| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹31.8 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹32.6 L+₹58,682.15 (1.84%)Rejected-Finance | L-2 | Rejected-Finance L-2 | |
| 3 | L-3₹36.9 L+₹4.9 L (15.3%)Rejected-Finance | L-3 | Rejected-Finance L-3 | |
| 4 | L-4₹36.9 L+₹5.0 L (15.5%)Rejected-Finance RZB 69 GALI NO 5 RAJ NAGAR PART 1 WEAT DELHI DELHI 110045 SOUTH WEST DELHI DELHI 110045 UDYAM DL 10 0018772 | SOUTH WEST DELHI | DELHI | 110045 | L-4 | Rejected-Finance L-4 | |
| 5 | L-5₹42.0 L+₹10.0 L (31.2%)Rejected-Finance | L-5 | Rejected-Finance L-5 |
Tender Value
₹44 L
EMD Value
₹88,000
Closing Date
2 Mar 2024, 6:00 pmClosed
GE (AF) FARIDABAD
GE (AF) FARIDABAD
ADDN/ALTN TO HQ CWE (AF) GURGAON OFFICE AND CERTAIN E/M WORKS IN AOR OF GE (AF) FARIDABAD
2024_MES_640198_1
GE (FBD)/AF-69/2023-2024
Open Tender
Civil Works
Item Rate
180 days
Faridabad
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) FARIDABAD
₹88,000
Yes
9 Apr 2024
1 Feb 2024
4 Mar 2024
1 Feb 2024
2 Mar 2024
17 Feb 2024
1 Feb 2024 - 8 Feb 2024
Amount
Demolition of Brickwork or stone/ boulder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but including ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed by Engineer-in-Charge.
M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as per item No 02 above but except bricks.
M&L for brick work with sub class ‘B’ bricks (old size brick) straight or curved on plan to any radius in half bricks thick walls, built in CM 1:4 complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L, Rendering 10 mm thick in CM 1:3 on of brick work or concrete surface finish even and smooth w/o using extra cement incl WPC @3% by weight of cement complete all as specified and directed by Engineer-in-Charge
M&L, Rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish even and smooth w/o using extra cement incl WPC @3% by weight of cement complete all as specified and directed by Engineer-in-Charge
M&L, Rendering 05mm thick in CM 1:3 on of brick work or concrete surface finish even and smooth w/o using extra cement incl WPC @3% by weight of cement complete all as specified and directed by Engineer-in-Charge
M&L for Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm on new surfaces and obtain smooth finish using sand paper complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of new plastered surface and applying three coats of white wash on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M & L for preparation of old surfaces by removal of existing treatmen and applying three coats of white wash on ceiling over one coat of primer etc complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new plastered surface and applying on walls/ceiling and applying two coat of plastic emultion paint and applying one coat of wall care putty for complete smooth surfce complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces on walls/ceiling surface obtain smooth finish using sand paper incl complete removal of existing treatment and apply on wall/ceiling etc and applying two coats of plastic emulsion paint over a coat of acrylic primer incl one coat of wall care putty for smooth surface as per manufactures instruction , complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of old surfaces on walls/ceiling surface obtain smooth finish using sand paper incl complete removal of existing treatment and apply on wall/ceiling by comp, roof boarder, drops, fins, chajja / roof facia, column etc and applying two coats of exterior emulsion paint over a coat of acrylic primer as per manufactures instruction ,complete all as specified and directed by Engineer-in-Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store yard and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L for non skid ceramic coloured tiles joint free 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,over and including 15 mm thick bedding layer or screed bed in cement mortar (1:6) in floors etc complete all as specified and directed by Engineer-in-Charge.
M&L for Glazed ceramic colour tiles joint free in vertical surface350x250x7/ 450x350x 7 mm thick set andjointed in neat cement slurry and pointed in white or colour cement to match with tiles including 10mm thick rendering in CM (1:4) backing of wall tiles such as dado/skirting in vertical surface etc complete all as specified and directed by Engineer-in-Charge. Note : shade & design as approved by GE.
M&L for vitrified tiles 9 to 10mm thick (square/rectangular) polished, area of each tiles exc 0.42 sqm but not exc 1.00 Sqm in floors, skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM (1:4) for laying floor finishes having ulta/double charged/HD Vitrified tiles complete all as specified and directed by Engineer-in-Charge.
M&L for Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.36 sqm but n exc 0.42 sqm, in floors, dado , skirting etc. set and jointed in neat cement slurry over and including 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match complete all as specified and directed by Engineer-in-Charge.
M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for Granite 18-20mm thick (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding ,rounding of edgeing and dismantling complete all as specified and directed by Engineer-in-Charge.
M&L for Mirror polishing on marbel/granite/Kota stone/stone work where even required to give high gloss finish complete all as specified and directed by Engineer-in-Charge.
Taking down chowkahts or frames with shutters (without taking off shutters from the frame) exceeding 1.5 Sqm but not exceeding 4 sqm each complete all as specified and directed by Engineer-in-Charge.
M&L for factory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with mild steel square tube, supplying and fixing in opening as per specification & drawing and complete all as specified and directed by Engineer-in-Charge.
S&F for Factory Made Solid PVC Moulded Door Shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC sheet on the front face & 2 mm thick prelam PVC sheet on back side, supplying & fixing in frame at site as per specification & drawing and as directed by Engr-in-Charge.
M&L for aluminium Anodized powder coated fixed frame of partiton or fixed window / ventilator , aluminium section weighting not less than 0.55kg/RM incl 4.8mm thick sheet glass oridinary quality ' frosted glass or ACP sheet joining with rubber beading , aluminium snap beading complete all as specified and directed by Engineer-in-Charge.
S&F aluminium wire guard mesh of 4mm nominal dia of wire and average width of aperture 75 - 85mm and fixed with aluminium frame / staples complete all as specified and directed by Engineer-in-Charge.
M&L for 4.8 mm thick float glass ordinary quality' frosted glass and glazing with aluminum beeding and gasket to aluminum framework in square exc 0.50 sqm in each pane in repair complete all as specified and directed by Engineer-in-Charge.
Easing andAdjusting aluminium door and window including refixing beading after replacement of defective portions such as door closer, aluminium handles, hinges, locks, new rubber gasket, aluminium beading, preleminated prarticle board, sheet glass etc ccomplete all as specified and directed by Engineer-in-Charge. Notes : Door closer, door spring, aluminium beading, rubber gasket, aluminum beading, prelaminated particle board, sheet glass shall be measured and paid separately under respective item of schedules.
S&F of floor door spring etc complete all as specified and directed by Engineer-in-Charge.
S&F of door closer hydraulically regulated design No 2etc complete all as specified and directed by Engineer-in-Charge.
S&F of Mortice lock vertical type 4 lever etc complete all as specified and as directed etc complete all as specified and directed by Engineer-in-Charge.
S&F of Neoprene/EPDM Rubber gasket for fixing aluminium door and window shutters etc complete all as specified and directed by Engineer-in-Charge.
S&F of aluminium beading for fixing of aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
S&F of 150 mm long aluminium tower bolts for aluminium door and window shutter etc complete all as specified and directed by Engineer-in-Charge.
M&L for 18mm thick water proof solid Action Tesa Violet coated High Gloss and highly scratch resistant panels of approved shade fitted with necessary arrangement as in Office cabinet back sides, partition, shutters and shelves, etc., fixed with stainless steel screws/ brackets with special type seprate locking arrengments of each lockers to exposed sleves , complete all as specified and directed by Engineer-in-Charge.
S & F for 30 mm Continuous (piano) hinges, mild steel, bright finish or electro galvanised complete all as specified and directed by Engineer-in-Charge.
S&F for Magnetic catcher suitable for kitchen cabinet shutters, complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm Hasp and staple, safety type, brass with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engineer-in-Charge.
M&L for WPC Louvers of 3 to 4 mm in thick for wall/ celings/ in flute pattern for fixing of profile lights with including special type screws , fastners and necesarry frame works for celing using GI Channels frame work, designed decorated veeners on backround of WPC Louvers size (2400 x 1200) mm any colour/design , inclusive of its all frame work L Corner, moulding end caps and necessary frame work for fixed and screws as required at site including dismantling of old wall panelling / false celing complete all as specified and directed by Engineer-in-Charge.
S&F 10 to 12 mm thick toughned glass Partition/door with holes and necessary steel hinges incl steel handles not less than 300 mm long on both sides of door, incl necessary locking arrangement and black film on glass complete all as specified and directed by Engineer-in-Charge.
M&L for one light/fan/exhaust fan point wiring controlled by one switch with PVC insulated unsheathed multi stranded copper conductor (FRLS) of size 1.5 Sqmm (for Phase colour code Red and for Neutral colour code Black) and one run of size 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor (FRLS) (as earth wire, colour code green) and connected to common earth dolly all as specified. , drawn through in and including concealed PVC Conduit medium grade, ISI marked 20 mm dia along with conduit fixing accessories and with pressed steel terminal box thickness 1.6 mm painted with one coat of black bituminous paint as a primary and two coats of enamel paint with 3 mm thick laminated sheet for provision of switches/regulators as per specified SSR and as directed by Engineer- in- Charge. NOTE:- After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No 42 above but 5 Amp socket outlet, independent.
All as per item No 42 above but on the same board.
All as per item No 42 above but 2.5 sq mm wire for one 15 Amps socket outlet independent with continuous PVC insulated single core green colour copper earth wire of size 1.5 sq mm connected to common earth dolly.
S&F modular white cover plate with frame, 3 module complete all as specified and directed by Engineer-in-Charge.
S&F modular white cover plate with frame, 6 module complete all as specified and directed by Engineer-in-Charge.
S&F modular white cover plate with frame, 8 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 3 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 6 module complete all as specified and directed by Engineer-in-Charge.
S&F Metal Flush boxes 8 module complete all as specified and directed by Engineer-in-Charge.
M&L modular switch 1 way 6 A, 1 module complete all as specified and directed by Engineer-in-Charge.
M&L modular socket, 6A-2/3 pin combined, 2 module complete all as specified and directed by Engineer-in-Charge.
M&L modular Switch 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge.
M&L modular Socket 16A, 6 pin, 3 module complete all as specified and directed by Engineer-in-Charge.
S&F modular fan step regulator, 120W -2 module complete all as specified and directed by Engineer-in-Charge.
S&F bell Multi music AC 230Volts single pole complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose,3 phase/PVC/Polycarbonate,isolated body after dismantling old one complete all as specified and directed by Engineer-in-Charge.
M&L for Recess mounted 15 Watt high efficancy recess LED slim round downlighter IP20 with high brightness LED for glare free homogenous illumination celing light complete with electronic driver complete all as specified and directed by Engineer-in-Charge.
Supply and install MCCB TPN fixed type 63 Amps rated with breaking capacity 16 KA complete all as specified and directed by Engineer-in-Charge.
Supply and install SPN enclosure including plug And socket with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
S&F exhaust fan sweep 300 mm made up of sturdy engineering plastic complete with louvers shutter , voltage 230 V , 50 Hz , 1200 RPM copper wound complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB DB TPN 6 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar WITH INCOMER AS 4 POLE MCB 240/430V for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old one complete all as specified and directed by Engineer-in-Charge.
Shifting of existing split AC 1.5 tr and re-installation complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB DB SPN 4 Way factory made IP 42 protection class metal double door with 200 Amp rating bus bar 240 for fixing of MCBs/Isolators/RCCBs etc completed after dismantling old unservicable complete all as specified and directed by Engineer-in-Charge.
S&F in replacement MCB SP 6 to 32 amps 230 Volt ccomplete all as specified and directed by Engineer-in-Charge.
Supply and install in replacement SPN enclosure including plug And socket with 16 to 32 Amp SP MCB C Curve 10 KA complete all as specified and directed by Engineer-in-Charge.
Supply , installation and testing in replacement of Energy efficient Adjustable track spotlight powder coated aluminium housing with clear glass cover for high-performance with 10 W LED 2000lm, 3000K IP20 complete all as specified and directed by Engineer-in-Charge.
S&F in replacement single pole blanking plate in the existing cover plate complete all as specified and directed by Engineer-in-Charge.
Supplying and fixing in replacement PVC conduit 25 MM dia along with accessories in surface/recess I/C or cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed by Engineer-in-Charge.
Supply and installation of PVC Duct For AC copper pipes and insulation complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of MCB SPN 32 Amps 230 Volts complete all as specified and directed by Engineer-in-Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 2 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old unsv and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 4 sqmm cable alongwith one run of 2 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 6 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old unsv and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer-in-Charge. Note : Two runs of 6 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length).
Supply and fix in replacement fan rod of length 2 to 3 feet complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches in soft/loose soil not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr depth for laying of cables/poles or foundation etc and getting out complete all as specified and directed by Engineer-in-Charge.
Returning, filling, including spreading levelling and well ramming in layers not exceeding 25cm thick complete all as specified and directed by Engineer-in-Charge.
Removing of surplus excavated soil to a distance not exceeding 50 Mtr from starting point and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushoning with a layer of sand 80mm thick before laying of cable and 150mm thick after laying of cable to trenches complete all as specified and directed by Engineer-in-Charge.
M&L for sub class `B` bricks for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade120 sqmm 3.5core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc complete all as specified and directed by Engineer-in-Charge. Note: (i) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways and Aluminium thimbles/lugs are incl in the quoted rates. (ii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
All as per item No 81 above but for 3.5 core 95 Sqmm.
All as per item No 81 above but for 3.5 core 50 Sqmm.
S&F Busbar Chamber for outdoor type 3.15 mm thick and suitable size ( 25"x25"x30") for set of 04 aluminium busbar 400 Amps rating ,supported with suitable size as per direction, each of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral, The Chamber shall be fixed 30 cm above the normal ground level complete with PCC foundation (1:2:4 ) type B2 complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with galvanized steel plate earth electrode 60cmx60cmx6mm thick surrounded by char coal and salt buried directly in ground vertically in pit of depth not less then 2.25 mtr below ground level with top edge of the earth plate at depth of not less then 1.5 mtr below ground level surrounded from all sides by char coal dust and common salt in alternate layers of 15 cm depth and earth plate electrode connected to galvanised earth lead Strip of 25x4mm at two points by means of GI nuts bolts, check nuts and washers and connected to earthling test point drawn through GI pipe 40mm medium grade for protection of earth lead wire and arrangement of watering pipe incl PCC earth pit (1:3:6) type C-2 with CI frame and RCC cover all as shown in electrical Plate No 3 on SSR Part-I including testing and dismantling ,taking down old unser earthing complete all as specified and directed by Engineer-in-Charge. Note: (i) Rate of Earth work, Earthing electrode, all connections, nut-bolts, washers, complete labour, testing, Earth lead upto 7.5 mtr, char coal dust, common salt, porcelain insulator, PCC earth Pit, CI frame ,RCC cover, funnel with wire mesh are incl in quoted rate and watering pipe, earth lead protection pipe, test poit, earth lead exceeding 7.5 mt are measured and paid separately.
Supply and install hi wall split type Air conditioner with (1.5 ton) indoor/outdoor unit complete with inverter technology , cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 ton complete all as specified and directed by Engineer-in-Charge. .Note: (i) Rate of AC Installation , all connections, nut-bolts, washers, complete labour, testing, Copper tubing ( incl both pipe size of pipe 1/2" and 1/4" ) upto 3.0 mtr with electric wire , drain pipe complete are incl in quoted rate and Copper tubing , electric wire and drain pipe exceeding 3.0 mtr are measured and paid separately.
S&F Voltage stabilizer for automatic operation single phase naturally air colled indoor type &designed for input variation between 170 volts to 250 volts with output voltage stabilized at 230 with accuracy of +-2.5% and capacity 5 KVA complete all as specified and directed by Engineer-in-Charge.
S&F single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole 20 amps MCB complete all as specified and directed by Engineer-in-Charge.
S&F of copper tubing outer dia ( 1/2" and 1/4") suitable for 1.5 TR AC including nitril rubber thermal insulation capacity ccomplete all as specified and directed by Engineer-in-Charge.
M&L for stand ( wall mounted type & Floor mounted type ) of suitable for split type AC complete all as specified and directed by Engineer-in-Charge.
M& L for PVC drain pipe complete all as specified and directed by Engineer-in-Charge.
M&L for submain wiring with 2X4.0 SQMM+1X4.0SQMM Earth Wire single core PVC insulated FRLSH sheathed copper cable connecting to common earth dolly in and including heavy duty PVC Cascing & Caping all accessories complete all as specified and directed by Engineer-in-Charge..Note:Two runs of wire shall be measured as single run
M&L for submain wiring with 2X6.0 SQMM+1X6.0SQMM Earth Wire single core PVC insulated FRLSH sheathed copper cable connecting to common earth dolly in and including heavy duty PVC Cascing & Caping all accessories complete all as specified and directed by Engineer-in-Charge.Note:Two runs of wire shall be measured as single run
Supplying ,laying and testing XLPE cable insulated screened, PVC bedded galvanized steel strip or wire armored , electric power cable (Heavy duty ) 1100 volts grade with stranded aluminum conductorof size 25 sqmm 4 core complete all as specified and directed by Engineer-in-Charge.
S & F of single pole and neutral sheet metal enclosures for Distribution board (DB's)suitable for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail 240 V, 50 Hz supply double door SP&N DB system 08 ways complete all as specified and directed by Engineer-in-Charge.
S&F MCB SPN 40-63 Amps 240V incl all termnials, fitting etc complete all as specified and directed by Engineer-in-Charge.
M & L for earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.3 mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanised means of earth wire 4 mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 15 mm dia and watering pipe medium grade of 20 mm dia and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC 1:3:6 type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion complete all as specified and directed by Engineer-in-Charge.
airstack india
SAGAR ENTERPRISES
M/S Ashoka Engineers and contractors
High Tech Metal India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .