| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.8 LAccepted-AOC 96 1 HIMMATGANJ BEHIND UNANI MEDICAL COLLEGE PRAYAGRAJ 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹15.1 L+₹72,399.60 (5.05%)Rejected-Finance 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L2 | Rejected-Finance Being not lowest | |
| 3 | L3₹15.2 L+₹82,957.72 (5.79%)Rejected-Finance HOUSE NO 39 KRISHNA VIHAR OPPOSITE KV AIR FORCE MANAURI DISTT PRAYAGRAJ UP 212208 | PRAYAGRAJ | UTTAR PRADESH | 212208 | L3 | Rejected-Finance Being not lowest | |
| 4 | L4₹15.2 L+₹83,024.08 (5.79%)Rejected-Finance | L4 | Rejected-Finance Being not lowest | |
| 5 | L5₹22.4 L+₹8.1 L (56.5%)Rejected-Finance 5 31 EWS PREETAM NAGAR ALLAHABAD 211011 | ALLAHABAD | ALLAHABAD | UTTAR PRADESH | 211011 | L5 | Rejected-Finance Being not lowest |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
10 Jun 2024, 6:00 pmClosed
AGE (I) AF Manauri
AGE (I) AF Manauri Prayagraj-212212
REPAIR / MAINT OF INTERNAL ELECTRIC INFRASTRUCTURE, LED ENERGY EFFICIENT SUBMAIN WIRING WITH OTHER ALLIED WORKS OF WATER SUPPLY INSTALLATIONS, RO PLANT INSTALLATIONS
2024_MES_652690_1
9146/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
AGE (I) AF Manauri Prayagraj
As per Tender Documents
7 documents required · 7 mandatory
₹500
Yes
AGE (I) AF MANAURI
₹29,000
Yes
22 Oct 2024
7 May 2024
12 Jun 2024
7 May 2024
10 Jun 2024
22 May 2024
Amount
Taking down carefully (aluminium) point wiring complete of any type (batten/surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete removing material to store of keeping in safe custody or for taking credit complete all as specified and directed.
M&L for point wiring including concealed in surface of structure/ truss etc rigid non-metallic PVC conduit pipe medium grade, ISI marked heavy duty in size 20 MM dia with 1.5 Sqmm FRLS insulated unsheathed, multi stranded copper conductor cable, single core 1100 volt grade with flush cast iron/ pressed steel terminal boxes of suitable size for fixing such as switches, sockets and fan regulators etc with modular cover plate and fixing with brass screws/cup washer and including FRLS insulated & unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 Sqmm as continous earth wire complete including making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface for the following complete all as specified and directed. Note:- Quoted rate shall be included cost of cheasesing, cutting, plastering and colouring etc to surface of wall / beam/ roof etc as site required matching with existed surface and blank plate to be cover up to extra gap in mounting board in given module /make / model etc.
All as per item No. 2.00 above but one light point controlled by one way indepdent switch complete all as specified and directed.
All as per item No. 2.00 above but one fan controlled by one way indepdent switch complete all as specified and directed.
All as per item No. 2.00 above but one 3 pin 5 Amps socket out let point on same board controlled by one switch complete all as specified and directed.
All as per item No. 2.00 above but one 3 pin 5 Amps socket out let point on independent board controlled by one switch complete all as specified and directed.
All as per item No. 2.00 above but point wiring for 15 Amps socket using 2.5 Sqmm copper cable for phase and neutrl and 2.5 Sqmm as earth wire complete all as specified and directed.
All as per item No. 2.00 above but power point wiring using 4 Sqmm copper conductor cable FRLS insulated unsheathed and unsheathed copper conductor of 4 Sqmm as earth wire complete all as specified and directed. Note : All circuit shall be taken from seprate control DBs (connected with energy meter) to be connecting indivisual power load complete all as specified and directed.
M&L for point wiring in PVC Casing & Caping single core PVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area), fixed on wall (concealed conduit wiring) on wall and on ceiling with GI saddles, GI screws, rowel plugs with all fittings including tee, junction boxes and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with multi stranded copper conductor of size 1.5 sqmm (Nominal area) connected to earth dolly complete all as specified and directed.
All as per item No. 3.00 above but one light point or one fan point controlled by one switch with cable 1.5 sqmm size complete all as specified and directed.
All as per item No. 3.00 above but one 3 pin 5 amps socket out let same board controlled by one switch complete all as specified and directed.
All as per item No. 3.00 above but one 3 pin 6 amps socket outlet on independent board controlled by one switch complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 5 Amps complete all as specified and directed.
S&F switch piano, flush type, single pole, one way 15 Amps complete all as specified and directed.
S&F power unit single phase 220 volts 32 Amps socket and control switch ISI marked 4 module complete all as specified and directed.
S&F switch socket combination 2 in 1, 5 pin 5 Amps flush type complete all as specified and directed.
S&F switch socket combination 2 in 1, 5 pin 6/ 16 Amps flush type complete all as specified and directed.
S&F stepped type electronic fan regulator flush type on existing phenolic laminated sheet etc as required complete all as specified and directed.
S&F in replacement LED recessed mounted 2x2 luminaire LED 36 W light fitting energy saving low glare high power mounting on two Nos PVC round/ square block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete all as specified and directed.
S&F in replacement LED recessed mounted down 18 W light fitting energy saving low glare high power mounting on two Nos PVC round/ square block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete all as specified and directed.
S&F in replacement LED light fitting with frame, driver etc in 20 W 4 feet long white colour mounting on tow Nos of PVC round/ square block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete as directed. Make: Bajaj Cat No BCSLB 20 WH / Havells / Phillips / Crompton
S&F in replacement LED tube light fitting with frame, driver etc in 10 W 2 feet long white colour mounting on tow Nos of PVC round/ squire block on surface of wall / beam etc including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings including taking out to unserviceable old fittings complete as directed. Make: Bajaj Cat No BCSLB 10 WH / Havells / Phillips / Crompton
M&L for sub main wiring with two runs of single core PVC FRLS IS-694 cable with unsheathed multi-stranded copper conductor of size 06 Sqmm and drawing through in concelead rigid non metallic PVC conduit pipe medium grade heavy duty in suitable size with all necessary fittings including one run of FRLS insulated unsheathed stranded copper conductor cable of size 06 Sqmm as earth wire (green in colour) and connected to common earth dolly including taking down of old unserviceable sub main wiring with accessories complete all as specified and as directed. Note : (i) Two run of 06 sqmm with one run of PVC conduit pipe shall be measured against one unit. (ii) Cost of cutting /chasing/ plastering /colouring etc as site shall be included matching to disturbed surface all as existed.
All as per item No. 14.00 above but three run of 2 Core 4 Sqmm for phase, neutral and earth wire with suitable size concealed PVC conduit pipe complete all as specified and directed.
S&F sheet metal enclosure distribution board TPN, 4 poles, double door, 4 way with 200 Amps rated bus bar vertcal type with MCCB 4 pole 100 Amps 415 volt thermal megnatic base operated as incomer including concealed in surface of wall and making all connection using gland, thembles in required size including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed. Note : Quoted rate shall be included cost of MCCB , cutting plastering, colouring to surface of wall to be concealed etc all site required matching with existing surface.
S&F sheet metal enclosure for MCB distribution board SPN, double door, 8 way with 200 Amp rated bus bar 230 Volts including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
S&F sheet metal enclosure for MCB distribution board SPN, double door, 4 way with 200 Amp rated bus bar 230 Volts including taking down to old unserviceable DBs in any make/ model/ way etc with accessories complete all as specified and directed.
S&F in replacement MCB, SPN, 2 pole 220 volts, 40 Amps, "C" Curve 10 kA complete all as specified and directed.
S&F in replacement MCB, single pole 215 volts, 10-32 Amps, "C" Curve 10 kA complete all as specified and directed.
S&F in replacement LED bulb 12 W complete all as specified and directed.
S&F in replacement of 100 watt flood light fitting for replacing with High mast tower / pole in any length / specification, energy saving IP 65 protection, required nut bolt washer etc including making electric connection using three core copper flexible cable drawn through in PVC flexible conduit complete all as specified and directed. Note: Quoted rate shall be included cost to take down / up, replacing of inter connection cable etc and other required site work.
S&F in replacement of 60 watt LED street light fitting with pressure die cast aluminium housing with heat resistant toughened glass and accessories & IP66 protection, white cool, Raptor Neo, metal, input Voltage 220 V including making connection complete from fitting to pole/terminal box complete all as specified and directed.
S&F in replacement 10 W LED bulk head light fittings including making all electric connection using three core copper cable drawn through in PVC flexible counduit pipe from ceiling rose to fittings complete all as specified and directed.
M&L for earthing (in replacement) complete with galvanized steel earth plate electrode of size 60 CM x 60 CM x 6 MM thick buried directly in ground (earth pit not less than 2.25 m deep below the ground level) with top edge of earth plate not less than 1.50 m below normal ground level connected to galvanized earth lead strip 32 x 6 mm size by means of nut, bolts & check nuts and washers of galvanized iron or steel connected to Earthing test point complete all as specified or indicated, including earthing pit with PCC 1 : 3 : 6 type C1 (using 20 mm graded crushed stone aggregate) & RCC cover slab 40 mm thick as in RCC 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) reinforced with 8 MM dia TMT bars @ 150, mm centre to centre both way with two Nos lifting handle, GI pipe 20 mm dia 'light grade' with funnel and wire mesh for watering and 40 mm dia 'light grade' GI pipe for GI earth strip 32 x 6 mm protection etc complete all as shown in electrical plate No. 3 of SSR Part - I (2009) including testing on completion complete all as specified and directed.
S&F in replacement MCCB, 3 pole, TPN 63 Amp rating having breaking capacity of 16 kA at 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand / Siemens / L&T / Havells
All as per item No. 26.00 above but 4 pole 415 Amps 125 Amps capacity complete all as specified and directed. Make: Legrand / Siemens / L&T / Havells
S&F in replacement MCCB, 4 pole, 250 Amp rating having breaking capacity of 36 KA at 415V adjustable thermal process based magnetic setting type Ics=75% Icu complete all as specified and directed. Make: Legrand / Siemens / L&T / Havells
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth for pipe line, etc getting out in soft/ loose soil and levelling of bottom surface to required level complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 CM complete all as specified and directed.
Removing excavated material (soil) out side MD land at contractor's own arrangement complete all as specified and directed.
Supply, laying and spreading of dry (Ganga) sand, free from organic impurities for cushioning as in trenches 8cm depth below cable and 15cm above cable and punned to 10cm depth complete all as specified and directed. Note :- Punned thickness shall be considered for measurement purpose.
M&L brick, sub class 'B' bricks laid dry, flat, length equal to width of brick over sand cusioning in trenches for cable protection complete all as specified and directed
Labour only for cutting/boring to plinth protection/hard standing/road etc in suitable depth and corssing of GI pipe of size 80 MM bore so that XLPE under ground cable can be passed and giving mechanical protection to cable complete all as specified and directed. Note:- Quoted rate shall be included the cost of required material for repairing to disturbed surface all as per existing specification and GI pipe shall be measured and paid seperately under respective itmes.
Supply, laid in trench /fixed in replacement with surface of wall/roof etc jointing, thimbling and glanding in suitable size testing to cable XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured electric LT cable with alumunium conductor 1100 volts, grade cross section area 4 core x 25 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
All as per item No 35.00 above but size of cable 3.5 core x 50 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
All as per item No 35.00 abvoe but size of cable 3.5 core x 120 Sqmm (earthed) complete all as specified and directed. Make: Havells / Finolex / RPG / Polycab / Paragon / Fort Gloster
S&F in replacement 40 mm dia GI tubing 'light grade' with fixing acessories laid in trenches or on wall or pole with clamp complete all as specified & directed. Make: Tata / Jindal / Swastik
All as per item No. 38.00 above of but size of 50 MM dia complete all as specified & directed.
All as per item No. 38.00 above but of size of 80 MM dia complete all as specified & directed.
M&L painting to steel prepared surfaces of any width or girth not otherwise described by using synthetic enamel paint in two coats (one as finishing coat) over one coat of red oxide zinc chrome primer on surface of steel structure / girder / angle frame / wire mesh fencing (both side) / installation board / gate etc in any description at E/M installation using paint spray gun on specified working pressure including sign making / marking with using different colour in given size of letter etc complete all as specified and directed. Note: Paint colour & shade including writing marking of letters etc shall be deemed included in quoted unit rate and the same shall be approved by Engr-in-Charge. Make: Asian / Berger / Dulex
M&L Painting to existing two/three steel pole structure of 11 m height including mild steel work like cross arms, clamps, pipe channel, bracing etc after cleaning and prepration of surfaces painting externally above planting depth with one coat of aluminum paint over a coat of aluminum primer including preparation of existing surfaces and marking pole numbers in 15 cm dia with approved colour in circular and making 03 Numbers & 02 Numbers of bands & strips with 30 cm wide fluorescent paint from bottom of pole to 1.5 m height of pole complete all as specified and as directed. Note: Cutting of bushes & tree branches upto 3 m height of pole shall be deemed included in quoted unit rate.
All as per item No. 42.00 above but steel tubular pole in 9 m long complete all as specified & directed.
S&F in replacement Air circulator fans 230 volts single phase oscillating 450 mm sweep suitable for wall mounting complete all as specified & directed.
S&F in replacement Aviation Obstruction Light yellow painted die cast aluminium alloy housing built in 75VA step up transformer, heat resistant, clear thick glass and accessories with all making connection complete all as specified & directed.
S&F in replacement to shock proof, fire retardant rust proof, out door pole kiosk box of size 295 x195 x100 MM made out of one piece Engineer plastic moulding of siemens grey colour with in built 4 aluminium strip of 60 Amp rating fitted on DMC unbrakable insulator with MCB SPN 40 Amp including fixing arrangement as clamps made out by GI strip in size 32 x 6 MM and nut bolts washer with painting in two coat syenthic enamel paint over one coat of red oxide primer etc complete all as specified and directed.
S&F in replacement three core copper flexible wire, PVC insulated sheathed copper conductor muiti strandard in 1.5 Sqmm size for making inter connection of street/ road light fittings from control box to fittings drawn through in steel tubular pole including lugs / thimbles in required size etc complete all as specified & directed.
S&F in replacement three pole power contactor type ML-6 suitable for AC1 rating 125 Amp range, 240 volt confirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-3, 2 NO+ 2 NC including making connection complete all as specified & directed. Make: L&T Model-SS90921 / Siemens / Schneider / C&S / MDS
S&F in replacement three pole power contactor type MNX-32 suitable for AC1 rating 55 Amp, AC3 rating 32 Amp, range, 240 volt confirm to IS/ IEC 60947-4-1 & IEC 60947-4-1 size Fr-2, including making connection complete all as specified & directed. Make: L&T Model-CS94111 / Siemens / Schneider / C&S / MDS
S&F in replacement of off load change over switch in sheet metal enclosure 4 poles, 250 Amp rated, 440 volts, 50 Hzs, confirm to IEC 60947-3, IS/IEC 60947-3 alongwith extendable handle with making all connection and fixing accessories on surface of wall/panel operating handle etc complete all as specified & directed. Make: L&T / Havells / Siemens
S&F on load change over, 160 Amp, 415 volt in sheet steel enclosure type Fr2 (4P), manual, suitable for DIN fuseiling and providing electrical connection with suitable size copper lugs and wires, complete making all electrical connections including taking down old unserviceable change over switch complete all as specified & directed. Make: L&T Cat Part No. CO21600OSOO / Siemens / Legrand / ABB
Supply, erecting and fixing in replacement steel tubular swaged pole 9.00 mtr long type 410 SP-31 confirming to IS - 2713 Prt I to III 1980 with and including cast iron base plate, finial taper plug, Nuts, bolts and washers etc and fixed into plain cement concrete foundation duly painted with two coats of aluminium paint over coat of red oxide primer including preparation of surfaces and making strip 150 mm wide up to 1.50 Mtr (above PCC coping) by black, yellow, paint in alternate layer and pole numbers complete all as specified & directed. Note : Earth work, cement concrete will be incuded in quoted unit rate.
S&F in replacement fully cast aluminium body finished with polyurethane paint (with prior treatment) LED post top lantern 40watt with acrylic window cover total length 762 mm & Max.Breath 431 mm with spigot entry 78mm with all fixing arrangements complete all as specified & directed. Make: Bajaj / Mepro / Havells / Crompton
Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ. (ii) Make of material shall be as per mentioned in Particular specifications or Appendix 'B' to Particular specifications as approved by AGE (I) AF manauri
M/S VIJAY SINGH
AMRESH TRADERS
HIMANSHU TRADERS
M/S vibhuti enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .