Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.1 CrAccepted-AOC | ₹11.1 Cr Quoted ₹11.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹11.3 CrRejected-Finance | ₹11.3 Cr | L2 | Rejected-Finance Not being L1 |
| 3 | L3₹12.0 CrRejected-Finance PLOT NO G 36 SECTOR 20 NAVI MUMBAI 400614 | THANE | MAHARASHTRA | 400614 | ₹12.0 Cr | L3 | Rejected-Finance Not being L1 |
| 4 | L4₹12.2 CrRejected-Finance NORTH SITE TROMBAY MUMBAI 400 085 | MUMBAI SUBURBAN | MAHARASHTRA | 400085 | ₹12.2 Cr | L4 | Rejected-Finance Not being L1 |
| 5 | L5₹12.3 CrRejected-Finance | ₹12.3 Cr | L5 | Rejected-Finance Not being L1 |
Tender Value
₹11.3 Cr
EMD Value
₹9 L
Closing Date
7 Jun 2023, 6:00 pmClosed
Sr.DDG and CE
DGNP Mumbai, SBS Road, Lion Gate, Mumbai-400023
AUGMENTATION OF PLATFORM LEVEL EMI/EMC TEST FACILITY AT NAVAL EMC CENTRE, NAVAL DOCKYARD MUMBAI
2022_MES_566241_1
DGNP_MES_8539_1
Open Tender
Civil Works
780 days
NAVAL DOCKYARD MUMBAI
As per tender documents
8 documents required · 8 mandatory
₹3,000
Yes
DGNP Mumbai
₹9 L
Yes
24 Aug 2023
30 Nov 2022
14 Jun 2023
30 Nov 2022
7 Jun 2023
22 May 2023
Amount
LIST OF WORKS (Schedule A Part I to Part XVII)
Total amount of Sch 'A' Part-I (Building) brought forwarded from sl page No 29 (R)
Total amount of Sch 'A' Part-II (Demolition and Dismantling) brought forwarded from sl page No 31 (R)
Total amount of Sch 'A' Part-III (Pile Foundation) brought forwarded from sl page No 32 (R)
Total amount of Sch 'A' Part-IV (Earth work & site clearance) brought forwarded from sl page No 35 (R)
Total amount of Sch 'A' Part-V (Internal Water Supply) brought forwarded from sl page No 36 (R)
Total amount of Sch 'A' Part-VI (Sewage Disposal) brought forwarded from sl page No 40 (R)
Total amount of Sch 'A' Part-VII (Area Drainage) brought forwarded from sl page No 42 (R)
Total amount of Sch 'A' Part-VIII (Compound Wall) brought forwarded from sl page No 46 (R)
Total amount of Sch 'A' Part-IX (Intenal Electrification) brought forwarded from sl page No 53 (R)
Total amount of Sch 'A' Part-X (External Electrification) brought forwarded from sl page No 57 (R)
Total amount of Sch 'A' Part-XI (External Water Supply) brought forwarded from sl page No 59 (R)
Total amount of Sch 'A' Part-XII (Fire Alaram and Fire Fighting) brought forwarded from sl page No 67 (R)
Total amount of Sch 'A' Part-XIII (Lighting Protection) brought forwarded from sl page No 68 (R)
Total amount of Sch 'A' Part-XIV (Cooling Appliances) brought forwarded from sl page No 69 (R)
Total amount of Sch 'A' Part-XV (Air Conditioning) brought forwarded from sl page No 72 (R)
Total amount of Sch 'A' Part-XVI (Lifts) brought forwarded from sl page No 74 (R)
Sch 'A' Part-XVII ( MISCELLANEOUS ) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Internal Water Supply Health faucet 8mm dia with 1.2 mtr long flexible tube and wall hook complete all as specified and directed. Make: Jaguar Model No. ALDCHR-573 or equivalent in Crabtree/ Kohler.
Angular stop cock with wall flange 15mm dia complete all as specified and directed. Make: Jaguar Model No. ARI-39053 or equivalent in Crabtree/ Kohler.
Pillar taps fancy type 15mm dia cast copper alloy with capstan heads, chromium plated screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipes and fixed for WHB (Code NO OPP-15001PM of JAGUAR or equivalent make in crabtree/Mare) complete all as specified and directed.
Piling Work Boring for bored cast in situ pile (dia between 600 & 750 mm) through any depth & any type of soil, clay, and getting out & disposal of spoil to any distance outside of MoD land and depositing at a place as directed by the Engg In Charge using DMC method (Direct Mud Circulation/ rortary rig method).
600 mm dia piles
750 mm dia piles
Boring Through Rock Boring through any depth in soft disintegrated rock / boulders / hard rock and cleaning out all debris and cleaning the bore using air jet and disposal of spoil to a distance outside MoD land and depositing at a place as directed by the Engineer-in-Charge using DMC method for Pile dia between 600 & 750mm.
600 mm dia piles
750 mm dia piles
MS Liners:- Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete for providing and fixing in position permanent MS pile liner 6mm thick plated including cleaning removing rust and welding and placing all complete as directed by Engineer-in-Charge, (measurement shall be limited to cut off level).
Testing of piles: Conducting non destruction pile integrity test using low strain method on cast-in-situ piles including mobilising of equipment and de-mobilisation after completion of testing data analysis and submission of report as per IS- 14893 of 2001 for pile of following sizes all as directed.
600mm dia piles
750mm dia piles
Initial Load Testing Dynamic testing (High Strain Dynamic) on piles 600mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed.
Initial Load Tesing Dynamic testing (High Strain Dynamic) on piles 750mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed.
Routine Load Testing Dynamic testing (High Strain Dynamic) on piles 600mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed.
Routine Load Testing Dynamic testing (High Strain Dynamic) on piles 750mm dia all as per IS-2911, Part-IV including bringing on site all equipment required and removal from the site after testing is completed.
ARBORICULTURE Developing lawn which includes necessary earth work excavation to a depth of 30cm average 15cm in any type of soil and removing roots and vegetation from the soil and excess excavated material outside MoD land and levelling and applying soil pesticides turfing korean grass of approved quality material & labour, complete all as directed.
Developing ornamental trees (temple free dwarf) by digging pits of 0.30m x 0.30m x 0.30m and filling with red earth and manure in the proportion 3:1 and supply & planting trees of different varieties not less than 500mm height and one year old with proportionate girth in the filled up pits at a given distance and with plant life guarntee for defects liability period of 02 years from the date of completion of work etc complete all as directed by Engineer-in-Charge. Note: Red Soil & Organic manure shall be measured and paid separately as supply only.
Supply only red soil of approved quality all as directed.
Supply only organic manure of approved quality all as directed
Internal Electrification Ceiling fan 1200mm sweep, energy efficient 5 star rated and connecting up including provision of cable from ceiling rose or connector to fan with flexible cable of size 24/0.2 mm with copper conductor all as specified and directed. Make Havells ES 40, ES 50 or equivalent make in any other make mentioned in list of make
Fresh air fan exhaust fan with plastic Body 250mm sweep complete fixed to wall with suitable MS bolts, grouted to wall and connecting up including provision of three core flexible cable of size 24/0.2mm with copper conductor from ceiling rose to exhaust fan complete all as specified and directed. Make Havells Ventil Air DX, or equivalent make in any other make of approved manufacturer.
Exhaust fan with louvers metal Body 300mm sweep complete fixed to wall with suitable MS bolts, grouted to wall and connecting up including provision of three core flexible cable of size 24/0.2mm with copper conductor from ceiling rose to exhaust fan complete all as specified and directed. Make Havells Turboforce SP or equivalent make in any other make mentioned in list of make
TPN Vertical Loadline distribution board suitable for MCCB, factory made double door flush type made from sheet metal duly powder coated for single phase outgoing and three phase TP 4P MCCB as incomer, with 200 Amps rated bus bar, 415 V, 4 way flush with wall complete with all accessories all as specified and directed. Make Havells Cat No.DHDLVDRWGOFO04 or equivalent make in any other make mentioned in list of make
Recess mounted LED Ceilng light environment friendly aestetically designed with high brightness and SMD LEDs as light source suitable for Amstrong grid ceiling and integral electronic driver 42 W (2'x2').and including connecting up with copper conductor cable all as specified and directed. Make : Havells Pluto Neo 2X2 PLR 42WLED 840S / Crompton PLUTONE 02X2 PLR28WLED840 or equivalent make in any other make mentioned in list of make
Recess mounted LED Ceilng light environment friendly aestetically designed with high brightness and SMD LEDs as light source suitable for Amstrong grid ceiling and integral electronic driver 28 W (2'x2').and including connecting up with copper conductor cable all as specified and directed. Make : Havells Pluto Neo 2X2 PLR 28WLED 840S / Crompton PLUTONE02XZ PLR28 WLED 84 or equivalent make in any other make mentioned in list of make
Wall mounted LED batten extruded aluminium housing for efficient heat dissipation with poly carbonate diffuserand integral electronic driver 22 W (4').and including connecting up twin core twisted flexible copper conductor cable all as specified and directed. Make : Havells Endura liner Cat No : ENDURALINEARNEOBS22WLED865SPCWH or equivalent make in any other make mentioned in list of make
Wall mounted LED battern extruded aluminium housing for efficient heat dissipation with poly carbonate diffuserand integral electronic driver 10 W (2').and including connecting up twin core twisted flexible copper conductor cable all as specified and directed. Make : Havells Endura liner Cat No : ENDURALINEARNEOBS10WLED865SPCWH / or equivalent make in any other make mentioned in list of make
LED decorative wall mounted brushed nickel finished fixture with opel glass diffuser suitable for 2x 9 watts LED, B22 base, luminaire provided including all accessories and intenally pre-wired all as specified and directed. Make : Havells FLORENTINE WL2LSB22SS Cat No : LHFOAJE2TZ1I060 or equivalent make in any other make mentioned in list of make
LED decorative wall mounted bulkhead light fitting 10watts all as specified and directed. Make : Havells HEXAFT10WLED857SSYMBOPC or equivalent make in any other make mentioned in list of make
LED building security light fitting 45 watts cast aluminium housing in gray finish with clear acrylic and cast aluminium pipe mounting attachement with all accessories and pre wired complete including PVC three core flexible copper conductor cable from ceiling rose to connector of fittings all as specified and directed. Make: Havells Endurs city liner NEO cat No ENDURAPEARLNEOSL45WLED757PASYTOPC or equivalent make in any other make mentioned in list of make
GI pipe bracket bent to shape drilled welded made out of light grade GI pipe 50mm bore 0.90 mtr long for fixing of street light fitting or any type and description including GI clamps huts bolts & washers complete as per site requirement all as specified and directed.
LED bulb with B22 base 3 star cool day light 9 watts for decorative fittings, complete all as specified and directed, Make Havells LHLDEUEBMLZ010 or equivalent make in any other make mentioned in list of make
RJ 11 Telephone jacket complete with modular box, front plate and cover complete all as specified and as directed.
RJ 45 Lan input output network jack, Gangbox and single post face plate, complete all as specified and directed.
LT Panel board compartmentalised , made out of CRCA sheet 3.15mm thick, cubical type water/weather proof, factory made with front and back opening type, suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply, having 3 Nos aluminium bus bars of 800 amps and Neutral bus bar of 400 amps capacity duly insulated with heat shrinkable colour coated Sleeve complete, painted with powder coated with pure polyster, 60 microns thickness RAL-7032 code with locking arrangement, mounted on base channel of ISMC 75x40 mm grouted with PCC foundation all as per manufacturer's instructions complete all as specified and directed. The feeder filler box provided with the following accessories :-
LT Panel board compartmentalised , made out of CRCA sheet 3.15mm thick, cubical type water/weather proof, factory made with front and back opening type, suitable for 415 volts, 3 phase, 4 wire, 50 Hz, AC supply, having 3 Nos aluminium bus bars of 600 amps and Neutral bus bar of 300 amps capacity duly insulated with heat shrinkable colour coated Sleeve complete, painted with powder coated with pure polyster, 60 microns thickness RAL-7032 code with locking arrangement, mounted on base channel of ISMC 75x40 mm grouted with PCC foundation all as per manufacturer's instructions complete all as specified and directed. The feeder filler box provided with the following accessories :-
MCCB 32A, 4P, 35A, 415V Fixed to sheet metal enclosure in machine room including fixing to MS pedestal for passenger lift, complete all as specified and directed.
MCCB 40A, 4P, 415V Fix to sheet metal enclosure including fixing to MS pedestal in machine room for goods lift, complete all as specified and directed.
Disconnecting existing LT power cables from the existing LT panels at EMI-EMC centre building, complete all as directed.
Relaying retrieved cable and connecting to the new building complete all as directed.
GI perforated cable tray fixed with thread rod and bracket suspended from ceiling powder coated with pure polyster 60 microns thickness all complete all as specified and directed.
Earthing complete with GI pipe electrode 40mm dia buried directly in ground (earth pit less than 2.25m deep below normal ground level) with top edge of plate not less than 1.5meters below normal ground level earth plate connnected to G earth wire 4mm dia by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 of MES SSR-2009 (Part I Specifications) connected to earth test point all as specified or indicated including testing on completion including necessary excavation and earth work in any type of soil and adequate quantity of charcol and salt in alternate layer around the earth plate including PCC chamber 1:2:4 type B2 earth pit cover in RCC 1:2:4 type B1 (using 20mm grade aggregate) with 8mm CTD bar @ 140mm c/c in both ways including necessary form work angle iron frame including 20mm dia GI pipe for watering purpose with the arrangement of funel and wire mesh including GI pipe of 15 mm dia bore for earth lead protection, complete all as specified and directed.
Chemical Earthing complete with copper earth plate electrode 90cmX60cmX5mm thick, buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of plate not less' than 1.5meters below normal ground level, earth plate connected to copper earth strip 32x6mm by means of bolts, nuts check nuts and washers of galavanised iron or steel all as shown in electrical plate No 3 of MES SSR-2009 (Part-I specifications) connected to earth test point all as specified or indicated including testing on completion including necessary excavation and earth work in any type of soil and adequate quantity of suitable chemical compound for alternate layer around the earth plate, including PCC (1:2:4) pit and 10mm thick C.I cover with arrangement of hinge to 40x40x6mm C.I angle iron frame, including 20mm dia G.I pipe for watering purpose with the arrangement of funel and wire mess, inclduing GI pipe of 40 dia for earth lead protection. complete all as specified and directed. Note: The maintenance free chemical for earthing shall be of M/s Pragathi Electrocom model LOHM or any make approved by command CE/NABL.
External Water Supply Horizontal open well submersible pump set capable of pumping 700-170 LPM at 24-38Mtr head, squrrel cage induction motor suitable for operation on AC 3 phase 415 volts 50Hz of 5 HP copper cable from starter to motor complete all as specified and as directed.
Electrical earthing with GI pipe electrode of size 40mm dia buried directly in ground vertically earth pit not less than 2.25 mtr deep below normal ground level with the top edge of the earth plate at a depth not less 1.5 mtr below normal ground level connected to GI earth lead of size 4mm by means of bolts nuts washers made of galvanised iron and connected to main control board/switch gear/pannel boards all as specified and shown in Electrical plate No 3 of MES schedule (SSR-2009) Part-1 including necessary excavation and earth work in any type of soil charcoal dust salt and PCC 1:2:4 type B1 in chamber RCC 1;2:4 type B1 cover slab 40mm thick with 6mm dia mild steel bars at 100mm center to center both ways and with 6mm dia MS hook complete and testing resistance all as specified and as directed.
Fire Alarm and Fire Fighting Cast iron air release valve with single air outlet conforming to IS14845 of size 50mm dia bore and fixing up in cast iron water supply mains complete all as specified and directed.
2 core x 1.5 sqmm stranded copper conductor PVC insulated, PVC sheathed, aluminium myler tape shielded FRLS armoured cable buried in ground or laid in existing pipe complete all as specified and directed.
Wall mounted LED emergency exit sighnage luminaire lit up using regular mains supply comes with a unique rechargeable Ni-Cd battery capable of emergency back up to 2 hrs, complete all as specified and directed.
Fire extinguisher clean agent 4.0 Kg complete all as specified and directed.
Fire extinguisher CO2 type 4.50 Kg complete all as specified and directed.
Air Conditioning Hi-wall split units indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 1.5 TR, complete all as specified and directed.
Hi-wall split units indoor/outdoor complete with cordless remote control unit and within built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 TR, complete all as specified and directed.
Dismantling of split AC 1/1.5 Ton from its original position by dismantling the electrical connections refrigerant connections bracket nut bolt etc and keeping in safe custody for refixing in a different location.
Dismantling of window AC 1/1.5 Ton from its original position by dismantling the electrical connections, casing etc and keeping in safe custody for refixing in a different location, complete all as specified and directed.
Refixing the retrieved split / Window type AC 1/1.5 Ton in the new position with bracket making all connections of refrigerant lines gas charging with suitable refrigerant to the specified pressure servicing the Air Conditioner replacing filters etc including testing commissioning for satisfactory performance, complete all as specified and directed.
Modular type 100% all inverter variable refrigerant flow outdoor unit (ODU) comprising of hermetically sealed inverter variable speed scroll compressors high efficiency low noise condenser fan with guard and IP 55 rated motor, heat exchanger & coated fins for increased duarability; powder coated casing etc alongwith liquid line strainer catch all drier thermostats etc suitable for interconnecting with any type of indoor units with cordless remote controller/air handling unit complete all as specified and directed.
112 HP/89TR (28HP x 04 Nos) top discharge outdoor unit (ODU) Make: Bluestar Model No: IVRFB-28TCN or equivalent model in Daikin, Carrier Voltas.
AHU Expansion Kit Make: Bluestar Model No:VAEKIT-320 or equivalent model in Daikin, Carrier Voltas Notes: (i) The ODU & IDU shall be integrated with special super wiring system with the central monitoring control. (ii) The unit shall be factory wired and tested before dispatch. (iii) The operating refrigerant shall be R410A only. (iv) The unit shall be IBMS compatible with open protocol. (v) The ODU shall give 100% capacity at 43C ambient temperature. (vi) The COP of ODU shall be more than 3.4 at design conditions.
Refrigerant copper piping insulated with 19mm/13mm thick nitrile rubber of following sizes between ODU to IDU, complete all as specified and directed.
54.0 mm OD (insulation 13mm thick)
44.5 mm OD (insulation 13mm thick)
41.3 mm OD (insulation 13mm thick)
34.9 mm OD (insulation 13mm thick)
28.6 mm OD (insulation 19mm thick)
22.2 mm OD (insulation 19mm thick)
19.1 mm OD (insulation 19mm thick)
15.9 mm OD (insulation 19mm thick)
12.7 mm OD (insulation 19mm thick)
Variable refrigerant flow distribution REFNUTS (Y-Joints) of appropriate size in the suction and liquid lines complete all as specified and directed. Make : Bluestar, Daikin, Carrier, Voltas Notes: (i) The make of REFNUT shall be the same as the make of ODU.
Factory made CRI type tested outdoor cubical compartmental type "HVAC Panel" of suitable size conforming to IEC 61439-1 & 2, IEC 61641 having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 3.15mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size including earthing stud labeling painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process) duly fixed in ground with PCC foundation (1:2:4) type B1 with danger notice plate of 1.6mm thick mild steel sheet vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour suitable for 3 phase 4 wire system 500V grade with necessary wiring PVC sheathed standed copper conductor of appropriate length & size including fixing lugs bolts screws etc. complete with accessories as specified and directed. Make : Schneider, ABB, Siemens, L & T
The HVAC panel shall comprise of the following Busbar Chamber: (i) 01 set (3L+N) of copper busbar of rated capcity 320A covered with PVC insulated sleeves including insulator nuts bolts etc with complete connection. Incoming (i) 250A, 415V, Ics=Icu=36kA conforming to IEC 60947-2, 50Hz, FP MCCB with adjustable thermal settings (0.70-1x In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD) with complete connection -01 Nos (ii) CI 1.0 multifunction meter capable of measuring V,A,F,PF,W/VA,Wh/VAh Runhrs Onhrs & interrupts - 01 Nos (iii) LED phase indicators (Red, Yellow, Blue) - 01 Set Outgoing (i) 63A, 415V, Ics=Icu=36kA conforming to IEC 620947-2,50Hz, FP MCCB with adjustable thermal settings (0.70 - 1 x In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD) with complete conneciton -06 Nos [04 Nos for ODU: 01 No for AHU * 01 No for SPARE] (ii) LED phase indicators (Red, Yellow, Blue) -06 Set (iii) CI 1.0 multifunction meter capable of measuring V,A,F,PF,W/VA,Wh/VAh Runhrs. Onhrs & interrupts- 06 Nos NOTES: (i) The panel shall be purchased from the original equipment manufacturer (OEM) only. (ii) The bidder shall furnish dimensional drawings of the items offered indicating all the fittings, dimensional tolerances,GADs etc. for approval of the Engineer-in-Charge.
1.1 KV grade 4 crore 6.0 sqmm copper conductor, XLPE insulated armoured cable conforming to IS 7098 (Part-I): 1988 having stranded copper compact shaped conductors as per CL 2 of IS 8130 :1984, PVC inner sheath single armoring of galavanised steel strip/wire and PVC type ST-2 outer sheath conforming to IS 5831 :1984 including necessary clamping/dressing with cable ties and termination complete all as specified and directed. Make : RR Kabel, Polycab, Havells
Drain water piping including necessary fittings viz. flexible connections, bends, tees, reducers, flanges, air purge valves, drain valves structural support, necessary clamps, vibration isolators etc. including painting and supporting / fixing the pipe in excavated trenches or on floor/ wall / ceiling with clamps, hangers, angles , channels (using anchor fasteners) with necessary accessorie, duly insulated complete all as specified and directed by the Engineer-in-Charge. 15mm NB Make: Tata, Jindal, Surya Notes: (i) The pipe size 150mm NB & below shall be MS 'C' class as per IS 1239 (Part-I) : 2004 & IS 1239 (Part-2): 2011. (ii) The pipe size above 150mm NB shall be welded black steel pipe heavy class as per IS 3589:2001. (iii) Minimum thickness of MS sheet for pipe size above 150mm NB and upto 350mm NB shall be 6.35mm and it shall be 7 mm for pipe size 400mm NB and above.
PN 25 rated forged brass ball valve having lever operated two piece design renewable P.T.F.E seat brass ball machined brass nickle plated stem, P.T.F.E packings, full bore port opening, screwed female BSP parallel thread end connections body test pressure 40 kg/cm2 Hyd and working pressure 25 Kg/cm2 Hyd duly insulated with elastomeric thermal insulation with adhesives and other necessary accessories complete all as specified and directed. Make : Advance Sant Hindustan
6" (six inches) dual scale ("F/C), lower mount (radial) bimetal thermometer having 0.5 NPT process connection, Grade A accuracy class as per ASME B40.200, stem diameter 6.35mm laminated safety glass window stainless steel 304 case steam process connection & joint aluminium dial & pointer IP67 protection scale range 0-60C complete with accessories etc as specified and directed. Make: General WIKA TSI
4" (four inches) bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element plastic black pointer & case plastic crystal-clear window, snap-fitted in case accuracy class 2.5 scale range 0-25 bar complete with accessories etc as specified and directed. Make : General, WIKA, TSI
20000 CFM @ 60 mm w.g. static pressure double-skin type horizontal, floor-mounted, top / side discharge air handling unit and having thermal break profile complete with air-tight casing using gaskets and self-adhesive tapes 0.6 mm thick pre-coated outer skin and 0.6 mm thick GI inner skin, 45±2 mm thick double skin panel with pressure injected CFC/HCFC free PUF having 'k' value of 0.02 W/°C/m & density 40 kg/m³, AMCA certified energy efficient plug fan(s) with backward curved impellers for high static pressure mounted on aluminium extruded siderail base frame with VFD, EU4 pre-filter and EU7 fine filter (mounted on a common frame), combination of 6/8 rows deep chilled water coil(s) with anti-corrosion aluminium fins, suitable high efficiency (IE2) TEFC squirrel cage induction motor, PVC/nylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan, vibration isolators/rubber pads (minimum 1" thick) inspection windows / doors, mixing box and supply / return / fresh air openings fitted with aluminium volume control dampers, thermostate & humidistate,etc. complete all as specified and directed. Make: Vayhan, Citizen, Trane, Flakt Group
The AHU shall comprise of the following: [a] Suitable SISW backward curved plug fan, dynamically balanced, with AMCA certified blower. [b] 4 Pole, TEFC, high efficiency (IE2), squirrel cage induction motor, conforming to IS 12615: 2018, having BHP rating 20% higher than the peak capacity with VFD suitable for 415 V±10%, 50 Hz, 3-Phase AC power. [c] Flexible connection made with airtight ASTM E84 (Class I) polyester fire retardant cloth riveted on periphery of cloth with extruded aluminum 'L' angle flange as per fan size at discharge duct/plenum. [d] Washable type of 'EU4' filter (pre-filter, efficiency 90% down to 10 micron) and 'EU7' filters (Micro Vee filters, efficiency 99% down to 3 micron). [e] 6 / 8 rows deep DX type cooling coil section duly insulated with 13 mm thick closed cell polyethelene having 0.15 mm thick aluminum fins and 0.28 mm thick copper tubes of 9.5 mm OD tested on 21 kg/cm², with SS sandwiched drain tray, etc. (a 350 mm service section between eliminator and heater is required). [f] Condensate drain pan fabricated from 20 gauge SS 304, powder coated and insulated with elastomeric insulation of suitable thickness.
16 gauge GI fire damper, at least of 120 minutes fire-rating, spring activated on melting of fusible link having melting point 67.13° C complete with smoke detector / thermister, fusible link etc. and actuator as required for operation, located in the SA / RA ducts, at all fire rated crossoevers (shafts, walls, etc.). along with control panel (located in such a way that the reset can easily be done), interlocked with the building management system for the fire detection or HVAC to trip / close in the event of fire/smoke in the respective zone and tested as per ULL- 555 and certified by CBRI complete all as specified and directed.. Make: Ruskin Titus, Trox, Rola Star, Zeco The fire dampers shall meet the following criteria: [a] Bare fire dampers with 400 mm sleeve. [b] Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position. [c] Interconnection wire for the fire detection & alarm system with the AHU and the smoke dampers. [d] Sealing any openings around the sleeve of the fire dampers with approved fire sealant as per the specification & recommandations of the manufacturer.
Motorized, spring return type, combination fire and smoke damper, complete all as specified and directed.
Control panel actuator, including electrical spring type actuator, remote indication of the fire damper position.
High performance airfoil class 1A leakage rated GI volume control damper having galavanised steel hat channel frame reinforced with corner braces, galavanised steel airfoil shaped blades ( double skin construction) of 14 gauge thickness, neoprene blade edge seals flexible metal compressible jamb seals stainless steel sleeve linkage concealed in frame etc tested as per AMCA standard 500-D-98 complete all as specified and directed. Make: AIr Flow Caryaire Dynacraft Ravistar
Factory aluminium round/ rectangular low pressure ducting of following sheet thickness having powder coating on both sides and complete with neoprene rubber gaskets elbows splitter dampers vanes volume control dampers hangers supports etc as per approved drawings and conforming to IS 655 : 2006 & the latest edition of HVAC Duct Construction standards- Metal and Flexible of SMACNA alongwith required scaffolding work to install the ducts at site complete all as specified and directed. Make : Approved Manufacturer of SMACNA Standard.
Notes for item No. 82.0 to 82.03 :- (i) Duct connection shall be carried out by angle flange technique (ii) The quoted shall be inclusive of hangers & supports etc (iii) Volume control damper shall be measured and paid for separately.
Square / rectangular /round neck ceiling diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square /rectangular inlet being an integral part thereof an inner core assembly consisting of fixed deflection louvers, heavy gauge steel volume control damper operable from the face of the diffuser by removing the spring loaded inner core assembly, throw reducing vanes anodic acrylic paint finish etc. and tested as per ANSI/ ASHRAE standard 170-1991 complete all as specified and directed.
450mm x 450mm rectangular neck 4-way discharge ceiling diffuser having neck velocity < 600 ft/min throw > 19 @ 150 ft/min velocity NC < 26 for air flow > 1220 ft3/min, complete all as specified and directed. Make: Ruskin-Titus, Caryire, System Air, Air Master.
Square / rectangular /round neck ceiling diffuser for fixed, horizontal discharge pattern consisting of an outer frame assembly with a square/ rectangular inlet being an integral part thereof an inner core assembly consisting of fixed deflection louvers, anodic acrylic paint finish etc and tested as per ANSI/ ASHRAE standard 170-1991 complete all as specified and directed.
FM approved fibre-free, super-silent, microbe resistant, easy to apply 10 mm thick acoustic duct lining insulation of open cell elastomeric foam based on synthetic rubber tested for acoustic performance as per EN ISO 354, EN ISO 11654: 1997 & ASTM C 423, service temperature range -20- 85 ˚C as per EN 14706 & EN 14304, thermal conductivity λ ≤ 0.047 W/mK at mean temperature θm = 20 ˚C as per EN 12667, Class 1 surface spread of flame as per BS 476 7: 1997, flammability HB, V-0 as per UL- 94, anti-microbial behaviour (no fungal growth visible with the naked eye & no bacterial growth) as per EN ISO 846, air erosion resistance (no erosion, cracking or delamination at air velocity of 10000 FPM) as per ASTM C 1071- 05, density 140- 180 kg/m3 along with adhesives and other necessary accessories complete all as specified and directed. Make: Armaflex, Vidoflex, Kalmenflex
Indoor type wall mounted digital temperature cum %RH meter (Digital Thermo Hygrometer) complete with large LCD, English display having operating with 12/24H Max/Min temperature and humidity memory function range -50°C to 70°C Temperature accuracy 0.5 ºC and Humidity range 10% to 99% RH Humidity accuracy 5% RH Humidity resolution 1% RH Power source 1*AAA (1.5V) battery for AC Plant Room complete as specified and directed. Make : Honeywell, HTC, General
Note for item No. 87.0 & 88.0 :- 1. Lift Well / Shaft Size : Approx 1900 mm (W) x 1900 mm (D), Pit Depth :1600 mm, Clear Door Opening : 800 mm (W) x 2000 mm (H) for 08 Passenger Lifts (544 Kg) and Shaft size 2100mm x 2300 mm and pit depth 1600 mm, for Goods lift (1000 Kg) 2. Contractor shall take care of all safety measures and all safety precautions to be followed by the staff and the same to be ensured by contractor. 3. Any addition / alteration cost required including all civil works like breaking of PCC, Plastering, New PCC, RCC etc to be carried out by the contractor.
Note for Item No. 87..0 & 88.0 ( Contd/-) 4. The following items shall be provided and the unit rate quoted above shall be inclusive for the same . (a) Gearless Electric motor, AC, 3 phase, 415V, 50Hz of suitable capacity including necessary cabling with ISI marked FRLHS Cable and fire resistant conduits as required. (b) Standard Wall / Floor mounted Lift Control Panel Board with suitable capacity 4 pole RCCB as incomer. (c) Mechanical guide rail in 'T' section with tongue and groove arrangement for smooth operation of car and counter weight. (d) Type of operation shall be single automatic push button type . (e) Minimum 4 Nos SS Finish 3W LED Fittings connected to Inverter supply and 02 Nos Blower Fan with Switch in lift car.
Note for Item No. 87..0 & 88.0 ( Contd/-) (f) Minimum 10 Nos 7/9W LED Bulk Head Fittings for lift well lighting and 10 Nos 5Amps Plug Point incl point wiring with 1.5Sqmm FRLHS cables and control switches. (g) Type of signal system - Hall button with digital hall position indicator, digital car position indicator in car fixtures in stainless steel face plates. (h) Capacity of ARD battery (High Amp Hour) should be suitable to perform minimum three continous rescue operation. (l) All necessary Grouting Plates / Bolts, Nuts, bolts, washers etc. (j) Provision of hoist way and governors rope and governor. (k) Provision of new buffer spring as per manufacturers design. (l) Provision of battery operated alarm and emergency light through inverter of suitable capacity having power back up for a period of minimum 30 minutes . (m) Drive - Permanent Magnet Gearless Machine frame fixed in the machine room. (n) Progressive type and bydirectional Over speed governor monitors the speed and triggers safety gears etc shall be installed in the machine room.
Note for Item No. 87..0 & 88.0 ( Contd/-) (o) Necessary scaffoldings in lift well. (p) Pit Ladder. Safety Measures:- (i) Overload relays. (ii) BMS Compatibility / Potential Free Contactors (Emergency Stop / Opening, Direction Up / Down, Failure, Main mode etc. and fuses. (iii) DO /DC Button and NS Button.(iv) High Quality Electrical Terminals / Sockets.(v) Limit switch with accessories on each doors / cage.(vi) Gravity / counter weight limit switches for top most position.(vii) Break Magnet of suitable size with manned released arrangements.(viii) Reverse Phase / Phase sequence corrector. (ix) lift door should be minimum 2 Hrs. fire resistance as specified in IS-14665.(x) Automatic condition monitoring of Polyurethane - Coated Steel Belt to ascertain it's mechanical integrity real time.(xi) Hoist way Access Prevention Special Safety Feature to prevent the elevator from operating after landing door is opened. (xii) The manufacturer have ISO 4500certification on safety norms and necessary certificates to be produced.
Note for item No. 87.0 & 88.0 :- 1. Lift Well / Shaft Size : Approx 1900 mm (W) x 1900 mm (D), Pit Depth :1600 mm, Clear Door Opening : 800 mm (W) x 2000 mm (H) for 08 Passenger Lifts (544 Kg) and Shaft size 2100mm x 2300 mm and pit depth 1600 mm, for Goods lift (1000 Kg) 2. Contractor shall take care of all safety measures and all safety precautions to be followed by the staff and the same to be ensured by contractor. 3. Any addition / alteration cost required including all civil works like breaking of PCC, Plastering, New PCC, RCC etc to be carried out by the contractor.
Note for Item No. 87..0 & 88.0 ( Contd/-) 4. The following items shall be provided and the unit rate quoted above shall be inclusive for the same . (a) Gearless Electric motor, AC, 3 phase, 415V, 50Hz of suitable capacity including necessary cabling with ISI marked FRLHS Cable and fire resistant conduits as required. (b) Standard Wall / Floor mounted Lift Control Panel Board with suitable capacity 4 pole RCCB as incomer. (c) Mechanical guide rail in 'T' section with tongue and groove arrangement for smooth operation of car and counter weight. (d) Type of operation shall be single automatic push button type . (e) Minimum 4 Nos SS Finish 3W LED Fittings connected to Inverter supply and 02 Nos Blower Fan with Switch in lift car.
Note for Item No. 87..0 & 88.0 ( Contd/-) (f) Minimum 10 Nos 7/9W LED Bulk Head Fittings for lift well lighting and 10 Nos 5Amps Plug Point incl point wiring with 1.5Sqmm FRLHS cables and control switches. (g) Type of signal system - Hall button with digital hall position indicator, digital car position indicator in car fixtures in stainless stell face plates. (h) Capacity of ARD battery (High Amp Hour) should be suitable to perform minimum three continous rescue operation. (l) All necessary Grouting Plates / Bolts, Nuts, bolts, washers etc. (j) Provision of hoist way and governors rope and governor. (k) Provision of new buffer spring as per manufacturers design. (l) Provision of battery operated alarm and emergency light through inverter of suitable capacity having power back up for a period of minimum 30 minutes . (m) Drive - Permanent Magnet Gearless Machine frame fixed in the machine room. (n) Progressive type and bydirectional Over speed governor monitors the speed and triggers safety gears etc shall be installed in the machine room.
Note for Item No. 87..0 & 88.0 ( Contd/-) (o) Necessary scaffoldings in lift well. (p) Pit Ladder. Safety Measures:- (i) Overload relays. (ii) BMS Compatibility / Potential Free Contactors (Emergency Stop / Opening, Direction Up / Down, Failure, Main mode etc. and fuses. (iii) DO /DC Button and NS Button.(iv) High Quality Electrical Terminals / Sockets.(v) Limit switch with accessories on each doors / cage.(vi) Gravity / counter weight limit switches for top most position.(vii) Break Magnet of suitable size with manned released arrangements.(viii) Reverse Phase / Phase sequence corrector. (ix) lift door should be minimum 2 Hrs. fire resistance as specified in IS-14665.(x) Automatic condition monitoring of Polyurethane - Coated Steel Belt to ascertain it's mechanical integrity real time.(xi) Hoist way Access Prevention Special Safety Feature to prevent the elevator from operating after landing door is opened. (xii) The manufacturer have ISO 4500certification on safety norms and necessary certificates to be produced.
Kanika Construction Company
UBC Engineers Pvt Ltd
RENJIN CONSTRUCTION
SHELL REFRACTORIES and INSULATIONS
SOOD ASSOCIATES PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid