maintenace / servicing shall be carried out by Mechanical team of PSPCL and all expenses shall be deemed to be included in quoted rates and nothing extra shall be admissible.
Servicing of HT RTCC Panel/ Capacitor Feeder Panel/ CR Panels / Bus Coupler / Bay marshal box as per existing make alongwith operating mechanism system and carried out the fwg repair for smooth operation complete, all as specified and directed. (a) Cleaning and greasing of mechanism- 01 Job (b)Tightning testing of mechanism parts- 01 Job. (c ) Alignment testing and adjustment of mechanism- 01 Job. (d) Operation, testing of trip and close electrical and manual mode- 01 Job. (e) Control wiring and software updation / repair- 01 Job. (f) Cleaning of Panel and bus bar - 01 Job. (g) Cleaning and tightning of control/wiring AC/ DC- 01 Job. (h) Cleaning and testing of all relay - 01 Job. (j) Testing of RVT & repair of HV side Bushing terminal of RVT- 02 Job (k) Testing of Capacitor Bank. -12Nos Note :- (a) The cost of minor spare parts i.e. grease,all type nut bplts and lacker spray etc. unless or otherwise mentioned here-in-after but essentially required to make the panel serviceable shall be deemed to be included in the quoted rate. (b) All the maintenace / servicing shall be carried out by Mechanical team of PSPCL and all expenses shall be deemed to be included in quoted rates and nothing extra shall be admissible.
Material and labour for Natural river sand for cushioning to underground cable in trench/ in ducts of sub stations/ under power transformer complete, all as specified and directed.
Supply and fixing in replacement of silica gel for Transformers complete, all as specified and directed.
Cleaning, dehydration/ reconditioning of transformer oil different location by dehydration plant including testing as per IS Specification and result not less than 40 KV at site,complete, all as specified and directed.
Supply and fixing in replacement CT unit 300/150/5A, 15 VA 50Hz suitable for 11KV VCB Make Areva/Kirloskar/CG & other equivalent makes complete, all as specified and directed.
Supply and fixing in replacement CT unit 100/50/5A, 15 VA 50Hz suitable for 11KV VCB Make Areva/Kirloskar/CG & other equivalent makes complete, all as specified and directed.
Supply and fixing in replacement CT unit 600/300/5A, 15 VA 50Hz suitable for 11KV VCB Make Areva/Kirloskar/CG & other equivalent makes complete, all as specified and directed.
Supply and fixing in replacement multifunction relay suitable for 11 KV ,630/800 Amp VCB complete, all as specified and directed.
Supply and fixing in replacement multifunction meter suitable for 11 KV ,630/800 Amp VCB complete, all as specified and directed.
Supply and fixing in replacement master trip relay suitable for 11 KV ,630/800 Amp VCB complete, all as specified and directed.
Supply and fixing in replacement fuse carrier assembly suitable for 11 KV VCB/RVT/CCR Panel complete, all as specified and directed.
Supply and fix in replacement spring charging electric motor 24 V -110V , speed < 2000 RPM suitable for VCB of cap 630/800 Amp with complete accessories as per existing complete, all as specified and directed.
Material and labour for in repair/replacement of AC/DC electric wiring kit as per site requirment complete suitable for Kriloskar made VCB 630 Amp and with male and female scoket 52 Pin type as per existing complete, all as specified and directed.
Supply and fixing in replacement of complete vaccum interrupter bottle (VG-02) -03 Nos suitable of HT 11 KV existing VCB 630/800 Amp capacity. The vacuum bottle should be capable of withstading minimum 100 full short circuit operations as per test duly 1 to 05 of IEC-56 for complete, all as specified and directed.
Supply and fixing in replacement of RET - Transformer Protection multifunction relay/Diffrential relay (RET541AM231AAAA) of CR panel 4/8 MVA Transformer as per existing technical specification/Make or equivlent at 66 KV MRS complete, all as specified and directed.
Supply and fixing in replacement of 72.5 KV PTs Ratio 66 KV /3/110V/3/110V/3 AC 50 HZ all as per existing specification complete, all as specified and directed.
Supply and fixing in replacement flexible copper cable size 06 sqmm two core for connection MCCB to Busbar OR any feeder complete, all as specified and directed.
Material and labour for providing 20mm broken stone aggregate including spreading and levelling complete, all as specified and directed.
Supply and fixing in repalcement of 11KV lightening arrestor explulsion type complete with all fittings, transmission class, discharge capacity 65 KA OR as per existing technical specification and size for one phase complete, all as specified and directed.
Supply and fixing, jointing ,testing in repair end termination jointing kit heat shrinkable out door type ,suitable for HT 11000 volts grade XLPE UG cable of size 240 to 300 sqmm 3 core complete, all as specified and directed.
Supply and fixing , jointing ,testing in repair end termination jointing kit heat shrinkable out door type ,suitable for HT 11000 volts grade XLPE UG cable of size 120 to 185 sqmm 3 core complete all as specified.
Supply and fixing in replacement End termination joint heat shrinkable outdoor type suitable for 3 core 11000 volts grade XLPE UG cable of size 70 to 95 Sq mm complete all as specified and directed.
Supply and fixing, jointing ,testing in repair end termination jointing kit heat shrinkable Indoor type ,suitable for HT 11000 volts grade XLPE UG cable of size 240 to 300 sqmm 3 core complete, all as specified and directed.
Supply and fixing, jointing ,testing in repair end termination jointing kit heat shrinkable Indoor type ,suitable for HT 11000 volts grade XLPE UG cable of size 120 to 185 sqmm 3 core complete, all as specified and directed.
Supply and fixing in replacement End termination joint heat shrinkable Indoor type suitable for 3 core 11000 volts grade XLPE UG cable of size 70 to 95 Sq mm complete, all as specified and directed.
Supply , jointing ,testing in repair for straight through jointing kit heat shrinkable ,suitable for HT 11000 volts grade XLPE UG cable of size 240 to 400 sqmm 3 core complete, all as specified and directed.
Supply and fixing, jointing ,testing in repair for straight through jointing kit heat shrinkable ,suitable for HT 11000 volts grade XLPE UG cable of size 120 to 185 sqmm 3 core complete, all as specified and directed.
Supply and fixing, jointing ,testing in repair for straight through jointing kit heat shrinkable ,suitable for HT 11000 volts grade XLPE UG cable of size 70 to 95 sqmm 3 core complete, all as specified and directed.
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 95 sqmm 3 core, laid in duct / trench/along pole etc including making connection complete, all as specified and directed.
Supply and fixing in replacement of HT underground cable XLPE insulated PVC bedded, galvanised steel strip armoured electric power cables (heavy duty) with stranded aluminium conductor 11000 volts grade cross sectional area 185 sqmm 3 core, laid in duct / trench/along pole etc including making connection complete, all as specified and directed.
Excavation in trenches in soft/loose soil n.exc. 1.5mtr wide and n. exc. 1.5mtr in depth and getting out for laying of cables complete, all as specified and directed.
All as per srl item above above but exceeding 1.5 Mtr and not exceeding 3 mtr deep complete, all as specified and directed.
Returning, filling in, and including spreading, levelling,watering and well ramming in layers not exceeding 25 cm thick complete, all as specified and directed.
Removing excavated material n. exc. 50m and depositing where directed at a level n. exc. 1.5 m above the starting point complete, all as specified and directed.
Material and labour for Sand cushioning to underground cable 8cm before laying the cable and 15cm (punned down to 18 cm) after laying and stretching the cable complete, all as specified and directed.
Supply and laying in replacement for un-reinforced precast concrete cable cover factory made, class HV, type I, flat of size 300mm x 180mm x 40mm complete complete, all as specified and directed.
Material and labour of demolition of old PCC pole and Supply and erect steel tubular swaged poles Momplete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-55 ( 11 mtr long) erecting in position all as specified/shown on drawing complete with two coat of aluminum base paint over a coat of red oxide paint and black and white strip each 30cm long upto 1.5 mtr height from ground and writing pole number with black paint and complete, all as specified and directed. Location :- MAP Sub Stations and TOP -I Power House and Inf Bde Area. Note: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent \tems.
Material and labour for PCC ( 1:2:4) type B1 using 20mm graded stone aggregate for coping pedestal of poles. Including necessary form work fair finished to exposed surface complete, all as specified and directed.
Material and labour for PCC 1:3:6 type C-1 using 20mm graded broken stone aggregate as in mass concrete in foundation of stays and poles complete, all as specified and directed.
Excavates and relaying HT cables loops near the poles / transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves complete, all as specified and directed.
Prunning of trees of over head lines of any voltage by taking proper shutdown & removing the same from site upto a distance of 50 mtr away complete, all as specified and directed.
Material & labour for restrainging ACSR conductor HT/LT providing proper sag all as specified and directed. Note : Upto 5 conductor will be consider as one span only complete, all as specified and directed.
Material and labour for jointing broken/ lying on ground conductor and restrach the same conductor with straching of 3 to 4 span complete with maintaing proper sag complete, all as specified and directed. Note :- Conductor required for jointing broken conductor shall be included in the quoted rate. No extra payment shall be made to the contractor for the same.
Material and labour for replacement of electrical shock treatment chart in Hindi ,english and Punjabi complete with figures and letters complete of size not less than 50 cm x 75 cm OR as per Engr-in-Charge complete, all as specified and directed.
Material and labour for locating the fault in VCB, repair/ replacement of defected items, drying moisture from VCB and common complete bus bar of system and restand the elect supply complete, all as specified and directed. Note :- (i) All tools and plant including blower/ gas cylinder, spray for cleaning bus bar , spray for bus bar insulation , cleaning clothes , emergency lighting arrange in power house for repair work and other equipment will be arranged by the contractor with no extra cost paid to contractor. (ii) One VCB and common complete HT bus bar of different VCB will be catered as on Job (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of Rs 2000/- per complaint / fault will be imposed on the contractor from contractor dues. (iv) Minimun one VCB shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all VCB repair in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor.
Material and labour for locating the fault in Transformer of any capacity , pole mounted/ plinth mounted, laid indoor on ground , repair/ replacement of defected gasket, HT bush , LT bush, replacement of thimble of transformer 100 KVA to 630 KVA , maggering transformer for detecting fault and retapping complete and make the transformer serviceable complete, all as specified and directed. Note :- (i) All tools and plant including magger , ladder and othe equipment will be arranged by the contractor with no extra cost paid to contractor. (ii) One transformer will be catered as on Job (iii) Contractor shall deposit / Procure all the material in advance to avoid any late night fault/ after market hours / non availability of material in market. The elect supply shall be restore within 5 hours from the time of tripping / fault in day or night in the stn, failing this a panelty of Rs 2000/- per complaint / fault will be imposed on the contractor from contractor dues. (iv) Minimun one transformer shall be produce to contractor for restand/ repair for one visit. Contractor will not demand all job in one visit. Visit and Repair charges of electrician and helper are included in the quoted rate. no extra charges paid to contractor. (v) Strip opening of transformer for detecting fault shall be included in the quoted rate. No extra amount shall be paid to the contractor. (vi) Gasket, Copper / Aluminum thimble, HT/ LT Tape for any size of transformer will be included in the quoted rate . No extra amount shall be paid to the contractor for the same. (vii) LT/ HT rod , transformer oil and insulator shall be measured and paid seperately.
Material and labour for disconnecting all the transformer, connection (Indoor/ Outdoor, Plinth/Pole Mounted any type anywhere) and carry transformer to other location (TOP -II Yard) and shifting other transformer to the location of fault under the arrangement of contractor and connecting all the connection and make the light serviceable / functional complete, all as specified and directed. Note :- All tools, plants and vehicle for lifting and disconnection of connection from LT/HT side complete shall be arranged by the contractor and not extra payment shall be paid to the contractor for the same.
Servicing and repair/maint of HV SF6 Circuit Breaker of Capacity 72.5 KV, 31.5 KA 1600 Amp at 66 KV alongwith tripping system and carried out the following repair made for smooth operation complete, all as specified and directed:- (a) Cleaning and greasing of mechanism, Operation, trip and close electrical and manual mode, Spring charging testing electrical and manual mode, Cleaning of panel insulator CT &PT unit, (b) Service will be carried out through PSPCL /Service Engineer of Manfacturer /Authorised Service Engineer only. (c) The cost of minor spare parts i.e nut and bolts, springs, grommets, clips, pin etc essentially required to make the breaker serviceable shall be deemed to be included in the quoted rate. (d) Any other repair such as service and repair for Manual handle operation unit as well as operated spring etc complete rate including in quoted rate. Gas charging of SF6 Gas is Measure & paid saperately.
Material and labour for Servicing, cleaning and greasing of complete operating contacts of 66 KV Sub Stn Grid of 04 Nos power transformer through PSPCL mechanical team including grease and other cleaning material all as required at site complete, all as specified and directed. Note :- Necessary shut down shall be take from PSPCL . (i) Grease for the work shall be included in the quoted rate. No extra payment shall be made to contractor for the same.(ii) Testing of Mechanism of Isolator & setting of moving parts/contacts of Male/female contact of 66KV Isolators work shall be included in the quoted rate.
Material and labour for painting to steel gantry towers & beams for 66 KV outdoor type switch yard complete including all accessories and equipment, support, structrure including preparation of steel surface by scraping and removing old paint, applying a coat of red oxide primer and two coats good quality of aluminium paint as per following:- (a) Approximatly 11 mtr high towers (vertical) - 18 Nos (b) Approximatly 03 Mtr high towers (vertical) - 40 Nos (c ) Approximatly 06 Mtr long (Horizontal) towers - 10 Nos (d) Stand for highly arrested 3 mtr long x 2 mtr width support- 08 Nos (e) Greasing of all contact points in 66 KV switch yard. Note:- All the painting work will be carried out in the 66KV yard after proper shut down from PSPCL and complete, all as specified and directed.
Supply and fixing in repalcement of 66KV lightening surge arrestor discharge current capacity 10 KAP class -II,Rated voltage 120KV including Surge counter with metal oxide gapless type as per existing technical specification and size for one phase complete, all as specified and directed.
Material and labour for filling of SF6 Gas repair of 66 KV HV SF6 breaker as per existing technical specification and size complete with 25 kg Capacity of Gas cylinder including SF6 gas leakage test carried out complete, all as specified and directed.
Supply and fixing in replacment of HRC Fuse cap 4 to 10 Amp suitable for 11 KV VCB DC Circuit complete, all as specified and directed.
Supply and fixing in replacment of RVT 11KV /190V (Residual Voltage Transformer) suitable for 11 KV CR Panel OR as per existing breaker capacity with all fitting/testing complete, all as specified and directed.
Supply and fixing installation, commissioning and testing in replacment of HT outdoor type 66KV protection Current Transformer (CTs ) of Highest voltage system 72.5 KV, 31.5 KA for 1 sec Oil cooled , 50 Hz ,Hermetically sealed, wound Primary type four core live tank type Current Transformer of Ratio 150-75/0.577 -1-1-1A. complete, all as specified and directed. Core 1 : Class - PS Core 2 : Class - 0.2, Burden 25 VA (protection) Core 3 : Class -10P10 Burden 25 VA complete Core 4 : Class 5P15 Burden 25 VA (ref) Complete in all respect to the entire satisfaction of Engr-in-Charge Other specification as per std IE rules and entire satisfaction of the Engr-in-Charge. Note: If required the any other parts/material for fixing/installation of CTs to be arrange by Contractor without any extra cost.
Supply and fixing in replacement of limit switch for 11 KV VCB of KEC Make complete, all as specified and directed.
Supply and fixing in replacement and providing of double space heater 80Watt each including 1.5 Sqmm wiring copper single core and thermostate suitable for 11 KV VCB complete, all as specified and directed.
Supply and fixing in replacement of Volt meter suitable of 11 KV 630 Amp VCB complete, all as specified and directed.
Supply and fixing in replacement of Amp meter DM 3 252 suitable for 11 KV 630 Amp VCB complete, all as specified and directed.
Supply and fixing in replacement of 11KV support insulator suitable for 11KV VCB (VCB make Areva,Kirloskar & CG ), dismantling and mantling of VCB Panel labour charge including, high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete, all as specified and directed.
Supply and fixing in replacement of 11KV spout insulator suitable for 11KV VCB (VCB make Areva,Kirloskar & CG ), dismantling and mantling of VCB Panel labour charge including, high quality 11KV VCB busbar Insulation Material and Nutbolts included in quoted rates complete, all as specified and directed.
Supply and fixing, in replacement, air breather with silica gel as per existing suitable for 6/8 MVA Transformers main oil tank complete, all as specified and directed.
Supply and fixing, in replacement, air breather with silica gel as per existing suitable for 6/8 MVA Transformers oil conservator tank complete, all as specified and directed.
Supply and fixing in replacement of auxalary switch 8 NO + 8NC complete, all as specified and directed.
Supply and fixing in replacement of closing Coil or Triping Coil 30V DC suitable for 11 KV ,630/800 Amp VCB complete, all as specified and directed.
Supply and fixing in replacement of contactor coil 220 Volt DC complete all as per existing complete, all as specified and directed.
Supply and fixing in replacement of PLA relay of 220 volts DC , 04 MO, 04 NC complete, all as specified and directed.
Supply and fixing only heavy duty (Suitable for HT ) Copper thimble of size 120 to 185 sqmm complete, all as specified and directed.
Supply and fixing only heavy duty (Suitable for HT ) Copper thimble of size 240 to 300 sqmm complete, all as specified and directed.
Supply and fixing in replacement three phase over current + earth fault digital relay with high set MC 61 ANX, 4000, Volts 24 - 240 AC /DC type MC 61 ANX 4 NO, Make L&T or equivalent complete with wiring complete, all as specified and directed.
Supply and fixing in replacement of muster trip relay voltage 220 volt DC VAZ type of model No VAZ 413YF67B including complete wiring and make the relay functional complete, all as specified and directed.
Supply and fixing in replacement of Instantneous under voltage relay 110 Volt VAGM type of model No VAGM22AF171G complete, all as specified and directed.
Material and labour for blue silica gel transformer breather 500 gm suitable for transformer of upto capacity 200 KVA complete, all as specified and directed.
Material and labour for blue silica gel transformer breather 1000 gm (1kg) suitable for transformer of upto capacity 630 KVA complete, all as specified and directed.
Supply only HT Insulation tape High quality size minimum 09 mtr long x 2 CM width complete, all as specified and directed.
Material and labour for providing earthing of advance chemical earthing system of copper pipe chemrod 3 mtrs long 50mm dia filled with highly conducting metallic compounds with the permanent sealings at both the ends. Top of the earth electrode shall be compressed to form an extended lead with 2 holes for connecting the strip / wire to the load. To ensure the moisture content and clectrical conductivity each earting pit shall be provided with minimum 2 bags of 25 Kg chemical compound. An arrangement for connection of copper strip 25 x 3 mm to rod to be made with given teminal point through gas welding, including polymer chamber with cover proper cover alongwith locking arrangement and necessary excavation in any type of soil , returning filling in removal of surplus soil complete, all as specified and directed. Note :- Chemical earthing shall only be carried out in presence of company representative and a test report of earthig alongwith result sheet shall be submitted by the company through contractor.
Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white , with numeric, letters in \hindi ,English and including local language and conventional skull and bones in signal red and fixed with MS Clamps , bolts and nuts of approved size (25x20cm) for EHV (66 KV ) or (11000 Volt) ,of suitable size complete, all as specified and directed.
Material and labour for taking down of defective step down transformer 11 KV / 0.433, Opening up the top cover by taking out the transformer oil in a separate container after disconnecting/taking out the HT/LT side electric connections from both the primary & secondary side of the transformer of any type/ description (indoor/outdoor type ) installed on floor/pole for carrying out necessary repair/rewinding to HT/LT side or any other repair as required after shifting the transformer to contractor's work shop including taking out complete core assembly, Magger the winding for identifying the fault/defective winding, seggregating the defective winding portion/taking out, cleaning the laminated core rewinding with appropriate gauge winding wire of existing description for transformer of capacity 400 to 630 KVA including assembling & testing on completion & installation the same at the site complete, all as specified and directed. Note : (i) Winding of coil and spares required as per repair shall be measured and paid separately under respective items. (ii) The transpotation charges and taking down/taking up of transformer are inclusive in the quoted rates. (iii) The cost for the dehydration of transformer oil if reqd shall be measured & paid separately. (iv) The cost of insulation material such as paper, cotton tape , latheroid sheet , casl sheet, Oil seal etc are inclusive in the quoted rate. (v) The transformer will be opened in presence of Egnr-in-charge / JE in charge All testing of transformer after repair will be fwd by Contractor on his duly signed by manufacuturer / factory which repair transformer before despatch from the factory.
All as per Srl Item No 79 above but capacity 300 to 315 KVA complete, all as specified and directed.
All as per Srl Item No 79 above but capacity 200 to 250 KVA complete, all as specified and directed.
All as per Srl Item No 79 above but capacity 75 to 160 KVA complete, all as specified and directed.
Supply and fixing, in replacement, HT coils made out of super enameled double paper coated (DPC) HT copper winding wire of transformers, capacity 75 to 630 KVA, coils to be repalced as per existing number of turns, gauge, insulation value matching with manufactures design complete, all as specified and directed.
Supply and replacement of LT coils made out of super enameled LT copper strip of trasformer capacity 75 to 630 KVA(Note coil to be replaced shallhave same number of turns,gauge,insulation value matching with manufactures design complete, all as specified and directed.
Rubbing/scratching old paint of transformer outer surface of capacity 400 to 630 KVA, through cleaning with kerosene oil and providing two coats of metallic paint outside and inside as applicable including writing MES No on Transformer body with black paint complete, all as specified and directed.
Rubbing/scratching old paint of transformer outer surface of capacity 300 to 315 KVA, through cleaning with kerosene oil and providing two coats of metallic paint outside and inside as applicable including writing MES No on Transformer body with black paint complete, all as specified and directed.
Rubbing/scratching old paint of transformer outer surface of capacity 200 to 250 KVA, through cleaning with kerosene oil and providing two coats of metallic paint outside and inside as applicable including writing MES No on Transformer body with black paint complete, all as specified and directed.
Rubbing/scratching old paint of transformer outer surface of capacity 75 to 160 KVA, through cleaning with kerosene oil and providing two coats of metallic paint outside and inside as applicable including writing MES No on Transformer body with black paint complete, all as specified and directed.
Rubbing/scratching old paint of 66KV power transformer of capacity 6/8 MVA, through cleaning with kerosene oil and providing two coats of metallic paint including writing MES No on Transformer body with black paint complete, all as specified and directed.
Material and labour for painting of PCC poles with two coats of synthetic enamel paint in black and white strip 30 cm wide each up to 1.5 mtr height from coping including writing of pole number with white paint inside black circle of 10 cm dia complete, all as specified and directed.
Supply and fixing in replacement disc type Polymer insulator including one galvanized mild steel spindle,single disc type, two galvanised iron washers & one galvanised nut and other fixing material , 11000 volts grade complete, all as specified and directed.
Supply and fixing in replacement pin type Polymer insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut,150mm height and 150mm dia for working pressure 11000 volts grade complete, all as specified and directed.
Supply and fixing in replacement Post type Polymer insulator suitable for Air break switch including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut , for working pressure 11000 volts grade complete, all as specified and directed.
Supply and fixing in replacement HT Jumpers wire not less than 95 Sqmm HT single core from top disc insulator to GOD and disc to disc in any length with complete nuts & thimbles complete, all as specified and directed.
Calibration of Relays of HT RMU by secondary and Primary injection, replacement of defective operating handles, checking of under voltage, over current relays and replacement of UNSV spare parts of master relays by authorised agency, complete all as specified and directed.
Material and labour for painting to mild steel cross arms, bracing, supports, clamps, back plate etc fixed on HT PCC Poles any height with providing two coats of aluminium paint over a coat one coat of red oxide primer complete, all as specified and directed. Note:- Steel members fixed on single HT pole shall be considered as 'One Unit'.
Supply and laying GI steel tubing, 80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete, all as specified and directed.
Supply and laying GI steel tubing, 100mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wall for protection of Cable / GI wire / GI strip etc complete, all as specified and directed.
Supply & fixing in replace of Compression/Crimping type sleeve joints for jointing conductors/ jumper connections including treatment with conducting jelley complete, all as specified and directed.
Supply and fixing ACSR conductor on HT poles including stringing and fixing in position and binding to insulators and jumpers complete, all as specified and directed.
Dismantling of old ACSR conductor of any size and removal from site complete, all as specified and directed.
Dismantling and taking down cross arms of MS channel or angle sections, clamps, nuts and bolt, washers, back plate of any size/shape complete and removal from site complete, all as specified and directed.
Supply and fixing on HT pole cross arms, bracing supports clamps from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts in any shape or size complete as directed including preparation of surface and painting two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed.
Supply and fixing of fire Extinguisher Co2 type 4.5/5 Kg capacity to fixed on wall including fixing bracket/stand complete, all as specified and directed.
Material and labour for replacement/Topup of deficient transformer oil in transformer of any cap having dielectric strength not less than 60 KV at 4 mm gap conforming to IS complete, all as specified and directed.
Metarial and labour for replacement LT rod assembly with Nut & Bolts of LT side suitable for transformers upto 100 KVA complete, all as specified and directed.
Metarial and labour for replacement LT rod assembly with Nut & Bolts of LT side suitable for transformers Capacity 250 to 315 KVA complete, all as specified and directed.
Metarial and labour for replacement LT rod assembly with Nut & Bolts of LT side suitable for transformers Capacity 400 to 630 KVA complete, all as specified and directed.
Supply and fixing in replacement HT 11 KV bush rod suitable for indoor / outdoor type upto 315 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete, all as specified and directed.
Supply and fixing in replacement HT 11 KV bush rod suitable for indoor / outdoor type upto 400 to 630 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete, all as specified and directed.
Supply and fixing in replacement drain valve cast iron type suitable for 100 to 500 KVA transformer complete with nuts/bolts & packing gasket complete, all as specified and directed.
Supply and fixing in replacement Temprature guage numerical type complete with fitting suitable for 100 to 500 KVA transformer complete with nuts/bolts complete, all as specified and directed.
Material and labour for replacement of battery complete with checking voltage 12 V to 24 V , 150-180Ah complete, all as specified and directed. Note:- 02 Nos battery in each TOP-I, TOP-II and 01 Nos MAP Sub Stns.
Material and labour for preparation of rig/ battery bank cage , suitable for fitting of 14 battery , 2 Volt each made of MS Iron Flat and Angle Iron 40x40x6mm having provision of top cover and locking system including lock and 2 keys and fixed in ground upto 25 cm grouted in ground and min 25 cm above ground complete, all as specified and directed.
Material and labour for replacement of HT Copper bus bar 1200 Amp, suitable for HT VCB used for common Bus bar in VCB Panel including cutting as per site and making holes for cable connections complete with HT insulation as per colour coding RYB and as required at site complete, all as specified and directed.
Supply and fixing install in replacement Heavy duty battery charger 24 V suitable for charging of battery bank of VCB complete, all as specified and directed.
Supply and fixing out door type , polymer , triple pole, 11000 volts mechanically operated Air break switch (GOD + DO), mounted on 15 Nos insulators and steel frame, with operating mechanism worked from ground level for current rating up to 200 amps and all accessories ie pipe clamp etc complete, all as specified and directed.
Supply and fixing in replacement for copper strip of size 32x6 mm from test point to transformer or other places complete, all as specified and directed.
Metarial and labour for PCC ( 1 : 3 : 6 ) type C2 using 40mm graded stone aggreghate for foundation of poles and stay assembly complete, all as specified and directed.
Supply and fixing in replacement of stay assembly comprising of 7/2.50mm galvanized MS stay wire of reqd length, fixed to poles with and including of FI clamps made out of FI 40x6mm and nuts bolts washers of suitable size MS stay bow 14mm dia galvanized 40cm long MS galvanised stay rod threaded with nut 16mm dia 21 Cm long with washers MS stay plate galvanized 230x30x6mm and stay wire complete, all as specified and directed. Note necessary Excavation and PCC shall be measured and paid seprrately.
Metarial and labour for CRC electra clean for dusting/rusting/ carbon cleaning on VCB Mechanism of 400 ml capacity suitable for 11 KV VCB and air break switches complete, all as specified and directed.
Routine testing of 66 KV assets by Power Grid Corporation of India/PSEB and authorised rep of manufacturer to be tested are as under ;- (a) Transformer 66 KV 6.3/8 MVA - 02 Tests to be carried out (i) IR value test of both transformer and bushings. (ii) PI value test for 20 seconds and 120 seconds. (iii) No load current test. (iv) Magnetic balance test. (v) Short circuit test. (vi) Testing of tap changer. (vii) Tan/delta test of transformer. (viii) Dielectric strength of transformer Oil (xi) Dissolved gas analysis test (b) 66 KV SF-06 Breaker (03 Nos) - Tests to be carried out by the power Grid Corporation of PSEB Protectiion team. Following test shall be carried out :- (i) IR value both in open and close position. (ii) Continuity of breaker in closed position. (iii) Tripping and closing of breaker. (iv) Functioning of all the tripping system/relays displayed on the control relay panel-such as differential o/c, earth fault, metering circuits and all other protection emanating from transformer - oil temp trip, OLTC trip, winding temp gauge trip, bucholz relay, inter trip etc, calibration of all the relays and complete Panel for time observed with respect to time set primary injection of all the CTs, complete all as specified and directed.
(v) Greasing/oiling of all the moving parts. (vi) Operation/working of charging motor and limit switch. (c ) Testing of 11KV, VCB breaker- 16 Nos through Power Grid Corporation of India PSEB. The equipments to be tested through Protection team PSEB are as under:- Following tests to be carried out on each breaker ( Nos of Breaker - 16 Nos) ;- (i) IR Value for open/close circuit- fault relay, over load earth fault relay etc (ii) Tripping and closing time in M/S. (iii) Operation - both manual and through motor. (iv) Functioning of indicators. (v) Continuity. (vi) CT ration through primary injection. (vii) Polarity test. (viii) Testing of all the protection relay - i.e. o/c, earth fault, instantaneous, trip suspension, auxiliary relay etc. (ix) Operation/working of charging motor and limit switch. (x) Calibration of all relay, male, female contracts of VCB. Notes : (i) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after. (ii) Test sheet shall be prepared as specified under PS clause and shall be produced.
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (NRC MAP Ph II ) (a) Tests to be carried out on each breaker ( Nos of Breaker - Five in NRC II)
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- ( Kathania MAP Ph II) (a) Tests to be carried out on each breaker ( Five in Kathania II)
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (Khterpal MAP Ph II ) (a) Tests to be carried out on each breaker (Nos of Breaker - Nine in Khterpal II)
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (NOC MAP Ph II ) (a) Tests to be carried out on each breaker ( Nos of Breaker - Three in NOC II )
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (TOP-I Sub Station ) ( Nos of Breaker - Seven in TOP-I )
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (TOP-II Sub Station ) ( Nos of Breaker - Ten in TOP-II )
Metarial and labour for testing of 11KV breaker through Power Grid Corporation of India , through PSEB Protection team are as under:- (NME MAP Ph II), tests to be carried out on each breaker ( Nos of Breaker - One in NME Ph II) Note for srl Item No 122 to 129, following tests to be carried out on each breaker (i) IR Value for open (ii) Tripping and closing time in M/S. (iii) Operation - both manual and through motor. (iv) Functioning of indicators. (v) Continuity. (vi) CT ration through primary injection. (vii) Polarity test. (viii) Testing of all the protection relay - i.e. o/c, earth fault, instantaneous, trip suspension, auxiliary relay etc. (ix) Operation/working of charging motor and limit switch. (x) Calibration of all relay, male, female contracts of VCB. (xi) Any part/spare found defective during testing shall be repaired/replaced for which payment shall be made separately against respective items here in after except for minor parts such as packing, nuts bolts, cotton waste etc for which cost shall be deemed to be included in the unit rate quoted for this item.
Karachi Engineers (BID ID -3145824)
kailu construction co (BID ID -3138939)
R D Bansal (BID ID -3145868)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .