| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC | ₹2.9 L | L1 | Accepted-AOC L1 BASIS |
| 2 | Rejected-Technical PATRA TOLI NEAR MASJID KANKE RANCHI 834002 | RANCHI | RANCHI | JHARKHAND | 834002 | - | - | Rejected-Technical NOT L1 |
| 3 | Rejected-Technical | - | - | Rejected-Technical NOT L1 |
| 4 | Rejected-Technical RATU RD PISKA MORE LAXMI NAGAR DISTT RANCHI JHARKHAND 834 005 | RANCHI | RANCHI | JHARKHAND | 834005 | - | - | Rejected-Technical NOT L1 |
| 5 | Rejected-Technical | - | - | Rejected-Technical NOT L1 |
| Sl No | Description | Qty | Unit | R AND S ELECTRICALS L2 | M/S RAMRAJ CONSTRUCTION L1 | M/S MAA VAISHNO DEVI ENTERPRISES L5 | Avish Associates L4 | SEEMA CONSTRUCTION L3 |
|---|---|---|---|---|---|---|---|---|
| 1.10 | Providing and fixing of 1.1 KV grade120 sq. mm, 3.5 core XLPE aluminium armoured cable on wall surface clamped with 25/40 X 3mm ms flat clamp | 250 | Mtr. | 830 ₹2,07,500 | 830 ₹2,07,500 | 850 ₹2,12,500 | 950 ₹2,37,500 | 800 ₹2,00,000 Lowest |
| 1.20 | Providing and fixing of 1.1 KV grade 95 sq. mm, 3.5 core XLPE aluminium armoured cable on wall surface clamped with 25x3mm MS flat clamp | 100 | Mtr. | 630 ₹63,000 Lowest | 740 ₹74,000 | 975 ₹97,500 | 750 ₹75,000 | 704.5 ₹70,450 |
| 1.30 | Providing and fixing of 415 V,50 Hz, 630 A,4 pole change over switch with steel sheet enclosure | 1 | No. | 35,000 ₹35,000 | 2,900 ₹2,900 | 50 ₹50 Lowest | 15,000 ₹15,000 | 47,000 ₹47,000 |
| 1.40 | Providing & fixing of outdoor type 415 V, 400 A Bus bar chamber complete with 4 pole Copper bus bar arrangement with enclosure. | 1 | No. | 9,500 ₹9,500 | 2,900 ₹2,900 Lowest | 33,000 ₹33,000 | 39,000 ₹39,000 | 12,544 ₹12,544 |
| 1.50 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required of 120 sq.mm cable. | 2 | Nos. | 800 ₹1,600 | 560 ₹1,120 Lowest | 27,000 ₹54,000 | 2,200 ₹4,400 | 4,602 ₹9,204 |
| 1.60 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 95 sq.mm cable. | 2 | Nos. | 800 ₹1,600 | 560 ₹1,120 | 100 ₹200 Lowest | 1,900 ₹3,800 | 4,602 ₹9,204 |
| 2.00 | Total impact of GST for the purpose of CTC | 1 | No. | - | - | - | - | - |
Tender Value
₹5.5 L
EMD Value
₹6,900
Closing Date
2 May 2026, 5:00 pmClosed
SR.MANAGER EnM
ENM MAINT. SEC. CCL HQ RANCHI
Providing and fixing of power cables with all allied works at Damodar Building and Sales building at DHC CCL HQ. Ranchi
2026_CCL_358536_1
CCL/HQ/EnM/Maint./eTender Notice/2026-27/42
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
CCL HQ RANCHI
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,900
26 Jun 2026
20 Apr 2026
4 May 2026
21 Apr 2026
2 May 2026
21 Apr 2026
21 Apr 2026 - 28 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.1 | Providing and fixing of 1.1 KV grade120 sq. mm, 3.5 core XLPE aluminium armoured cable on wall surface clamped with 25/40 X 3mm ms flat clamp | 250 | Mtr. | - | - |
| 1.2 | Providing and fixing of 1.1 KV grade 95 sq. mm, 3.5 core XLPE aluminium armoured cable on wall surface clamped with 25x3mm MS flat clamp | 100 | Mtr. | - | - |
| 1.3 | Providing and fixing of 415 V,50 Hz, 630 A,4 pole change over switch with steel sheet enclosure | 1 | No. | - | - |
| 1.4 | Providing & fixing of outdoor type 415 V, 400 A Bus bar chamber complete with 4 pole Copper bus bar arrangement with enclosure. | 1 | No. | - | - |
| 1.5 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as required of 120 sq.mm cable. | 2 | Nos. | - | - |
| 1.6 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required of 95 sq.mm cable. | 2 | Nos. | - | - |
| 2 | Total impact of GST for the purpose of CTC | 1 | No. | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_371402.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.41 MB
BOQ_371402.xls
BOQ • 0.23 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .