Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical 122 SAMHARIYA ASOPUR TANDA AMBEDKAR NAGAR UTTAR PRADESH 224190 | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | Accepted-Technical Responsive |
| 2 | Rejected-Technical | Rejected-Technical Non-Responsive |
| 3 | Rejected-Technical | Rejected-Technical Non-Responsive |
| 4 | Rejected-Technical 30 INDUSTRIAL AREA KOKAR RANCHI 834004 JHARKHAND | RANCHI | JHARKHAND | 834004 | Rejected-Technical Non-Responsive |
| 5 | Rejected-Technical | Rejected-Technical Non-Responsive |
Tender Value
₹3.8 Cr
EMD Value
₹21.2 L
Closing Date
8 Jan 2026, 12:00 pmClosed
SE NH CIRCLE PWD LUCKNOW
SE NH CIRCLE PWD 96 MG MARG LUCKNOW
Short term Maintenance Contract work for Ch 29.990 Km to 72.000 Km of NH-727H and Ch- 38.853 Km to 40.000 Km of NH-330D in district Sitapur in the state of Uttar Pradesh.
2025_MoRTH_890695_1
4675/808 YATA-NH Circle/2025-26 Dated 19.12.2025
Open Tender
Civil Works - Roads
Percentage
365 days
SITAPUR
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
AS PER BID DOCUMENT
₹21.2 L
SE NH CIRCLE PWD LUCKNOW
19 Jan 2026
19 Dec 2025
9 Jan 2026
19 Dec 2025
8 Jan 2026
19 Dec 2025
30 Dec 2025
Clearing Jungle including uprooting of rank vegitation, grass, brush wood, trees, sappling of girth up to 30cm measured at height of 1 m above of ground level and removal of rubbish up to a distance of 50 m outside of the perifery of the area cleared.
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
Brick work with common burnt clay(non-modular) bricks of class-150 in foundation and plinth in cement mortar 1:4 (1 cement :4 coarse sand)
12 mm cement Plaster of Mix 1:4 (1 Cement:4 Coarse Sand)
Road property maintenance
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) Maximum speed limit
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) Cautionary board
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) TRAFFIC SIGNS- HAZARD MARKER (LEFT & RIGHT)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) TRAFFIC SIGNS-SINGLE CHEVRON (NORMAL)
Providing and laying of hot applied thermoplastic compound 5mm thick including reflectorising glass beads @500gms per Sqm area,thickness of 5mm is exclusive of surface applied glass beads as per IRC-35-2015 . The finished surface to be level ,uniform and free form streaks and holes. Rumble Strip
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @250gms per Sqm area,thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35-2015 . The finished surface to be level ,uniform and free form streaks and holes.
Supply and fixing of raised pavement marker with made of plastic body of RPM/Road Stud shall be moulded from ASA(Acrylic styerene acrylontrite) or HIPS(High Impact Polystyrene) or acrylonitrite Butadien Styrene(ABS) or any other suitable material approved by the engineer .The marker shall support a load of 13.635 kg tested in accordance with ASTM D4280 . The reflective panels shall consist of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lense face. Lenses shall be moulded of methyl methecrylate conforming to ASTM D788 of equivalent . The slope or retro -reflecting surface shall preferebly by 35+/-5 degree to base and the area of each retro-reflecting surface shall nt be less than 13.00sqm the marker height shall not be less than 10mm and shall nt exceed 20mm and width shall not exceed 130mm . The base of the markker shall be flat within 1.3mm all road studs shall be legibly marked wth the name,trade or other means of identification of manufacturer .The contractor shall submit a two years warranty for satisfactory field performance includng stipulated retro-reflectance of the reflecti bg panel,to the engineer. In addition a 2 years warranty for satisfactry infield performance of the finished road marker ,shall also be given by the contactor who carries out of the work of the fixing of reflective road marker. In case the marker are displaced,damaged, get worm out or lose their reflectivity ,compared to stipulated standards ,the contractor would be reuired replace all such marker within 15 days of the intimation from the engineer, at his own cost. The rate shall include all material, labour T&P , Transportation ,Installation, and include incidental all complete as per direction of E-in-C.(Road Stud/cat Eye)
The solar stud shall be made of alluminium alloy and poly carbonate material which shall be absolutely wheather resistant and strong enough to support a load of 13,635 kg tested in accordance with ASTM D4280 ,its color may be of white , yellow, green, red or blue or combination as directed by Engineer. Its water resistance shall meet the requirement of IP 65 in accoradance with IS:12063:1987 category-2 for protection against water ingress . The dimensions of solar studs shall not be less than 100mmx100mmx10mm . it shall have super bright LEDs so as to provide long visibility from a distance of more than 800mm . Its flshing rate shall not be less than Hz. It should be able to give the prescribed performance in the temperature range of -40 to +55 degree . Its life shall not be less than 3 years. The rate shall include all the material ,labour, equipments,fabrication, transportation,erection,insrallationand incidentals all complete as per direction of E-In-C.( Solar Studs)
Providing and erecting a W metal beam crash barrier comprising of 3mm thick corrugated sheet metal beam rail , 70 cm above road/ground level fixed on ISMC series channel vertical post , 150x755 mm spaced 2 m centre to centre , 1.8m high, 1.1 m below ground /road level ,all steel partsand fitment to be galvanised by hot dip process , all fitting to conform to IS: 1367 and IS:1364 , metal beam rail to be fixed on the vertical post with a spacer of channel section 150x75x5 mm, 330mm long complete as per clause 810.
Pavement repair
Total length 25.780 km (NH-727H Ch-46.220 to 72.000 )
(NH 330D Km. 38.853 to Km 40.00)
Road maintenance
Clearing Jungle including uprooting of rank vegitation, grass, brush wood, trees, sappling of girth up to 30cm measured at height of 1 m above of ground level and removal of rubbish up to a distance of 50 m outside of the perifery of the area cleared.
Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-2.
Brick work with common burnt clay(non-modular) bricks of class-150 in foundation and plinth in cement mortar 1:4 (1 cement :4 coarse sand)
12 mm cement Plaster of Mix 1:4 (1 Cement:4 Coarse Sand)
Providing and laying dense graded bituminous macadam 50mm with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects.
Providing and laying bituminous concrete with higher capacity batch type hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.4 per cent of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects
Road property maintenance
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) Maximum speed limit
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) Cautionary board
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) TRAFFIC SIGNS- HAZARD MARKER (LEFT & RIGHT)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) TRAFFIC SIGNS-SINGLE CHEVRON (NORMAL)
Providing and laying of hot applied thermoplastic compound 5mm thick including reflectorising glass beads @500gms per Sqm area,thickness of 5mm is exclusive of surface applied glass beads as per IRC-35-2015 . The finished surface to be level ,uniform and free form streaks and holes. Rumble Strip
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @250gms per Sqm area,thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35-2015 . The finished surface to be level ,uniform and free form streaks and holes.
Supply and fixing of raised pavement marker with made of plastic body of RPM/Road Stud shall be moulded from ASA(Acrylic styerene acrylontrite) or HIPS(High Impact Polystyrene) or acrylonitrite Butadien Styrene(ABS) or any other suitable material approved by the engineer .The marker shall support a load of 13.635 kg tested in accordance with ASTM D4280 . The reflective panels shall consist of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lense face. Lenses shall be moulded of methyl methecrylate conforming to ASTM D788 of equivalent . The slope or retro -reflecting surface shall preferebly by 35+/-5 degree to base and the area of each retro-reflecting surface shall nt be less than 13.00sqm the marker height shall not be less than 10mm and shall nt exceed 20mm and width shall not exceed 130mm . The base of the markker shall be flat within 1.3mm all road studs shall be legibly marked wth the name,trade or other means of identification of manufacturer .The contractor shall submit a two years warranty for satisfactory field performance includng stipulated retro-reflectance of the reflecti bg panel,to the engineer. In addition a 2 years warranty for satisfactry infield performance of the finished road marker ,shall also be given by the contactor who carries out of the work of the fixing of reflective road marker. In case the marker are displaced,damaged, get worm out or lose their reflectivity ,compared to stipulated standards ,the contractor would be reuired replace all such marker within 15 days of the intimation from the engineer, at his own cost. The rate shall include all material, labour T&P , Transportation ,Installation, and include incidental all complete as per direction of E-in-C.(Road Stud/cat Eye)
The solar stud shall be made of alluminium alloy and poly carbonate material which shall be absolutely wheather resistant and strong enough to support a load of 13,635 kg tested in accordance with ASTM D4280 ,its color may be of white , yellow, green, red or blue or combination as directed by Engineer. Its water resistance shall meet the requirement of IP 65 in accoradance with IS:12063:1987 category-2 for protection against water ingress . The dimensions of solar studs shall not be less than 100mmx100mmx10mm . it shall have super bright LEDs so as to provide long visibility from a distance of more than 800mm . Its flshing rate shall not be less than Hz. It should be able to give the prescribed performance in the temperature range of -40 to +55 degree . Its life shall not be less than 3 years. The rate shall include all the material ,labour, equipments,fabrication, transportation,erection,insrallationand incidentals all complete as per direction of E-In-C.( Solar Studs)
Pavement repair
Total length 1.147km (NH-330D Ch-38.853 to 40.000Km)
Bill No.1 : Road maintenace (NH-727H Km. 29.990 to Km. 46.220)
Clearing Jungle including uprooting of rank vegitation, grass, brush wood, trees, sappling of girth up to 30cm measured at height of 1 m above of ground level and removal of rubbish up to a distance of 50 m outside of the perifery of the area cleared.
Earth work in surface excavation not exceeding 30Cm in depth but exceeding 1.5m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50m and lift 1.5m as directed by E-in-C 2.1.1. All kind of soil.
Brick work with common burnt clay(non-modular) bricks of class-150 in foundation and plinth in cement mortar 1:4 (1 cement :4 coarse sand)
12 mm cement Plaster of Mix 1:4 (1 Cement:4 Coarse Sand)
Bill No.3 : Road property maintenance
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) Maximum speed limit
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) Cautionary board
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) TRAFFIC SIGNS- HAZARD MARKER (LEFT & RIGHT)
Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC:67 mad of high intensity grade sheeting vide clause 801.3, fixed cover aluminium shting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x75 mm x6 mm firmly fixed to th ground by means of properly dsignd foundation with M-15 grade cment conc. 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing.(SOR Lko)MoRTH 801(8.4) TRAFFIC SIGNS-SINGLE CHEVRON (NORMAL)
Providing and laying of hot applied thermoplastic compound 5mm thick including reflectorising glass beads @500gms per Sqm area,thickness of 5mm is exclusive of surface applied glass beads as per IRC-35-2015 . The finished surface to be level ,uniform and free form streaks and holes. Rumble Strip
Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @250gms per Sqm area,thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC-35-2015 . The finished surface to be level ,uniform and free form streaks and holes.
Supply and fixing of raised pavement marker with made of plastic body of RPM/Road Stud shall be moulded from ASA(Acrylic styerene acrylontrite) or HIPS(High Impact Polystyrene) or acrylonitrite Butadien Styrene(ABS) or any other suitable material approved by the engineer .The marker shall support a load of 13.635 kg tested in accordance with ASTM D4280 . The reflective panels shall consist of number of lenses containing single or dual prismatic cubes capable of providing total internal reflection of the light entering the lense face. Lenses shall be moulded of methyl methecrylate conforming to ASTM D788 of equivalent . The slope or retro -reflecting surface shall preferebly by 35+/-5 degree to base and the area of each retro-reflecting surface shall nt be less than 13.00sqm the marker height shall not be less than 10mm and shall nt exceed 20mm and width shall not exceed 130mm . The base of the markker shall be flat within 1.3mm all road studs shall be legibly marked wth the name,trade or other means of identification of manufacturer .The contractor shall submit a two years warranty for satisfactory field performance includng stipulated retro-reflectance of the reflecti bg panel,to the engineer. In addition a 2 years warranty for satisfactry infield performance of the finished road marker ,shall also be given by the contactor who carries out of the work of the fixing of reflective road marker. In case the marker are displaced,damaged, get worm out or lose their reflectivity ,compared to stipulated standards ,the contractor would be reuired replace all such marker within 15 days of the intimation from the engineer, at his own cost. The rate shall include all material, labour T&P , Transportation ,Installation, and include incidental all complete as per direction of E-in-C.(Road Stud/cat Eye)
The solar stud shall be made of alluminium alloy and poly carbonate material which shall be absolutely wheather resistant and strong enough to support a load of 13,635 kg tested in accordance with ASTM D4280 ,its color may be of white , yellow, green, red or blue or combination as directed by Engineer. Its water resistance shall meet the requirement of IP 65 in accoradance with IS:12063:1987 category-2 for protection against water ingress . The dimensions of solar studs shall not be less than 100mmx100mmx10mm . it shall have super bright LEDs so as to provide long visibility from a distance of more than 800mm . Its flshing rate shall not be less than Hz. It should be able to give the prescribed performance in the temperature range of -40 to +55 degree . Its life shall not be less than 3 years. The rate shall include all the material ,labour, equipments,fabrication, transportation,erection,insrallationand incidentals all complete as per direction of E-In-C.( Solar Studs)
Providing and erecting a W metal beam crash barrier comprising of 3mm thick corrugated sheet metal beam rail , 70 cm above road/ground level fixed on ISMC series channel vertical post , 150x755 mm spaced 2 m centre to centre , 1.8m high, 1.1 m below ground /road level ,all steel partsand fitment to be galvanised by hot dip process , all fitting to conform to IS: 1367 and IS:1364 , metal beam rail to be fixed on the vertical post with a spacer of channel section 150x75x5 mm, 330mm long complete as per clause 810.
Bill No. 3 : Pavement repair
Total length 16.230km (NH-727H Ch-29.990 to 46.220)
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.34 MB
RFP727H330D.pdf
Tender Documents • 1.00 MB
BOQ_936199.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .