| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.0 LAccepted-AOC M S CHANANA ENGINEERS CONTRACTORS AZAD CHOWK FEROZEPUR CANTT FEROZEPUR PUNJAB 152001 | FIROZEPUR | PUNJAB | 152001 | ₹10.0 L | 1 | Accepted-AOC Lowest |
| 2 | 2₹10.3 L+₹29,657.60 (2.98%)Rejected-Finance | ₹10.3 L+₹29,657.60 (2.98%) | 2 | Rejected-Finance Higher |
| 3 | 3₹10.6 L+₹59,170 (5.94%)Rejected-Finance 29 MODEL TOWN BEHIND GURUDWARA PATHANKOT | PATHANKOT | PATHANKOT | PUNJAB | 145001 | ₹10.6 L+₹59,170 (5.94%) | 3 | Rejected-Finance Higher |
| 4 | 4₹11.4 L+₹1.4 L (13.9%)Rejected-Finance | ₹11.4 L+₹1.4 L (13.9%) | 4 | Rejected-Finance Higher |
| 5 | 5₹12.9 L+₹3.0 L (29.9%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | ₹12.9 L+₹3.0 L (29.9%) | 5 | Rejected-Finance Higher |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
5 Oct 2021, 3:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
REPAIR/MAINT/REPLACEMENT OF STREET LIGHT AND COMPLAINTS OF STREET LIGHTS AT OLD AMRITSAR CANTT
2021_MES_473880_1
GE/ASR-26/2021-22
Open Tender
Civil Works
Item Rate
273 days
GE Amritsar
Class E, category bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹30,000
Yes
20 Oct 2021
8 Sept 2021
6 Oct 2021
8 Sept 2021
5 Oct 2021
22 Sept 2021
Amount
M&L for attending complaints including checking of existing street light of any type or description, fixed in vertical position with poles of 9/11/16 metre/wall including disconnecting the electric connection, removing from pole/wall if required, carrying out minor repairs like, removal of deposited carbon on joints/wires, removing of defective LED driver etc as required at site to make the items functional and refixing the same at same location or any other location, connecting with electric feeder and testing for functioning engaging sufficient man power and tool and plant etc to ensure safety of light/pole as well as working persons complete all as specified and directed. Note: (a) The completed job should remain functional for at least 6 month, any repair if required to be done for the same job within 6 months will not be paid separately. (b) T&P such as hydra/telescopic ladder required for attending the complaints is included in the quoted rate. .
Supply and fixing in repair of street light fitting bracket, 1.5 mtr long made out of galvanized iron pipe of 32 mm bore size light grade as required on site complete with nut, bolts, washer and MS clamp for PCC/Steel pole as required on site etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as specified and directed.Note: The cost of removing the street light fitting from old bracket,keeping safe and refixing the fitting in the new bracket is included in the quoted rate of the contractor
All as per item No 2 above but made out of galvanised iron 40mm bore light grade
All as per item No 2 above but made out of galvanised iron 50mm bore light grade
Cleaning and preparation of old painted surface of steel pole upto 9 Mtr long excluding planting depth complete and painting with one coat of aluminium paint including channels street light brackets cross arms anti climbing devices and making black & white strips with synthetic enamelled paint 30 Cm height, each alternative strip upto 1.5 mtr height writing pole numbers as per existing practice, making round base of dia 120mm by using yellow colour and marking the pole numbers of letter size equal to 70mm in height by using black colour with stencil complete all as specified and directed by Engr-in-Charge Note: The T&P required for the paintaing job such as hydra/telescopic ladder is included in the quoted rate.
Supply and fixing in replacement of thermoplastic polycarbonate cable junction box hinged door type of size 200x160x 98 mm for P and N incoming cable, 3 P and N outgoing cable and single P & N connection for light fitting with terminal block with cage and clamp system (screw less), shock proof safe IP-55, weather proof, rust, dust and water proof internally embedded gasket with provision for cable entry through gland alongwith MS clamps and mounting brackets as required at site complete all as specified & directed. Note : Cost of replacing the Aluminium thimbles for cable connecting to junction box is included in the quoted rate.
Excavation in trenches in any type of soil not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth below ground level for foundation of poles/ stays/cable and getting out complete all as specified .
Returning, filling in, including spreading levelling, watering and well raming in layers not exceeding 25cm thick complete all as specified and directed by Engr-in-charge.
Removal of surplus soil to a distance not exceeding 50 mtr & depositing where directed at a level not exceeding 1.5mtr above the starting point complete all as specified and directed by Engr-in-Charge .
Supply and laying old size as sub class 'B' bricks, laid flat in trenches over the cable along the length of cable and bricks perpendicular to the direction of cable adjacent / abutting each other compete all as specified . and directed by Engr-in-Charge.
Material and labour for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches complete all as specified and directed and sand cover to under ground cable complete all as specified . Note :- Thickness after punning down shall be measured.
S&F street light distribution outdoor panel with canopy single door vertical type made out of CRCA MS sheet with thickness of 3.15mm surface with insulated material like polysofer or with epoxy powder coating surface mounting TPN 4 way,415 Volt with copper bus bar rating 200Amps for R,Y,B,N phases dust and vermin proof suitable for incorporation of MCCB and IP65 profection with and including 100Amps 16KA 4 Pole MCCB including angle iron support legs and foundation work for the legs (including excavation and doing PCC 1:2:4). The size of the panel should not be less than 600mmx400mmx200mm, and height of the panel should be atleast 300mm above ground level. the angle iron for support should be minimum 35 mm x 35mm x 5 mm thick.
Supply and laying, in replacement, of LT underground cable XLPE insulated, inner PVC sheathed, galvanized steel strip armoured, overall PVC sheathed electric power cable with stranded compact aluminium conductor 1100 volts grade 16 sq mm 4 core confirming to IS:7098 (Part-I) with latest amendements, suitable for earthed system laid in duct/trench/along pole etc including making connection and taking out Note : 1. The cost of Al thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. 2. Excavation, earth work, sand cushioning and brick protection will be measured and paid separately under respective items.
All as per srl item No. 13 here-in-before but for multistranded cable size of 10 sq mm 2 core.
Supply and fix cable straight through jointing kit for LT XLPE grade cable for heat shrinkable complete with jointing materials and accessories suitable for 16 sq mm 4 core XLPE armoured aluminium conductor cable.
Supply and fix cable straight through jointing kit for LT XLPE grade cable for heat shrinkable complete with jointing materials and accessories suitable for 10 sq mm 2 core XLPE armoured aluminium conductor cable complete all as specified and directed.
M & L for PVC insulated PVC sheathed multi stranded copper conductor wire 2.5 Sqmm single core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box incl thimbles complete all as specified and directed.
Supply and fixing 1100V grade heavy duty cable PVC insulated multistranded aluminium conductor cable 2 core 6 Sqmm size complete for connection from fitting to overhead conductor complete all as specified and directed.
Supply and fixing / laying of galvanized iron pipe of 50 mm nominal bore light grade fixed to poles with clamps nuts, bolts and washers or laid under road crossing or fixed to wall including painting with two coats of aluminium paint over a coat of red oxide paint complete all as specified and directed. Note : The cost of MS clamp, nut, bolt, washer and GI fittings etc shall be inclusive in the item rate.
Material and labour for taking out and relaying existing LT cable of any size / type after repairing defects etc complete all as specified and directed. (Note : Excavation, earth work, sand cushioning and protection cover, joints will be measured and paid for separately under respective items.)
Supply and fix in replacement of 70W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studiness excellent corrosion resistannt and water proof fixture with efficient heat dissipation design and coating , housing should have two separate compartments for light source anf driver compartment. High efficiency LED module with SMD LED package mounted on MCPCB. Driver compartment should be separate accessible and top opening for each of maintenance. LED should be mounted on heat sink conductive aluminium with fence to dissipate the heat to ambient air, covered should be toughened glass/polycarbonate. Rated voltage 240V AC/50Hz operating voltage 140V-270V operating temperature -10 degree C to +50 degree C. Power factor >0.95 , average life 50,000 Hrs @ L70. THD < 10% with test certificate . CCT 5700K with test certificate. IK 07, CRI >70 with LED lumen efficacy of 135 Lumen per watt and system lumen should be 7400 lumens or above. Driver should be isolated electronic driver with APFC and SMPS based constant current supply with lower THD. Driver shall comply to BIS standard. Valid test report of LM 79 and LM 80 from NABL accredited laboratory need to be submitted. IP 66 protection and surge protection 10 KV built in SPD with 10 KV external also. Driver shall comply safety standart as per IS : 15885 part 2 / sec 13 . Performance requirement as per IS : 16104. Test standard as per IS;16102 (Part 1) : 2012/IEC : 62560:2011. Luminar shall comply to IS: 10322/IEC 60598 with minimum 5 Years warranty. Contractor shall produce the Genuineness and warranty certificate from the manufacturer before fixing. 2. All complaints will be rectified on PRIORITY basis upto completion of contract. 3. Contractor will arrange /provide suitable ladder (Telescopic/Hydra) with technicians for repair of street lights from statrting of contract upto date of completion of the work.
Supply and fix in replacement of 90W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 9000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site. Note:- Contractor shall produce the Genuineness and warranty certificate from the manufacturer before fixing. 2. All complaints will be rectified on PRIORITY basis upto completion of contract. 3. Contractor will arrange /provide suitable ladder (Telescopic/Hydra) with technicians for repair of street lights from statrting of contract upto date of completion of the work.
Supply only, in replacement of Universal driver suitable for LED street light of capacity 25-50 Watts complete with accessories as per existing make/size/type including single core wire 1.5sqmm aluminium/copper conductor from street light to terminal/conductor complete all as specified and directed by Engineer-in-Charge. Note : Fixing of LED driver will be paid under respective item of Schedule 'A'
Supply only, in replacement of Universal driver suitable for LED street light of capacity 60-90 Watts complete with accessories as per existing make/size/type including single core wire 1.5sqmm aluminium/copper conductor from street light to terminal/conductor complete all as specified and directed by Engineer-in-Charge. Note : Fixing of LED driver will be paid under respective item of Schedule 'A'
Supply only, in replacement of Universal driver suitable for LED street light of capacity 120 Watts complete with accessories as per existing make/size/type including single core wire 2.5sqmm copper conductor from street light to terminal/conductor complete all as specified and directed by Engineer-in-Charge. Note : Fixing of LED driver will be paid under respective item of Schedule 'A'
Cleaning and preparation of old painted surface of steel pole from 12/16 Mtr long excluding planting depth complete and painting with one coat of aluminium paint including channels street light brackets cross arms anti climbing devices and making black & white strips with synthetic enamelled paint 30 Cm height, each alternative strip upto 1.5 mtr height writing pole numbers as per existing practice, making round base of dia 120mm by using yellow colour and marking the pole numbers of letter size equal to 70mm in height by using black colour with stencil complete all as specified and directed by Engr-in-Charge
Supply and fixing in replacement of LED flood light fittings 120 Watt, pressure die cast aluminium housing with heat resistance toughened glass IP66 protection with PC lens for symmetric light distribution and toughened glass fixed on housing. Lumen efficacy of 140 lumen/Watt and system lumens 12600 or above . LM 79 and LM 80 report should be submitted to department. THD < 10 %, CRI >70, CCT 5700K, operating temperature -10 degree C to +45 degree C with integral electronic LED driver with APFC lower THD open circuit protection surge voltage protection upto 10 KV with built in SPD and other safety test as IS:15885Part-2/Sec13. IK 07. Average life 50000 Hrs @ L 70 B 50 on 12 to 16 Mtr pole complete fixing on the existing steel tubular pole 16 Mtr height inclluding making electric connection complete all as specified and directed by Engr-in-Charge . Note:- Contractor shall produce the Genuineness and warranty certificate from the manufacturer before fixing. 2. All complaints will be rectified on PRIORITY basis upto completion of contract. 3. Contractor will arrange /provide suitable ladder (Telescopic/Hydra) with technicians for repair of street/High mast lights from statrting of contract upto date of completion of the work.
Material & labour for clearing of LT line by triming, cutting, pruning of tree branches of any girth projected on overhead line and removal from site upto 50 mtr distance complete all as specified and directed.
S & F MCB double pole 40A, 240 volts, 100 Ampere, rupturing capacity 10 KA, ‘C’ curve type complete all as specified and directed.
Material & labour for supply, transporting, erecting truly in vertical position and fixing of steel tubular pole swaged, over all length 9 metres, type 410 – SP – 31 complete with mild steel base plate, pole cap, finial taper plug, MS bolts, nuts & washers, necessary excavation & earthwork in hard / dense soil, PCC sub base block as mass concrete of size 600 X 600 X 150 mm in cement concrete 1:4:8 Type D-2 in base of foundation, PCC foundation block of size 600 X 600 X 1500 mm in cement concrete 1:3:6 Type C-2, pole plinth of size 450 mm dia X 300 mm hight in cement concrete 1:2:4 Type B-1 including necessary form work as required at site and painting of pole with two coats of anti corrosive black bituminous paint through out internally and externally upto planting depth (embedded in concrete) and remaining portion of the pole painted two coats of aluminium paint over a coat of red oxide primer on complete exposed surface including painting of 05 Nos. bands / strips of 30 cm wide each with two coats of synthetic enamel paint (black & yellow) at a distance of 30 cm from plinth block upto 1500 mm height and marking / sign writing of pole number and feeders locations of pole with thick synthetic enamel paint (white) complete all as specified and directed. ( Note : PCC and earth work, clamps shall be meassured and paid separately under respective items of Sch A ).
Dismantling / taking out of old LT PCC/Steel tubular pole any type and any size from foundations including dismantling of concrete, MS clamps, nuts-bolts, earth wire, over head line conductors, insulators, guarding cradles and other accessories including necessary excavation and earth work in any type of soil complete all as specified and directed.
M&L PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in foundation for electric poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed by Engr-in-charge.
All as per srl item No 32 here-in-before but PCC 1:3:6 type C-2 as in foundation of stays and coping of poles
Material & labour for earthing complete with galvanised earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m below ground level) with top edge of earth plate not less than 1.5 m below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of nuts, bolts, check nuts & washers of galvanised iron or steel all as shown on electrical plate No. 3 of MES schedule 2009, Part – I (Specifications) and connected to main switch board / main DB’s / earthing test point including all necessary excavation and earth work in any type of soil, adequate quantity of charcoal dust & common salt all around the earth plate minimum 150 mm in all directions with & including watering pipe 20 mm dia GI medium grade, GI funnel made out of 0.63 mm thick GI sheet, wire gauge, 50 mm thick RCC cover in PCC 1:2:4, type B-1 (using 20 mm graded crushed stone aggregate), duly reinforced with 6 mm dia mild steel round bars @ 150 mm both ways center to center with suitable lifting handle to cover, earth pit of PCC 1:3:6 type C-1 (using 20 mm graded crushed stone aggregate), GI protection pipe light grade 15 mm bore up to 7.5 m length from earth electrode & engraving of earth marking on nearby building with CM 1:4 plate size 200 X 150 X 15 mm & painting of earth result etc. including testing on complete all as specified and directed.
pee kay construction
kailu construction co
Bharat Builder
UNITED ENGINEERING CORPORATION
Rishi Construction Co
Karan Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .