Loading…
Loading…
Tender ID
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
Tender Value
₹15.2 L
EMD Value
₹31,000
Closing Date
24 Dec 2025, 5:00 pmClosed
SM_HEALTH
GNIDA OFFICE
Supply Erection and Commissioning of 40 Tonne Capacity weight bridge including Civil and Electrical and Mechanical work etc all completed at Lakhnawali site.
2025_GNIDA_1098244_1
H.D./2025/2785-2786 DATED-09.12.2025
Open Tender
Miscellaneous Works
Fixed-rate
90 days
GREATER NOIDA
REFER TENDER DOCUMENT
5 documents required · 5 mandatory
₹840
₹31,000
26 Dec 2025
11 Dec 2025
26 Dec 2025
11 Dec 2025
24 Dec 2025
11 Dec 2025
CIVIL WORK
Excavation in foundation in ordinary soll. (Loam, clay or sand) including lift upto 1.50 M. and lead upto 30 M. and including filling watering and ramming of excavated earth into the trenches or into the space between the building and the sides of foundation trenches or into the plinth and removal and disposal of surplus earth as directed by the Engineer-in-charge upto a distance of 30 M. from the foundation trenches. (Where machine con not reach/move). SOR-20/251(a)
All kinds of soil
Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m.
All kinds of soil DSR-18/2.28.1
Plain/Reinforced Cement Concrete in Open Foundation complete as per Drawing and Technical Specifications.
RCC Grade M20 using batching plant transit mixer & manual placing MORTH-20/9.06/c/Case II
Cement Concrete with 4 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. SOR-20/279
Same as above item no. 279 but in proportion of 6:3:1 SOR-20/280
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more. DSR-18/5.22.6
M-150 Brick Work in 1:6 cement & fine sand 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour and T&P etc. requried for proper completion of the work. SOR-20/303
Same as item no. 305 but in 1:4 one cement & four Coarse sand of 2.20 F.M. mortar. SOR-20/305(A)
M-150 Brick Work in 1:6 cement & fine sand 1.25 F.M. mortar in foundation and plinth including supply of all materials, labour and T&P etc. requried for proper completion of the work. SOR-20/303
Same as item no 303 but in 1:4 one cement & four fine sand of 1.25 FM mortar SOR-20/305
Same as item no. 305 but in 1:4 one cement & four Coarse sand of 2.20 F.M. mortar. SOR-20/305(A)
As in item 303 to 307 above but in superstructure including necessary Cutting & moulding of brick as required thickness of walls not to be less than 1½ brick. Add extra labour to above items. SOR-20/309
Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer.
Using M.S. angels 40x40x6 mm for diagonal braces DSR-18/10.5.1
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee- sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). DSR-18/10.13.1
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in 25 position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete DSR-18/10.25.1
12 mm cement plaster of mix:
1:6 (1 cement 6 coarse sand) DSR-18/13.4.2
20m cement plaster of mix:
1:4 (1 cement 4 coarse sand) DSR-18/13.6.1
6 mm cement plaster of mix:
1:3 (1 cement: 3 fine sand) DSR-18/13.6.1
Distempering (first coat) with oil bound distemper of approved brand and manufacture and of required shade on undecorated wall surface to give an even shade over and including a priming coat with cement primer of approved brand and manufacture such as Berger, J&N, Shailmar, Asian Paint after thoroughly brushing the surface free from mortar dropping and other foreign matters and also including the surface even with plaster of Paris or approved synthetic materials and sand papered smooth including supply of all materials, labour, Tools & plants etc. required for proper completion of the work SOR-20/649
As in item (649) above but for every cout after the first coat. SOR-20/649+650
WEIGHT BRIDGE
Load cell, Digital-IP 68 Rated, Mounting kit, junction box, cables, Inteligent Indicator with SMS & Email facilty, Parallel Display (jumbo display), Keyboard, Civil drawings and guidance One year warranty +Next 1st Year AMC including, Printer, IP Camera's(Hik vision)-3 no's, IOT
ELECTRICAL WORK
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with plano type switch, phenolic laminated sheet, sultable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 1.8.1 Group A Point
1.14 Wiring for circult/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Metre
1.23 Supplying and fixing following plano type switch/socket on the existing switch box/cover including connections etc. as required.
1.23.1 5/6 amps switch Each 45
1.23.2 2 way 5/6 A switch
15/16 A switch
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.1.12 dsr
Supply and burying of 600mm x 600mm x 6mm G.I. plate vertically for earthing with its top at least 3 metres below ground level complete with 20mm dia G.I. pipe and funnel for watering and one earthing lead of two no. 8 to 10 SWG GI wire in 15mm dia G.I. pipe up to switch board (from appron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm square C.I. frame with hinged cover masonry housing alternate layers of charcoal/coke and salt at least 150mm thick alround etc. as per directions of Engineer-in-charge complete in all
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without 8 way (4+24), Double doorMCB/RCCB/Isolator)
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as SINGLE pole Eachrequired. 2.10.1
Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 16 sq. mm 4 core
Labour Cess and GST will be paid extra as per govt. orders
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.10 MB
PreQ_Supp_Erec_Comm_Capa_Weigh_Civil_Elec_Mecha_Work.pdf
Tender Documents • 1.06 MB
BOQ_2022812.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .