Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC NOT FOUND | L1 | Accepted-AOC OK | |
| 2 | L2₹12.5 L+₹1.1 L (9.50%)Rejected-AOC 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-AOC OK | |
| 3 | L3₹18.9 L+₹7.5 L (65.7%)Rejected-AOC 62 KRISHNA CHAMBERS PHASE III AMRITSAR | AMRITSAR | AMRITSAR | PUNJAB | L3 | Rejected-AOC OK |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
22 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
CWE AF BHISIANA
CWE(BHI)/SIR-26/2022-23
2022_MES_540951_1
CWE(BHI)/SIR-26/2022-23
Open Tender
Civil Works
Item Rate
180 days
AF Sirsa
AS PER COVER 1
6 documents required · 6 mandatory
₹500
Yes
GE AF Sirsa
₹50,000
Yes
29 Sept 2022
26 Jul 2022
24 Aug 2022
26 Jul 2022
22 Aug 2022
10 Aug 2022
26 Jul 2022 - 2 Aug 2022
60 days
Amount
Excavation in trenches manually not use a JCB not exc 1.5 m wide and not exceeding 1.5 m depth for foundation laying of cables etc and getting out in soft loose soil all as specified and directed.
Returning filling including spreading leveling watering and well ramming in layers n.exc 25 cm in soil completed all as specified and directed.
Removing excavated material n.exc 50 m and depositing where directed at a level n.exc 1.5 mtr above the starting point as in soil complete all as specified and directed.
M&L sand cushioning (dry) in trenches/ducts for protection of UG cables( below,above and around the UG cable laid) of 23 cm spread thickness (8 cm in depth before laying the cable aabd 15 cm in depth after laying the cable ) and cosolidated( punned) up to 180mm thickness complete all as specified and as directed.NOTE:-For the purpose of payment,punned thickness of sand cushioning only will be measured.
M&L for cable protection GI Tubing light grade fixed long the pole/under road of 80mm bore size
M&L for Fault detectection UG Cable by using cable fault detector/locator vehicle mounted to a acuuracy of 2 mtr for various location of any size up to length of 400 RM and type upto 11 KV NOTE- (i) After location the fault the rectification of the fault is the sole responsibility of the contractor (ii) The cable straight through joint/ end termination will be measured and paid seperately in relevant itms
S&F of 33/11Kv HT side bushes of 2 MVA transformer all as specified
S&F of 33/11Kv LT side bushes of 2 MVA transformer all as specified
S&F SF-6 Gas allas specified and directed
S&F Oil winding temp gauge of 2 MVA Trasformer all as specified
M&L for Toping up of the Transformer and New with T/Oil having dielectric strength not less than 40Kv Make- Power/Powerking
Material and Labour for painting to Panels HT/LT and HT feeder panels/Piller Box any size installed at all AOR with two coats of super enamelled paints of approved colour with spray painting machine incl prepration of surface complete all as specified and directed.
M&L for Painting to Transformer Rating upto 750 KVA , outdoor/indoor type, installed at diffrent loaction of sub station incl mounting channels and connected accessories with two coats of super enamelled paints of approved colour with spray painting machine incl prepration of surface complete all as specified and directed.
S&F of Aluminium strip of 50x12mm size including bending and fixing at the terinals of transformer LT side whereever directed for connection the outgoing cabled lugs of diff sizes all as directed
Repair and Replacement of current Transformer moulded in epoxy compound with dual ratio 100/20/5 Amps complete connection with Auto wire 2.5sqmm including bending as existing in VCB at site
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised strip of 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion
Taking down the defective/Unserviceable Transformers from existing site from pole/Sub station/Plinth with the help of man power or chain pully block or by Crane etc including disconnecting all electrical and mechanical connections from the site and carrying to workshop for repir and replacment of old burnt u/s items as well as winding etc including transporting of capacity up to 100 KVA or all as per directed by Engg-in-Charge.
All as per srl item No 17 here in before but 125 KVA to 250 KVA (incl 250 KVA)
All as per srl item No 17 here in before but 315 KVA to 415 KVA (incl 415 KVA)
All as per srl item No 17 here in before but 500 KVA to 750 KVA
M&L for opening Dismantling transformer capacity upto 415 KVA by lifting the top cover for taking out the HT/LT core and draining out the transformer oil in clean barrel including cleaning the transformer chamber body inside and outside with emery paper aftre that checked all the winding and other wornout parts such as Ht/LT coils silcon stamping and other connected items like tap changer, breather assembly, explosion tube with diafram, connector tank, etc and complete and Reassembling the transformer LT/HT connection after proper De- hydration, Reconditioning and Testing of transformer after reassembling complete on Noload at wkshop and on load testing at site and all as specified and directed Note- (i) Job includes the cost of gasket set, LT/HT bushes, nuts , bolts, washers etc required for the complete the Job (ii) After refixing of trnasformer, Testing of transformer will be based on partial load and full load, incl entire painting of transformer with super enamelled paint, deemed in quoted rates by contractor. (iii) Unserviceable transformer should be rewinding in workshop within a week time frame on reaching at the wrkshop, after failing a penalty will be imposing to contractor as per IAFW-2249 of contract agreements (iv) Transportation of transformer upto workshop and back to site will be complete resposbility to the contractor, and No other charges will be paid to contractor for transportation. (v) Dehydration & filteration of Transformer oil paid separately in concern item
All as per srl item No 21 here in before but 500 KVA to 750 KVA
All as per srl item No 21 here in before but 2 MVA
M&L for replacement of LT bushings with brass terminal, brass nuts and washers, gaskets, insulator etc suitable for 63KVA to 160KVA transformer complete all as specified and directed.
All as per item No. 24.00 here-in-before but of capacity 200 KVA to 400 KVA.
M&L for replacement of disc type insulator porcelin vitreous 145 mm high and 255 mm dia ball and socket type white brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts compltete all as specified and as directed.
S&F in replcament of vertical type switch air break gang operated switch triple pole mechanicaly operating mounted on insulator and steel frame with operting mechanism worked from ground level for current rating up to 400 Amps and working pressure of 11000 volts grade consisting of 4 insulator per pole with 25 mm dia GI medium grade operating handle and locking arrangement fixed with down rod operating brackets all as specified and directed by Engg-in-charge.
M&L for replacement of Lightening arrestor expulsion type complete with all fittings, transmission class, discharge capacity 65 KA, suitable for 33000 volt grade complete all as specified and directed.
M&L for replacement of danger notice board/plate of 1.6 mm thick mildsteel sheet vitreous enameled white with letter figures and conventional skull and bones in signal red colour and fixed with MS clamps,nuts and bolts of approved size of HT 25X20cm size complete all as specified and as directed
M&L for replacement of Drain plug of Transformer complete all as specified and directed.
M&L for De-hydration and filtration of transformer oil by using dehydration and filtration plant, heating and filtration of oil to be carried out till the di-electric strength reaches 50 KV to 55 KV withstand for one minute is achieved for any capacity of transformer complete all as specified and directed.
M&L for replacement of winding of transformer/dimmer state with appropriate gauge suoerena meked copper wire for transformer 63 KVA to 750KVA,11KV,3phase complete all as specified and as directed.Note with guarantee of 01 year from repairing date
M&L for replacement of breather assembly complete with silica gel for transformer 100 KVA to 250 KVA of any make, type and capacity or make complete all as specified and directed.
All as per item No. 33.00 here-in-before but of capacity 315 KVA to 400 KVA.
M&L for replacement of silica gel for (blue colour) transformer of any make, type and capacity or make complete all as specified and directed.
M&L for replacement of Dial type temperature gauge 0 to 1000 degree centigrade range complete suitable for any Make, Type and Capacity of transformer complete all as specified and directed.
M&L MS work as posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary Pentaing ,drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165
M&L for Disconnecting & Taking down/out unserviceable HT XLPE Cable 11 KV of size 70 Sqmm to 120 Sqmm 3 core of any description from Trenches, Floors, Walls, GI Pipes, etc., seggrating Serviceable Cables, Pipes, Bricks, etc. including keep in Safe Custody for re-use and unserviceable Cable removing to and depositing at E/M STORE YARD, complete all as specified and as directed. NOTE : (i) Any damage/punchred into HT cable the contractor will be responsible. (ii) Before Laying meggaring the complete cable (iii) Any damage of HT cable the contractor will be responsible. The contractor will have to supply new cable of same size and specification in liew of old cable without any extra cost.
Relaying XLPE Under Ground Cable (Serviceable Cable obtained from Item No. 38.00 here-in-before) 11000 Volt grade, Cross sectional area 70 Sqmm to 120 Sqmm, 3 Core including Testing, complete all as specified and as directed. Cable straight through joint/ end termination will be measured and paid seperately in relevant itms
M&L for replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured (Earthed), electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 Sqmm 3 core complete all as specified and as directed.Note:(Cable jointed shall be measured and paid separately)
All as per item No. 40.00 here-in-before but of size 120 Sqmm 3 core.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for indoor type & termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm Including testing on completion complete all as specified and as directed.
All as per item No.42.00 here-in-before but of size 120 to 185 Sqmm 3 core.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm Including testing on completion complete all as specified and as directed.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sqmm Including testing on completion complete all as specified and as directed.
M&L for replacement of Cable jointing kit for 11 KV (Earthed) grade cable for staright through Joints cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 to 95 sqmm Including testing on completion complete all as specified and as directed.
All as per item no 46.00 here-in-before but of size 120 to 185 Sqmm.
M&L for replacement of Supply and laying un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm complete all as specified and directed.
M&L for taking out old precast concrete cable cover of any type and any size and relaying serviceable precast concrete cable cover complete all as specified and as directed.
M&L for making of bore to road link width for providing GI Pipe upto110mm dia for passing armoured cable complete all as specified and directed.
M&L for replacement of Galvanised Steel Tubing Pipe 80mm bore (dia), light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable size Mild Steel Flat Iron Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
M&L for replacement multi function meter LCD display type of capacity of auxilary supply 175-265 V AC Voltage measurement 20-300 V AC (L-N)/35-485 V AC (L-L) with parameters rangeVolt,Amp,Frequency,Powerfactor,KW,KVA,KVAR,KWh,KVAh,KVARh,Runhours,On hours,Phaseangle,Interrupts,THD,Events(High-low),neutral currents with RS-485 including wiring required at site complete all as directed.
M&L for replacement and posting of electrical insulating mat 2.5 mm thick madeout of dilectric elastomer which process elastic properties and may be neutral or synthetic in nature.Should have working voltage-11 KV Notear or breakage due to Trolley movement & foot traffic resistant to acids,alkalis,solvent and transformer oil,pasteable type can be easily pasted/installed on floor water and moistureproof complete all as specified and as directed.
All as per item no 53.00 here-in-before but 3.0mm thick for 33 KV
M&L for scrapping /cleaning of outer surfaces of transformer 63KVA to 400 KVA capacity of an Make/Shape/Size completely and spray painting with two coats of best quality synthetic enamel paint over one coat of redoxide primer complete including writing of MES No. all as directed by Engineer-in-charge.
M&L for replacement of cement concrete 1:2:4 (20 mm graded stone agregrade) 1:2:4 around the LT/HT Poles/BUS Bar/LT Panel/Path,15 cm thick complete all as specified and as directed.
S&F of Buchholz Relay for 100 KVA to 400 KVA of Transformer including pressure guage should be sturdy construction and resistance to corrosion as per IS Specification all as specified and directed by Engr-in-charge
S&F Oil winding Temperature Indicator, double needle type , as per on site Transformer upto 750 KVA as per IS Specification all as specified and directed by Engr-in-charge
S&F Oil level indicator for all type of Transformer all as specified and directed by Engr-in-charge
VERMA BROTHERS
NATIONAL CONSTRUCTION COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .