| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹48.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹49.7 L+₹15,964.05 (0.32%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹58.0 L+₹8.4 L (17.0%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹60.7 L+₹11.1 L (22.4%)Rejected-Finance 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L4 | Rejected-Finance Not being lowest | |
| 5 | Rejected-Technical 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | - | Rejected-Technical Being two class below |
Tender Value
₹58.3 L
EMD Value
₹1.1 L
Closing Date
28 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Sachin Sharma CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO NP-07, P-37 AND NP-12 UNDER GE (NORTH) UDHAMPUR
2023_MES_605061_1
CWE/U(N)-35/2023-24
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
As per NIT
6 documents required · 6 mandatory
₹1,000
GE (NORTH) UDHAMPUR
₹1.1 L
13 Oct 2023
22 Jun 2023
4 Aug 2023
22 Jun 2023
28 Jul 2023
14 Jul 2023
23 Jun 2023 - 10 Jul 2023
Amount
Demolition of Cement Concrete of any description and in any position not otherwise specifically provided for including and disposal of unserviceable material, debris and rubbish to a distance n exc 100m complete all as specified and as directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid, bedded and pointed in any mortar complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including separation of serviceable materials from the unserviceable; stacking the serviceable materials within 100m and disposal of unserviceable material, debris and rubbish to a distance n exc 100m complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified.
Reinforced cement concrete 1:2:4, type B1 (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed.
Use and waste of form work to chullah hoods, chajjas, troughs and similar items including edgesetc to obtain rough flat finished surface of concrete complete all as specified and as directed.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes, complete all as specified and as directed.
Glazed coloured ceramic jointfree / rectified tiles 300x450mm and 7 to 8mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3, complete all as specified and as directed.
Non skid, light coloured, white printed ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white cement to match, including 15 mm thick screed bed or bedding layer in cement mortar 1:4 for laying floor finishes , complete all as specified and as directed.
Providing cement concrete 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, roof padding, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
Providing 50 mm thick cement concrete 1:3:6 type C-1 using 20mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints through out the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Treatment of sunken floor surfaces with 0.488 kg/Sqm first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then applying in second layer slurry of cement @ 0.242 Kg /Sqm mixed with acrylic based polymer based modified cementitious composite compound @0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours, including taking down old/existing treatment with wire brusing and clearing the dust and foreign material before new treatment, complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of acrylic based polymer modified cementitious composite compound or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour.
Plain cement concrete 1:5:10, type E-2 using 40mm graded brick aggregates as in sunken floor/ foundatiom, complete all as specified and as directed .
Plain cement concrete 1:2:4 type B-2 (using 40mm graded crushed stone aggregates) as floor/foundation/roof top complete all as specified and as directed.
Water closet (Squatt pattern) including lime concrete bedding, vitreous china long pan orissa pattern 580x440mm, white with integral foot rests (excluding flushing cistern & flush pipe) fixed in repairs complete all as specified.
Vitreous China wash down water closet pan and seat cover (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc., fixed in repairs complete all as specified and as directed.
Cutting holes into or through brick walls exceeding half brich but not exceeding one brick, built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed.
25 mm thick, Plain cement concrete 1:2:4 type B-0 using 12.5mm graded crushed stone aggregates as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement, complete all as specified and as directed.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision including 32mm dia PVC flush pipe, fixed in repairs, complete all as specified and as directed.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware fixed in repairs complete all as specified and as directed.
Chromium plated, 15mm Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed, complete all as specified and as directed.
Soap tray, stainless steel, as per sample fixed with wooden gutties and screws to wall surfaces, complete all as specified and as directed.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed.
PVC connections 15 mm size with PTMT nuts of length 450 mm and washers, complete all as specified and as directed.
Dismantling cast iron pipe or PVC pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100mm complete all as specified.
110mm bore, PVC (SWR) pipes, single or double socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and as directed.
75mm bore, PVC (SWR) pipes, single or double socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and as directed.
110 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all specified and as directed (ISI Marked)
PVC SWR branch piece, single (single Y/T) equal or unequal 110 mm size fixed with joint sealent etc complete all specified and as directed
75 mm bore PVC SWR bends any radius with acess door and fixed solvent etc complete all specified and as directed (ISI Marked)
PVC SWR branch piece, single (single Y/T) equal or unequal 75 mm size fixed with joint sealent etc complete all specified and as directed
20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including cutting and mirror finish polishing over and including 20 mm thick screed bedding / backing layer in CM 1:3, complete all as specified and as directed.
Dismantling water tank of capacity exceeding 250 litres but not exceeding 500 litres each and removing from site /to store, complete all as specified and as directed.
Rotational moulded polyethylene water storage tank, (white colour) three layers, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 1000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 20mm/25mm (Minimum weight 210 gram) etc), complete all as specified and as directed.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing from site, complete all as specified and as directed.
15 mm bore steel water tubing medium grade galvanised with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and as directed.
20 mm bore steel water tubing medium grade galvanised with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete complete all as specified and as directed.
Bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle screwed down for iron pipe or for brass ferrule for bore of pipe 15mm, fixed in repair, complete all as specified and as directed.
Chromium plated shower roses with arm 15mm size 195mm long with bend of 45 degree with flange including taking down the existing UNSV shower of any type complete all as specified and as directed.
Angular stop cock/Angle cock with wall flange, brass, chromium plated, screwed down for iron pipe or for brass ferrule for bore of pipe 15 mm, fixing in repair, complete all as specified and as directed.
Stop valves, fancy type chromium plated with long shank concealed type, cast copper alloy, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions of bore 15mm, fixed in repairs, complete all as specified and as directed
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm, fixed in repairs, complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed.
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4, finish surfaces even and smooth without using extra cement, complete all as specified and as directed.
Applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick layer of wall care putty including preparation of new plastered / unplastered surfaces of wall, complete all as specified & directed.
Preparation of surfaces by complete removal of existing treatment from old decorated plastered/ unplastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of primer and 1 mm thick a layer of wall care putty on walls to give uniform surface, complete all as specified & directed.
Preparation of new plastered surfaces of wall and applying three coats of white wash / colour wash on wall, complete all as specified and as directed.
Preparing of plastered / unplastered old surfaces of ceiling by brooming down or steel wire brushing, scrapping down smoke soots, moulds, efflorescence salt, treading oil, greasy spots etc, and applying two coat of white wash complete all as specified and as directed.
15 mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:4 mixed and finished even and smooth without using extra cement including scaffolding arrangment as per site requirement upto (G+3 story), complete all as specified and as directed.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of chalk whiting including scaffolding arrangment as per site requirement upto (G+1 story), complete all as specified and as directed.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3 and finish the surface even and smooth without using extra cement, complete all as specified and as directed.
Preparation of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and as directed.
Sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including waste coupling and waste pipe & bedding in CM to dwarf wall or including fixing cantilever brackets size 25x25x4mm thick and connecting union to pipe overall size 915mmx460mm bowl size 410mmx330mm x160mm, fixed in repair, complete all as specified and as directed.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed.
Description all as per item No 59 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm prelam colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing, complete all as specified and as directed.
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or gorged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Factory made (box type) mild steel window / ventilators glazed and gauzed combined shutters with side hung including box type pintol hinges, steel peg stay, locking arrangement with glazing & gazing bars dovetailed or welded and one shop coat of red oxide primer complete all specified and directed. Note : i) The ventilators shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately. iii) One side out to out dimensions shall be measured for payment of combined window (glazed & gauged).
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint, complete all as specified and as directed.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
5mm frosted / tinted sheet glass, ordinary quality and glazing with suitable rubber EPDM packing for aluminum doors / windows / ventilator and fixed frame in square / rectangular exc 0.5 sqm in each pane, complete all as specified and as directed.
Supply only water proofing compound, complete all as specified & directed.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges 100mm, lock strike plate etc. complete of frame size 105 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges 100mm, lock strike plate etc. complete of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed.
35 mm thick flush shutters, solid core construction, with block board core and ply wood face pannels, commerical type on both sides and one face is covered with decorative face veneer with lipping / frame to match polished on back side and sides of shutters complete all as specified and as directed.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
150mm long, aluminium anodised, barrel tower bolts (ISI Marked) of extruded section and fixed, complete all as specified and directed.
200mm size extruded aluminium alloy bow handles (ISI Marked), cast type., anodised, complete all as specified and directed.
300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed (ISI Marked).
Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, 140mm overall length of cover plate complete all as specified and directed (ISI Mark).
Mild steel, 150 mm, ordinary pattern helical door spring including roller and roller plate fixed to wooden or steel frames with welding/fitted with screws etc., complete all as specified.
Preparation of new wooden or wood based surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of pink primer, complete all as specified and as directed.
18/19mm thick MDF boards, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws and 6mm thick wooden beading surrounding cut portion of board, complete all as specified and as directed.
Continuous (piano) hinges width of flaps 30 mm when opened, mild steel, bright finish or electrogalvanised complete all as specified and as directed.
125 mm fancy type SS handle fixed with nut SS screws and washer, complete all as specified and as directed.
Towel rod CP brass 20mm bore and 600mm long fixed with screw and plug, complete all as specified and as directed.
Plate rack made of 1mm thick stainless steel of size 600 x 750 x 250mm including fixing as per manufacturers instruction complete all as specified and directed.
Dismantling loose/disintegrated portion of RCC chajjas, bends shelves, beams, balconies and similar work at any position or any height and dubbing out with PCC (1:1.5:3), 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrisove paint on exposed surfaced and provision of necessary support form work and including 10mm thick plastering in CM (1:4) finished fair and even, complete all as specified and as directed.
PVC (SWR) floor trap of size 75mm, with stainless steel grating including jointing to waste pipe with solvent cement, fixing in repair or CI floor trap of any type, complete all as specified and as directed.
PVC (SWR) multi floor trap of size 75mm, with stainless steel grating including jointing to waste pipe with solvent cement, fixing in repair or CI floor trap of any type, complete all as specified and as directed.
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3.50 kg/Sqm including 15mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately) and applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric APP (Atactic Polypropylene) Membrane with 100 micron high molecular high density polyethylene film. Min wt of membrane will be 3 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm complete all as specified and as directed. Note :- Water proofing treatment will be done by manufacturer of APP membrane or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed otherwise.
40mm plain Cement concrete type B-0, 1:2:4 (12.5mm aggregate) in two layer (each 20mm), in leveling course as in roof including chiken wire mesh size of 20mm X20mm and thickness of mesh 0.91 mm provide between the layer of PCC and even and smooth with false grooves at 450x450mm, complete all as specified and as directed.
Machine cut kota stone slab flooring 18-20mm thick over and including screed bed or bedding layer 15mm thick in cement mortar 1:4 laid and 15-16 mm thick and 80 mm wide white marble stone border along to wall laid and jointed jointed with grey cement slurry mixed with pigment to match the shade of the slab in floor including rubbing and polishing mirror finish complete, all as specified and as directed.
Machine cut kota stone 20-25mm thick as in riser of steps, skirting, dado and pillar laid over cement screed base and jointed with white cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and including 10 mm thick rendering in cement mortar 1:3 as in backing coat for laying wall tiles, complete all as specified and as directed.
75mm thick Plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in sub base to floor / paving, complete all as specified and as directed.
Machine pressed / vibro mechenically floated coloured interlocking cement paver block ISI marked, any shape and size conforming to IS 15658-2006 of 60mm thickness, M-35 Grade, with topping of cement with imported pigment, over and including 50mm thick layer of sand cushioning, complete all as specified directed. Note: Shape& pattern shall be approved by the GE.
Hand shower (health faucet) brass CP with 8mm dia 1 meter long flexible tube with wall hook, complete all as specified and as directed.
25 mm dia stainless steel curtain rods in repairs complete all as specified directed.
Decorative brackets for curtain rails complete all as specified directed.
Taking down carefully copper / aluminium point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse), complete all as specified and as directed.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick, and all accessories for one light / bell /exhaust fan controlled by one switch 5 Amp with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc, fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed.
Description all as per item No 99 above but for 3/5 pin 6 Amp socket outlet on the same board with other switch.
Description all as per item No 99 above but for 3/5 pin 6 Amp socket outlet on independent board.
All as per description of Serial item No 99 here-in-before but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 4 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 4 Sqmm multistrand copper conductor earth wire.
Switch piano, single pole, one way, 5 Amp, 240V, 50 Hz AC, complete all as specified and as directed.
Socket outlet, 5 Amp flush type, 240V, 50 Hz AC, complete all as specified.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, 240V, 50 Hz AC, complete all as specified.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, 240V, 50 Hz AC complete all as specified.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified.
Bell (ding dong type), AC electronic type, 230 volts, single pole, 50 Hz complete all as specified.
Switch piano flush type for bell push 5 Amps 230 volts complete all as specified.
Taking down ceiling / exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as directed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd complete all as specified and as directed.
Fixing only serviceavle light fittings any type as obtained against item No. 98, complete all as specified and as directed.
Decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 20Watt LED with integral electronic driver complete making connection and testing after fixing, fixed in repair, complete all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (2 feet length), 10 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 100 lm/W (e) System Lumens : Not less than 1000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Decorative ultra slim linear surface mounted LED lighting fixture (1 feet length), 5 Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Polycarbonate/Thermoplastic (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 90 lm/W (e) System Lumens : Not less than 450 lm (f) Colour Temperature : Not less than 6500K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.9 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 140 V- 270V (d) Operating Temperature : -10 to +50 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Street light Bracket complete made of GI pipe 25mm bore, light grade of suitable size, 1.2m long bent to shape as per site requirement alongwith MS flat iron clamps with nuts, bolts, washers including grouting the same with wall, complete all as specified.
Taking down old unserviceable copper / aluminium, submain wiring any type / size from existing and making good disturbed surfaces of wall, ceiling, floors etc to match the existing, complete all as specified and as directed.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls / roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sheet metal enclosures for distribution board when MCB to be used SPN 8 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including taking down old making good the distubed surfaces to match with existing specifications, complete all as specified.
MCB SP, 6 to 32 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 32 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified. Note: Make of MCB and DB shall of same make for all connected items.
MCB SP, 40 to 63 Amps, 240 Volts, rupturing capacity 10 KA "C" Series including providing aluminuium thimbles for outgoing cable, complete all as specified. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
Disconnecting all electrical connection from MCB DB VTPN for reconnecting the same with providing proper copper bottle lugs of suitable size and removing the burnt out MCB's complete with providing PVC flexible conduite for hanging wire, taking down and re-fixing the same position, complete all as specified.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches / pipe, fixed to poles, walls of size 50 sqmm 3.5 core, and tested, including taking up / down old unserviceable cables complete all as specified.
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 35 sqmm 3.5 core, and tested, including taking up/down old unserviceable cables complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in and getting out in any type of soil, complete all as specified and as directed.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable, punned to 18 cm thick complete all as specified. NOTE- Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches with width equal to length of brick as protection to cable, complete all as specified and as directed.
GI tubing light grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles, complete all as specified and as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No134 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
paras ram pachiala
d d builders
SHIVAE CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .