Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
4 Sept 2023, 2:00 pmClosed
Executive Engineer ED Kathua
ED Kathua
Creation of 100KVA Substation along with HT LT Line at Tehr, Berli, Dewal Tilla, Dadwara, Bhaddu I and Bhaddu II under water supply scheme JJM PHE in respect of Electric Sub Division Billawar, ED Kathua
2023_PDD_226341_1
KED 14 of 2023 24 Dated 14.08.2023
Open Tender
Electrical Works
Turn-key
60 days
ED Billawar
Refer to Tender Dovoument
4 documents required · 4 mandatory
₹1,000
Executive Engineer ED Kathua
₹93,000
6 Oct 2023
14 Aug 2023
6 Sept 2023
14 Aug 2023
4 Sept 2023
14 Aug 2023
14 Aug 2023 - 4 Sept 2023
Amount
Creation of 100 KVA Sub Station at Berli under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etc of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long ST pole (ST-410 SP 33)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution box for 100 KVA DTR with MCCB for incommer & SFU's for outgoing ckt
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole
Painting of poles Red oxide
Painting of poles Alumunium oxide
Erection of HT line on 9 Mtrs. ST poles with ACSR Weasel Conductor at Berli under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etc of the following material:
9 Mtr. Long ST pole (ST-410 SP 33)
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Red oxcide Paint
Aluminium Paints
Cement Bottoming 1:2:4 mix as per REC Standrad 0.5 CUM per pole
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT line on 8 Mtrs. ST poles with ACSR Weasel Conductor 3 Phase 4 wire at Berli under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etc of the following material:
8 Mtr. Long ST pole (ST-410 SP 15)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
Erection of 11 KV Tapping point at Berli in respect of JPDCL Electric Sub Division Billawar, on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long ST Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
30 mm² ACSR Weasel Conductor
PG Clamps for 30mm2 ACSR conductor
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
Creation of 100 KVA Sub Station at Dadwara lower under water supply scheme JJM in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole(WL-300 Kg )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 100KVA DTR with MCCB for incomer & SFU's for Outoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottoming 1:2:4 mix as per REC standerds .5 Cum/pole
Sundary items like Aluminium Lugs, Jumpers , binding tape
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Dadwara under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT line on 8 Mtrs.PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at Dhadwara under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
8 Mtr. Long PCC pole (PCC WL-200 KG)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Ston pad(300mmx300mmx75mm)
Erection of 11 KV Tapping point at Dadwara under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
30 mm² ACSR Weasel Conductor
PG Clamps for 30mm2 ACSR conductor
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
Creation of 100 KVA Sub Station at Dewal Tilla under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² (2 CKt) Cable, 1.1 KV grade PVC insulated stranded conductor FRLS type
9 Mtr. Long pole (PCC WL -300 KG)
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. ( 4 Nos for Transformer and 1No. for Panel)
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 100 KVA DTR with MCCB for incommer and SFU's for outgoing Ckt
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate witrh clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottomiing 1:2:4 mix as per REC standerds .5 Cum/pole
Sundary items like Aluminium Lugs, Jumpers , binding tape
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Dewal Tilla under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT line on 8 Mtrs. PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at Dewal Tilla under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
8 Mtr. Long PCC Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti climbing Devices with Clamp
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Aluminium Jointing Sleeves
Creation of 100 KVA Sub Station at Tehr under water supply scheme JJM in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole(WL-300 Kg )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 100KVA DTR with MCCB for incomer & SFU's for Outoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottoming 1:2:4 mix as per REC standerds .5 Cum/pole
Sundary items like Aluminium Lugs, Jumpers , binding tape
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Tehr under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long PCC Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT line on 8 Mtrs. PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at Tehr under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
8 Mtr. Long PCC Pole(PCC WL-200Kg )
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Weasel Conductor
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti climbing Devices with Clamp
Earthing Complete bu GI Pipe 40mm or GI rod 20 mm 2.5 Mtr long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Aluminium Jointing Sleeves
Erection of 11 KV Tapping point at Tehr under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
30 mm² ACSR Weasel Conductor
PG Clamps for 30mm2 ACSR conductor
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
Creation of 100 KVA Sub Station at Bhadu-I under water supply scheme JJM in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long PCC Pole(WL-300 Kg )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 100KVA DTR with MCCB for incomer & SFU's for Outoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottoming 1:2:4 mix as per REC standerds .5 Cum/pole
Sundary items like Aluminium Lugs, Jumpers , binding tape
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Bhadu under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT line on 8 Mtrs. PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at Bhadu-I under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
8 Mtr. Long pole (PCC WL-200 KG)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Ston pad(300mmx300mmx75mm)
Erection of 11 KV Tapping point at Bhadu-I under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
30 mm² ACSR Weasel Conductor
PG Clamps for 30mm2 ACSR conductor
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
Creation of 100 KVA Sub Station at Bhadu-I under water supply scheme JJM in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
11/0.433kV, 100 KVA, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Al wound ) up to 200 KVA, copper Wound and with LV Cable Box having detachable Aluminium Gland plate.
Gapless Surge Arrestor,9 kV ,10 KA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
70 mm² (1Ckt) Single Phase Cable,1.1K V Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole(WL-300 Kg )
11KV Polymeric composite Disc Insulator 12kV,min failing load 45KN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps for L.A set/G.O set/Horn Gap
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Distribution Box for 100KVA DTR with MCCB for incomer & SFU's for Outoing circuits
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedege connectors /PG clamps
Danger plate with clamps
GI Barbed wire for ani Clambing
3 Ph 4 Wire Trivector meter with CT
Cemetn bottoming 1:2:4 mix as per REC standerds .5 Cum/pole
Sundary items like Aluminium Lugs, Jumpers , binding tape
Erection of HT line on 9 Mtrs. PCC poles with ACSR Weasel Conductor at Bhadu under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long Pole(WL-300 Kg )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel x-arm includingclaps and braces
30 mm² ACSR Weasel Conductor
PG Clamps for ACSR weasel conductor
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamp
Anti Climbing Devices with clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Stone Pad (300mmx300 mmx75mm)
Aluminium Jointing Sleeves
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Laying of LT line on 8 Mtrs. PCC poles with ACSR Weasel Conductor 3 Phase 4 wire at Bhadu-I under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
8 Mtr. Long pole (PCC WL-200 KG)
GI U-Clamp for Shackle insulators
Shackle insulator 16 KN
30 mm² ACSR Conductor
Galvanized Nuts and Bolts
Danger plates
Anit Climbing Device with Clamps
Earthing Complete by GI Pipe 40mm dia or GI Rod 20mm ,2.5 mtrs long through GI Strip
Ston pad(300mmx300mmx75mm)
Erection of 11 KV Tapping point at Bhadu-I under JJM Scheme in respect JPDCL Electric Sub Division Billawar on Turnkey Basis by way of supply,Erection/Installation,Testing commissioning etec of the following material:
9 Mtr. Long Pole(ST-410 SP-33 )
GI V cross-arm/Horizontal with top Bracket including clamp
GI Channel/ angle iron including Clamps
11 KV GO , AB switch 3 phase , 3 pole , 200 amp vertically type
30 mm² ACSR Weasel Conductor
PG Clamps for 30mm2 ACSR conductor
11kV Polymeric composite Pin Insulator 12KV5kN, Lighting Impulse 75KV Positive and 80KVNegative, creepage distance 320mm
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75KV Positive and 80KV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Cement bottoming 1:2:4 Mix as per REC Standars
Aluminium Paint
Red oxide paint
M/S SUKRALA ELECTRICAL WORKS
JAI CHANDI MAA ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .