| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC NOT SPECIFIED | ₹1.2 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.2 Cr+₹3.4 L (2.85%)Rejected-Finance | ₹1.2 Cr+₹3.4 L (2.85%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹1.3 Cr+₹6.8 L (5.69%)Rejected-Finance 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | ₹1.3 Cr+₹6.8 L (5.69%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹1.3 Cr+₹14.5 L (12.0%)Rejected-Finance 340 11 M S NATIONAL ENGINEERING CORP 340 11 SATTI STREET ROORKEE ROORKEE HARIDWAR UTTARAKHAND 247667 | HARIDWAR | UTTARAKHAND | 247667 | ₹1.3 Cr+₹14.5 L (12.0%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹1.4 Cr+₹18.7 L (15.6%)Rejected-Finance | ₹1.4 Cr+₹18.7 L (15.6%) | L5 | Rejected-Finance BEING L5 |
| Sl No | Description | Qty | Unit | DIVYA ELECTRIC CORPOORATION L2 | M/s Prem Associates L10 | sapana enterprises L3 | United Sales Corporation L1 | Horizon Construction L6 | NATIONAL ENGINEERING CORPORATION L4 | UNIQUE ENGINEERS L11 | Shri Sai Electricals L12 | DARSHAN CONSTRUCTION Co. L5 | GEPS PROJECTS L7 | SHAILENDRA B TULSANI L8 | M B Electricals Pvt Ltd L9 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | 3 WAY RMU (2 I/C Isolator and 1 O/G VCB with PT )
Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 3 way Ring main unit out door type in combination of 2 nos LBS moduleas Incomer , 1 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated tank made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP 67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door,The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable Bushing and type tested Vacuum Interrupt of VCB should be from RMU manufacturer specified in CA. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old busbar chamber.
RMU Should have followings:
(i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder.
(ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A with class of accuracy 5P10 for proctection & 1 for metering for each VCB.
(iii) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation.
(iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA.
(v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger. | 3 | Each Job | 7,90,000 ₹23,70,000 | 10,00,000 ₹30,00,000 | 8,11,000 ₹24,33,000 | 6,75,000 ₹20,25,000 Lowest | 9,80,000 ₹29,40,000 | 8,75,000 ₹26,25,000 | 9,95,000 ₹29,85,000 | 10,50,000 ₹31,50,000 | 9,15,450 ₹27,46,350 | 9,00,000 ₹27,00,000 | 8,55,540 ₹25,66,620 | 8,47,500 ₹25,42,500 |
| 1.01(vi) 1 set 12VX2 , 26AH Battary along with charger. (vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (viii) 1 No. Manometer for each tank (ix) 1 nos. Voltage passage indicator for each feeder. (x) 1 Nos. FPI to be given to each LBS module (xi) Touch prooof screened cable termination kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided complete as as directed. (xii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided through out the bottom of RMU. (xiii) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC platform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughtout the length of RMU with width 600mm, depth below GL 600mm and of height suitabel to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xvi) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspection by SEI has to be carred out, contractor shall inform 45 days in advance for SEI precommissioning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorized dealer shall not be accepted. | |||||||||||||||
| 2.00 | 4 WAY RMU (2 I/C isolator and 2 O/G VCBs with PTs)
Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 4 way Ring main unit, outdoor type, in combination of 2nos LBS moduleas Incomer , 2 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated tank Made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door, The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable bushing and type tested Vacuum Interrupt of VCB should be from RMU manufacturer specified in CA Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old Busbar chamber.
RMU Should have followings:-
(i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder.
(ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A, with class of accuracy 5P10 for protection & 1 for metering for each VCB.
(iii) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation.
(iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA.
(v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger. | 1 | Each | 10,00,000 ₹10,00,000 Lowest | 13,50,000 ₹13,50,000 | 11,11,000 ₹11,11,000 | 10,75,000 ₹10,75,000 | 12,50,000 ₹12,50,000 | 11,75,000 ₹11,75,000 | 13,40,000 ₹13,40,000 | 14,00,000 ₹14,00,000 | 12,15,460 ₹12,15,460 | 12,42,000 ₹12,42,000 | 11,88,000 ₹11,88,000 | 10,95,000 ₹10,95,000 |
| 2.01(vi) 1 set 12VX2 , 26AH Battary along with charger. (vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (ix) 1 No. Manometer for each tank (x) 1 nos. Voltage passage indicator for each feeder. (xi) 1 Nos. FPI to be given to each LBS module (xii) Touch proof screened cable termination kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided compete all as directed. (xiii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided throughout the bottom of RMU. (xiv) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above Gi including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC plateform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xvi) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspection by SEI has to be carred out, contractor shall inform 45 days in advance for SEI precommissioning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorized dealer shall not be accepted. | |||||||||||||||
| 3.00 | 5 WAY RMU (2 I/C isolator and 3 O/G VCBs)
Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 5 way Ring main unit in combination of 2nos LBS moduleas Incomer , 3 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated Tank made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door, The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable Bushing and type tested Vacuum Interrupt of VCB should be from RMU Manufacturer specified in CA. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old busbar chamber..
RMU Should have followings:-
(i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder.
(ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A with class of accuracy 5P10 for protection & 1 for metering for each VCB.
(iv) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation.
(iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA.
(v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger.
(vi) 1 set 12VX2 , 26AH Battary along with charger. | 2 | Each | 12,80,000 ₹25,60,000 Lowest | 17,25,000 ₹34,50,000 | 14,11,000 ₹28,22,000 | 13,75,000 ₹27,50,000 | 16,15,000 ₹32,30,000 | 14,95,000 ₹29,90,000 | 16,90,000 ₹33,80,000 | 18,25,000 ₹36,50,000 | 14,95,520 ₹29,91,040 | 15,21,000 ₹30,42,000 | 15,13,800 ₹30,27,600 | 13,95,000 ₹27,90,000 |
| 3.01(vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (viii) 1 No. Manometer for each tank (ix) 1 nos. Voltage passage indicator for each feeder. (x) 1 Nos. FPI to be given to each LBS module (xi) Touch proof screened cable termination kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided complete all as directed. (xii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided throughout the bottom of RMU. (xiii) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC plateform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xiv) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC platform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xv) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspectio by SEI has to be carried out, contrator shall inform 45 days in advance for SEI precommisoning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15 days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorised dealer shall not be accepted. | |||||||||||||||
| 4.00 | 6 WAY RMU (2 I/C isolators and 4 O/G VCBs)
Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 6 way Ring main unit in combination of 2nos LBS moduleas Incomer , 4 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated Tank made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door, The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable bushing and type tested Vacuum Interrupt of VCB should be from RMU Manufacturer specified in CA. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old busbar chamber.
RMU Should have followings:-
(i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder.
(ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A with class of accuracy 5P10 for protection & 1 for metering for each VCB.
(iii) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation.
(iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA.
(v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger.
(vi) 1 set 12VX2 , 26AH Battary along with charger.
(vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder.
(viii) 1 No. Manometer for each tank
(ix) 1 nos. Voltage passage indicator for each feeder.
(x) 1 Nos. FPI to be given to each LBS module | 2 | Each | 17,00,000 ₹34,00,000 Lowest | 21,85,000 ₹43,70,000 | 18,11,000 ₹36,22,000 | 17,75,000 ₹35,50,000 | 20,70,000 ₹41,40,000 | 18,95,000 ₹37,90,000 | 23,66,000 ₹47,32,000 | 25,75,000 ₹51,50,000 | 18,61,620 ₹37,23,240 | 18,90,000 ₹37,80,000 | 19,39,950 ₹38,79,900 | 19,80,000 ₹39,60,000 |
| 4.01(xi) Touch proof screened cable terminaiton kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided complete all as directed. (xii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided throughout the bottom of RMU. (xiii) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC plateform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xv) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspectio by SEI has to be carried out, contrator shall inform 45 days in advance for SEI precommisoning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15 days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorised dealer shall not be accepted. | |||||||||||||||
| 5.00 | Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured underground, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade earthed system, of size 3 core 185 sq mm ISI marked complete all as specified and directed by Engr-in-Charge. | 60 | RM | 1,545 ₹92,700 | 1,843 ₹1,10,580 | 1,530 ₹91,800 | 1,500 ₹90,000 | 1,354 ₹81,240 Lowest | 1,585 ₹95,100 | 1,680 ₹1,00,800 | 1,580 ₹94,800 | 1,500 ₹90,000 | 1,800 ₹1,08,000 | 2,126.7 ₹1,27,602 | 1,642.5 ₹98,550 |
| 6.00 | Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, underground electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 120 sq mm ISI marked complete all as specified and directed by Engr-in-Charge. | 75 | RM | 1,131 ₹84,825 | 1,392 ₹1,04,400 | 1,170 ₹87,750 | 1,150 ₹86,250 | 1,050 ₹78,750 Lowest | 1,210 ₹90,750 | 1,300 ₹97,500 | 1,350 ₹1,01,250 | 1,100 ₹82,500 | 1,330 ₹99,750 | 1,557 ₹1,16,775 | 1,275 ₹95,625 |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
16 Jun 2025, 6:00 pmClosed
COL SP SINGH
CWE (AF), MILITARY ENGINEERS SERVICE LOHEGAON PUNE - 411032
PROVN OF RMUs FOR IMPROVEMENT OF HT NETWORK TECH AND DOMESTIC AREA AT AIR FORCE STN PUNE
2025_MES_707653_1
81936/E8
Open Tender
Civil Works
Item Rate
330 days
GE AF LOHEGAON PUNE
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE AF LOHEGAON
₹2.2 L
Yes
27 Sept 2025
10 May 2025
23 Jun 2025
10 May 2025
16 Jun 2025
11 Jun 2025
Amount
3 WAY RMU (2 I/C Isolator and 1 O/G VCB with PT ) Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 3 way Ring main unit out door type in combination of 2 nos LBS moduleas Incomer , 1 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated tank made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP 67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door,The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable Bushing and type tested Vacuum Interrupt of VCB should be from RMU manufacturer specified in CA. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old busbar chamber. RMU Should have followings: (i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. (ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A with class of accuracy 5P10 for proctection & 1 for metering for each VCB. (iii) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation. (iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA. (v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger.
(vi) 1 set 12VX2 , 26AH Battary along with charger. (vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (viii) 1 No. Manometer for each tank (ix) 1 nos. Voltage passage indicator for each feeder. (x) 1 Nos. FPI to be given to each LBS module (xi) Touch prooof screened cable termination kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided complete as as directed. (xii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided through out the bottom of RMU. (xiii) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC platform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughtout the length of RMU with width 600mm, depth below GL 600mm and of height suitabel to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xvi) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspection by SEI has to be carred out, contractor shall inform 45 days in advance for SEI precommissioning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorized dealer shall not be accepted.
4 WAY RMU (2 I/C isolator and 2 O/G VCBs with PTs) Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 4 way Ring main unit, outdoor type, in combination of 2nos LBS moduleas Incomer , 2 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated tank Made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door, The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable bushing and type tested Vacuum Interrupt of VCB should be from RMU manufacturer specified in CA Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old Busbar chamber. RMU Should have followings:- (i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. (ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A, with class of accuracy 5P10 for protection & 1 for metering for each VCB. (iii) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation. (iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA. (v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger.
(vi) 1 set 12VX2 , 26AH Battary along with charger. (vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (ix) 1 No. Manometer for each tank (x) 1 nos. Voltage passage indicator for each feeder. (xi) 1 Nos. FPI to be given to each LBS module (xii) Touch proof screened cable termination kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided compete all as directed. (xiii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided throughout the bottom of RMU. (xiv) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above Gi including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC plateform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xvi) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspection by SEI has to be carred out, contractor shall inform 45 days in advance for SEI precommissioning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorized dealer shall not be accepted.
5 WAY RMU (2 I/C isolator and 3 O/G VCBs) Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 5 way Ring main unit in combination of 2nos LBS moduleas Incomer , 3 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated Tank made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door, The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable Bushing and type tested Vacuum Interrupt of VCB should be from RMU Manufacturer specified in CA. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old busbar chamber.. RMU Should have followings:- (i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. (ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A with class of accuracy 5P10 for protection & 1 for metering for each VCB. (iv) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation. (iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA. (v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger. (vi) 1 set 12VX2 , 26AH Battary along with charger.
(vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (viii) 1 No. Manometer for each tank (ix) 1 nos. Voltage passage indicator for each feeder. (x) 1 Nos. FPI to be given to each LBS module (xi) Touch proof screened cable termination kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided complete all as directed. (xii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided throughout the bottom of RMU. (xiii) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC plateform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xiv) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC platform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xv) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspectio by SEI has to be carried out, contrator shall inform 45 days in advance for SEI precommisoning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15 days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorised dealer shall not be accepted.
6 WAY RMU (2 I/C isolators and 4 O/G VCBs) Supply , install, testing and commissioning of 11kV 630 Amps 21KA for 3 Sec. SF6 insulated, One side extensible, outdoor duty fully motorized 6 way Ring main unit in combination of 2nos LBS moduleas Incomer , 4 nos. VCB modules (ougoings) consisting of copper busbar in SF6 insulated Tank made out of 304 (Non-Ferrite Non-Magnetic Grade) stainless steel enclosure of thickness 2.5mm IP67 protection with monometer fixed, with series trip, self-powered microprocessor based numerical over current relay (IDMTL + Inst.) in each VCB feeder. The HV switchgear and control gear should be confirming to IEC-62271-1, 100, 200. The RMU should be internal arc tested for 21KA for 1Second with IAC-AFLR classification for gas tank & cable box. The complete RMU shall have external outdoor type IP54 cover made out of GI sheet 1.6mm thick duly powder coated and shall be front openable with door and back openable sheets, cable chamber covered by a separable inner & outer door, The RMU shall have ingress protection of minimum IP54. The RMU should be provided with replaceable HT cable bushing and type tested Vacuum Interrupt of VCB should be from RMU Manufacturer specified in CA. Each feeder of should have voltage presence indicator. All the type test certificated as per IEC from Third party lab to be submitted including taking down old busbar chamber. RMU Should have followings:- (i) 1 no. microprocessor based Self powered numerical relay with over Current/ earth fault & short circuit protection with each VCB feeder. (ii) Each outgoing VCB shall have 3 Nos dual core C.T. for metering & protection with burden 2.5VA, ratio 100-50/1A/1A with class of accuracy 5P10 for protection & 1 for metering for each VCB. (iii) VCB should confirm operating sequence O-0.3Sec-CO-3min-CO and 2000 mechanical operation. (iv) 3 nos. 1 ph 11KV/110V PT having accuracy class 0.5 & VA burder 50VA. (v) 1 no. 1 Ph 11KV/230V, 500VA, Auxiliary Transformer for battary charger. (vi) 1 set 12VX2 , 26AH Battary along with charger. (vii) Multimuction Meter (RMU manufacturer's own Make) with Accuracy class 0.5 for each VCB feeder. (viii) 1 No. Manometer for each tank (ix) 1 nos. Voltage passage indicator for each feeder. (x) 1 Nos. FPI to be given to each LBS module
(xi) Touch proof screened cable terminaiton kit 11KV as per OEM Recommendation of suitable size for incoming & out Going 11000 Volts cables as per site requirement shall be provided complete all as directed. (xii) The scope includes provision of MS channel stand made out of MS Channel of 75mm x 50mm x 10mm thick and of height of 600mm for mounting panel in PCC foundation, the channel shall be provided throughout the bottom of RMU. (xiii) The scope includes PCC foundation 1:2:4, 20mm grade of height 450mm below GL & 450mm above GI including excavation and removal & foundation shall be width 450mm and provided on both edges of the RMU and PCC plateform 20mm aggregate 1:2:4 shall be provided on front side of RMU throughout the length of RMU with width 600mm, depth below GL 600mm and of height suitable to match with RMU bottom plate, including excavation and removal in any kind of soil/strata. (xv) The scope includes any accessories recommended by OEM for smooth functioning has to be incorporated and cost of same is deemed to be included in quoted rates. (xvii) Precommissioning inspectio by SEI has to be carried out, contrator shall inform 45 days in advance for SEI precommisoning. (xviii) Predispatch factory inspection to be carried by the rep of Accepting Officer and cost of same deemed to be included in quoted rates. (xix) The technical specification and drawing shall be submitted by the contractor within 15 days of issue of work order and shall be got approved by the accepting Officer. (xx) The RMU shall be manufactured/Assembled, tested from OEM factory and manufacturing from OEM authorised dealer shall not be accepted.
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured underground, electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade earthed system, of size 3 core 185 sq mm ISI marked complete all as specified and directed by Engr-in-Charge.
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, underground electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 120 sq mm ISI marked complete all as specified and directed by Engr-in-Charge.
Supplying laying & testing of XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, underground electric power cables (heavy duty) with stranded aluminum conductor, 11000 volts grade, earthed system of size 3 core 95 sq mm ISI marked complete all as specified and directed by Engr-in-Charge.
Material and labour for taking out of serviceable HT cable 11 KV of any size from any type of soil strata complete all as specified and directed by Engr-in-Charge.
Material and labour for relaying of serviceable HT cable 11 KV of any size sqmm taking down under above item No 8 Note: Excavation work and crushed sand, precast conrete cable cover etc willl be measured and paid seperately under subsequent items
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft/loose soil etc complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole in soft disintegrated rock complete all as specified and directed by Engr-in-Charge.
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point complete all as specified and directed by Engr-in-Charge.
M&L for crushed stone sand cushioning to UG cable, provide with the layer 8 cm before and 15 cm after laying and punning down and testing the cable complete all as specified and directed by Engr-in-Charge. Note :- Thickness of sand after punning will be measured and paid.
Supplying and laying unreinforced precast concrete cable cover, class HV, type 1 flat of size 300mm x180mm x 40mm placed perpendicular to the cable complete all as specified and directed by Engr-in-Charge.
Supply and fix GI Pipe Light grade with all connected accessories of sizes 100 mm dia complete all as specified and directed by Engr-in-Charge.
Cutting of existing road not exc 1.5 mtr in depth and not exceeding 1.5 mtr wide after laying of RCC /GI pipe under road making good in all respect to match with the existing surface all as directed by E-in-charge.
S&F in repairs cable end joint kit 95 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type, complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable end joint 120 to 185 Sqmm, 3 core XLPE 11kV HT Cable heat shrinkable indoor / outdoor type complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable straight through joint 95 Sqmm, 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed by Engr-in-Charge.
S&F in repairs cable straight through joint 120 to 185 Sqmm 3 core XLPE 11KV HT Cable heat shrinkable complete including necessary excavation and earth work complete all as specified and directed by Engr-in-Charge.
M&L for fabricating, supplying, installing, testing & commisioning of Outdoor type manufactured by CPRI approved manufacturer made HT 11 KV feeder pillar box of size not less than 165 x 80 x 117 cm with top cover 5 cm projected allround made with 3 mm thick CRCA sheet, weather proof, vermin proof with double door, handle with locking arrangement, powder coated with 7 tank process including PVC insulated copper bus bar 3 nos size of 130cm x 5 cm x 0.5cm & mounted on HT 11 kV insulators 9 nos (three nos per bus bar) insulators should be mounted on MS sheet with thickness 3mm made in shape including weather proof painting. The feeder pillar box should be mounted on ms frame made up with MS Angle of size 60mm x 60mm x 6mm with height 750mm duly covered with MS sheet 3 mm thick on all sides about 35 cm from the bottom of the FPB & all side removeable type including two coats of syntheic enamel paint over one coat of red oxide primer including necessry excavation earth work in any type of soil, pcc block (1:3:6) of size 120x25x60cm- 2nos embedded in ground etc complete including writing name of feeders on FPB with size of letters not less than 10 cm all as directed by Engr-in-Charge. Note : (i) Contractor shall submit layout drawing of panel and shall be got approved from GE. (ii) Factory Test Report of the panel shall be submitted.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm as earthing lead buried directly in groungd vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to and including galvanised iron strip 32 X 6 mm as earthing lead by means of bolts, nuts, checknuts and washers etc made of GI and connected earthing test points all as shown in electrical plate no. 5 of SSR Part-1 of 2009.00 and as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC (1:3:6) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete (1:2:4) type B1 (reinforced with welded steel wire fabric (XPM) weight not less than 4 kg/sqm) funnel with grade and lugs, including galvanised iron strip 32 X 6 m with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified and directed by Engr-in-Charge
M & L for disconnect of existing 2 Nos VCBs from GCA Power House and 03 Nos VCBs from Base Ops Sub Stn , fitting, transporting to NP power House and connecting coupling to cxisting VCB at NP power house as per requirement including providing busbar & bus Duct arrangement for coupling the breakers and coupling with existing breakers and testing complete as as required and commissioned compete as directed at site
M & L PCC type D2 1:4:8 (40 mm graded agregate in foundations, filling and mass.
M & L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete set in cement mortar 1:4,Type C1, 1:3:6 (20 mm graded aggregate)
Material and labour for cement plaster work 10 mm thick in 1:4 rendering on fair faces of brick work or concrete surfaces and finishing to be carried out one even and smooth surface (without using extra lime or cement)
Supply and fix Angle Iron or FIat Iron or Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;
Supply and fix angle iron/ Channel /Framed work such as grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 as in post and strut in fencing/Pole including cutting tops to shape as directed , drilled holes, notching for wire, etc flat iron fillets (for securing wire mesh etc) including all necessary drilling bolting or riveting etc all as specified and direted by Engr-In-Charge.
Material and labour for preparation of new steel surface of any description, over 10 cm in width or girth,not otherwise described with one red oxide coat and two coat of black bituminious paint / synthetic paint coat all as required on site and directed by Engr-in-Charge
Suplly only Chain link MS galvanisd fencing, any size or type
Fixing only Chain link MS galvanisd fencing, any size or type
S & F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 5cm but n exc 10cm long all as specified and directed by Engr-In-Charge
S & F Chimney bars (straight or camber); bearing bars; tongues or water bars for window frames; window guard bars, plain, let in and fixed independently in wooden frames, L or T section supports for shelves etc. and similar articles conforming to Fe-290 Gde E-165 all as specified and directed by engr-in-Charge
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground all as specified and directed by Engr-In-Charge
DIVYA ELECTRIC CORPOORATION (BID ID -3322614)
sapana enterprises (BID ID -3324654)
NATIONAL ENGINEERING CORPORATION (BID ID -3325025)
DARSHAN CONSTRUCTION Co. (BID ID -3325254)
Horizon Construction (BID ID -3325000)
GEPS PROJECTS (BID ID -3325447)
SHAILENDRA B TULSANI (BID ID -3320837)
M B Electricals Pvt Ltd (BID ID -3323504)
M/s Prem Associates (BID ID -3323082)
UNIQUE ENGINEERS (BID ID -3325047)
Shri Sai Electricals (BID ID -3325221)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .