Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC | ₹8.8 L | L1 | Accepted-AOC Quoted rates of lowest bidder found reasonable hence accepted |
| 2 | L2₹9.0 L+₹16,409.70 (1.86%)Rejected-AOC | ₹9.0 L+₹16,409.70 (1.86%) | L2 | Rejected-AOC Quoted rates are high hence rejected |
| 3 | L3₹9.3 L+₹52,357.47 (5.95%)Rejected-AOC | ₹9.3 L+₹52,357.47 (5.95%) | L3 | Rejected-AOC Quoted rates are high hence rejected |
| 4 | L4₹9.5 L+₹70,633.53 (8.02%)Rejected-AOC | ₹9.5 L+₹70,633.53 (8.02%) | L4 | Rejected-AOC Quoted rates are high hence rejected |
| 5 | L5₹9.7 L+₹93,473.25 (10.6%)Rejected-AOC | ₹9.7 L+₹93,473.25 (10.6%) | L5 | Rejected-AOC Quoted rates are high hence rejected |
Tender Value
₹9.3 L
EMD Value
₹18,500
Closing Date
20 Jun 2023, 6:00 pmClosed
Mr GURUDAS GOLDAR, AE (CIV)
AGE (I) TAWANG Pin- 900198 C/o 99 APO
REPAIR / MAINTENANCE OF MISC E/M SERVICE AND OTHER ALLIED WORKS AT 106 FD WKSP, 384 ASC COY, 277 TRANSIT CAMP AND B DET UNDER AGE (I) TAWANG
2023_MES_599558_1
8566/AGE(I)/TWG OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
Tawang
REFER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
AGE (I) TAWANG
₹18,500
31 Aug 2023
30 May 2023
27 Jun 2023
30 May 2023
20 Jun 2023
13 Jun 2023
30 May 2023 - 6 Jun 2023
Amount
Dismantling and taking up or down old Unserviceable service cable and LT UG cable of any size complete all as specified and directed
Supply and Laying and connecting with appropriate lugs in replacement XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
All as per Item No 2 above but 10 Sqmm 4 Core.
All as per Item No 2 above but 35 Sqmm 3.5 Core.
All as per Item No 2 above but 50 Sqmm 3.5 Core.
All as per Item No 2 above but 70 Sqmm 3.5 Core.
Excavation in trenches, not exc 1.5m wide and not exc 1.5m in depth, for foundation, etc or for shafts, wells, cess-pits, menholes, pier holes, etc. not exc 10 sq m on plan and not exc 1.5m in depth and getting out in soft & loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, waterring and wall ramming in layers not exc 25 cm. for any type of soil complete all as specified and directed.
Removing excavated soil not exc. 50 m and depositing where directed at a layers not exc 1.50 m. above/below the starting point complete all as specified and directed.
Supply and laid in trenches double walled corrugated HDPE pipes of inner dia 50 mm and outer dia 63 mm, as in cable protection work, complete all as specified and directed.
Supply and laid in trenches double walled corrugated HDPE pipes of inner dia 63 mm and outer dia 75 mm, as in cable protection work, complete all as specified and directed.
Supply and fixing in repair of MCCB 63 amps 4 pole 25 KA 415 volt complete including taking down old unserviceable one complete all as specified & directed.
Supply and fixing in repair of MCCB 100 amps 4 pole 25 KA 415 volt complete including taking down old unserviceable one complete all as specified & directed.
Materials and labour for earthing complete with galvanised steel earth plate electrode 60cmX60cmX6mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level)with top edge of the plate not less than 1.5 metres below normal groundlevel, connected to galvanised earth lead strip 32x6mm by means of volts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No-3 of SSR Part-I connected to earthing test point all as specified or indicated including excavation and connected earth work in hard/dense soil, PCC 1:3:6 type C-1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 15 mm bore GI medium grade earth lead protection pipe, 50 mm thick RCC 1:2:4 type B-1 cover slab of earth pit reinforced with 8 mm dia TMT bars @ 10 cm C/C both ways and with handle made out of 10 mm dia bars, funnel, strainer, charcoal and testing on completion complete all as specified and directed.
Materials and labour for replacement GI pipe light grade with all fittings complete grouted in ground all as specified for 50 mm bore of pipe laid in trenches/fixed with poles/laid in road/plinth/floor for protection of cable complete all as specified and directed.
Supply and fixing in repair LT Over over head line phase seperator of any size (2 way) in between distribution span of LT over head lines all as directed by the Engr-in-charge.
Supply and fixing cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories, Outdoor type suitable for size 10 to 16 sqmm 3.5/4 Core.
All as per Item No 17 above but 25 to 50 sqmm 3.5/ 4 Core.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner shethering of PVC tape armoured with galvanised steel wire or tape and overall PVC shetered 10 Sqm 2 Core nominal cross section in sevice connection including taking down old unserviceable service wire complete all as specified.
Supply and laying or fixing or passing through pipe 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner shethering of PVC tape armoured with galvanised steel wire or tape and overall PVC shetered 16 Sqm 2 Core nominal cross section in sevice connection including taking down old unserviceable service wire complete all as specified.
Supply and fixing in repair aluminium lugs for 10 Sqmm size complete all as specified and directed
All as per item ser No 21 above but 16 Sqmm
All as per item ser No 21 above but 35 Sqmm
All as per item ser No 21 above but 50 Sqmm
All as per item ser No 21 above but 70 Sqmm
Supply and fixing in repair weather proof hot press moulded SMC junction box / street light control box with side hinged door of size 250mm x 200 mm x 105 mm (approx) complete with hinged door locking arrangement and consisting of 2 Nos of suitable size cable glands consisting of 01 No panel mounted connector 4 pole MCB 6A 10KA 01No, including connecting up with the electrical connections and fixing and clamping complete and all as directed.
Taking down unserviceable street light LED fitting/Flood light of any wattage and type from the pole/building of any height including disconnecting the cable connections for repairing of light fittings and refixing in same position after repair and connecting all as specified and directed. Note : (i) Spares shall be measured and paid seperatly under relevent items as supply only. (ii) The cost of replacing of internal connections, screws, bolts, minor spares etc. to make the fittings serviceable shall deemed to be included in the quoted cost.
Supply only Electronic Driver for street light/Flood light fitting 25 to 50 Watts.
Supply and fix Electronic Driver for street light fitting/Flood light fitting 60 to 100 watts.
Supply only LED plate for street light/Flood light fitting 25 to 50 Watts.
Supply and fix LED plate for street light fitting/Flood light fitting 60 to 100 watts.
Taking down unserviceable LED Garden/Post top lantern/path light fitting of any wattage and type from existing position of any height including disconnecting the cable connections for repairing of light fittings and refixing in same position after repair and connecting all as specified and directed. Note : (i) Spares shall be measured and paid seperatly under relevent items as supply only. (ii) The cost of replacing of internal connections, screws, bolts, minor spares etc. to make the fittings serviceable shall deemed to be included in the quoted cost.
Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 5 to 15 Watts.
Supply only Electronic Driver for Garden/Post top lantern/Path light fitting 20 to 45 Watts.
Supply only LED plate for Garden/Post top lantern/Path light fitting 5 to 15 Watts.
Supply only LED plate for Garden/Post top lantern/Path light fitting 20 to 45 Watts.
Taking down unserviceable wiring and materials and labour for wiring for circuit/submain wiring with 2 x 1.5 sq mm FRLS, PVC insulated copper conductor, single core cable alongwith earth wire 1.5 sqmm with the of FRLS is PVC insulated copper conductor, single core cable drawn through and including non metallic PVC rigid conduit(20mm dia) from junction box to street/flood light fitting on pole of any height as required all as specified and directed by Engr in charge. Note:-Two runs of cable copper conductor and non metallic PVC conduit shall be measured as one unit length.
Taking down unserviceable post top lantern and supply and fixing new LED post top lantern fitting 40 watts on existing pipe of any size and height, IP 65 protection, spun aluminium landscape luminaire with high power LEDs as light source, clear cover for bright illumination, with all accessories prewired, fixed on poles complete all as directed. (Make :Havells Cat part No RUBYPT40WLED757PSYMTOPC or CG Cat part No LPTO-40-CDL or equivalent of Wipro/Bajaj)
Taking down unserviceable garden light and supply and fixing new LED garden light, 10 watt, sturdy IP 65 protection LED bollard with excellent light output through PMMA window ensuring maximum illumination aspect in sorrounding, fixed on existing base/pipe of any size and height with all accessories prewired fixed with suitable clamps, nuts, bolts etc. complete all as directed. (Make :Havells Cat part No MOUNTBL10WLED830TSYMTOPMMA or CG Cat part No LPTO-10-CDL or equivalent of Wipro/Bajaj)
Taking down unserviceable flood light from poles/building and supply and fixing new LED flood light fitting, 70 Watt integral type light fixture, IP 66 protection, die cast aluminum body, reflector, drivers, LEDs and accessories with system wattage 70 Watt complete all as directed. (Make :Havells Cat No: JETAALBAFLOODLIGHT70W or eequivelant of Philips/CG).
Taking down unserviceable street light from poles/building and supply and fixing new LED street light fittings 45 Watt ,environmental friendly long life, made up of pressure die cast aluminium housing with high power LED as lighting source with secondary optics and PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07. (Make : Cat Part No TRP-409-45-57-SL-NS-GL-NSG of CG or equivalent in Philips/CG/Havells).
Material & Labour for cutting the road/ hard standing for taking out/ laying pipe/cable, making good surface with PCC 1:3:6, Type C-1, Using 20 mm graded stone aggregate after laying pipe/cable and removing the debrish to a distance n.exe 50mtr all as directed.
Taking down unserviceable time switch and supply and fixing new street light Time switches, Digital 24 hour, 440 V 2 pole 32 Amps complete all as specified and as directed. (Make: Havells or equivelant in Legrand/L&T).
Laying only old servicable XLPE LT cable PVC insulated, heavy duty electric cables with Aluminum conductors,1100 volts grade, laid in trenches/on pole/in pipe /on wall ,using suitable clamps for fixing of cable complete all as specified and directed of cross-sectional area 10 Sqmm 2 Core.
Material and labour for two coats painting to LT steel tubular/RCC poles at the bottom from ground level towards upwards upto 2m height with black and yellow strips each 15 cm width on the poles with synthetic enamel paint including preparation of old painted surface and marking of pole number with white synthetic enamel paint over black colour base as per existing pattern all as specified and directed.
Supply and fixing Off load changeover switch side handle in sheet metal enclouser 415 V AC 50 Hz of capacity 100 amp 4 pole all as directed by the engineer in charge. Make : Havells/L&T or its equivalent
Supply and fixing Off load changeover switch side handle in sheet metal enclouser 415 V AC 50 Hz of capacity 125 amp 4 pole all as directed by the engineer in charge. Make : Havells/L&T or its equivalent
Locating electrical fault in UG cable of any size and repair by using of suitable size of cable lugs and straight through joint and make the good disturbed surfaces all as specified and directed by Engr-in-charge. Note :- Cable joint kit, Earth work & Aluminium lugs will be measured and paid seperately in respective items.
Taking down carefully old rusted/broken bracket with serviceable light fittings from the pole after disconnecting, supply and fix new bracket for street light fitting made out of 32 mm dia light grade GI tubing bent to required shape 1.5m long including necessary GI clamps, nuts bolts and washers, refixing and connecting old serviceable light fitting, fixing to the pole complete all as directed.
Material and labour framed work as such as grills, gratings, etc with ends of bars shouldered and /or riveted, or forged into spikes; framed guard baars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con-forming to Fe.290.Gde-E-165
Material and labour for GI strip of size 32x6m as earth continuity conductor burried in ground or drawn in pipe or fixed to wall on saddle all as specified and directed
Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm
Materials and labour for carrying out 'B' check comprising replacement of fuel filters,oil filters,air filter element,changing lubricating oil, cleaning of fuel lines,checking leakges if any, repair the leakge, replacement of exhaust fan,gasket etc complete all as specified and directed for DG set 125 KVA complete all as specified and directed.
Materials and labour for carrying out 'B' check comprising replacement of fuel filters,oil filters,air filter element,changing lubricating oil,cleaning of fuel lines,checking leakges if any, repair the leakge, replacement of exhaust fan,gasket etc complete all as specified and directed for DG set 10 KVA complete all as specified and directed.
Supply and fixing new diode set in replacement of old unsv diode set for 10KVA DG set all as specified and directed
Supply and fixing in repair the unserviceable V belt of DG set capacity 125 KVA.
Supply and fixing in repair the unserviceable V belt of DG set capacity 10 KVA.
Material and labour for repair of self starter after removing from the DG set of capacity 125 KVA of any make and model all as specified and directed
Material and labour of dynamo after removing from the DG set of capacity 125 KVA of any make and model all as specified and directed
Material and labour of dynamo after removing from the DG set of capacity 10 KVA of any make and model all as specified and directed
Supply and topping up of electrolyte for lead acid battery.
Supply and topping up of distiled water for lead acid battery.
Supply and fixing in repair AVR (Model R-120) with functions to adjust generator output voltage ,prevent voltage hunting,set under frequency,roll of knee point,set generator drop to 5% at full load,match AVR input to necessary output,set the over excitation cut off level ,set initial frequency ,related voltage dip,over voltage protection cut off level,max short circuit current with sensing input voltage range 170 - 250 V AC max,50-60 Hz frequency with out put max up to 120 V DC,continious current 2.7 A & transient 6 A for 10 second including necessary control wiring complete from alternator to AVR complete testing & commissioning for DG set of capacity 125 KVA all as specified and directed by Engr in charge.
All same as item No.63 above but for DG set of capacity 10 KVA all as specified and directed by Engr in charge
Materials and labour for repair/servicing of UPS of capacity upto 5 KVA by checking all electrical connection and rewiring the same, replacing wornout parts and refix the same location or directed by Engr in charge including testing,commissioning complete. Note:- (i) PCB kit and By pass switch etc will be measured and paid sepeartaly as supply only. (ii) Minor parts e.g nut, bolt, screw, wiring etc are included in quoted rate.
Supply only PCB kit of UPS up to capacity of 5 KVA.
Sypply only bypass switch of UPS up to capacity of 5 KVA.
M/S G M BUILDERS
M/S K D CONSTRUCTION
M/S TSERING DHONDUP
M/S GLOBAL ROYAL CONSTRUCTION
M/S RHEGON CONSTRUCTION
M/S GOLANG CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .