Loading…
Loading…
Tender Value
₹62.2 L
EMD Value
₹1.2 L
Closing Date
8 May 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
17 conditions · 5 needing a document upload
Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE- I/CT/GCC2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
34 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 11)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I (E-3320424), dated: 13.03.2026 (attached)
Electrical work in connection with (i) Provision of new Toilet, Bathroom, Suits, Kitchen and other misc. works at RPF Vatika Mess Barar Square in the section of SSE/W/S. P. Marg under ADEN/E-II. (ii) Provision of an Indoor Sports Complex (including 2 badminton courts) and an auditorium with a capacity of 200 in the 6BN/RPSF complex, Dayabasti.
75-SRDEE-G-DLI-2026-27
75-SRDEE-G-DLI-2026-27
Open
Works - General
9 Months
Delhi, Delhi
₹0
₹1.2 L
8 May 2026
16 Apr 2026
24 Apr 2026
95 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 62,21,802 | ||
| — | 645.00 | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 & conforming to IS 732:2024 or latest & as per explanatory note. Group C | — | — | — | 9,09,450 | |
| — | 1000.00 | — | — | ||
| Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. Size : 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | — | — | 2,64,000 | |
| — | 1100.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. Size : 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | — | — | 3,06,900 | |
| — | 700.00 | — | — | ||
| Wiring for circuit/ submain/power point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. Size : 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 2,52,700 | |
| — | 300.00 | — | — | ||
| Wiring for circuit/ submain/power point wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 & as per explanatory note. Size : 2 x 10 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 1,62,900 | |
| — | 180.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required and conforming to IS 3854:2023, IS 14772:2020 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 79,920 | |
| — | 130.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required and conforming to IS 3854:2023, IS 14772:2020 or latest & CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 72,410 | |
| — | 450.00 | — | — | ||
| Supply of ceiling rose, 3 plate conforming to IS : 371-1999 (or latest) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 31,500 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing & commissioning of Batten/Angle Holder conforming to IS : 1258-2005 (or Latest Version) & installation on the junction box of laid conduit including connections, testing & commissioning as per site requirement and as per Tech. Specification & as per explanatory note. | — | — | — | 2,420 | |
| — | 10.00 | — | — | ||
| Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB " C " curve including connections, painting etc. as required as per IS 13032:2016 and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 6,750 | |
| — | 34.00 | — | — | ||
| Earthing with 40 mm dia GI pipe class 'B' 4.5 meter long earth electrode as per IS:3043 (latest version) to achieve earth resistance less than 5 ohms including construction of masonry enclosures with hinged cover plate of cast iron with locking arrangement (approx. size 400 mm x 400 mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per drawing & as per explanatory note. | — | — | — | 1,95,534 | |
| — | 170.00 | — | — | ||
| Supplying and laying 25 mm X 5 mm G.I strip confirming to relevant IS as per IS:3043 (Latest version), fixing on surface or as per site condition, clamping or fixing with suitable arrangement as per site requirement, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) & as per explanatory note. | — | — | — | 26,180 | |
| — | 500.00 | — | — | ||
| Supplying and laying 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required as per IS:3043 (latest version) & as per explanatory note. | — | — | — | 27,500 | |
| — | 300.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255: 1983 (reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 c m and depth- 75 to 100 cm ] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Upto 35 sq.mm | — | — | — | 1,05,600 | |
| — | 300.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255: 1983 (reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 c m and depth- 75 to 100 cm ] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 1,26,300 | |
| — | 1500.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255: 1983 (reviewed in 2016) or latest including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm] etc as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 7,00,500 | |
| — | 100.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255: 1983 (reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Upto 35 sq. mm | — | — | — | 28,800 | |
| — | 100.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255: 1983 (reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 30,700 | |
| — | 400.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255: 1983 (reviewed in 2016) or latest in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority and conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm | — | — | — | 1,32,200 | |
| — | 100.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255: 1983 (reviewed in 2016) or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative & conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Upto 35 sq. mm (clamped with 1mm thick saddle) | — | — | — | 5,900 | |
| — | 100.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255: 1983 (reviewed in 2016) or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative & conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | — | — | — | 13,900 | |
| — | 400.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255: 1983 (reviewed in 2016) or latest. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative & conforming to CPWD General Specifications for Electrical Works Part-II External - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) | — | — | — | 66,600 | |
| — | 200.00 | — | — | ||
| Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required & as per explanatory note. 300 mm width X 50 mm depth X 1.6 mm thickness | — | — | — | 1,70,200 | |
| — | 250.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 1x18-20 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. CRI >=80, SDCM (standard deviation color matching) <3, The LED based 4 ft. tube light (lamp) shall be conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,60,750 | |
| — | 130.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 2x18-20 watt. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. CRI >=80, SDCM (standard deviation color matching) <3. The LED based 4 ft. tube light (lamp) shall be conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,41,440 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system 15-18 Watt CRI >=80, SDCM (standard deviation color matching) <3 complete with all mounting arrangement, accessories complete conforming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 79,700 | |
| — | 40.00 | — | — | ||
| Supply, fixing, testing and commissioning of 4-feet long surface mounting 36-Watt, 5700K,CRI>80, LED Luminaire as per relevant IS 10322 (Part 1):2014 Reviewed In : 2025, IE rules and site requirement. Fitting shall be environmentally friendly, long life, corrosion resistant, impact proof IP 66 with PC housing & opal finish cover suitable for wet location similar to Make - Havells Model No. MAGNUM NEO or equivalent. Fitting shall be suitable for operation on single phase 240Volt, 50 Hz AC supply and confirming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,24,000 | |
| — | 50.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body. Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 0C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Ceiling Fan compliant to IS 374:2019 or latest fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required & as per explanatory note. 1400mm, service value >= 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) | — | — | — | 1,36,850 | |
| — | 50.00 | — | — | ||
| Supply, fixing, Testing and Commissioning of 400 mm sweep BLDC wall mounted fan having Power wattage 32-35 Watt , Air delivery minimum 76 Cum/Min, suitable for 230 V, 50 Hz, single phase AC Supply and as per IS 555:1979 (reaffirmed 2020) complete & as per explanatory note. | — | — | — | 1,23,900 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of 400mm sweep wall mounted fan complete as per latest relevant IS/IEC standard & as per explanatory note. | — | — | — | 64,260 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of 250mm sweep fresh air fan complete conforming to IS 2312 & IS 302 or latest and other relevant IS/IEC standards & as per explanatory note. | — | — | — | 12,280 | |
| — | 5.00 | — | — | ||
| Supply, fixing, testing and commissioning of Heavy duty wall mounted air circulator fan 600 mm (24 inch), 1440 RPM ,180 watt, Air delivery 270 cubic meter per minute, No of blade 3, single speed, suitable to work on 230 Volts 50 HZ, single phase IS 2312 & IS 302 or latest and other relevant IS/IEC standards & as per explanatory note. | — | — | — | 30,565 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 45-50 watt LED based street light luminary with CRI >=70, SDCM (standard deviation color matching) <5 ,single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 59,300 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of 90W LED based street light luminary with cool white light, pressure die cast aluminum housing, IP 65 or latest complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 62,990 | |
| — | 10.00 | — | — | ||
| Supply of 150 watt LED based flood light luminary with cool white light, pressure die cast aluminum housing, IP 65 or better having system complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 70,500 | |
| — | 20.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150-155 W LED based Highbay light luminary with CRI >=70, SDCM (standard deviation color matching) <5, single housing, side entry, high pressure aluminum die cast/extruded aluminum, IP 66 or better having system complete confirming to CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest at Tech Spec-I attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-II attached or latest & as per explanatory note. | — | — | — | 1,85,800 | |
| — | 10.00 | — | — | ||
| Supply & erection of hot dip galvanized octagonal pole 5 Mtrs. long Double Arms, confirming to IS 2629/BSEN ISO 1461 latest version with top 70 mm and bottom 130 mm around face made of 3 mm thick, steel base plate size 200 x200x12 mm complete with appropriate sleeve at the top of the pole for mounting arm bracket 300 mm long suitable for LED street light fittings including casting, muffing with cement concrete foundation (1:2:4) painting, earthing and foundation GI nut, bolts with washer and smart pack junction box with 1A single pole MCB and terminals. Pole junction box shall be sealed with water proof tape and display of danger sticker & numbering shall be done with sticker/paint. Pole junction box cover should be non detachable ( with hinge) for anti - theft & as per explanatory note. Note- Wiring in between pole junction box to fitting shall be done through 3 cores 1.5 sq. mm FRLSH double insulated weather proof cables. | — | — | — | 90,180 | |
| — | 10.00 | — | — | ||
| Supply, installation, testing & commissioning of 25 ltrs stationary storage type electric water heater (Geyser) having BEE star rating- 5 star, Installation : vertical, ABS Body, element wattage - 2kW, Tank capacity - 25 ltrs, conforming to IS : 2082 with latest amendment complete and as per site requirement & as per explanatory note. Make : Havells, Bajaj, Usha or equivalent. | — | — | — | 1,12,940 | |
| — | 10.00 | — | — | ||
| Supply, fixing, testing and commissioning of 25A/32 A, 30 mA DP RCCB AC type confirming to IS 12640 latest & IEC 61008 latest with 10KA short circuit withstand capacity complete with enclosure (For Geyser's) & as per explanatory note. | — | — | — | 26,900 | |
| — | 4.00 | — | — | ||
| Supply, fixing, testing and commissioning of wall mounted LT distribution board made up of steel sheet, IP 43 phosphatised power painted complete with neutral link, earth point, Din rail and prewired confirming to IEC 60947 & IS/IEC: 61439 or latest, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. TPN MCB 63 Amps. 10KA 'C' series = 01 No. (Incoming) SP MCB 6-32 Amps. 10KA 'C' series = 18 Nos. (Outgoing) "It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal, reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables" | — | — | — | 22,764 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board surface mounting/recessed double door out door type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 43 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IEC 60947, Make- ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 61439, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. 63 A 4P RCBO 30/100 mA= 01 No. (Incoming) 6-32A MCB SP "C" Series =18 Nos. (Outgoing) "It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal, reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables" | — | — | — | 21,726 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of LT distribution board surface mounting/recessed double door out door type made up of CRCA sheet sheet with anti corrosion treatment and suitable, IP 54 phosphatised powder painted complete with neutral link, earth point, Din rail and prewired confirming to IEC 60947,Make- ABB, Siemens, L&T, Schneider, Legrand or equivalent with following items of matching make to be fixed in distribution board, confirming to IEC 61439, IE rules and site requirement. It should be rodent entry proof. It should also include well dressing and coding of circuit & as per explanatory note. 1x125 Amp 3 pole MCCB 35KA, (I/C) 12 Nos. 6-32 Amp single pole MCB 10 KA (O/G) "It should be rodent entry proof. It should also include well dressing and coding of circuit IP2X terminal, reversible door with 180 degree opening, cement spill protection, detachable gland at top and bottom and short link for MCBs. It should also include proper tagging on electrical wires/cables which clearly indicate the incoming point or source and outgoing point of wires/cables" | — | — | — | 46,074 | |
| — | 1.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar body made of CRCA sheet sheet with anti corrosion treatment and suitable having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947 or latest with digital measuring instrument & Al bus-bar arrangement conforming to IS/IEC 61439 or latest and as per IS, IE rules and site requirement. It should be dust proof and vermin proof, and powder coating and also provide polyamide cable gland with IP 68 protection & should suit the number, type and size of power cables & as per explanatory note. 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release = 01 No. (Incoming) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release = 02 No. (outgoing) 4P MCCB 63Amps 36 kA with adjustable thermal & fixed magnetic release = 04 No. (outgoing) | — | — | — | 1,10,078 | |
| — | 1.00 | — | — | ||
| Design, Supply, fixing, testing and commissioning of front operated double door type weather proof feeder pillar made of CRCA steel sheet having IP 65 protection (MCCB - Incoming & MCCB - Outgoing) comprising with the following MCCB's fixed in it of make: Siemens, L&T, Schneider, Legrand or equivalent conforming to IEC 60947 & IS/IEC:61439 or latest with digital measuring instrument & Al bus-bar arrangement and as per latest IS, IE rules and site requirement. It should be dust and vermin proof and powder coating as per IS 13871-2021 (or latest version) & as per explanatory note. a) 4P MCCB 400Amps 36 kA with adjustable thermal & fixed magnetic release =01 Nos. (Incoming). b) 4P 400 Amps on load change over switch (COS)=01 No. c) 4P MCCB 250Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). d) 4P MCCB 125Amps 36 kA with adjustable thermal & fixed magnetic release =04 Nos. (Outgoing). | — | — | — | 4,17,641 | |
| — | 250.00 | — | — | ||
| Supply, Laying, Testing and Commissioning of 160 mm dia HDPE pipe (PE-100, PN-6) conforming to IS:4984 or latest, for cable laying by trenchless Horizontal Directional Drilling (HDD) method as per IS:1255, IE Rules, CPWD and Indian Railways specifications, including detailed route survey, marking of alignment, pilot drilling, reaming, supply and laying of pipe by pull-back method with butt fusion/electrofusion jointing, use of suitable drilling fluid, and maintaining required depth and alignment (generally 1.5 m to 3.5 m or as directed). The work shall include preparation and submission of complete HDD report comprising route alignment drawings with chainage and coordinates of entry/exit points, section-wise details of HDD lengths, depth profile graphs (depth vs chainage), HDD logs, and photographic records, as per site requirements. The item also includes testing, quality assurance, protection of existing utilities, disposal of slurry, restoration of site, and all incidental works complete in all respects as directed by Engineer-in-Charge & as per explanatory note. | — | — | — | 2,68,750 | |
| — | 50.00 | — | — | ||
| Design, manufacture, display of wall / hanging / floor mounting type LED illuminated sign / direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed /router cut on monomeric calendered vinyl of 70 mm thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light. Suitable size endcap of 1.5 mm thick SS 304 should be provided as per Railway Board letter no.2023/SD-II/22/07/02 dated 15.05.2023 & as per explanatory note. | — | — | — | 1,21,400 | |
| — | 50.00 | — | — | ||
| Errection and installation of wall / hanging / floor mounting type LED illuminated sign /direction boards in half elliptical shape. The display sheet shall be of unbreakable 040 translucent polycarbonate sheet of 2 mm thickness. The text / graphics matter visibility shall not be less than 160 deg. The approved colour text and graphics shall be printed /router cut on monomeric calendered vinyl of 70 mm thickness and shall be firmly pasted on display sheets. The mounting arrangement shall be hanging, wall mounting, ceiling mounting, pole mounting or floor mounting and as per site requirement. The signage shall have the integral mounting arrangements with sturdy structural frame and ACP cladding on the back side of the signage to avoid rusting and entry of dust. The LED board shall have uniform illumination with 4-8 W / sq. ft and with brightness more than ambient light & as per explanatory note. | — | — | — | 12,150 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
SpecialConditions-75.pdf
ATTACHMENT
TenderDocuments-75.pdf
ATTACHMENT
ExplanatoryNote-75.pdf
ATTACHMENT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf GCC ACS No 11
ATTACHMENT
TECHSPEC-I.pdf
ATTACHMENT
TECHSPEC-II.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .