DY. GENERAL MANAGER
Office of the Deputy General Manager, JKPCC Ltd., Unit Electrical, Rail Head Complex Jammu.
Internal Electrification Work of Gym and Indoor Stadium at GMC Jammu.
2022_PWDJK_186096_1
e-NIT No. 20/ELECT of 2022-23 Dt. 26-08-2022.
Open Tender
Electrical Works
Item Rate
90 days
JAMMU
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
Yes
Financial Controller, JKPCC Ltd
₹1.1 L
Yes
Dy. Gen Mgr, Elect. Unit, JKPCC Jammu
4 Nov 2022
30 Aug 2022
13 Sept 2022
30 Aug 2022
13 Sept 2022
30 Aug 2022
2 Sept 2022
Amount
Sub Head-I(Wiring) Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit,with modular switch, modular plates & suitable GI Box.Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture. (SB Controlled Primary light Points)
Looping above light point ( say secondary light point using 3 x 1.5mm2 stranded copper/FRLS PVC insulated wires laid in 20 mm Dia. PVC MMS conduit;with modular switch, modular plates & suitable GI Box;. . Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture. (SB Controlled Secondary light Points)
Providing Primary light point wiring using 2 x 2.5mm2 stranded copper/FRLS PVC insulated wires for phase and neutral and 1.5 sq mm green for earth laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture. (DB Controlled Primary light Points)
Looping above light point ( say secondary light point using 3 x 1.5mm2 stranded copper/FRLS PVC insulated wires laid in 25 mm Dia. PVC MMS conduit Conduits shall be cleated to the surface/walls with saddles and spacers as per engg practice. Rate to include all conduits and accessories, wires. complete and civil works and making good . For point wiring in areas with false ceiling, the point shall be terminated above the false ceiling next to the lighting fixture. (DB Controlled Secondary light Points)
Wiring for fan point/ exhaust Fan/call bell point with 1.5 sqmm. FRLS PVC insulated copper conductor single core cable in Surface/ recessed medium class PVC Conduit , with modular switch, modular plate, suitable G.I. box and earthing the point with 1.5sqmm FRLS PVC insulated copper conductor single core cable etc as required.
Wiring for Light /Power Plug with 2 x 4 sq.mm FRLS PVC Insulated Copper Conductor single core cable in surface/Recessed medium class PVC Conduit along with 1 No. 4 sq.mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for Circuit/Submain Wiring along with earth Wire with the following Sizes of FRLS PVC insulated copper conductor,single core Cable in surface/Recessed medium class PVC conduit as required.
2 X 2.5 SQ.MM + 1 X 2.5 SQ.MM EARTH WIRE
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 6 sq. mm earth wire
4 X 16.0 SQ.MM + 2 X 6.0 SQ.MM EARTH WIRE
25 sq.mm Multistrand Copper Conductor Wire IS:694
Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required
Supplying and Fixing suitable size G.I box with modular plate and cover in front on surface or in recess,including providing and fixing 3 pin 25 amps modular Multi pin socket outlet with connection,painting etc. as required.
Supplying and fixing Stepped Type Electronic Fan Regulator on the existing Modular Plate Switch Box including Connections but Excluding Modular Plate etc. as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Sub Head-III(DB's and MCB's). Supplying and fixing following way,Prewired TP&N PPI Distribution Board of Sheet Steel for 415 Volts on surface/Recess complete with Ready to use DBs - Provided with 100A insulated phase bus-bars,neutral bar/s with shroud/s, earth bar/s , sticking saddles , cement spill protector ,color-coded interconnecting wire set , cable ties , blanking plates and circuit identification labels.The D.B should be IK-09 Compliant.(The Cost of D.B is without MCB's)(IP Rating-43).
4Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(4+4+4) SP MCB's O/G's)
8Way (8 Module Incomer),(2+2+2 incomer DP RCCB),(8+8+8) SP MCB's O/G's)
Supplying,Installation ,Testing and Commissioning of Four Pole 415V ,MCB in the existing MCB DB With Connections Testing and Commissioning etc as Required.
Supplying and Fixing Following rating,Double Pole (Single Phase and Neutral),240 Volts Residual Current Circuit Breaker (RCCB) having a sensitivity of current upto 300 ma in the existing MCB DB Complete with connections ,testing and commissioning as required.
Supplying and fixing 5 amps. to 32 amps.rating 240 volts 'C' series, miniature circuit breaker of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supply and Fixing Single Pole Blanking Plate in the Existing MCB DB complete as Required
SITC of 3P+N(2 Module) Surge Protection Device Type 2 max. 15 KA
Supplying and Laying of B-Class 80 mm Dia Size G.I Pipe under the Road/Floor not less than 1 mtr below the Ground Level including cutting the Road/Floor and making Good the same as required.
Sub Head-IV (Lightning Conductor and Earthing) ENVIRONMENTALLY SAFE MAINTENANCE FREE EARTHING SYSTEM. Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance value. Supply, installation, testing and commissioning of Advanced Maintenance Free environment friendly Earthing system consisting of 1 no. of 3mtr length, 17.2 mm dia UL certified earth electrode made of high tensile low carbon steel circular rods, molecularly bonded copper on outer surface (minimum copper bonding thickness-250 microns) with GI terminals to connect incoming strips, (Environment friendly backfill compound duly certified as per ANSI/NSF standard 60/Toxic content certificate as safe for use near potable ground water resources strictly as per specification enclosed. Make- SHREE ELECTRODES/OBO BETTERMANN/ERICO or Equivalent make. Earth pit chamber (300mm x 300mm) with CI cover for the above.
Providing and Fixing 25 mm x 5 mm Copper Strip in 40 mm dia. G.I Pipe FRL Earth Electrode including connection with Brass nut ,bolt,spring,washer,excavation and refilling etc. as required.
Sub Head -V(SITC of Fans and Fittings). SITC of Ceiling Fan,Capacitor type suitable for low voltage operation including wiring the down rods of standard length(Upto 30 cm)with 1.5 sq.mm FR PVC insulated,copper conductor,single core cable including providing and fixing phenolic laminated sheet cover on the Fan Box etc as Required. 1200 MM SWEEP
SITC of pre-wired Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.(LH14-102-XXX)(78.5 W) / Equivalent make.
SITC of pre-wired Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.(LF07-282-090-V5)199W / Equivalent make.
SITC of pre-wired Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.(LD 80-171-XXX-60-XX WIPRO) / Equivalent make.
SITC of pre-wired Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.(LE-20491-XXX-57-XX) / Equivalent make.
SITC of pre-wired Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.(LM71-441-XXX-57-XX) / Equivalent make.
SITC of pre-wired Surface Mounted LED Ceiling Light Fitting including connections with 1.5 sq.mm FR PVC insulated copper conductor single core cable and earthing etc as required.(LH 09-851-060-50-V5)65 W / Equivalent make.
Supply of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required . 300 mm
Supply of AC 230/250 Volts, 50 Hz exhaust fan with louveres of Following Sizes including connection etc. complete as required . 450 mm
Supplying and Laying of 1 No. DWC High Density Poly ethylene Pipe having Corrugation on Outer wall and Plain surface inner wall Conforming to IS: 14930 Part-1 and 2 Complete with accessories for Protection of 1.1 KV Grade under Ground cable Directly in Ground at a Depth of 50 CM including excavation and Refelling the Trench Etc.as Required. 160mm/136mm .
Ground Cables and Accessories. Supply , loading , Transport ,Unloading , shifting ,laying, testing and commissioning of 11KV/1.1KV Grade XLPE/PVC insulated aluminium/copper multistrande conductor steel of armoured/flexible braid power cables as per the specification. Laying of Cables in horizontal/vertical formation on cable trays, supported along RCC/steel structures if required , pipe racks and cable supports provided,Ground , include unloading, shifting upto site at various location/levels, unpacking & inspection.The scope includes clamping of cables by ready made spacers, saddles or clamps fabricated out of Aluminium strip 3 mm thick along veritacal runs and wherever specified,cutting of the cable as per actual mesurement/cable schedule, Treasing and Clamping of Cable on cable tray velcrow tap of minimum 20mm width or clamping materials in Aluminium or PVC cable tie as per site Conditions. 3.5C x 95 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supply and Making end Termination with Brass Compression Gland and Aluminium Lugs for the Following Sizes of PVC insulated and PVC Sheathed/XLPE Aluminium Conductor Cable of 1.1 KV Grade as Required. 3.5C x 95 mm² LT XLPE (A2XFY) insulated Aluminium conductor PVC outer sheathed Armoured cable.
Supplying and Installing Following Size of Perforated G.I Cable Tray with Perforation not more than 17.5% in convenient Sections ,joined with connectors ,suspended from the Ceiling including bolts and Nuts ,etc as required.
150mm (W) x 50 mm (H) wide cable tray perforated type
300mm (W) x 50 mm (H) wide cable tray perforated type
V 2 ASSOCIATES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .