Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.3 LAccepted-AOC | 1 | Accepted-AOC L1 bidder | |
| 2 | 2₹14.4 L+₹6,280 (0.44%)Rejected-Finance | 2 | Rejected-Finance Other than L1 | |
| 3 | 3₹15.0 L+₹62,378.20 (4.35%)Rejected-Finance 110059 NEW DELHI NATIONAL CAPITAL TERRITORY OF DELHI 110059 | WEST DELHI | DELHI | 110059 | 3 | Rejected-Finance Other than L1 | |
| 4 | 4₹16.1 L+₹1.8 L (12.4%)Rejected-Finance A 93 SECTOR 36 GREATER NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201308 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201308 | 4 | Rejected-Finance Other than L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Sept 2024, 6:00 pmClosed
GE AF Tughlakabad
GE AF TUGHLAKABAD SANGAM VIHAR PO NEW DELHI 110080
REPAIR/MAINT OF COOLING APPLIANCES, REFRIGERATOR, DEEP FREEZER, RO AND WATER COOLER ALONGWITH ACCESSORIES AND MISC WORK AT AF STN TUGHLAKABAD UNDER GE (AF) TUGHLAKABAD
2024_MES_655571_1
GE/TKD-36/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF Tughlakabad
MES contractor enlisted having deposited Standing Security with dept. Contractors not enlisted in MES should meet the MES enlistment criteria corresponding to appropriate class and category
9 documents required · 9 mandatory
₹0
₹40,000
Yes
11 Nov 2024
11 Jul 2024
14 Sept 2024
11 Jul 2024
12 Sept 2024
26 Jul 2024
Amount
Disconnecting U/S burnt out rotary/reciprocating compressor from existing electric and pipe line connections of Refrigerator of 165 ltr to 270 ltr capacity of any make / location, transporting and replacing with new compressor including connecting suction and discharge lines by copper brazing, refixing capillary filter, pressure testing with the help of nitrogen gas and flushing out the oil in condensor cooling coil , establishing vaccumed for dehydration complete all as specified and as directed by Engr-in-Charge.
All as per item no. 1 above but Refrigerator of capacity 280 ltr to 500 litres complete all as specified and as directed by Engr-in-Charge.
All as per item no. 1 above but Water cooler of capacity 40 / 80 litres complete all as specified and directed by Engr-in-charge
All as per item no. 1 above but Water cooler of capacity 60 / 120 / 150 litres complete all as specified and directed by Engr-in-charge
All as per item no. 1 above but Deep freezer of capacity 205 to 310 litres complete all as specified and directed by Engr-in-charge
All as per item no. 1 above but Window / Split type AC of capacity 1.5 TR complete all as specified and directed by Engr-in-charge
All as per item no. 1 above but Window / Split type AC of capacity 2TR complete all as specified and directed by Engr-in-charge
All as per item no. 1 above but Piller/tower/package type AC of capacity 3.5 TR complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement fan motor / condensor motor and replacing the same with new fan / condensor motor 230 Volts, 50 Hz, SP suitable RPM for water cooler of capacity 40 / 80, 60 / 120 and 60 / 150 litres including connecting / mounting brackets to base frame and testing complete all as specified and as directed by Engr-in-Charge.
All as per item no. 9 above but of 230 Volts, 50 Hz, SP suitable for frost free refrigerator of capacity 165 to 500 litres complete all as specified and directed by Engr-in-charge
All as per item no. 9 above but suitable for window type AC of capacity 1.5 / 2 TR complete all as specified and directed by Engr-in-charge
All as per item no. 9 above but suitable for split type AC out door unit of capacity 1.5 / 2 TR complete all as specified and directed by Engr-in-charge
All as per item no. 9 above but for split type AC in door unit 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge
All as per item no. 9 above but suitable for Piller/tower/package type AC of capacity 3.5 TR complete all as specified and directed by Engr-in-charge
All as per item no. 9 above but of 230 Volts, 50 Hz, SP suitable for deep freezer of capacity 205 to 310 ltrs cap complete all as specified and directed by Engr-in-charge.
M & L for Vacuum the system and after maintaining vacuum for 24 hours supply and charge refrigerant gas HCFC 22/R 134/R 410A R/32 complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement Condensor unit for refrigerator of capacity 165 to 500 litres of any model, type, size and capacity including testing including making all connections complete all as specified and as directed by Engr-in-charge. NOTE: Gas charging shall be measured and paid separately.
All as per item no.17 above but for Water coolers 40/80,60/120/150 ltr capacity complete all as specified and directed by Engr-in-charge.
All as per item no. 17 above but for Window AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge.
All as per item no.17 above but for Split type AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge.
All as per item no. 17 above but for Deep freezer of capacity 205 to 310 litres complete all as specified and directedby Engr-in-charge.
Supply and fixing in replacement Cooling unit for refrigerator of capacity 165 to 500 litres of any model, type, size and capacity including making all connections complete all as specified and as directed by Engr-in-charge. NOTE: Gas charging shall be measured and paid separately
All as per item no. 22 above but for Water coolers 40/80,60/120/150 ltr capacity complete all as specified and directed by Engr-in-charge.
All as per item no. 22 above but for Window AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge.
All as per item no. 22 above but for Split type AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge.
All as per item no.22 above but for Deep freezer of capacity 205 to 310 litres complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement of internal wiring bit & necessary wire for refrigerator of capacity 165 to 500 litres of any model, type, size and capacity including making all connections complete all as specified and as directed. NOTE: Gas charging shall be measured and paid separately
All as per item no.27 above but for Water coolers 40/80,60/120/150 ltr capacity complete all as specified and directed by Engr-in-charge.
All as per item no.27 above but for Window AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge.
All as per item no.27 above but for Split type AC of capacity 1.5/2 TR capacity complete all as specified and directed by Engr-in-charge.
All as per item no.27 above but for Deep freezer of capacity 205 to 310 litres complete all as specified and directed by Engr-in-charge.
M & L for Detecting gas leakage of refrigerators, water coolers, deep freezers, window/split/piller type AC's and creating vaccum , rectifying/arresting the leakages,testing for pressure drop , charging refrigrant gas in the unit to the required pressure complete all as specified and as directed by Engr-in-Charge.
Supply & fixing in replacement running/starter capacitor 2.5/3.15/4.0/6.0 mfd, ,250 volts , AC, from cooling appliances complete all as specified and as directed by Engr-in-Charge.
All as per item no.33 above but of 36.00 mfd 6 pin complete all as specified and directed by Engr-in-charge
All as per item no. 33 above but of 45 mfd 6 pin complete all as specified and directed by Engr-in-charge
All as per item no. 33 above but of 80.0/100.0 mfd complete all as specified and directed by Engr-in-charge
All as per item no. 33 above but of 50.0/6 mfd complete all as specified and directed by Engr-in-charge
Supply and fixing in replacement thermostat suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed by Engr-in-Charge.
Supply and fix capillary & filter suitable for AC , water cooler, Deep freezer, refrigerator complete all as specified and directed as specified by Engr-in-Charge
Supply and fixing in replacement over load protector suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement starting box type relay of package assembly from Window type AC's of capacity 1.5 / 2 TR including testing complete all as specified and as directed by Engr-in-Charge.
All as per item no.41 above but for Split type AC's of capacity 1.5 / 2 TR complete all as specified and directed
All as per item no. 41 above but for Refrigerators of capacity 165 to 500 litres complete all as specified and directed
All as per item no. 41 above but Water coolers of capacity 40 / 80, 60 / 120 & 60 / 150 litres complete all as specified and directed
All as per item no. 41 above but for Deep freezers of capacity 205 to 310 Litres complete all as specified and directed
M&L for opening body of water coolers, taking out cooling tank to rectifiy leakage of refrigerant tube/condensor and refixing the same after carryout necessary repairs, including leakage test, filling insulation material and clamping with GI strip complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement 15 mm dia ball/float valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms /20 m m - 210 g m s . / 25 mm-455 gms/ 40 mm- 690 gms) from water cooler of any capacity, make, location etc including connecting and testing complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement Push cock, 15 mm dia, brass cromium plated ( SS 304 ) self closing type complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement 15 mm dia Stop valves, brass,chromium plated screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Stainless steel SS 304 water drain out tray for water cooler complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement PVC connection 15 mm bore , 600 mm long with brass ends terminals suitable for water coolers complete all as specified and as directed by Engr-in-charge
Supply and fixing in replacement of top cover with gasket for water cooler of any capacity complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement PVC pipe 32 mm dia for draining out waste water complete all as specified and as directed by Engr-in-charge
Supply and fixing in replacement Fan blade set for water cooler fan motor complete all as specified and directed by Engr-in-charge.
M&L for repairing of foundation/bottom base of water coolers any make & type with suitable size angle iron by welding/screwed/nutbolts after giving proper shape and making good complete all as specified and directed by Engr-in-charge.
S & Fixing GI tubbing medium grade 15 mm with all fittings in any position at any location complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement Timer for refrigerator of existing specifications of any model, type, size and capacity complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Bimetal for frost free for refrigerator of any model, type, size and capacity complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Capiliary tube of refrigerators of any model, type, size and capacity to suit the existing complete all as specified and as directed. by Engr-in-charge.
Supply and fixing in replacement Magnetic rubber gasket for refrigerator door of capacity 165 to 500 litres , of any model, type, size and capacity to suit the existing including connecting complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Copper tube 1/4" size , thickness greater than 0.7 mm complete for cooling appliances , of any model, type, size and capacity to suit the existing including connecting complete all as specified and as directed by Engr-in-charge.
All as per item no. 61 above but of size 1/2"
All as per item no. 61 above but of size 3/8"
All as per item no. 61 above but of size 5/8"
Supply and fixing in replacement Evaporative cooling coil for refrigerator of capacity 165 to 500 litres of any model, type, size and capacity as per existing including testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Plug top 3 pin, 230 Volts, 16 Amps including testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Refrigerator door to refrigerator of any capacity from 165 to 500 litres of any model, type, size including testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Heater of any size to refrigerator of any capacity from 165 to 500 litres of any model, type, sizecomplete all as specified and as directed by Engr-in-charge.
Labour only for repairing and attending the complaint of Split/WindowAC/ Water cooler/Refrigerator/desert cooler by highly skilled tradesman and carryout minor repair and making functional complete all as specified and directed by Engr-in-charge at site. Note :- (replacement of major spare part will be measured and paid separately under appropriate items )
Taking out & removing old existing plywood (if present)of any description and in any position and supplying and fixing new plywood 4mm thick, grade BWR, type BB, 3 ply, cut to size made to shape and fixed in position with nails as to make the window of desert cooler/window AC etc air tight complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Air filter PVC type of existing window air conditioners/ split AC of capacity 1.5 / 2 TR,from any position, of any make complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement Fan blade of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement MCB,SP,32 Amps 230/240 Volts,50 Hz for existing window / split type air conditioners complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Sheet metal enclosure with 3 pin metal clad socket 32 Amps with metal clad plug top including 1 No MCB, SP of capacity 32 Amps for existing window / split type air conditioners ,from any position, of any make including testing complete all as specified and as directed by Engr-in-charge.
M&L in replacement Metal clad DP Plug Assembly AC, 220 V, 50Hz, suitable for MCB of capacity 32A, with 2 Pin and one earth pin , complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement PVC insulated cable 3 core 2.5 Sq mm, FRLS 1100 Volts grade copper conductor, multistranded including testing complete all as specified and as directed by Engr-in-charge.
M&L Sub main wiring complete with non-metallic rigid PVC insulated fire retardant grade unsheathed 1100V grade multistranded copper conductor cable 2 run of 6 Sqmm single core confirming to IS-694 with copper conductor drawn through PVC casing capping/conduit heavy duty and accessories in walls, roof and floors along with 1 run of 6 Sqmm PVC insulated unsheathed cable with multistranded copper conductor as earth continuity conductor complete including chase cutting by cutter concealed in PVC conduit complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement with new display assembly of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Heatlion insulation pipe for wrapping copper tape duly fixed with polythelene type to suction and discharge lines for existing split type air conditioners 1.5 / 2 TR,including refixing with cable tie , clamping from any position, of any length of any make including testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of front grill with air filter of window AC 1.5/2 TR of any make complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of wireless remote control (micro-processor) unit suitable to window/split AC 1.5/2 TR complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement of bottom tray of window AC 1.5/2 TR of any make complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement with new Electronic card/ PCB of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing complete all as specified and as directed by Engr-in-charge.
Material & labour for repairing electronic card / PCB of window / split AC including taking down/out electronic card /PCB including refixing back at site after repair & testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement cross linked PVC pipe 15 mm dia with all fittings of existing window / split type air conditioners of capacity 1.5 / 2 TR for drainage,from any position, of any make including testing complete all as specified and as directed by Engr-in-charge.
S&F complete indoor unit of split type AC 1.5 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor, swing blade filter, PCB, Thermostat etc complete all as specified and as directed by Engr-in-charge.
S&F complete outdoor unit of split type ac 1.5 TR in replacement of existing worn out indoor unit complete with outdoor fan motor, outdoor fan, condenser unit with cooling coil, copper/aluminium fins, wiring etc as per existing with connection for indoor and outdoor with copper tubing complete all as specified and as directed by Engr-in-charge.
S&F complete indoor unit of split type AC 2 TR in replacement of worn out unit Comprises of cooling coil, blower, blower motor, swing motor, swing blade filter, PCB, Thermostat etc complete all as specified and as directed by Engr-in-charge.
S&F complete outdoor unit of split type ac 2 TR in replacement of existing worn out indoor unit complete with outdoor fan motor, outdoor fan, condenser unit with cooling coil, copper/aluminium fins, wiring etc as per existing with connection for indoor and outdoor with copper tubing complete all as specified and as directed by Engr-in-charge.
S&F MS stand factory made suitable for condensing unit of split type AC duly powder coated complete all as specified and as directed by Engr-in-charge.
S&F MS stand factory made suitable for window type AC duly powder coated complete all as specified and as directed by Engr-in-charge.
Supply & fixing of slide-out & fixed Chassis in replacement to worn out chassis of window AC comprises of bottom cover and outer cover duly powder coated including all connection complete all as specified and as directed by Engr-in-charge.
S&F in replacement of blower assembly suitable to Split AC cap 1.5/2 TR complete all as specified and as directed by Engr-in-charge.
Taking down defective /unserviceable of commercial air curtains unit of 5 feet long and mounted at 7.25 feet, repaired/rewinding of high speed motor with super enamelled copper wire of unserviceable Air curtain height from ground level for presentation of dust and conditioned air losses, single phase 220 V and 50 Hz made out of MS CRCA sheet of aluminium thickness 1 gauge finished with two coat of red oxide primer and final coat of synthetic enamel paint (over baked) with MS -CRC 18 gauge square perforated suction grills, aluminium alloy fans and single phase electric motor, nozzle etc complete with fitted and accessories so as to produce 1-1.5 m/sec air velocity at floor level complete all as specified and as directed by Engr-in-charge. (Note :- during the time of fixing of Air curtain if any item required at site i.e angle iron etc. cost of the same deemed to be quoted rate)
All as per srl Item No.95 but size 6 feet long and 7.25 feet complete all as specified and as directed by Engr-in-charge.
Supply & fix compressor for bottled water dispenser including brazing work creating vacuum for 24 hrs for pressure testing and charging of refrigerant R134a, having option of dispensing hot and cold water withcooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity1.6 ltrs, working in R - 134a refrigerant complete all as specified and as directed by Engr-in-charge.
Supply & fix evaporator with capillary filter for bottled water dispenser including brazing work creating vacuum for 24 hrs for pressure testing and charging of refrigerant R134a, having option of dispensing hot and cold water withcooling capacity 3 ltrs/hr and tank capacity of 3.4 ltrs, heating capacity 6 ltrs/hr and tank capacity1.6 ltrs, working in R - 134a refrigerant complete all as specified and as directed by Engr-in-charge.
Supply & fixing in replacement of old rusted desert cooler capacity 4000/5000 cum/hr made out of GI sheet 22 SWG complete with front panel and replacement of complete cooler body, U/S fan motor and U/S water Pump of approved make all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement of fan blade made of GI sheet of heavy duty for desert cooler for any capacity complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement PVC flexible rubber pipe 15 mm dia for desert coolers complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Plug top 3 pin, 230 Volts, 6 Amps including testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement wood wool pad (set of 3 ) of suitable size to dessert cooler of capacity 3000 to 6000 CFM complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Drum/fan motor copper wound 230 Volts, 50 Hz, 1440 RPM , SP for desert cooler of any capacity,from any position, of any make including testing & mounting arrangement complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Water pump, 18/20 watt , 230 Volts, 50 Hz, SP with discharge head of 1.87 m for desert cooler of any capacity complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement PVC insulated cable 3 core multistand copper conductor FRLS 1100 Volts grade 1.5 Sq mm for desert coolers including testing complete all as specified and as directed by Engr-in-charge.
Taking down/out split/window type AC 1.5 / 2 TR capacity of any make, from existing postion, transporting and refixing at the new location including fixing complete unit with gitties/fastner, cutting wall / concrete including arrangement of T&P for laying copper tubing , brazing work , making necessary connections to make it functional complete all as specified and directed by Engr-in-charge. Note : (a)Gas charging if regd shall be measured and paid separetely. (b) any additinal copper tubing & parts required for shifting the unit is deemed to be included in qouted rates.
Taking down/out from existing position window type AC's of capacity 1.5 / 2 TR , servicing the same by washing filters with soap solution jet followed by clean water, cleaning, drying , dusting with blower to complete assembly , checking wiring, replacement of worn out nuts, bolts, electric connections, tightening all loose parts for proper functioning, setting grills and fan blades incluidng oiling, greasing/lubricating to moving parts and refixing to its original position and testing for smooth functioning complete all as specified and as directed. NOTE:(a) Entire work is to be carried out to be OEM only. (b) Cost of all T&P i.e. Blower, pressure pump , bucket, hose pipe etc is deemed to be included in the coated rates.
Taking down/out from existing position split type AC's indoor & outdoor unit of capacity 1.5 / 2 TR , servicing the same by washing filters with soap solution jet followed by clean water, cleaning, drying , dusting with blower to complete assembly , checking wiring, replacement of air filter , worn out nuts, bolts, electric connections, tightening all loose parts for proper functioning, setting grills and fan blades incluidng oiling, greasing/lubricating to moving parts and refixing to its original position and testing for smooth functioning complete all as specified and as directed. NOTE: Entire work is to be carried out to be OEM only. (b) Cost of all T&P i.e. Blower, pressure pump , bucket, hose pipe etc is deemed to be included in the coated rates.
All as per item No. 109 above but refrigrator, deep freezers, water cooler of any capacity complete all as specified and as directed by Engr-in-charge.
All as per item No. 109 above but Piller/Tower/Package type AC of capacity 3.5 TR & Air Curtains of any capacity complete all as specified and as directed by Engr-in-charge.
M&L for preparing the surfaces by scrapping out the old paint and painting with two coat of painting of synthetic enamel paint (nerolac) inside & outside surface and applying two coats of rubber seal paint inside water tank to desert cooler capacity upto 5000 cum/hr by spray painting including rewriting MES/SM NO. complete all as specified and directed by Engr-in-charge
S&F water dispencer in replacemet of worn out, U/S rusted body and floor mounted, cooling cabinet 5 ltrs hot and cold both with 10 Ltrs capacity of storage, having refrigerant 134a complete all as specified and as directed by Engr-in-charge.
M&L for Replacement of complete rusted body of voltage stabilizer including U/S transformer , U/S buck & boost relay , U/S electronic control PCB , U/S timer circuit and trigger transformer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 4 / 5 KVA complete all as specified and as directed by Engr-in-charge.
S&F in replacement transformer, relay and PCB of voltage stabilizer of capacity upto 5 KVA as per existing complete all as specified and as directed by Engr-in-charge.
Taking down/out from existing position RO water filter/Purifier filter unit of any capacity 40/60/80 120 LPH , servicing the same by washing all filters Like sendiments filter,carbon filter UV filter, mineral catridge, Flow restrictor,pressure switch with jet followed by clean water, cleaning, drying complete assembly , checking wiring, replacement of Adapter 24V-DC ,Worn out Sensor Module, Booster pump electric connections, tightening all loose parts for proper functioning and refixing to its original position and testing for smooth functioning complete full service complete all as specified and directed by Engr-in-charge. NOTE: Entire work is to be carried out to be OEM only. (b) Cost of all T&P i.e. All filter, pressure pump ,Solenoide Valve, hose pipe etc is deemed to be included in the coated rates.
Supply and fixing in replacement Ro filter suitable for RO water filter of 40/60/80 LPH any make, capacity and model and testing complete all as specified and as directed by Engr-in-charge.
All as per item no. 117 above but Solenoid valve complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but SMPS 24V complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but Booster pump 24V DC complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but Flow restrictor (FR300/FR450/FR550 complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but Pressure switch complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but elbow, any make complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but T- Connector complete all as specified and directed by Engr-in-charge.
All as per item no. 117 above but Floating Switch complete all as specified and directed by Engr-in-charge.
Supply and fixing in replacement RO Membrane/Mineral filter, Sendiments filter suitable for RO water filter of any make, capacity and model and testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement Pre carbon filter,post carbon filter suitable for RO water filter of any make, capacity and model and testing complete all as specified and as directed by Engr-in-charge.
Supply and fixing in replacement PVC pipe size 3/8" suitable for RO water filter of any make, capacity and model and testing complete all as specified and as directed by Engr-in-charge.
All as per item no. 128 above but PVC pipe size 1/4" complete all as specified and directed by Engr-in-charge.
Note: 1. Contractor has to deploy one refrigeration mechanic with one helper daily for day to day complaints pertaining to central/Package AC plants of any size/capacity for 24 hrs, Rate deemed to be included in quoted rates above failling which recovery shall be made on account of the same by the rate prevailing for one skilled and semi skilled by Delhi Govt 2. Contractor has to submit copy of MOU with OEM of respective plant and machinery within 20 days of work order failing which recovery shall be made on this account @ rate of 3000 rs day
M/S S.K.Electricals (BID ID -3084284)
V r traders (BID ID -3087808)
Deepak Electricals (BID ID -3084040)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .