| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5,100Same as L1Rejected-Finance | L2 | Rejected-Finance EMD Refunded | |
| 3 | L3₹5,100Same as L1Rejected-Finance | L3 | Rejected-Finance EMD Refunded |
Tender Value
₹2.4 L
EMD Value
₹5,100
Closing Date
21 Jun 2022, 1:00 pmClosed
ATUL BHARDWAJ
Hauz Khas
Improvement of electrical installation of Community Centre Mehrauli, in Ward No. 68S under South Zone.
2022_SDMC_119027_1
EE/Elect/SZ/2022-23/11
Open Tender
Electrical Works
Works
30 days
South Zone
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹5,100
10 Jan 2024
14 Jun 2022
22 Jun 2022
14 Jun 2022
21 Jun 2022
14 Jun 2022
Amount
Laying and Jointing PVC Pipe. Heading
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. Group C
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group C
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surfac/recessed steel/ PVC conduit as required.(a)3 x 2.5 sq. mm
3 x 4 sq. mm
3 x 6 sq. mm
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required.(a)5/6 amps switch
3 pin 5/6 A socket outlet
15/16 A switch
6 pin 15/16 A socket outlet
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a)Single pole
Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required. (a) 63 amps
Supply of 12" (300 mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter, blade etc as required.
Installation of exhaust fan in the existing opening ,including making good the damage ,connection,testing,commissioning etc.as required. (a) Up to 450 mm sweep
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as reqd..
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
S.I.T.C of LED Tube type Luminaire 20W rating complete with polycarbonate housing Batten integrated electronic driver prewired with high efficient LED with the following: (a) Total System wattage 20 watt +/- 5% (b) Luminous Efficacy Lumens/watt >=95 (c) power factor >= 0.95
Supply of XLPE insulated,PVC sheathed Al.conductor Armoured cable 1.1KV grade Conforming to IS 7098/1988 of following Sizes (a) 2 X10 SQmm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamp with 1 mm thick saddle).
P & F of Hot Press Sheet Moulded Compound (SMC),fire retardant (Temp. resistanceup to 200 deg.C),IP-55 weatherproof pole box of inner dimension 200 mmx160 mmx98 mm complete with suitable arrangement for fixing of 2 nos.of 6 to 32 amp single pole MCB & 63A double pole isolator (MCB/isolator excluded) with neutral link duly shorting on DIN channel with 2 nos.of MS clamps with SS back plate of suitable size with danger monogram & SDMC property printed on the cover etc. as required.
Supply of 3 mm thick phenolic laminated sheet
Supply,installation,testing & commissioning of single phase monoblock pump set complete with all accessories workable on 240/415 volts,50 Hz AC supply.(a) 1 HP (0.75 KW) Single phase pump set,head from 12-30 mtr. suction and delivery 25X25 mm.
The Electrician
shailesh kumar tyagi
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .