Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹109.9 Cr 2 44 A 4 KALU SARAI HAUZ KHAS DELHI SOUTH WEST DELHI DELHI 110016 | SOUTH DELHI | DELHI | 110016 | ₹109.9 Cr |
Tender Value
₹103.0 Cr
EMD Value
₹1.0 Cr
Closing Date
29 Dec 2025, 11:00 amClosed
Comprehensive ARM and Operation of Civil, E and M Services (Internal and External), Housekeeping, Security (excluding Lift operator cum guard), Control and Command Centre, Horticulture-Landscaping Works, SWMP, STP etc. of 4608 dwelling unit of various types of Type II to Type VII and allied services at East Kidwai Nagar, New Delhi-110023
NBCC/CPG/EKN/Maintenance/2025/541
NBCC/CPG/EKN/Maintenance/2025/541
Open Tender-Domestic
Miscellaneous
New Delhi, Delhi
₹2.4 L
₹1.0 Cr
6 Dec 2025
6 Dec 2025
29 Dec 2025
29 Dec 2025
6 Jan 2026
ABSTRACT OF COST
DSR Amount including
Sr. No. Description Non-Schedule Amount (In Rs.)
Cost Index (In Rs.)
A INTERNAL WORKS
1.0 ARM of Internal Civil Works including Housekeeping etc. - 18,49,05,807.32
2.0 ARM of Electrical Installations - 4,05,76,037.00
ARM of Wet riser & Sprinkler system, drinking water & sump pump system, Fire Alarm, Detection -
B EXTERNAL Works
5.0 ARM of External Civil Works - Road, Sewer, water supply, boundary wall, Basement areas etc. - 7,22,68,546.50
6.0 Horticulture works 4,97,66,879.44
7.0 Cleaning of Sewer line 1,68,427.27
8.0 Disposal of Excess garbage 30,52,821.56
9.0 ARM of Electrical Installations - 3,64,78,675.64
C Annual civil works
10.0 Cleaning of UG tank 64,14,846.12 -
11.0 INTERNAL & EXTERNAL FINISHING 25,71,829.55 19,16,10,019.60
12.0 Civil works for Maintenance 79,97,575.59 2,51,10,297.66
D Annual Electrical works
15.0 Maintenance of CCC 4,64,15,056.21
18.0 CAMC of Boom Barrier 79,56,747.43
19.0 AMC for GEYSERS 22,26,613.24
20.0 AMC for Chimney 20,21,530.44
21.0 AMC of Swachh Aawas App and Web application including server charges 12,13,753.72
22.0 AMC of Complaint Management App and Web application including server charges 9,28,301.12
Digitally signed by VARUN
F Watch & Ward
G Special Repair
Total Cost (DSR Amount + Non-Schedule items Amount) in Rs. 1,02,99,12,995.00
Say 103 Crores
Digitally signed by VARUN
NBCC (INDIA) LIMITED
Comprehensive ARM and Operation of Civil, E&M Services (Internal & External), Housekeeping, Security (excluding Lift operator cum guard), Control & Command Centre, Horticulture/Landscaping Works, SWMP, STP etc. of 4608 dwelling unit of various types of Type II to
Type VII and allied services at East Kidwai Nagar, New Delhi-110023
BILL OF QUANTITIES
DSR CIVIL-2023 RATE IN RS. AMOUNT IN RS
S.No. DSR ELECT.-2025 Description of item of work Unit QTY
DSR NS DSR NS
Maintenance of Residential Building
1.00 SH - I: CIVIL WORKS i/c SANITARY, WATER SUPPLY & SEWERAGE SYSTEM
Maintenance and upkeep of all internal civil assets i/c safety, security of all services at GPRA campus,complete with all materials labour, T&P , machines ,
trucks etc. as required on all days including Sunday and holidays comprising following operation as per the details of quarters, Buildings, as per
direction of the engineer in charge and as per enclosed GCC, Special & other conditions, specifications etc.
Cleaning & repairing of lift lobby, staircases, etc, daily sweeping by machine and / or manually and picking up of papers, dry leaves & garbage etc. wet
mopping of floors twice in a week and mechanised wet mopping periodically in every 6 months, Lift lobby, staircase at least once in every week with R-2
Chemical and terrace cleaning once in a month complete to the entire satisfaction and as per directions of Engineer-in-charge.
Antitermite treatment, rodant, cockroach & insect treatments etc. complete to the entire satisfaction and as per directions of Engineer-in-charge.
Maintenance, repairing and cleaning of chajjas, roofs, expansion joints etc. and removing of cobwebs, beehives, vegetation including disposal of silt,
vegetation, malba, waste garbage etc. to the authorized dumping ground outside the campus at the location approved by MCD/NDMC complete to the entire
1.1 NS satisfaction and as per the direction of Engineer-in-Charge.
Maintenance, repairing and fixing of damaged doors, windows, ventilators of steel, aluminium, wood, PVC including replacement of glass panes etc. at all
floors & heights and replacement of necessary fittings & fixtures of approved make and quality, wherever required to keep them in proper functional
conditions to the entire satisfaction and as per direction of Engineer-in-charge.
Maintenance and repair of plumbing system for the entire campus including stopping leakages or over flow of water from PVC/RCC over head tanks,
cisterns and replacement of damaged fittings i/c CP Brass fitting, ball cocks and G.I. fittings etc. to keep the entire water supply system efficient and
functional to the entire satisfaction and as per direction of Engineer-in-charge.
Maintenance and repair of internal & external plaster, flooring, masonry & RCC works, pointing on roof tiles, patch plaster on area upto 2.5 sqm, CC gola
i/c fixing of W.C. seat, gully trap, W.C trap, floor traps and sealing of leakages from gully trap, W.C trap, floor trap, drainage and vertical stacks etc. and
restoration of existing finishing in the affected areas to the entire satisfaction and as per direction of Engineer-in-charge.
Welding by single/3 phase electric welding machine including transportation of electric welding machine at site to weld broken grills, hinges, doors,
windows, gates, railings and any other steel work of dwelling units, offices, etc.complete as per direction of Engineer-in-charge.
Investigating causes of seepage/dampness/leakage from roof, wall, floors, pipes of all kinds etc. Dismantling existing affected portion, arranging required
materials, labours, T&P including taking all necessary measures, rectification complete in all respect in time bound manner as per saReplacement of broken,
damaged, edge depressed & reverse flow floor tiles including base mortar/ adhesive to match with surrounding colour tiles & colours shades as per
specification & complete satisfaction to the Engineer-In-Charge.tisfaction of Engineer-in-charge i/c making arrangement of lift/ladder or jhulla as per
required heights.
Fabrication works in Main Gates, Stair cases, i.e realignments, additional tower bolts, sliding bolt including making holes & welding wherever required.
Cutting RCC & providing hooks for additional ceiling fans including making repairs to original condition.
1.2 Closing holes in walls, ceilings, floors etc including repairing with cement mortar or some other suitabe materials to prevent entry of Rats & others
Any other miscellaneous works connection with above as per direction of Engineer-in-charge.
Assigning all the complaints received from any source to the worker of respective trade and get back confirmation from the allotee w.r.t. disposal of
complaint on daily basis.
All civil works, housekeeping etc as mentioned above or elsewhere in tender are to be carried out in all towers and basements.
Cleaning & repairing of basement parking spaces, etc, daily sweeping by machine and/or manually and picking up of papers, dry leaves, grass, earth,
brick bats, stone pieces, etc. disposing of resulting rubbish/ garbage etc, including removing of garbage from garbage bins to the soild waste
management in the campus complete to keep the entire basement neat and clean including manually wet mopping of floors and mechanised wet mopping
periodically cleaning once in every third day complete to the entire satisfaction and as per directions of Engineer- in - charge.
Running and Maintenance of NBCC service centre (Main control command center) at Type IV basement East Kidwai Nagar Complex by providing & operating
24x7 intigrated facility management centre (help desk) with all necessary manpowers, hardware and software for lodging day to day complaints and duly
intigrated with NBCC Sewa kendra wherever required wherein broadly the following jobs are required to be performed (Campus and peripherial including
operating staff necessary consumables, computer, software, internet/broadband connection shall be arranged by the contractor at his cost.)
Downloading the complaints received on complaint app/IVRS/Emails on daily basis.
Recording the complaints in register received at service centres in person or through telephone and issuing acknowledgement with complaint no. i/c
assigning the complaint to the workers of respective trade.
Uploading all the complaints received at the service centre in the IVRS/Emails/E- sewa system/complaint app on daily basis.
Uploading the status of attending of the complaints on daily basis on IVRS/Email/E-sewa system/complaint app so that the backlog is not more then
Provide automated status/completion of complaints to allottes, Provide system to allow feedback by allottes regarding complaints Generate online reports
for monitoring by Engineer-in-Charge.
Preparing the abstract of attended / unattended complaints on daily, weekly and monthly basis and submitting the same with reasons of unattended
complaints, action plan of completion to the Engineer-in-charge of the service centre or his authorized representative.
Generation of vacation/ occupation/inventory reports from IVRS/ Emails/E-sewa.
Any other miscellaneous works connection with above as per direction of Engineer-in-charge.
Super Structure - Towers
a Type II (60 flats in each tower, Total 7 towers) 252.00 62,394.80 1,57,23,489.35
b Type II (90 flats in each tower, Total 4 towers) 144.00 93,592.20 1,34,77,276.58
Digitally signed by VARUN
e Type V (G+6 towers, Total 13 towers) 468.00 45,365.62 2,12,31,107.90
f Type V (G+14 towers, Total 6 towers) 216.00 97,212.03 2,09,97,799.02
SUB TOTAL OF INTERNAL CIVIL WORK INCLUDING HOUSEKEEPING - 18,49,05,807.32
2 SH-II :: INTERNAL ELECTRICAL INSTALLATIONS
All inclusive AR & maintenance, upkeep of all electrical internal installations, Lights, Fans, Geysers etc. as per details below at residential units east kidwai
nagar, New Delhi in 24x7 for all days in a month i/c sundays and holidays complete with materials, and as per direction of Engineer -in-Charge.
• Light points/Fan pts/ Ex-fan pts/ Call bell pts.
• 5 amp plug points
• 15 amp power plug points
• 25/32 amp AC plug points
• Telephone outlet, TV Outlet
• Telephone wire, TV Wire
• control/communication cables/wires, connectors
• OFC, ONT (Optical Network Terminal) device & Box, jack panel
• Splitter boxes, Switches, racks
• LED light fittings
• All type of light fittings
• Ceiling fans 1200 mm/900mm
• Ex-fans 250/300/450mm
• Water Heater Geyser 25 ltrs. and 3 Ltrs (Instant)
• SPN & TPN MCB DB’s with MCB’s, DP, TPN, RCCB
• Rising mains, Bus Bars, Bus duct and Tap off box of different ratings
• LT,HT Cables & Cables trays of different size
• Solar Street Lights, compound lights with LED, all decorative light fittings, control gears, Solar panels, Batteries etc.
• All type of feeder pillars with switch gears etc.
• All HT, LT, UG & OFC cables.
• All LT/HT panels i/c RMU ,UPS Panels, Main LT panels , lighting panel, Lift panels, Blocks panels, Common service panel etc.
• Domestic and fire pump houses.
• DG set with cooling towers and electric sub-stations.
• Lightning Arrestor System
• Earthing system
• Telephone exchange, Intercom, Public address system, Fire alarm system, CC TV Surveillances system, Water Control & monitoring system.
• Boom barriers & all Security posts with security equipment’s.
• Control rooms having control of CCTV, Telephone, and water monitoring system, boom barriers, security system.
• Automation of DG sets electric supply, Ventilation system, domestic water, all water/ drainage/ flushing/ sewage/ sump pump etc.
• OFC network with its associated equipment’s for wifi, telephone, data, TV etc.
• And others services as required to keep the entire system good & operational & directed by Engineer-in-charge.
Any other works in connection with the smooth operation & maintenance work not mentioned above, but required to be carried out with in the cost and/
or also as per direction of the Engineer -in - charge.
pump house, UG Tank
Any other pumpset/ other installation
any other work in connection with the smooth operation & maintenance work not mentioned above, but required to be carried out within the cost and/ or
also as per direction of engineer-in charge.
a Type II (60 flats in each tower, Total 7 towers) 252.00 14,820.89 37,34,864.36
b Type II (90 flats in each tower, Total 4 towers) 144.00 22,231.34 32,01,312.31
e Type V (G+6 towers, Total 13 towers) 468.00 8,437.62 39,48,804.74
f Type V (G+14 towers, Total 6 towers) 216.00 18,080.61 39,05,411.28
h Type VII (G+6, Total 9 towers) 324.00 17,057.27 55,26,554.77
SUB TOTAL OF INTERNAL ELECTRICAL WORK - 4,05,76,037.00
3 SH III:- ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING WATER & SUMP PUMP SYSTEM, FIRE ALARM, DETECTION SYSTEM, Intercom ETC.
All inclusive AR & maintenance of fire-fighting system i.e. including providing services for operation of manual fire alarm ,detection system, down comer
3.1 system, Pumps intercom & Lift intercom, 24x7 on all days of the year including Holidays as per terms and conditions attached i/c periodical fire testing,
mock drill & obtaining fire clearance certificate as & when becomes due.
Digitally signed by VARUN
3.2 All water lines, motor, pumps, electrical wiring, intake, any other Pump/machinery installed etc.
Any other works in connection with the smooth operation & maintenance work not mentioned above, but required to be carried out with in the cost and/
3.3 NS or also as per direction of the Engineer-in-charge.
SUB TOTAL OF ARM OF WET RISER & SPRINKLER SYSTEM, DRINKING WATER & SUMP PUMP SYSTEM, FIRE ALARM, DETECTION SYSTEM,
4 SH-IV: EXTERNAL CIVIL WORK
Maintenance and upkeep of all external assets and services i/c safety of all services in common areas, service centre, under ground & over head tanks at
GPRA campus,complete with all materials labour, T&P , machines , trucks etc. as required on all days including Sunday and holidays comprising following
operation as per the details of quarters, Buildings,external services, as per direction of the engineer in charge and as per enclosed GCC, Special & other
conditions, specifications etc.
Cleaning & Maintenance of garbage bins i/c cleaning garbage chamber twice/thrice in a day or as required by removing collected garbage from garbage
bins, disposing the garbage at soild waste management garbage yard by using the covered mechanical vehicle, complete to the entire satisfaction of
Engineer - in - charge Maintenance and operation of water supply grid and valves including unfiltered water supply line in the entire campus to keep the
water supply system efficient and operational at all times complete to the entire satisfaction and as per direction of the Engineer - in - Charge.
NS Sweeping and wet mopping of Electrical Sub-Stations, pump house, sewege treatment plant, adjoining open area, public toilet, pavements, basement
parking etc. daily including washing basment parking once in a week complete to the entire satisfaction and as per direction of Engineer -in- charge.
Maintenance, repair of boundary wall i/c M.S grill, all items installed in Central park like sitting benchs, children play equipments etc. as an when
Fogging & Anti larva spray in whole campus including towers, basements, green areas, pathways, roads, driveways etc. as & when required and as per the
direction of Engineer-in-charge.
Welding by single/3 phase electric welding machine including transportation of electric welding machine at site to weld broken grills, hinges, doors,
windows, gates, railings and any other steel work of offices, shops, parks, boundary walls etc.complete as per direction of Engineer-in-charge.
Cleaning & repairing of Central Road/Roads/Gurudwara Road, cycle track, pavements, footpaths, walking tracks in lawns/park , open areas, storm water
drains, floors of common areas , spaces, etc,of full campus daily sweeping by machine and / or manually and picking up of papers, dry leaves, grass,
earth, brick bats, stone pieces, etc. and cutting grass from the edges of Footpaths, surrounding of building, open areas, etc, inside the campus and
disposing of resulting rubbish/ garbage etc, including removing of garbage from garbage bins to the solid waste management plant of EKN campus to keep
the entire campus neat and clean including wet mopping of floors and mechanised wet mopping periodically cleaning once in a month complete to the
entire satisfaction and as per directions of Engineer- in - charge.
Periodical cleaning & Maintenance of sewerage & drainage network by using Pressure jetting machines twice in a year or more, if required i/c desiliting of
gully traps, manholes, gratings, chocked sewer line, rain water harvesting pits of whole campus, including all the sewer pipes lines, SW piped/coverd
drains and rain water pipe of all size twice in a year to the entire satisfaction of Engineer - in - Charge.
Running and Maintenance of NBCC service centre (Main control command center) at Type IV basement East Kidwai Nagar Complex by providing &
operating 24x7 intigrated facility management centre (help desk) with all necessary manpowers,hardware and software for lodging day to day complaints
and duly intigrated with NBCC Sewa wherever required wherein broadly the following jobs are required to be performed (Campus and peripherial
including operating staff necessary consumables, computer, software, internet/broadband connection shall be arranged by the contractor at his cost.)
Recording the complaints in register received at service centres in person or through telephone and issuing acknowledgement with complaint no. i/c
assigning the complaint to the workers of respective trade.
Any other miscellaneous works connection with above as per direction of Engineer-in-charge.
Cleaning rubbing scrubbing with the help of scrubbing machine having nylon brushes with the help of detergent to remove the stains of dust, furniture
mopping etc. on mosaic, tile, cement concrete flooring all complete as per direction of Engineer-in-charge.
Investigating causes of seepage / dampness/ leakage from , valve, pipes of all kinds etc. Dismantling existing affected portion, arranging required
materials, labours, T&P including taking all necessary measures, rectification complete in all respect in time bound manner as per satisfaction of
Engineer - in - charge i/c making of all arrangement of T & P required all complete.
Replacement of broken, damaged, edge depressed & reverse flow floor tiles including base mortar/ adhesive to match with surrounding colour tiles &
colours shades as per specification & complete satisfaction to the Engineer - In- Charge.
Fabrication works in Main Gates, i.e realignments, additional tower bolts, sliding bolt including making holes & welding wherever required.
Closing holes in walls, ceilings, floors etc including repairing with cement mortar or some other suitabe materials to prevent entry of Rats & others
All civil works, water supply system works, housekeeping etc. as mentioned above or elsewhere in tender are to be carried out in all basements.
Any other miscellaneous works connection with above as per direction of Engineer-in-charge.
All roads, Sewerline, water supply line, boundary wall, RWH system etc. (Total area is taken as 47300 sqm (Max.)
5 NS Subject: Comprehensive Operation and maintenance of 2 nos. sewage treatment plant (1x1500KLD + 1x650KLD) based on SBR technology at GPRA Complex, Kidwai Nagar (East), New Delhi-110023.
5.1 comprehensive operation and maintenance of the 2 no. STP plant (1x1500KLD + 1x650KLD) 24*7hours
Maintenace, Repairing including major & minor all type of maintenance and all instrument installed should be kept in operation and in good health at the
satisfaction of Engineer Incharge
Digitally signed by VARUN
Supply of various chemical, consumables etc. for plant operation for 2 nos. sewage treatment plant (1x1500KLD + 1x650KLD) based on SBR
technology at GPRA Complex, Kidwai Nagar (East), New Delhi-110023. are followings.
iii Jaggery Kgs. 360 89.00 32,040.00
iv Bio Culture Ltr 108 628.00 67,824.00
v Sodium Hypo Chloride Ltr. 64800 29.00 18,79,200.00
vi Salt for Softener KG 28800 12.00 3,45,600.00
viii Multi grade filter (Media), once in 2 years Kgs. 39000 11.00 4,29,000.00
ix Pebble & Gravel for Activated carbon filter, once in 2 years Kgs. 12000 11.00 1,32,000.00
x Activated carbon for activated carbon filter, once in 2 years Kgs. 6000 96.00 5,76,000.00
xi Softener Resin, once in 2 years Kgs. 12000 195.00 23,40,000.00
Lab Chemicals & consumables.
Daily Lab testing of Inlet and Outlet water at Sewage Treatment Plant (BOD, COD, TSS, ph, Hardness, TDS, Total Coliform, Oil & Grease, etc.)
1. Test will be done on daily basis of inlet/outlet/treated water/soft water.
2. Frequency of testing of treated water on half yearly basis from NABL approved laboratory is also included in this price.
xii Non-DSR 3. Cost of all chemicals to be used in testing and cost of calibration including maintenance & replacement of damage part of lab equipment shall be included month 36 35,000.00 12,60,000.00
with in the quoted rates.
4. Test record will be maintained on daily basis.
5. Testing of Domestic water from NDMC on half yearly basis in contractors scope within the quoted rates.
NOTE: The contractor will maintain a regular IMIR (Inward Material Inspection register) for the cosumables.
Following items will be replaced in case these are damaged and non repairable as per direction of Engineer in Chage complete in all respect.
xiii Electrical -spare parts
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing
MCB DB complete with connections, testing and commissioning etc. as required.
2.10.5 Triple pole and neutral NOS. 10 1,228.00 12,280.00
NS Over Load Relay 5 amp - 8 amp Nos. 5.00 2028 10140
NS Over Load Relay 10 amp - 16 amp Nos. 5.00 2535 12675
NS Over Load Relay 12.5 amp - 20 amp Nos. 5.00 1859 9295
NS Over Load Relay 6.3 amp - 10 amp Nos. 5.00 1690 8450
NS Over Load Relay 1 amp - 1.6 amp Nos. 5.00 1690 8450
NS Over Load Relay 20 amp - 32 amp Nos. 5.00 4648 23238
NS Over Load Relay 0.8 amp - 1.25 amp Nos. 5.00 2113 10563
NS Over Load Relay 0.9 amp - 1.5 amp Nos. 5.00 1944 9718
NS Contactor, 12 amp Nos. 5.00 1690 8450
NS Contactor, 09 amp Nos. 5.00 1352 6760
NS Contactor, 16 amp Nos. 5.00 1859 9295
NS Contactor, 32 amp Nos. 5.00 5577 27885
NS Star Delta Timmer Nos. 5.00 1944 9718
NS PLC with programing Nos. 2.00 152100 304200
NS HMI with programing NOS. 2.00 50000 100000
NS Indicating lights, 220 Watt Nos. 20.00 338 6760
NS Selector Switches Nos. 25.00 423 10563
NS Mechanical parts & Spares Blower parts & Spares
NS Bearing , for 335 m3 blower Nos. 3.00 6760 20280
NS Bearing , for 480 m3 blower Nos. 3.00 25350 76050
NS Bearing , for 770 m3 blower Nos. 3.00 28730 86190
NS Bearing , for 1200 m3 blower Nos. 3.00 29474 88421
NS Gear set , for 335 m3 blower Nos. 3.00 30420 91260
NS Gear set , for 480 m3 blower Nos. 3.00 40560 121680
NS Gear set , for 770 m3 blower Nos. 3.00 50700 152100
NS Gear set , for 1200 m3 blower Nos. 3.00 54080 162240
NS Rotor for , 335 m3 blower Nos. 3.00 33800 101400
NS Rotor for , 480 m3 blower Nos. 3.00 47320 141960
NS Rotor for , 770 m3 blower Nos. 3.00 57460 172380
NS Rotor for , 1200 m3 blower Nos. 3.00 64220 192660
NS Packing for 350 m3 blower Nos. 12.00 1622 19469
NS Packing for 480 m3 blower Nos. 12.00 1622 19469
NS Packing for 770 m3 blower Nos. 12.00 1622 19469
NS Packing for 1200 m3 blower Nos. 12.00 1622 19469
NS Belt ( flat belt ) for 335 m3 blower Nos. 24.00 845 20280
NS Belt ( flat belt ) for 480 m3 blower Nos. 24.00 1183 28392
NS Belt ( flat belt ) for 770 m3 blower Nos. 24.00 1268 30420
NS Belt ( flat belt ) for 1200 m3 blower Nos. 24.00 1352 32448
NS Oil seal for 335 m3 blower Nos. 12.00 3972 47658
Digitally signed by VARUN
NS Oil seal for 480 m3 blower Nos. 12.00 3972 47658
NS Oil seal for 770 m3 blower Nos. 12.00 4563 54756
NS Oil seal for 1200 m3 blower Nos. 12.00 4563 54756
NS Safety valve for 335 m3 blower Nos. 3.00 6760 20280
NS Safety valve for 480 m3 blower Nos. 3.00 6760 20280
NS Safety valve for 770 m3 blower Nos. 3.00 6760 20280
NS Safety valve for 1200 m3 blower Nos. 3.00 6760 20280
NS NRV for 335 m3 blower Nos. 3.00 5070 15210
NS NRV for 480 m3 blower Nos. 3.00 5915 17745
NS NRV for 770 m3 blower Nos. 3.00 6760 20280
NS NRV for 1200 m3 blower Nos. 3.00 8450 25350
NS Re-Winding of the Motors Capacity in Horse Power 0
NS Bush for Motors Capacity in Horse Power 0 0
NS Shaft for Motors Capacity in Horse Power
NS Impeller for Pumps Capacity in Horse Power
NS Fan ( Backward curve blade ) Capacity in Horse Power 0 0
NS Fan Cover Capacity in Horse Power
NS Connection Plate Capacity in Horse Power
NS Connection Box Capacity in Horse Power
NS Glade Plate Capacity in Horse Power
Digitally signed by VARUN
NS Coupling Set ( Tyre Coupling )
NS Capacity in Horse Power
NS Coupling Set ( Star Coupling ) Capacity in Horse Power 0 0
NS Silicon Seal Capacity in Horse Power 0 0
NS OZONATOR: QUARTZ TUBE NOS. 24 7,538.00 1,80,912.00
NS OZONATOR: HT Transformer NOS. 16 17,817.00 2,85,072.00
NS OZONATOR: ozone card NOS. 16 16,447.00 2,63,152.00
NS OZONATOR: seeds kg 150 4,386.00 6,57,900.00
NS OZONATOR: ozone cell complete set 2 24,670.00 49,340.00
Supply, installation, testing and commissioning of Variable Frequency Drive (VFD) for Decanter operation of STP Plant.
Rating: 0.75 KW/1 HP
CHASSIS/IP20, IE2 2.4% Temp. 40 degree C
Sub-Total Of STP Works 32,790.00 3,52,09,779.39
6 ANNUAL RUNNING & OPERATION OF EXTERNAL ELECTRIFICATION, ELECTRIC SUB-STATION EQUIPMENTS,DG SET ON GRID SYSTEM ETC.
All inclusive AR & maintenance, upkeep of all electrical external installations, Solar Street light, street light & other fancy (Decorative) external light etc. in
the residential campus east kidwai nagar, New Delhi in 24x7 for all days in a month i/c sundays and holidays complete with materials (excluding
replacement of damaged battery), and as per direction of Engineer -in-Charge. Any other works in connection with the smooth operation & maintenance
work not mentioned above, but required to be carried out with in the cost and/ or also as per direction of the Engineer -in - charge.
All inclusive AR & maintenance i/c providing services for operation of electric sub- station equipments and DG set,including cooling towers on all days of the
year including Sunday & Holidays as per terms and conditions
i)Running, Operation & AR & maintenance of - 1500 KVA, 1010 KVA and 750KVA DG sets, stand by DG sets on all the days including
Sundays & Holidays complete with all materials i/c Diesel oil etc as per terms and conditions attached.
ii) ARM of Electrical equipments:
NS Dry Type Transformer (2000KVA/1600KVA)
LT Main Panel LT main common service panel with PLC control and DG automation system
LT block panels
LT common service panels LT lighting panel
LT meter panels
LT rising mains with main adaptor switch
LT lifts panels at top roof Ventilation panel & starters
Ventilation fan (for basement fresh air & exhaust, lift well & staircase pressurization)
UPS lighting panels, Domestic water panels, Sump-Pump Panel, sewerage panel, 15/10/1 KVA three/Single phase UPS, Submersible pump for sump pits,
Ventilation Panels, Panel for Boom Barrier & Access Control System.
Periodically preventive maintenance of all equipemnts shall be essentially carried out by deploying the required team to check each & every point related to
Electrical, Mechanical, pumps items etc. and maintained the record.
Any other item(s)/ work(s) in connection with above shall be carried out as per direction of the Engineer-in-charge.
Digitally signed by VARUN
Consumtion of fuel (Diesel) in DG sets in case of power cut as per direction of Engineer In-charge. The agency has to maintain the diesel consumption
register which shall be countersigned by Engineer In-charge. (RATES AS PER PPAC Retail Selling Price of Diesel on 21-10-2025)
SUB TOTAL OF ANNUAL RUNNING & OPERATION OF EXTERNAL ELECTRIFICATION, ELECTRIC SUB-STATION EQUIPMENTS, DG SET ON GRID
7.0 HEAD-I : HORTICULTURE WORKS
Complete maintenance of the entire garden features having as per yard stick in the garden area i.e. lawn trees, shrubs, herbs, edge, flower beds, foliages,
creepers etc. including hoeing,weeding, pruning, replacement of plants, gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush
cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and
maintenance of other garden related works as directed by office-in-charge (Including Cost of Good Earth, Manure, Fertilizer, Insecticide, Pesticide, lawn
mover and brush cutter with fuel and other T & P material/articles) to maintain the plants, hedge and lawns in good and healthy conditions at all the time
during the maintenance period as mentioned in general terms and conditions.
Entire residential units of Type-II, III, IV, V, VI, VII campus and inside the compound wall and outer periphery of front side compund wall & at entrance
gate etc. (Rates are for total Green Area 1,13,600 Sqm however the payment will be made in ratio of the area in hand for maintenance)
ii NS Providing & Fixing of irrigation line HDPE sprinkler Nos. 100.00 413.00 41,300.00
iii NS Providing & Fixing of irrigation line HDPE Popup sprinkler Nos. 100.00 1,545.80 1,54,580.00
TOTAL OF HORTICULTURE works 4,97,66,879.44
8 CLEANING OF SEWER LINE BY JETTING SEWER CLEANING MACHINE
Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with
pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and
partial desilting of manholes and dechocking of sewer lines. Dechocking and flushing of sewer line from one manhole to another by high pressure jetting
system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth.
9 DISPOSAL OF GARBAGE ETC.
"Disposal of moorum/ building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting,
unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-Charge.
Note - Item to be applicable in urban areas having directions for restricted hours for movement/plying of load carriying motor vehicle of 3.5 cum or more."
(only waste material which can not be recyled at in house Solid waste treatmnet plant or in case SWMP is not working)
10 Day-Today CIVIL WORKS
CLEANING OF UNDER GROUND TANK
Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of silt and rubbish, all as per direction of Engineer-in-
Charge. The cleaning shall consist following operations:-
(i) Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and other deposits.
a 14.78 (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. sqm 61,181 104.85 64,14,846.12
(iii) Chlorination of RCC internal surface by liquid chlorine.
(iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface.
(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge.
11 INTERNAL & EXTERNAL FINISHING
i NS Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. sqm 61764.83 188.00 1,16,11,788.60
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to
prepare the surface even and smooth complete.
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and
iii NS manufacture, including applying additional coats wherever required, to achieve even shade and colour. sqm 13,70,207.60 53.00 7,26,21,002.55
Old work (One or more coats)
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,
iv NS including applying additional coats wherever required, to achieve even shade and colour. sqm 3,49,181.68 91.00 3,17,75,533.06
Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture,
v NS including applying additional coats wherever required, to achieve even shade and colour. sqm 87,295.42 131.00 1,14,35,700.09
vi 13.87 White washing with lime to give an even shade :
via 13.87.1 Old work (One or more coats) sqm 37,254.20 22.68 8,44,839.98 -
vii NS Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
viii NS One or more coats on old work. sqm 144800.00 91.00 1,31,76,800.00
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface
x NS Melamine polishing on wood work (one or more coat). sqm 14000.00 117.00 16,38,000.00
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat,
xi 13.52.2 preparation of surface, etc. complete. sqm 7400.00 233.38 17,26,989.57
On concrete work
SUB TOTAL OF INTERNAL & EXTERNAL FINISHING SUB TOTAL 25,71,829.55 19,16,10,019.60
12 Civil works for Maintenance
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with
a 9.1.3 dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). cum 6 82749.3795 4,96,496.28 -
Kiln seasoned and chemically treated hollock wood
Digitally signed by VARUN
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer
b 10.25.2 using structural steel etc. as required. kg 2000 171.30 3,42,600.00 -
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Providing and laying machine cut, mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complet as per
architectural drawings, with 18 mm thick stone slab laid over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed
c 11.51.1 with white cement slurry @ 4.4 kg/sqm including pointing with white cement slurry admixed with pigment to match the marble shade including rubbing, sqm 20 6553.56074 1,31,071.21 -
curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
18 mm thick Italian Marble stone slab, Perlato, Rosso verona, Fire Red or Dark Emperadore etc.
Providing & fixing wardrobe/cabinets as per design factory made 19 mm thick ISI marked commercial board laminated both sides with 1.0 mm thick
decorative laminate on doors and all other inner and outer sides to be laminated with matching color plain laminates of 0.8 mm matt finish including all
stainless steel fitting like, hinges, SS pipes for hanging, sliding trousers rack, laminated drawers,handles, locks, bolts, magentic catcher drawer rails etc.
complete in all respect or as per direction of EIC. (Only face area to be measured for payment)
Supplying, Installation, Testing and commissioning of butterfly valve (wafer type) with electric operated actuator. Design standard BS5155 :IS13095.
Compatible to be inserted between flang PN-10, Maximum working temperature-90 'C, Maximum working pressure-10 bar, Hydrostatic: 11 bar and 15 bar
seat test pressure.
Supplying, Installation, Testing and commissioning of butterfly valve (wafer type) with electric operated actuator. Design standard BS5155 :IS13095.
Compatible to be inserted between flang PN-10, Maximum working temperature-90 'C, Maximum working pressure-10 bar, Hydrostatic: 11 bar and 15 bar
seat test pressure.
Supplying, Installation, Testing and commissioning of Water Level Indicator Unit (Model - Flexibell) : Supplying display unit of
continuous wireless water level indicator with 7-segment LED display (56mm height) to indicate water level of single/ multiple tanks (Maximum 6 Tanks)in
percentage with 1 % resolution. It will also indicate Flow status and audio/ visual alarm for Full/Low/ Overflow condition. ( Only Receiver/ Display unit
without transmitters. Water level data Transmitters unit will be charged separately) [Size in mm: 426(H) x225(W)x95(D)]
Supplying, Installation, Testing and commissioning of Digital Sump Transmitter with 25ft Sensor Length: Supplying battery powered
h Non-DSR water level data transmitter with water level sensors to measure water level with 1% resolution and flow/ overflow status and transmit the data wirelessly each 6 13,162.00 - 78,972.00
to controller cum receiver unit.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections
and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up
the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free,
straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless
i 21.1.2.2 steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for kg 600 629.666247 3,77,799.75 -
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required
including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of
opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40
Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia. wire and 1.4mm wide aperture with matching wood beading
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window
sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give
high gloss finish etc. complete at all levels.
Granite stone slab of colour black, Cherry/Ruby red
Area of slab over 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window
sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give
high gloss finish etc. complete at all levels.
Granite stone slab of all colour and texture except black, Cherry/ Ruby red
Area of slab over 0.50 sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive,
including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in
marble/Granite/stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles with necessary screws etc. complete (best
make of approved quality).
p (i) NS Providing & Fixing of 6mm thick Bison Board Ceiling Tiles as per direction of EIC. sqm 2797.02 313.00 - 8,75,467.26
Providing & Fixing of 15mm thick flase ceiling tiles at all heights with integral densified calcium silicate reinforced with fibre and natural fibre false ceiling
tiles of size 595x595 mm of approved texture, design and patterns having NRC (NoiseReduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light
p (ii) NS reflectance of 85% (minimum), non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6&7), humidity resistance of 100%, thermal each 2500.00 345.00 - 8,62,500.00
conductivity<0.043W/mK as per ASTM 518:1991, in true horizontal level on the exisiting frame work consisting of T-sections and L-sections suitably fixed
according to tile size as per direction of EIC.
12 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
15 mm cement plaster on the rough side of single or half brick wall of mix
1:6 (1 cement: 6 fine sand)
12mm cement plaster finished with a floating coat of neat cement of mix
1:4 (1 cement: 4 fine sand)
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
Providing and applying 2.5 mm thick road marking strips (retro reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi
automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by
experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc.
complete as per direction of Engineer-in-charge and accordance with applicable specifications.
Digitally signed by VARUN
Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and
making good the walls and floors :
100 mm inlet and 100 mm outlet
Sand cast iron S&S as per IS: 3989.
w 18.78 Making chases up to 7.5x7.5 cm in walls including making good and finishing with matching surface after housing G.I. pipe etc. Mtr 94.00 170.50 16,027.00 -
DESIGN, ENGINEERING, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF PUMP HOUSE AUTOMATION For DOMESTIC TANKS ONLY. (Type-6 &
7, Type-5A & B, Type-4, Type 2 and 3)
Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade
z 17.32.4 with 6 mm thick hard board backing : Each 57.00 2077.22 1,18,401.47
Rectangular shape 1500x450mm
aa NS Suppling & fixing of 25 MM THICK PVC JAALI with all screws/fasteners and accessories, complete as per direction of EIC. sqft 500.00 274.00 - 1,37,000.00
Providing and fixing white vitreous china Parryware floor mounted Bristol (CODE C8492) OR EQUIVALENT water closet of approved shape including
ab NS providing & fixing white vitreous china cistern with dual flush including seat cover, and cistern fittings, nuts, bolts and gasket etc complete. fitting, of Each 30.00 8,106.00 2,43,180.00
flushing capacity 3 litre/6litre (adjustable to 4 litre/8 litres),
ac NS Providing and fixing Rectangular HDPE Water Tank of 100 Ltrs. Capacity and complete with cover, nut bolts etc. of approved makes. Each 10.00 2,741.00 27,410.00
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st
ad 9.21.1 class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: SQM 147.00 2374.61 3,49,067.58
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame,
ae 9.17.1 backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): SQM 900.00 796.90 7,17,206.18
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame,
af 9.17.2 backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): SQM 400.00 1013.25 4,05,300.81
Treatment of complete quarter area including all wooden cabinets, almirahs, kithcen, toilets, hall, bedroom and balconies using injection as well as spray
ag NS chemicals. each 150 4,112.00 6,16,800.00
Note: The treatment shall cover termites, pest, wood borers etc. in complete quarter. Nothing extra shall be paid for any recurring issue in the quarter
Type 2 & 3 quarter
Treatment of complete quarter area including all wooden cabinets, almirahs, kithcen, toilets, hall, bedroom and balconies using injection as well as spray
ah NS chemicals. each 150 4,797.00 7,19,550.00
Note: The treatment shall cover termites, pest, wood borers etc. in complete quarter. Nothing extra shall be paid for any recurring issue in the quarter
Type 4 & 5 quarter
Treatment of complete quarter area including all wooden cabinets, almirahs, kithcen, toilets, hall, bedroom and balconies using injection as well as spray
ai NS chemicals. each 75 5,482.00 4,11,150.00
Note: The treatment shall cover termites, pest, wood borers etc. in complete quarter. Nothing extra shall be paid for any recurring issue in the quarter
Treatment of complete quarter area including all wooden cabinets, almirahs, kithcen, toilets, hall, bedroom and balconies using injection as well as spray
aj NS chemicals. each 30 6,853.00 2,05,590.00
Note: The treatment shall cover termites, pest, wood borers etc. in complete quarter. Nothing extra shall be paid for any recurring issue in the quarter.
Supplying and fixing of Stainless Steel trays (SS-316 Grade), minimum 1.5 mm thickness, below basement shafts and expansion joints to prevent spillage
ak Non-DSR of water in the basement area including all supporting arrangement like GI tie rod, Bullet Fasteners, Solid/Slotted GI angles for supports complete in all sqm 100 4,215.00 4,21,500.00
respect or as per direction of Engineer In-Charge.
Supplying and fixing of trays made up of fibre sheet 1.5 mm thickness along with M.S. strips 1.5 mm thickness, below basement shafts and expansion joints
al Non-DSR to prevent spillage of water in the basement area including all supporting arrangement like GI tie rod, Bullet Fasteners, Solid/Slotted GI angles for supports sqm 100 2,741.00 2,74,100.00
complete in all respect or as per direction of Engineer In-Charge.
am NS Cleaning of Rain Water Harvesting pits by manually complete in all respect upto the satisafaction of Engineer Incharge. Nos. 20 34,264.00 6,85,280.00
an NS Cleaning of Rain Water Harvesting pits by machine complete in all respect upto the satisafaction of Engineer Incharge. Nos. 8 54,823.00 4,38,584.00
ao NS Providing and fixing in position pre-cast R.C.C. manhole cover of required shape and approved quality. sqm 500 1,081.00 5,40,500.00
Half brick masonry with non-modular fly ash bricks of class designation 10, conforming IS:12894, in super structure above plinth and upto floor V level. cement mortar 1:4 (1
cement : 4 coarse sand)
Supply, operation, maintenance of 6Hp Pneumatic Guniting Machine complete in all repect.Contractor is responsible for complete operation & maintenance (Servicing and repair)
aq NS of machine at his own cost during the entire period of maintenance and after completion of tender handover the same in healthy and operational condition. Contractor have to get No. 3 2,56,237.00 768711
the approval from NBCC EIC for the machine, model, specs before its purchase and in case of any dispute decision of Engineer-In-Charge shall be final and binding.
Supply, operation, maintenance of thermal imaging machine for water/moisture detection inside walls/floors (Make Bosch Model D-Tect 200 C Professional or equivalent) or as
per direction of EIC. Contractor is responsible for complete operation & maintenance (Servicing and repair) of machine at his own cost during the entire period of maintenance and
after completion of tender handover the same in healthy and operational condition. Contractor have to get the approval from NBCC EIC for the machine, model, specs before its
purchase and in case of any dispute decision of Engineer-In-Charge shall be final and binding.
Digitally signed by VARUN
Supply, operation, maintenance of Organic/Garden Waste Shredder with trolley and wheel, specifications of 3HP, 3 PHASE having minimum capacity of 150kg/hr, complete in all
respect. (Ref make Namibind and model no. OWS-1500 OR EQUIVALENT). Contractor is responsible for complete operation & maintenance (Servicing and repair) of shredder
machine at his own cost during the entire period of maintenance and after completion of tender, handover the same in healthy and operational condition. Contractor have to get the
approval from NBCC EIC for the machine, model, specs before its purchase and in case of any dispute decision of Engineer-In-Charge shall be final and binding.
Supply, operation, maintenance of electric driven hydraulic garbage auto tipper vehicle, complete in all respect (Reference make: Tata Ace Hopper/garbage Tipper Truck) or as
per direction of EIC. Contractor is responsible for complete operation & maintenance (Servicing and repair) of Vechile/machine at his own cost during the entire period of
maintenance and after completion of tender handover the same in healthy and operational condition. (Note: Contractor have to get the approval from NBCC EIC for the machine,
model, specs before its purchase and in case of any dispute decision of Engineer-In-Charge shall be final and binding).
Supply, operation, maintenance of Telescopic Hydraulic boomlift, capacity 227kg, platform height 80 feet, power source diesel, Smooth and stable operation with 360° continuous
rotation, Suitable for outdoor use complete in all respect. Contractor is responsible for complete operation & maintenance (Servicing and repair) of vehicle at his own cost during
au NS the entire period of maintenance and after completion of tender handover the same in healthy and operational condition. In case of breakdown the contractor has to restore/repair No. 1 44,84,148.00 4484148
the machine withn 72 hrs failing which NBCC will get it repair at the cost of contractor without any notice. The Contractor have to get the approval from NBCC EIC for the machine,
model, specs before its purchase and in case of any dispute decision of Engineer-In-Charge shall be final and binding.
Supply, operation, maintenance of Hydraulic Pump driven by the Vehicle Engine based De-Silting Grabbing machine having Grab bucket capacity of 20-50 ltrs or more, Hopper
capacity of 0.5 to 1 cubic meters or more,complete in all respect. Contractor is responsible for complete maintenance (Servicing and repair) of Electric mini 3 wheeler vehicle at his
own cost during the entire period of maintenance and after completion of tender handover the same in healthy and operational condition. Contractor have to get the approval from
NBCC EIC for the machine, model, specs before its purchase and in case of any dispute decision of Engineer-In-Charge shall be final and binding.
Supply and installation of closed cell nitrile rubber tubular insulaton (19 mm thick with aluminium 0.37 mm thick) cladding for insulation of water supply pipes at terraces of Per Top floor flat
residential flats of Type-6 qtrs. Terrace
Supply and installation of closed cell nitrile rubber tubular insulaton (19 mm thick with aluminium 0.37 mm thick) cladding for insulation of water supply pipes at terraces of Per Top floor flat
residential flats of Type-7 qtrs. Terrace
ay NS Supply & painting and finishing of THERMO COOL PAINT ON OVERHEAD TANKS, complete as required Sqm 2168.64 360.00 - 7,80,710.40
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including
hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded
or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike plate and shock absorbers as
specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
ayi 10.14.1.1 Profile B: Fixing with adjustable lugs with split end tail to each jamb mtr 450.00 584.58 2,63,059.84 -
Supply of Minimum 240 ltrs or sufficient capacity of suitable make such as Heavy duty plastic, manual lift, covered dustbins with wheels for waste collection
from each tower or as per direction of EIC. Contractor is responsible for complete Operation & maintenance (Servicing and repair) of the dustbins at his own
cost during the entire period of maintenance and after completion of tender handover the same in healthy and operational condition. (Ref make Nilkamal
Manual-Lift Garbage Waste Dustbin with Wheels (240 LTR, Green) or equivalent from other approved makes.)
SUB TOTAL OF Civil works for maintenance 79,97,575.59 2,51,10,297.66
13 Electrical Works
Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in
surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing
the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
b NS Supply & Installation of 450 mm Metallic exhaust fan including making good the damage, connection, testing, commissioning etc. as required. each 20 6851.00 1,37,020.00
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular
plate etc. as required.
Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal( Aluminum
alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit,safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value
DSR FOR BLDC fans (CM/M/W) minimum as below, 350 RPM (tolerance as per IS :374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with
2.2.3 regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation
resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply,earthing etc. complete as
req.1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum)
Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose
e 2.3.2 wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for each 5 2,773.00 13,865.00 -
mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with 8 way Double door
Supplying and fixing following way prewired vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose
f 2.3.3 wire box of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for each 5 2,871.00 14,355.00 -
mounting MCB's, terminal connectors for all incoming and outgoing circuits, duly prewired with 12 way Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with
g 2.4.1 tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without each 5 4,377.00 21,885.00 -
MCB/RCCB/Isolator) 4 way (4 + 12), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with
h 2.4.2 tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without each 5 5,299.00 26,495.00 -
MCB/RCCB/Isolator) 6 way (4 + 18), Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with
i 2.4.3 tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without each 5 6,337.00 31,685.00 -
MCB/RCCB/Isolator) 8 way (4 + 24), Double door
j 2.10.1 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature Single Pole each 5 285.00 1,425.00 -
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC
k 1.54.1 insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper each 200.00 914 1,82,800.00 -
conductor single core cable etc. as required. Group A
Digitally signed by VARUN
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC
l 1.54.2 insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper each 200.00 1083 2,16,600.00 -
conductor single core cable etc. as required. Group B
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/
recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as
required. 3 x 1.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as
required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as
required. 3 x 4 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as
required. 3 x 6 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as
required. 6 x 6 sq. mm
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.
as required. Telephone socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.
as required. TV antenna socket outlet
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc.
as required. Bell push
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the
same in case of recessed conduit as required. 25 mm
Re-filling of all types of fire extinguishers ( e.g. 4.5kg /9 kg CO2 Type ,6kg /9 kg ABC type, 9kg water co2 type etc) including transporation to & fro get to
be done as per DFS/ manufacturers recommondations .
Supply & fixing of 120 min. fire rated steel Fire door (Single or Double Leaf type) of 120 minutes fire rating duly tested and certified from reputed labs/test house .The
Shutter is fabricated with 2 nos. 1.2mm thick galvanized steel sheet with infill of fire rated properitory insulation filler both faces of sheet with lock seam joints at stile
edges and internal reinforcement at top, bottom and stile edges for strength for its stability and integrity of the fire door. The door frames are manufactured from
1.6mm thick galvanized steel sheet pressed form to single rebate profile of section 60x35mm / 60x50mm. The shutter is having a profile as Top Rail and Vertical Styles as
60x60mm and Bottom Rali as 110x60mm. provided with GI beading of suitable size made out of 2mm thick GI sheet. The door frames and door shutters are finished with
Powder Coating. Provisions for fixing all fixtures shall be built in on the doors prior to the supply.
af NS Supply & fixing of SS Ball Bearing Hinges of size 4 x 3 x 3 inch complet with SS Screws. set 36.00 133.00 4,788.00
ag NS Supply & fixing of Panic Bar single / double leaf panic exit devices. each 50.00 13671.00 6,83,550.00
ah NS Supply & fixing of Panic Trim with handle for Operation From The Other Side Of The Panic Bar. Nos. 50.00 4672.00 2,33,600.00
ai NS Supply & fixing of Concealed TOWER BOLT Nos. 33.00 279.00 9,207.00
aj NS Supply & fixing of Vision Glass with beading Nos. 50.00 4586.00 2,29,300.00
ak NS Supply & fixing of Door Closer having handling capacity of minimum 80 KG. Nos. 50.00 3965.00 1,98,250.00
Telephone wiring in Existing Conduits: Supplying and drawing following pair 0.61 sq mm FR PVC insulated annealed copper conductor, unarmored
telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular
socket outlet and 5/6 A modular switch, connections etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A
modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supply & Installation of high discharge sealed maintenance free battery of 12V 12AH for Lifts/UPS inculding deduction for unserviceable batterys (Rs.100)
complete as required.
Supply & Installation of high discharge sealed maintenance free battery of 12V 75AH for Solar pole light including deduction for unserviceable batterys
(Rs.1000) complete as required.
Supply & Installation of high discharge sealed maintenance free battery of 12V 180AH for HT Panel/DGs inculding deduction for unserviceable batterys
(Rs.2000) complete as required.
ar NS Supply & Installation of DC Power pack is used as a source of DC power in Power substations of 24V 7AH complete as required. each 6.0 8,134.00 - 48,804.00
as NS Providing and fixing of 3 ltr Electric Instant Geyser, complete in all respect. Each 10.00 3,799.00 37,990.00
Supply & Installation of Informatory signage comprising of ACP sheet sides Facia, angle iron frame, backlit star flex, sheet in MS tube frame having
at (i) NS monogram and printing fix on both faces including LED module and all fixing arrangement clamp etc. complete at different locations at site and as per sqm 60.68 9,194.00 5,57,932.84
direction of EIC.
Supply & Installation of Informatory signage comprising of Acrylic signage board, both side refelctive, sheet in MS tube frame having monogram and
printing fix on both faces and all fixing arrangement clamp etc. complete at different locations at site and as per direction of EIC.
au NS Supply, Installation, Testing & commissioning of Brass Air Release Valve of 25mm. Nos. 78.00 1,200.00 93,600.00
Digitally signed by VARUN
Supplying,installation,testing and commissioning of Passive Infrared(PIR) technology based occupancy sensor having high preformance, non regulating
av 15.1 programmable type, suitable for connected load upto 10Amp, for mounting height up to 2.8 mtr and for 5 m diameter coverage area along with necessary Each 118.00 4,896.00 5,77,728.00
fixing arrangements i/c programming at site etc. complete as required.
Providing fasteners for kitchen cabinets & fixing is in the scope of working agency. Fastening is done as a provision of providing support to kitchen cabinets
aw NS for safety purpose. fastners dia 10mm and 100 mm length. (For Type II & III, Type IV, Type V and Type VI & VII) Reference make: Hilti or other equivalent Each 960.00 137.00 - 1,31,520.00
from approved makes)
ax NS Supply, fixing & commissioning of Lift Phone with Speaker, 24V with base cover for lifts ( Make Beetel G-30 or equivalent from approved makes) Each 50.00 2,050.00 - 1,02,500.00
Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6
Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter
ay 39.17.1 should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and meter 8,000.00 60.00 4,80,000.00 -
Pulling Force: 11.5Kg etc. complete as required.
Supplying, installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular/round ducting complete with neoprene rubber
gaskets, elbows, splitter dampers, vanes, hangers,supports, bends, transitions, reducers, end caps,collars etc as required complete in all respect in
confirmation with IS : 655 and approved drawings and specifications of following sheet thickness complete as required.
Thickness 1.00 mm sheet
Water Level Indicator Unit: Supplying display unit of continuous wireless water level indicator with 7-segment LED display (56mm height) to indicate water
level of single/ multiple tanks (Maximum 6 Tanks) in percentage with 1 % resolution. It will also indicate Flow status and audio/ visual alarm for Full/Low/
Overflow condition. ( Only Receiver/ Display unit without transmitters. Water level data Transmitters unit will be charged separately) [Size in mm: 426(H)
x225(W)x95(D)] (Ref Model- Flexibell or equivalent )
Digital Sump Transmitter with 25ft Sensor Length: Supplying battery powered water level data transmitter with water level sensors to measure water level
with 1% resolution and flow/ overflow status and transmit the data wirelessly to controller cum receiver unit.
Supply & fixing of 12W, 240V, lumen efficacy >50lu/w, CCT 3000K/4000K/5000K, 600 mm (H), 100 mm dia LED decorative Bollard of aluminium di cast
body. (Ref make Divitrol, model: Rocca or equivalent other approved makes)
Supply of cleaner for stainless steel chrome, aluminium and metal surfaces having weightof 0.63 grams or as per direction of EIC. (Ref make & model: 3M
Stainless steel cleaner and polish or from other approved makes)
Supply & fixing Mobile signal Booster kit (Consisting of 1 booster + 2 panel antenna), Frequency boost (9GSM+DCS+3G+4G*(800+1800+2100MHZ)) or as
per direction of EIC.
be NS Supply,laying & fixing of Coaxial wire (consisting of wire connector) or as per direction of EIC. Meter 600.00 206.00 1,23,600.00
14 SH-IV: LIFT WORKS
A Comprehensive ARM of OF LIFTS/ELEVATORS, ETC. For 1st 12 months
Lift Category 1 ( EQ NO.
i Per Month Per Lift 384.00 8,375.69 32,16,263.97
Lift Category 2 (EQ NO.
ii Per Month Per Lift 480.00 8,268.86 39,69,055.09
iii Lift Category 3 (EQ NO. 10863945) Per Month Per Lift 12.00 7,987.96 95,855.53
Lift Category 4 (EQ NO.
Lift Category 5 (EQ NO.
Lift Category 6 (EQ NO.
vi Per Month Per Lift 468.00 13,807.82 64,62,058.47
vii Lift Category 7 (EQ NO.10895189, 10895192) Per Month Per Lift 24.00 11,513.11 2,76,314.60
viii Lift Category 8 (EQ NO. 10895194) Per Month Per Lift 12.00 12,264.82 1,47,177.88
B Comprehensive ARM of OF LIFTS/ELEVATORS, ETC. For 13th to 24th month
Lift Category 1 ( EQ NO.
i Per Month Per Lift 384.00 8,794.47 33,77,077.17
Digitally signed by VARUN
Lift Category 2 (EQ NO.
ii Per Month Per Lift 480.00 8,682.31 41,67,507.84
iii Lift Category 3 (EQ NO. 10863945) Per Month Per Lift 12.00 8,387.36 1,00,648.31
Lift Category 4 (EQ NO.
Lift Category 5 (EQ NO.
Lift Category 6 (EQ NO.
vi Per Month Per Lift 468.00 14,498.21 67,85,161.39
vii Lift Category 7 (EQ NO.10895189, 10895192) Per Month Per Lift 24.00 12,088.76 2,90,130.33
viii Lift Category 8 (EQ NO. 10895194) Per Month Per Lift 12.00 12,878.06 1,54,536.77
C Comprehensive ARM of OF LIFTS/ELEVATORS, ETC. For 25th to 36th month
Lift Category 1 ( EQ NO.
i Per Month Per Lift 384.00 9,234.20 35,45,931.03
Lift Category 2 (EQ NO.
ii Per Month Per Lift 480.00 9,116.42 43,75,883.23
iii Lift Category 3 (EQ NO. 10863945) Per Month Per Lift 12.00 8,806.73 1,05,680.72
Lift Category 4 (EQ NO.
Lift Category 5 (EQ NO.
Lift Category 6 (EQ NO.
vi Per Month Per Lift 468.00 15,223.12 71,24,419.46
vii Lift Category 7 (EQ NO.10895189, 10895192) Per Month Per Lift 24.00 12,693.20 3,04,636.85
viii Lift Category 8 (EQ NO. 10895194) Per Month Per Lift 12.00 13,521.97 1,62,263.61
SUB TOTAL OF ARM OF Lifts Total - 9,32,49,005.02
15 Maintenance of CCC
CAMC including running, operation, service & repair of Control command center and all supporting & associated equipments.
Main Control & Command Centre: 1 no. Video Wall, No. LIU, Servers, Water SCADA System
ACTIVE & PASSIVE Devices: VMS Server and Client for Outer Cameras:, Power Edge R7 30 Storage Server-12 Nos., VMS Server Proliant DL360 Gen9-12 nos. VMS Software-
CISCO Devices: CISCO Internet Router-2 nos.Firewall-2 nos., Spine switches-2 nos. Leaf Switches- 2 nos. San Switches-2 nos. UCS Server- 5 nos.Prime Infra (UCS C460)-2
nos. Fire power Management -1 no. Threat Grid Appliances- 1 no. Web Security Appliances-1 no. Call Manager Server- 2 nos. Voice gateway – 2 nos. Voice Routers- 2 nos., Net
app storage-1 no.
LIU’s, Huawei Access NE Management Function Server-1 no. Juniper switches for CCTV- 34 nos. Cisco/Dlink switches for CCTV- 325 nos. NVR-291 nos. Delta Video Wall 4*2
with Server-1 no. Motorized wall-189 nos. Sensor 6 mtr-189 nos. Sensor 10 mtr-9 nos. Fully Wired Enclosure with PLC-103 nos. Fully Wired RTU Panel with PLC-9 nos.
Precision Air conditioning – 6 nos. 80KVA UPS with battery bank with redundancy-2 nos. Computer set-10 nos. Access control- 2 nos. Water leak detection system- 1 no. Split AC-8
nos., Rodent Repellant System-1 no., Command Centre setup- 1 no., TV’s installed in Local Control rooms – 106 nos., Water SCADA system,ONT - 4833 nos., Routers – 1647
nos., OFC network, CCTV cameras – 4534 nos., 1 KVA UPS – 34 nos. C459, IP/EPBAX system, etc.
i CAMC rates for CCC for 1st month to 12th month Per Month 12 12,51,390.00 1,50,16,680.00
ii CAMC rates for CCC for 13th month to 24th month Per Month 12 12,88,931.70 1,54,67,180.40
iii CAMC rates for CCC for 25th month to 36th month Per Month 12 13,27,599.65 1,59,31,195.81
Sub Total CAMC of CCC 4,64,15,056.21
16 AMC of REPAIRING AND PAINTING OF MURALS ART WORK in all respect. Sqft 5559.60 295.00 - 16,40,082.00
Digitally signed by VARUN
17 AMC of DG SETS
a 1500 KVA DG SETS for 1st month to 12th month Per Month 120.00 7,821.19 9,38,542.50
b 1010 KVA DG SETS for 1st month to 12th month Per Month 36.00 7,821.19 2,81,562.75
c 750 KVA DG SETS for 1st month to 12th month Per Month 24.00 7,821.19 1,87,708.50
d 1500 KVA DG SETS for 13th month to 24th month Per Month 120.00 8,134.04 9,76,084.20
e 1010 KVA DG SETS for 13th month to 24th month Per Month 36.00 8,134.04 2,92,825.26
f 750 KVA DG SETS for 13th month to 24th month Per Month 24.00 8,134.04 1,95,216.84
g 1500 KVA DG SETS for 25th month to 36th month Per Month 120.00 8,459.40 10,15,127.57
h 1010 KVA DG SETS for 25th month to 36th month Per Month 36.00 8,459.40 3,04,538.27
i 750 KVA DG SETS for 25th month to 36th month Per Month 24.00 8,459.40 2,03,025.51
j B-Check for 1500 KVA DG sets Half yearly 60.00 1,77,000.00 1,06,20,000.00
k B-Check for 1010 KVA DG sets Half yearly 18.00 1,77,000.00 31,86,000.00
l B-Check for 750 KVA DG sets Half yearly 6.00 1,59,300.00 9,55,800.00
m Coolant for 1500 KVA DG sets In every 3 years 10.00 1,38,146.34 13,81,463.41
n Coolant for 1010 KVA DG sets In every 3 years 13.00 86,341.46 11,22,439.02
o Coolant for 750 KVA DG sets In every 3 years 2.00 99,292.68 1,98,585.37
Sub Total of DG sets AMC 2,18,58,919.21
18 CAMC for Boom Barrier
Comprehensive AMC charges for Boom Barrier 07 Nos. Long Range Reader 07 nos. and Controller 06 nos. with photocell and other accessories installed at
NBCC Kidwai Nagar for 1st month to 12th month.
Comprehensive AMC charges for Boom Barrier 08 Nos. Long Range Reader 08 nos. and Controller 08 nos., Software 01 no. including all other accessories
installed at NBCC Kidwai Nagar for 1st month to 12th month.
Comprehensive AMC charges for Boom Barrier 07 Nos. Long Range Reader 04 nos. and Controller 04 nos. Software 01 no. including all other accessories
installed at NBCC Kidwai Nagar for 1st month to 12th month.
Comprehensive AMC charges for Boom Barrier 07 Nos. Long Range Reader 07 nos. and Controller 06 nos. with photocell and other accessories installed at
NBCC Kidwai Nagar for 13th month to 24th month.
Comprehensive AMC charges for Boom Barrier 08 Nos. Long Range Reader 08 nos. and Controller 08 nos., Software 01 no. including all other accessories
installed at NBCC Kidwai Nagar for 13th month to 24th month.
Comprehensive AMC charges for Boom Barrier 07 Nos. Long Range Reader 04 nos. and Controller 04 nos. Software 01 no. including all other accessories
installed at NBCC Kidwai Nagar for 13th month to 24th month.
Comprehensive AMC charges for Boom Barrier 07 Nos. Long Range Reader 07 nos. and Controller 06 nos. with photocell and other accessories installed at
NBCC Kidwai Nagar for 25th month to 36th month
Comprehensive AMC charges for Boom Barrier 08 Nos. Long Range Reader 08 nos. and Controller 08 nos., Software 01 no. including all other accessories
installed at NBCC Kidwai Nagar for 25th month to 36th month.
Comprehensive AMC charges for Boom Barrier 07 Nos. Long Range Reader 04 nos. and Controller 04 nos. Software 01 no. including all other accessories
installed at NBCC Kidwai Nagar for 25th month to 36th month.
Sub Total CAMC for Boom Barrier 79,56,747.43
19 AMC for GEYSERS
a AMC charges per geyser of all capacities including visit charges, repair and repalcement of defective parts, any other issue like leakage of heating issues etc.
i AMC rates for Geysers for 1st month to 12th month Each 600 1,188.82 7,13,292.30
ii AMC rates for Geysers for 13th month to 24th month Each 600 1,236.37 7,41,823.99
iii AMC rates for Geysers for 25th month to 36th month Each 600 1,285.83 7,71,496.95
Sub Total AMC of Geysers 22,26,613.24
20 AMC for Chimney
AMC charges per chimney including chimney service and repairing with material, one time deep cleaning and two times normal service chimney, motor
chimney blower, main PCB control & oil collector etc.
i AMC rates for Chimney for 1st month to 12th month Each 150 4,317.30 6,47,594.33
ii AMC rates for Chimney for 13th month to 24th month Each 150 4,489.99 6,73,498.10
iii AMC rates for Chimney for 25th month to 36th month Each 150 4,669.59 7,00,438.02
Digitally signed by VARUN
Sub Total AMC of Chimney 20,21,530.44
21 AMC of Swachh Aawas App and Web application including server charges
a AMC charges for operation, upgradation & maintenance of Swachh Aawas App and Web application in all respect.
i AMC rates for Swachh Aawas App and Web application for 1st month to 12th month Each 12 32,723.85 3,92,686.18
ii AMC rates for Swachh Aawas App and Web application for 13th month to 24th month Each 12 33,705.56 4,04,466.77
iii AMC rates for Swachh Aawas App and Web application for 25th month to 36th month Each 12 34,716.73 4,16,600.77
Sub Total AMC of Swachh Aawas App and Web application 12,13,753.72
22 AMC of Complaint Management App and Web application including server charges
a AMC charges for operation, upgradation & maintenance of Complaint Management App and Web application in all respect.
i AMC rates for Complaint Management App and Web application for 1st month to 12th month Each 12 25,027.80 3,00,333.60
ii AMC rates for Complaint Management App and Web application for 13th month to 24th month Each 12 25,778.63 3,09,343.61
iii AMC rates for Complaint Management App and Web application for 25th month to 36th month Each 12 26,551.99 3,18,623.92
Sub Total AMC of Complaint Management App and Web application including server charges 9,28,301.12
23.0 Watch & Ward
Providing services of Watch & Ward at required locations round the clock with all requisite accessories etc complete in all respect or as per direction of
Engineer Incharge.
24 Special Repair
Supplying Installation Testing and Commissioning of 2 MP IP IR Dome Camera having following specifications, type of lens and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio:>50 dB, Camera should display Camera title, Date & Time in live & recorded video
2)Image Sensor: 1/2.8" or better progressive ScanCMOS to get color image even at nightcondition(Minimum Illumination: 0.006 Lux@ F1.4,
AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50
meter or better and 30 meter for colour view in night, Imaging: 1/3s to 1/30000s electronic shutter support, Auto Gain Control, White Balance- Auto, Back Light Compensation,Multi zone Privacy
Masking, HLC, Digital Watermarking.
3) Compression (Minimum):-Video:- H.265 or better,H.264H, H.264, Audio:- G.711U/A, G.711Mu, G.726,AAC, G.723
4) Wide Dynamic Range:- WDR (120db or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming,configurable (Main stream: 2MP (1920×1080)@25/30 fps,Sub streams minimum:
7) Image Setting: Rotate Mode, saturation, brightness,contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection
8) Cyber Security: AES 256-bit Encryption,Configuration encryption, trusted execution, Digest,security logs, account lockout, syslog, video encryption, IP/MAC filtering, HTTPS, trusted upgrade,trusted
9) Onboard Storage: Camera should support built-in Micro SD/SDHC/SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.
a DSR 40.1 10) Recording Management: Format SD, overwrite,storage management, video to NAS device
11) Alarm Trigger : Motion/tampering detection; audio detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection
12)Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP,NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE,NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS,
13) System Capability: ONVIF, Camera shall support open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power
17) Power Requirement: 12VDC/24 VAC/PoE (802.3af)/ePoE
18) Housing/ Enclosure:- IP67 weather proof, IK10,Metallic body
19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
i 40.1.1 2MP (@ 25/30fps@1080P (1920×1080)) IP IR Dome Camera with 2.8/ 3.6mm fixed lens Each 245.00 8,048.00 19,71,760.00
Digitally signed by VARUN
Supplying Installation Testing and Commissioning of 4MP IP IR Outdoor Bullet Camera having following specifications and features etc :-
1) Signal System: PAL/NTSC, Signal to Noise Ratio: >50 dB,Camera should display Camera title, Date & Time in live & recorded video
2)Image Sensor: 1/2.8" or better progressive Scan CMOS get color image even at night condition(Minimum Illumination: 0.006 Lux@ F1.4,
AGC ON, 0 lux with IR or better) True Day & Night High Performance Mechanical IR cut filter with auto switch, Integrated IR Source (Auto, Manual)- Inbuilt IR LED's with effective distance upto 50
meter or better and 30 meter for colour view in night, Imaging: 1/3s to
1/30000s electronic shutter support, Auto Gain Control, White Balance- Auto, Back Light Compensation, Multi zone Privacy Masking, HLC, Digital Watermarking.
3) Compression (Minimum): Video:- H.265 or better, Audio:- G.711U/A, G.711Mu, G.726, AAC, G.723
4) Wide Dynamic Range:- WDR (120dB or more)
5) Digital Noise Reduction:- DNR (3D) On/Off
6) Video Streaming & Frame Rates :- Triple streaming, configurable Main stream: 4MP (2560×1440)25/30fps Sub streams minimum: 720P@25/30 fps
7) Image Setting: Rotate Mode, saturation, brightness, contrast, sharpness adjustable through client software or web browser, Edge Analytics: Tripwire, Intrusion,Motion Detection
8) Cyber Security: AES 256-bit Encryption, Configuration encryption, trusted execution, Digest, security logs, account lockout, video encryption, IP/MAC filtering, HTTPS, trusted upgrade
9) Onboard Storage: Camera should support built-in Micro SD/ SDHC/ SDXC Card slot upto 512 GB. It should be supplied with minimum 128GB memory Card.
b DSR 40.4 10) Recording Management: Format SD, overwrite, storage management, video to NAS device,
11) Alarm Trigger : Motion/tampering detection; network disconnection detection; IP conflict detection; memory card state detection; memory space detection
12) Network Protocol: SFTP, IPv6, IPv4, DNS,RTCP, NTP, RTP, HTTP, HTTPS, SNMP TCP/IP, PPPoE, NFS, UDP, ICMP, SSL, DHCP, SMTP, RTSPS, unicast,
13) System Capability: ONVIF, Camera shall support open source VMS
14) Ethernet: 1 RJ 45 10/100 Ethernet port
15) Audio : It should support 1 x Built-In Mic and 1/1 Alarm In/ Out for External Mic. and Speakers as per site requirement.
16) Power Input: The camera should support simultaneous dual power input—12 VDC (via power adapter) and PoE (802.3af)—to ensure continuous operation in the event of a failure in one power
17) Power Requirement: 12VDC/24 VDC/PoE (802.3af)/ePoE
18) Housing/ Enclosure:- IP67 weather proof, IK10, Metallic body
19) Operating Condition:- Ambient Temperature:- (-)05°C to 50°C, humidity 95% (max) (non-condensing)
20) IR life: 40000 hours or higher
21) Video Bit rate: 32 KBPS - 8 MBPS or better
22) Standards: BIS with ER, STQC Certified, CE, FCC and RoHS
i 40.4.2 4MP @ 25/30fps@1440P (2560x1440) Outdoor Bullet Camera with 2.7 to 4 mm ~12 to 13.5mm or better Varifocal Motorized lens. Each 10.00 23,754.00 2,37,540.00
Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as
mentioned below :
1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses for number of channels of NVR to record per NVR and to provide a live view, storage and simultaneously Multi-
playback of all IP, IR camera or more and must be ONVIF with minimum support of 256Mbps incoming Bandwidth.
2) NVR should support H.265 or better, H.264, MJPEG, MPEG4 support
3) Must support 1 channel Input, 1 channel Output, RCA for Two-way Talk
4) Intelligent auto power on when power resumes after power outage.
5) Storage: It should support minimum 2 SATA Slots with 20TB capacity/ Slot.
6) Connectivity Interface : 1 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232
7) Backup Interface : Its should have 2 Nosx USB port (1x USB3.0, 1xUSB2.0)
8) Video Output Ports: 1x HDMI and 1 VGA
9) Alarm Ports: It should have 4/1 Ch In/ Out ports to connect various type of external sensors and output devices like hooter/ Siren etc.
10) Email & SMS Altert options: Option for SMS/ Email Alerts to minimum 5 designated mobile number for power failure, HDD failure, vandalism, tempring, network disconnection and panic
11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing.
12) Protocols: HTTP, HTTPS, TCP/IP, IPv4, UDP, NTP, DHCP, DNS, SMTP, UPnP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM
Cloud for remote monitoring without any public IP need.
13) Standards: CE, FCC, RoHS and BIS Certified
14) Power Supply : Should support 12VDC, 4Amp or AC100-240V, 50/60Hz Power supply.
15) Operating Condition : Ambient Temperature (-5°C to 50°C), humidity 90% (max) (non-condensing)
16) The VMS, NVR application shall support all the features & functionalities of the offered cameras.
17) VMS should consist of Base license and Channel Licenses. VMS should be provided with camera Licenses , with no dependency of VMS licenses by binding with the MAC address of the cameras to
achieve the functionality.
18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring and playback of cameras/NVR footage.
19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet.
21) Must support recording resolution upto 32MP
22) Must support Continuous, Alarm, Motion, Instant, Panic Recording Mode
23) When alarm recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page
24) The Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient
address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of
alarm and a list of camera that is configured to record upon alarm
25) It should support Network Support: HTTP, TCP/IP, SMTP, DHCP, DNS, DDNS, FTP, NTP, UPnP, Multi IP Setting. Convert multiple recording files to one avi/MP4 file.
26) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,
Violence Detection.
27) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion
and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan
28) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.
29) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection
30) Face Recognition Database Capacity: It should support total Blacklist and Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec.
31) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age, gender and umbrella.
32) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc vehicle attributes.
33) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter protection (intrusion
tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception
34) Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email.
35) General AI Based Search: Search Pictures by channel, time, event type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection,
Violence Detection.
36) Smart playback function: Should support smart search for the selected area in the video and smart playback to improve the playback efficiency
37) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera analytics
i 40.10.1 08 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9, 2nd screen:1/4/8/9 Each 10.00 10,078.00 1,00,780.00 -
ii 40.10.2 16 Channel Network Video Recorder (NVR) having display split:- Main screen: 1/4/8/9/16, 2nd screen: 1/4/8/9/16 Each 20.00 12,799.00 2,55,980.00 -
Digitally signed by VARUN
Supplying Installation Testing and Commissioning of following Channel Network Video Recorder (NVR) with camera licenses to record for all channels having specifications and features etc as mentioned
1) Network Video Recorder Embedded/ Installed OS (Linux) along with Camera Licenses to record per NVR and to provide a live view, storage and simultaneously Multi-channel playback of all IP
camera or more and must be ONVIF with minimum support of 384 Mbps incoming Bandwidth. 2) NVR should support video compressions : H.265 or better, H.264, MJPEG. 3) Must support 1 channel
RCA Input, 2 channel RCA Output for Two-way Talk with G.711U/A, G.711u, PCM, G726 audio compressions. 4) Intelligent auto power on when power resumes after power outage. 5) Storage: It should
support minimum 8 SATA Slots with 20TB capacity/ Slot and RAID support of RAID 0/1/5/6/10. 6) Connectivity Interface : 2 Nos. x 10/100/1000 Mbps Ethernet Ports, 1x RS485, 1x RS232, 1x eSATA
Port 7) Backup Interface : Its should have 4 Nosx USB port (2x USB3.0, 2xUSB2.0) 8) Video Output Ports: 2x HDMI and 2 VGA. 9) Alarm Ports: It should have 16/8 Ch In/ Out ports to connect
various type of external sensors and output devices like hooter/ Siren etc. 10) Email & SMS Altert options: Option for SMS/Email Alerts to minimum 5 designated mobile number for power failure, HDD
failure, vandalism, tempring, network disconnection and panic 11) Web & Mobile Application: Web, Mobile app ( For iPhone, iPad, Android Phone) for alerts and viewing. 12) Protocols: HTTP, HTTPS,
TCP/IP, IPv4/IPv6, UDP, DHCP, DNS, SMTP, UPnP, IP Filter, PPPoE, FTP, DDNS, Alarm Server, IP Search, Multicast, Auto Registration, ONVIF (Profile T, Profile S, Profile G), CGI, SDK and OEM Cloud for
remote monitoring without any public IP need. 13) Standards: CE, FCC, RoHS, BIS Certified. 14) Power Supply : Should support AC100-240V, 50/60Hz Power supply. 15) Operating Condition : -5°C to
50°C, humidity 90% (max) (non-condensing). 16) The VMS application shall support all the features & functionalities of the offered cameras. 17) VMS should consist Licenses for all channels to record
Cameras with General, motion detection, intelligent, alarm and POS recording modes. VMS should be provided with Camera Licenses, with no dependency of VMS licenses by binding with the MAC
address of the cameras to achieve the functionality. 18) The NVR OEM shall be responsible for providing a mobile application compatible with both Android and iOS devices, enabling remote monitoring
and playback of cameras/NVR footage. 19) The OEM must provide its own DDNS server hosted in India, eliminating the need for a public IP address for remote monitoring over the Internet. 20) Must
d 40.11 support Continuous, Alarm, Motion, Instant, Panic Recording Mode. 21) It should support Resolution: 32MP; 24MP; 16MP; 12MP; 8MP; 5MP; 4MP; 1080p; 720p; D1; CIF; QCIF. 22) When alarm
recording is enabled and an event occurs, you can click the alarm icon on monitoring page to view the alert details. The snapshot function is supported on monitoring and playback page. 23) The
Network Video Recorder (NVR) shall be configured to send email whenever a system message is created or an alarm event occurs. The email server shall be a valid SMTP server. Each recipient email
address shall be configured to receive any combination of critical, warning, or informational messages or alarm notifications. When an alarm occurs, the email message includes the NVR name, time of
alarm and a list of camera that is configured to record upon alarm. 24) It should have Web and GUI interface. .25) Built-In Artificial Intelligence: NVR should have built-in AI :- - 2 Channel face
detection and recognition, - Minimum 4 Channel perimeter protection, - Minimum 8 Channel Smart Motion Detection. 26) Face Recognition Database Capacity: It should support total Blacklist and
Whitelist capacity of Minimum 20,000 Faces or more with Face Detection speed of 12 face images/sec and facility to add Name, gender, birthday, address, credential type, credential No., countries &
regions and state to each face image. 27) Face & Human Attributes Search: Search Pictures/ Video by Gender, age group, glasses, expressions, face mask, beard, Top color, top type, hat, bag, age,
gender and umbrella. 28) ANPR Capability: It should support ANPR Camera with License plate, plate color, vehicle body, vehicle model, vehicle logo, calling, seatbelt, vehicle registration location etc
vehicle attributes. 29) Alarm Notifications based on: Motion detection, video tampering, video loss, scene changing, PIR alarm, Camera external alarm, Face detection, face recognition, perimeter
protection (intrusion and tripwire), ANPR, people counting, stereo analysis, crowd distribution, heat map, Disk Full, Storage Error, IP Conflict and abnormal behavior of fan, cybersecurity exception 30)
Alarm Notification should be linked with Recording, snapshots, Camera external alarm output, buzzer, logs, presets and email. 31) General AI Based Search: Search Pictures by channel, time, event
type, target classification (Fall Detection, People Approach Detection, People No. Exception Detection, People Staying Detection, Violence Detection. 32) Smart playback function: Should support smart
search for the selected area in the video and smart playback to improve the playback efficiency . 33) VCA (Video Content Analytic): Should support multiple video contented analytics based on camera
analytics. 34) Analytics by NVR: Perimeter protection and face recognation.
i 40.11.1 32 Channel Network Video Recorder (NVR) having display split :- Main screen: 1/4/8/9/16/25/32(36), 2nd screen: 1/4/8/9/16 Each 5.00 64,784.00 3,23,920.00
Supplying, Installation, Testing and Commissioning following capacity Surveillance grade Hard Disk with upto 256MB/s Transfer Rate, 256 MB Cache, 7200
RPM Disk Speed, 3.5 inch form factor, SATA Interface, BSMI, ICES-003/NNB-003, CE, FCC, KC, Maghreb, RCM, UKCA, VCCI, CB-Scheme, TUV, UL
Certifications.
4TB (Terabytes)
Online UPS - Input supply: Single Phase, Output Supply: Single Phase. Supplying, installation, Testing & Commissioning of following capacity at full load
(Unity Power Factor) ON LINE Uninterrupted Power Supply (UPS) system suitable for Single Phase input,Single Phase output AC Supply. The UPS shall
include a Rectifier, inverter, battery bank suitable for 30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per
Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass switch along with provision for manual bypass, suitable
isolation transformer for additional protection against neutral faults etc. The UPS systems shall be Microprocessor based Digital Control, using Insulated
Gate BipolarTransistor (IGBT)'s both for the rectifier & inverter with PWM (Pulse Width Modulation) Technology. The quality of design, manufacturing and
inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency of the UPS systems shall be >95%
at 100% non-linear loads. Current total harmonic distortion(ITHD)/ total demand distortion (TDD) on the input grid shall be < 5% at 100 %load. (The
required LC filters shall be included in UPS cost), extreme power factor kit to be include to limit the input pf to 0.99 and output power factor shall be unity
f NS (i.e. kw rating of the UPS shall be kva rating x 1 ) however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be
suitable for incoming supply AC single phase160-270V 50 Hz and delivering output AC supply true sine wave single phase 220/230/240 Volt, 50 Hz +/-
0.2Hz, Overload capacity of 120% for 10 mins and 150% for 1 minute. Operating temperature 0 to 40 0C, Relative humidity 0-95% non condensing, noise
level less than 60db at 1 meter distance, Protection for Under voltage, over voltage, abnormal output voltage, battery over charging, output over current,
short circuit, battery deep discharge , 10 KV surge. Display for watt/VA,Amp and Voltage power parameters etc. UPS shall comply with low voltage
electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency Independent (VFI) type UPS
(as per standard IEC 62040-1, 2 & 3) . The UPS should be with IGBT Based Inverter Technology, Communication RS232/ RS485/ SNMP port open protocol
for BMS integration as per approved by Engineering in charge. Required battery racks, DC breaker of suitable rating and interconnecting copper conductor
cable of suitable size and connectors and all required accessories are inclusive in the cost. The UPS should have QR code which should contain drawing,
test report OEM manual, Geo- Tag of manufacturing location etc
Online UPS- Input supply: Three Phase, Output supply: Three Phase. Supplying, installation, Testing & Commissioning of following capacity at full load (Unity Power Factor) at operating temperature 0
to 40 0C, Relative humidity 0 to 95%, Online double conversion true sine wave Uninterrupted hot swapable (allow for the replacement or addition of battery modules without shutting down the entire
system) modular Power Supply (UPS) system with N+1 modules (N denotes total number of modules required for rated capacity). The UPS shall include a Rectifier, inverter, battery bank suitable for
30 minutes back up (Battery VAH capacity shall not be less than 1600 VAH per KVA of UPS rating per Hour backup time) on full load (Battery shall be VRLA, SMF in ABS Container) and Static Bypass
switch along with provision for manual bypass, suitable isolation transformer for additional protection against neutral faults etc. UPS shall have inbuilt phase sequence correction. The UPS systems
offered are to be of the latest technology with Digital Control Microprocessor based for reliable operation using Insulated Gate Bipolar Transistor (IGBT)'s both for the rectifier & inverter (3 Level)
with PWM (Pulse Width Modulation). The quality of design, manufacturing and inspection process should confirm to the relevant Inter-national standards such as IEC/EN/VDE. The operating efficiency
of the UPS systems shall be >96% while operating on battery mode and delivering quality power to the 100% non-linear loads. Current total harmonic effect(ITHD) on the input grid shall be <5% at
50 %load. (The required LC ( inductor (L) and a capacitor (C)) filters shall be included in UPS cost), extreme power factor kit to be included to limit the input power factor (PF) to 0.99 and output
power factor shall be unity (i.e. kw rating of the UPS shall be kva rating x 1 ), however UPS shall be suitable to take load at 0.7 laging to 0.7 leading power factor loads. UPS shall be suitable for
incoming supply AC : 3Phase 400V +/-20%, 50 Hz +/-5 Hz, AC Output voltage: 3Phase 415 Volt, 50 Hz +/- 0.2Hz, Overload capacity of 120% for 10 mins, Sine wave output. Non condensing, noise
g level less than 60db at 1 meter distance, protections: Input Under voltage over voltage, abnormal out voltage, battery over charging, output over current, short circuit protection, battery deep
discharge protection, 10KV surge. UPS must comply with low voltage electromagnetic compatibility (EMC) achieved as per EN 6204, EN6204 Part I and Part 2, it shall be a Voltage and Frequency
Independent (VFI)-type UPS. . Communication RS232/RS485/SNMP port open protocol for BMS integration, all hardware & software for iOT Communication as per approved by Engineering in charge.
Required battery racks and interconnecting copper conductor cables of suitable size and connectors and all required accessories are inclusive of the cost). This system must providea means for logging
and alarming of all monitored points plus email notification. Forced air-cooling with integral inbuilt fans with redundancy (if one fan fail UPS should be able to handle at least 80% of the load, Noise
Level 65 DB at 1 meter distance. The system shall be in compliance IEC 62040- 1,2 & 3, IS: 16242 and CPWD Specification. Display Panel (minimum) (In-build 5 inch or more LC Display / LED) to
display : a) Input: Voltage, current, Frequency. b) Bypass: Voltage, Frequency. c) Output: Voltage, frequency, Current. d) Battery: Voltage, Capacity. e) Load: KVA, KW, Percentage. f) Temperature:
STS, Inverter, PFC. g) Event Logging & Statistical Data (On LCD/LED): UPS should capture and display up to 3000 events like: Over temperature / DC Bus Fail / Fan Fail / Fuse Fail / Overload / Short-
circuit / Device Fail / Inverter Fail / Rectifier Fail / Bypass Fail, etc. h) Statistical Data: No. of power failures / Transfers to Bypass / Total Running time, etc. i) Mains Mode of Operation /Battery Mode
of Operation / Bypass feeding the load / UPS Fault /Battery charging and discharging, overload, battery voltage and battery capacity. j) Audible Alarms : Mains Failure, Battery Low Alarm, UPS
Overload, Fault, Shutdown, Input Over, Under Voltage, Output Over, Under Voltage, Battery Over, Under Voltage, Over Load and short circuit, Over Temperature. The UPS should have QR code which
should contain drawing, test report OEM manual, Geo- Tag of manufacturing location etc.
(i) 26.2.2 20KVA (Each Power module shall be < 10 KVA) each 6.0 341772 20,50,632.00
Digitally signed by VARUN
LED Down lighter (SMD Type) (System lumen Unit Rate efficacy ≥ 105 < 120 lm/Watt ) Supplying, Installation, Testing & Commissioning of LED Recessed/
surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA andprismatic diffuser and construction as per IS :
10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -50C
to 400C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare
Rating) < 19, Flicker free (flicker should be below 5%), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of
initial Lumen maintained till life ends, CCT 3000°K /4000°K / 5700°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Colour Matching)
<3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards. Manufactures
Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR,
PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and
<120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as
approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall
not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim.
LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following
body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P.
F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of
minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K /
4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than
I 8.6 the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.
in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required
with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED
fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat
sink of aluminium housing such that LED junction temperature shall not rise
above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).Supplying, Installation, Testing & Commissioning of LED surface mounted Batten light of
following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage
AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV
with Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical
circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K
(As per ANSI Bin), SDCM(Standard Deviation.
Providing and laying APP (Atactic Polypropylene Polymer) modified prefabricated five layer, 3 mm thick water proofing membrane, black finished reinforced
with glass fibre matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufactured of density at
25°C, 0.87 - 0.89 kg/litre and viscocity 70 - 160 cps. Over the primer coat the layer of membrane shall be laid using butane torch and sealing all joints etc.,
k 14.90.1 and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under : Joint strength in longitudinal and sqm 50.00 533.40 26,669.88
transverse direction at 23°C as 350/300 N/5 cm. Tear strength in longitudinal and transverse direction as 60/80N. Softening point of membrane not less
than 150°C. Cold flexibility shall be upto -2°C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the
authorised applicator of the manufacturer of membrane :
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement
compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This
layer will be allowed to air cure for 4 hours.
(b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure
for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes
and masonry with polymer mixed slurry.
Providing & Executing injection grouting for water proofing of raft,walls, slabs etc by grouting 15 mm dia 6 inch long GI nipple and injecting cement slurry
mixed with water proffing compound @1 kg/50kg of Cement by suitable pressure pump complete as per direction of EIC
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 600x600 mm
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with
grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.
Size of Tile 800x800 mm
Digitally signed by VARUN
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and
conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand)
jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the
p 11.41A.3.1 zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber sqm 500 1453.80503 7,26,902.52
mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all
colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed
with pigment of matching shade complete.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab,
r 11.26.1 including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : sqm 50 1933.5602 96678.01
Providing and fixing dry cladding upto 10 metre heights with 30mm thick gang saw cut stone with machine cut edges of uniform colour and size upto
1mx1m, fixed to structural steel frame work and/ or with the help of cramps, pins etc. and sealing the joints with approved weather sealant as per
Architectural drawing and direction of Engineer-in-charge. (The steel frame work, stainless steel cramps and pins etc. shall be paid for separately).
Red sand stone - 30mm thick gang saw cut stone
Providing & fixing of all new layers of badminton/volleball/basket ball court flooring in all respect. (Works also includes the Chipping & removing of old layer
of exisiting court for this no extra cost will be paid).
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of
approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with
wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge.
25 mm average thickness
Cleaning of reinforcement from rust from the reinforcing bars to give it a total rust free steel surface by using alkaline chemical rust remover of
v 26.29 approved make with paint brush and removing loose particles after 24 hours of its application with wire brush and thoroughly washing with water and
allowing it to dry, all complete as per direction of Engineer-In-Charge.
v (i) 26.29.1 Bars upto 12 mm diameter metre 700.00 8.2 5731.46
v (ii) 26.29.2 Bars above 12 mm diameter metre 700.00 16.3 11428.18
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer In-charge
complete in all respect.
w (i) 26.31.2 Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make Sqm 2500.00 283.0 707623.98
Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with
polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge.
x 26.32 Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this
item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal
instrument and/or the 75 mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).
x (i) 26.32.2 25 mm average thickness in 2 layers. Sqm 2500.00 582.9 1457303.45
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to
centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the
scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after. The
y 14.72 scaffolding system shall be stiffened with bracings,runners, connection with the building etc wherever required for inspection of work at required locations Sqm 6000.00 335.7 2014197.57
with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding
shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding.
Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
z 13.45 Finishing walls with textured exterior paint of required shade :
z (i) 13.45.1 New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @ 2.20kg/10 sqm Sqm 2500.00 221.9 554785.14
Providing and laying in position free flow high strength non shrink micro-concrete M-40 using single component cement micro concrete added with 6 mm
down size aggregate in the ratio of 1-part micro concrete with 0.3 part of aggregate by weight. Water cement ratio shall be maintained properly as per
manufacturers specifications to achieve dense soild mass prepared micro concrete shall be poured properly as per the prefixed holding boards slurry tight
form work properly aligned to required size and shape and well-oiled air bubbles if any shall be removed by tapping the boards removing the boards after
24 hours and curing the micro concrete thoroughly for 14 days cost inclusive of curing etc.complete all as directed at site by Engineer in charge (in small
patches at different location)
ab MOTOR & PUMP REPAIRING ITEMS
i S.NO. 7.5 H.P Motor Repairing Lower Vertical
a. Motor Rewinding Nos. 2 5,500.00 11,000.00
c. Motor Opening Fitting and Alignment Charges Nos. 2 2,000.00 4,000.00
ii 12.5 H.P Motor
a. Motor Rewinding Nos. 2 7,500.00 15,000.00
c. Motor Opening Fitting and Alignment Charges Nos. 2 3,000.00 6,000.00
iii 15 H.P Motor Lowara
a. Motor Rewinding Nos. 2 8,000.00 16,000.00
d. Motor Opening Fitting and Alignment Charges Nos. 2 3,000.00 6,000.00
iv 20 H.P Motor (RKB-50/15)
a. Motor Rewinding Nos. 5 12,188.00 60,940.00
c. Motor Opening Fitting and Alignment Charges Nos. 5 4,500.00 22,500.00
v 20 H.P High Pressure Pump Grandfoss Motor
a. Motor Rewinding Nos. 5 12,188.00 60,940.00
Digitally signed by VARUN
d. Motor Opening Fitting and Alignment Charges Nos. 5 4,500.00 22,500.00
vi 7.5 H.P High Pressure Pump Grandfoss Motor
a. Motor Rewinding Nos. 2 5,500.00 11,000.00
c. Bearing 6206 SKF Nos. 2 450.00 900.00
d. Motor Opening Fitting and Alignment Charges Nos. 2 2,000.00 4,000.00
vii 7.5 H.P Main Fire Pump IHT 10 BA Kirloskar Motor
a. Mechanical Seal Nos. 2 3,651.00 7,302.00
e. Neck Ring (Bronze) Nos. 2 4,500.00 9,000.00
f. Pump Opening Fitting and Alignment Charges Nos. 1 6,624.00 6,624.00
viii Diesel Engine Fire Pump IHT 12
a. Mechanical Seal Nos. 4 3,651.00 14,604.00
e. Neck Ring (Bronze) Nos. 4 4,500.00 18,000.00
f. Pump Opening Fitting and Alignment Charges Nos. 2 6,624.00 13,248.00
ix 7.5 H.P Jockey Pump Vertical Kirloskar Make Model KCIL 15-16
a. Mechanical Seal Nos. 1 3,250.00 3,250.00
e. Neck Ring (Bronze) Nos. 1 4,300.00 4,300.00
f. Pump Opening Fitting and Alignment Charges Nos. 1 4,000.00 4,000.00
x 12.5 H.P Jockey Pump RKB-50/15 L2
a. Mechanical Seal Nos. 4 3,651.00 14,604.00
c. Bearing NU 308 SKF Nos. 2 5,178.00 10,356.00
e. Sleeve S.S N.D.E Nos. 2 3,407.00 6,814.00
g. Coupling set Nos. 2 2,677.00 5,354.00
i. Pump Opening Fitting and Alignment Charges Nos. 2 6,624.00 13,248.00
xi 7.5 H.P Sprinkler Pump Kirlosker UP 150/45
a. Mechanical Seal Nos. 2 5,500.00 11,000.00
f. Pump Opening Fitting and Alignment Charges Nos. 1 6,624.00 6,624.00
xii Diesel Engine fire Pump Kirlosker Model RKB 125/27
a. Mechanical Seal Nos. 2 12,500.00 25,000.00
d. Sleeve S.S N.D.E Nos. 1 6,800.00 6,800.00
f. Bearing NU 312 SKF Nos. 1 8,944.00 8,944.00
g. O Ring Set Nos. 1 800.00 800.00
h. Pump Opening Fitting and Alignment Charges Nos. 1 10,000.00 10,000.00
xiii 20 H.P Domestic Pump Kirloskar Make RKB 50/15
a. Mechanical Seal Nos. 8 3,651.00 29,208.00
c. Bearing N.U 308 SKF Nos. 4 5,178.00 20,712.00
e. Sleeve S.S NDE Nos. 4 3,407.00 13,628.00
d. Coupling set Nos. 4 2,677.00 10,708.00
e. Pump Opening Fitting and Alignment Charges Nos. 4 6,624.00 26,496.00
xiv Sump Pump 2 H.P- 3 H.P
a. Motor Rewinding Nos. 30 2,000.00 60,000.00
b. Mechanical Seal Nos. 30 1,875.00 56,250.00
h. Impellar & Body Repair Nos. 30 2,000.00 60,000.00
i. Pump Opening Fitting and Alignment Charges Nos. 30 2,000.00 60,000.00
xv Sump Pump S.H.P Cutter Pump
a. Motor Rewinding Nos. 1 5,000.00 5,000.00
b. Mechanical Seal Nos. 1 3,200.00 3,200.00
e. O Ring Set Nos. 1 200.00 200.00
Digitally signed by VARUN
g. Pump Opening Fitting and Alignment Charges Nos. 1 3,000.00 3,000.00
xvi Sump Pump 7.5 H.P
a. Motor Rewinding Nos. 1 6,500.00 6,500.00
b. Mechanical Seal Nos. 1 3,450.00 3,450.00
e. O Ring Set Nos. 1 250.00 250.00
g. Pump Opening Fitting and Alignment Charges Nos. 1 3,000.00 3,000.00
xvii Sump Pump 10 H.P
a. Motor Rewinding Nos. 1 6,500.00 6,500.00
b. Mechanical Seal Nos. 1 3,875.00 3,875.00
d. O Ring Set Nos. 1 350.00 350.00
f. Pump Opening Fitting and Alignment Charges Nos. 1 4,000.00 4,000.00
xviii Sump Pump 12.5 H.P
a. Motor Rewinding Nos. 1 6,500.00 6,500.00
b. Mechanical Seal Nos. 1 3,875.00 3,875.00
e. O Ring Set Nos. 1 550.00 550.00
g. Pump Opening Fitting and Alignment Charges Nos. 1 4,000.00 4,000.00
xix High Pressure Vertical Pump Model CR 45 20 H.P Grandfoss
a. Mechanical Seal Nos. 1 11,559.00 11,559.00
c. Carbone Bush For difusser Nos. 4 3,650.00 14,600.00
e. Bearing with Driver silicon Nos. 1 22,713.00 22,713.00
f. Pump Opening Fitting and Alignment Charges Nos. 1 6,624.00 6,624.00
xx High Pressure Pump 7.5 H.P Grandfoss Make Irrigation Pump
a. Mechanical Seal Nos. 1 8,575.00 8,575.00
c. Diffuzer New Nos. 6 4,850.00 29,100.00
d. Diffuzer Repair Nos. 6 1,000.00 6,000.00
e. Impeller New Nos. 6 3,500.00 21,000.00
f. Impeller Repair Nos. 6 500.00 3,000.00
f. Neck Ring Nos. 6 625.00 3,750.00
f. Pump Opening Fitting and Alignment Charges Nos. 1 4,000.00 4,000.00
xxi Lowara Make Vertical High Pressure Pump 15 H.P Model SV 66
a. Mechanical Seal Nos. 2 11,450.00 22,900.00
f. Pump Opening Fitting and Alignment Charges Nos. 2 6,624.00 13,248.00
xxii Lowara Make Vertical High Pressure Pump 7.5 H.P Model SV 33
a. Mechanical Seal Nos. 2 11,450.00 22,900.00
f. Pump Opening Fitting and Alignment Charges Nos. 2 4,000.00 8,000.00
Supply, installation, Testing and commissioning of 3 phase and Neutral 415V 4 wire free standing Floor mounted Indoor MV panel made out of 14 SWG MS sheet aafter seven tank
process and painting with Epoxy powder coating:
Incoming: 630A,50KA TP+N MCCB with overload short circuit, earth leakage with relay CBCT-1set
Busbars:630A, TPN Aluminium busbar-1set
ac NS Outgoings: 125A,10KA TPN MCCBs- 8nos Set 1.00 352326.00 3,52,326.00
63A, 10KA TPN MCBs - 8 nos.
70A AC1 contractor with 230V coil and time switch similar ro L&T TSQ 100-1set
Metering: Digital MFM (V,A,F, KWH)-1 no., 0-500V Digital voltmeter with selector switch and MCB- 1 set
LED phase indications lamps with individuals MCBs and control and with toggle swithes-2sets
CT operated load manager-1set
Digitally signed by VARUN
MAIN BLOCK PANEL:
Supply, installation, Testing and commissioning of 3 phase and Neutral 415V 4 wire free standing Floor mounted Indoor MV panel made out of 14 SWG MS sheet aafter seven tank
process and painting with Epoxy powder coating:
Incoming: 250A,35KA TP+N MCCB with overload short circuit, earth leakage with relay CBCT-1set
Busbars:250A, TPN Aluminium busbar-1set
100A,10KA TPN MCBs- 4nos
63A, 8 Nos FP MCB
70A AC1 contractor with 230V coil and time switch similar ro L&T TSQ 100-1set
Metering:Digital MFM (V,A,F, KWH)-1 no., 0-500V Digital voltmeter with selector switch and MCB- 1 set
LED phase indications lamps with individuals MCBs and control and with toggle swithes-2sets
CT operated load manager-1set
PLUMBING PANEL-1
Incoming: 100A,35KA TP+N MCCB with overload short circuit, earth leakage with relay CBCT-1set
Busbars:150A, TPN Aluminium busbar-1set
Outgoings: 63A,10KA TP MCBs- 3nos
40A, 10KA TP MCB-3no
ae NS 70A AC1 contractor with 230V coil and time switch similar or L&T TSQ 100-1set Set 1.00 326702.00 3,26,702.00
Metering:Digital MFM (V,A,F, KWH)-1 no., 0-500V Digital voltmeter with selector switch and MCB- 1 set
LED phase indications lamps with individuals MCBs and control and with toggle swithes-6sets
CT operated load manager-1set
PLUMBING PANEL-2
Incoming: 100A,35KA TP+N MCCB with overload short circuit, earth leakage with relay CBCT-1set
Busbars:150A, TPN Aluminium busbar-1set
Outgoings: 63A,10KA TP MCBs- 3nos
12KW/SD-3, 70A AC1 contractor with 230V coil and time switch similar ro L&T TSQ 100-1set
Metering:Digital MFM (V,A,F, KWH)-1 no., 0-500V Digital voltmeter with selector switch and MCB- 1 set
LED phase indications lamps with individuals MCBs and control and with toggle swithes-6sets
CT operated load manager-1set
FLUSHIING WATER PANEL-1 PUMP NO-3/4-TYPE-IV
Incoming: 250A,35KA TP+N MCCB with overload short circuit, earth leakage with relay CBCT-1set
Busbars:150A, TPN Aluminium busbar-1set
Outgoings: 15KW-20HP-STAR Delta WITH VFD-6nos,
ag NS Metering:Digital MFM (V,A,F, KWH)-1 no., 0-500V Digital voltmeter with selector switch and MCB- 1 set Set 1.00 1089007.00 10,89,007.00
LED phase indications lamps with individuals MCBs and control and with toggle swithes-6sets
CT operated load manager-1set
All vd feeders will have filters/ chock
Auto and manual switch reqire for vfd
ON/OFF TRIP STATUS
IRRIGATION PANEL
Incoming: 100A,35KA TP+N MCCB with overload short circuit, earth leakage with relay CBCT-1set
Busbars:150A, TPN Aluminium busbar-1set
Outgoings: 5.5KW-7.5HP-STAR Delta WITH VFD-4nos,
Metering:Digital MFM (V,A,F, KWH)-1 no., 0-500V Digital voltmeter with selector switch and MCB- 1 set
ah NS LED phase indications lamps with individuals MCBs and control and with toggle swithes-6sets Set 1.00 704652.00 7,04,652.00
CT operated load manager-1set
All vd feeders will have filters/ chock
Auto and manual switch reqire for vfd
ON/OFF TRIP STATUS
ai NS Supply and laying of 3 mm thick 11KV grade rubber Mats as per IS 15652 of size 1000mmX2000mm NO 10.00 1800 18,000.00
Supplying, Installation, Testing and commissioning Sewerage submersible cutter type pumping sets of CI casing & impeller, SS shaft, including with
inbuilt water level sensors for operating the pumps automatically, starter with push button arrangement and all accessories suitable for operation on
aj NS 220 V-240 V, single phase/ three phase, 50 Hz. AC supply etc. all panels should be MCB isolation DOL/ SD Starter + Push Button on/off indicating Set 8 76,871.00 6,14,968.00
lamp, single phase preventor as required for each set of pump as reqd.
40 mm solid handling capacity, 3HP, Minimum Capacity-150 LPM, Minimum Head - 25 Mtr, complete as required.
Required for Location :- 02 Set for Type-II&III, 02 Set for Type-IV, 02 Set for Type-V, 02 Set for Type-VI&VII
Supply & Installation of Non-Metallic Exhaust Fan of 250/300mm.Ref make Havells, Model: Thrill Air DX Domestic Exhaust Fan or equivalent from other
approved makes)
Supplying, Installation, Testing and commissioning of Non-clog fully automatic Dewatering (Sewage) Pump, 5 HP, Three Phase, 415 Volts, Size 65mm.
Handling type of Screened sewage, Raw sewage' Contaminated effluents, Industrial waste water, Storm water, Trench and tunnel water, Drain water, mine
water, etc. Motor is dry type submersible and cooled by liquid being handled. Motors are air tested for leakfree operation. Degree of protection for motor is
al Non-DSR IP68 as per IS:2147 Class of insulation : F, Voltage : 415V 10%, Frequency : 50 Hz. 5%, Type of starting : As per requirement (DOL/Star Delta/ATS), Non- Set 6 86,188.00 5,17,128.00
clog two vane or single vane enclosed impeller, Permissible solid size up to 40 mm, Gland packed/mechanical seal, 50 HZ/60 HZ availability , Delivery size
up to 65 mm, Capacity up to 720 m3/hr, Head up to 25 metres. ( reference make: Kirloskar model ETERNA 3700 CW+ or equivalent from approved makes),
Minimum Capacity - 1200 LPM, Minimum Head - 25 Mtr, Minimum Power - 5HP/3.7 KW
am Indoor Luminaries Light fixtures
i Non-DSR Supply of Surface Mounted Light Fixture with 1 X 28 watt LED tube light complete as required. Nos. 20 196.70 3,934.00
ii Non-DSR Supply of Surface mounted Mirror LED tube Light with 1 X 10 watt complete as required. Nos. 20 207.60 4,152.00
Digitally signed by VARUN
iii Non-DSR Supply of 9 watt Wall Bracket LED bulb complete as required. Nos. 20 76.00 1,520.00
iv Non-DSR Supply of Surface mounted square LED Light with 1 X 18 watt complete as required. Nos. 20 902.00 18,040.00
v Non-DSR Supply of Surface mounted circular LED Light with 1 X 09 watt complete as required.for staircase Nos. 20 746.35 14,927.00
vi Non-DSR Supply of Surface mounted square LED Light with 1 X 18 watt complete as required.for lift lobby. Nos. 20 902.00 18,040.00
vii Non-DSR Supply of Surface mounted circular LED Light with 1 X 12 watt complete as required. Nos. 20 827.77 16,555.40
Supply, Installation, Testing & Commissioning of 5 Star rated enery efficient Inverter Split AC with all length piping, insulation, fitting, drainage pipe and
other accessories in all respect (Ref Model: Hitachi 2 Ton 5 Star ice Clean Xpandable Plus Inverter Split AC (100% Copper, Dust Filter, 2024 Model, Yoshi
an Non-DSR 5400FXL, R32-RAS.G522PCAISF, Dual Platinum). Nos. 16.00 67,297.00 10,76,752.00
Note: After installation Maintenance/repairing/repalcement of AC unit having same capacity/specification shall be under scope of contractor for which no
extra payments shall be paid by the department.
Sub Total of Special Repair Items 2,05,29,764.48 1,46,88,108.60
Digitally signed by VARUN
aoc.pdf
Download all tender documents and submit your bid