Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAGROTA
GE NAGROTA
DAY TO DAY COMPLAINTS OF EXTERNAL ELECTRIC AT VARIOUS LOCATION UNDER GE NAGROTA.
2022_MES_533870_1
GEN-40/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NAGROTA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE NAGROTA
₹98,000
Yes
4 Aug 2022
27 Jun 2022
30 Jul 2022
27 Jun 2022
28 Jul 2022
11 Jul 2022
60 days
Amount
M &L for Repair/Rectification of all electric fault , LT underground cable by using cable fault locator on site , rectifying the fault by using the cable , cable joint , lugs including excavation, returning filling, removal of excavated material, testing after the rectification of fault, complete all as specified and directed by Eng in Charge. Note : (a) All T&P /Cable fault Locator /Stationaries and labour team required comprising of Nos of Trained Electrician & Helpers will be provided by the contractor daily, as Required. (b) Rep of contractor will present in complaint cell & responsible for receiving & attending the complaint for round the clock . in absence of Rep of contractor penal recovery as decided by the GE shall be imposed on cotractor (c) Cost of minor stores such as screw, clamps, insulation tapes, nuts, bolts , nail of required size etc shall be deemed to included in the above quoted rate. However major items such as MCCBs , cables, Joints, Changeover etc shall be measured and paid seperately in respective items. (d) complaints where complete replacement of items required shall be measured and paid under relevent items. (e) If contractor fails to rectify the complaint within 24 hrs after which recovery of Rs 1000.00 per complaint will be panalised.
S & F XLPE cable, insulated,armoured, heavy duty electric cable with aluminium conductor,1100 volts grade, cross-sectional area 240 Sqmm 3.5 core including taking down old cable, complete all as specified and directed.
All as per ser item No. 02.00 here in above but cross sectional area 185 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 120 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 95 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 70 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 35 sqmm 3.5 core
All as per ser item No. 02.00 here in above but cross sectional area 25 sqmm 4 core
All as per ser item No. 02.00 here in above but cross sectional area 16 sqmm 4 core
S&F heat shrinkable straight through cable jointing kit 1.1 KV LT 4core XLPE cable cross sectional area 10 to 16 sqmm, complete all as specified and directed
All as per ser item No. 10.00 here in above but cross sectional area 25 to 50 sqmm
All as per ser item No. 10.00 here in above but cross sectional area 70 to 150 0sqmm
All as per ser item No. 10.00 here in above but cross sectional area 185 to 240 sqmm
Repair/Rectification of all electric fault occured in LT Panel , Cable, MCCBs, rectifying the fault by Replacing the cable , cable joint , lugs , MCCBs including dressing of Cable ,Change Over Switch ,Bressing and Jointing of DOORs , hooks, reconnecting to LT Panel and testing after the rectification of fault, complete all as specified and directed by Eng in Charge. Note : (a) All T&P /Stationries and labour team required comprising of Nos of Trained Electrician & Helpers will be provided by the contractor daily, as Required. (b) Rep of contractor will present in complaint cell & responsible for receiving & attending the complaint for round the clock . in absence of Rep of contractor penal recovery as decided by the GE shall be imposed on cotractor (c) Cost of minor stores such as screw, clamps, insulation tapes, nuts, bolts , nail of required size etc shall be deemed including in the above quoted rate. However major items such as MCCBs , cables, Joints, Changeover etc shall be measured and paid seperately in respective itmes. (d) complaints where complete replacement of items required shall be measured and paid under relevent items. (e) If contractor fails to rectify the complaint within 24 hrs after which recovery of Rs 1000.00 per complaint will be panalised.
Supply and fixing in replacement, Adjustable Thermal & Fixed Magnetic MCCB 630 amps capacity, four pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 400 amps capacity, four pole 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 250 Amps, four pole, 415 volt with breaking cap 36 KA, , complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 200 Amps, four pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 100 Amps, four pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 63 amps capacity, four pole, 415 volt with breaking cap 16 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 400 amps capacity, three pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 250 amps capacity, three pole, 415 volt with breaking cap 36 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 200 amps capacity, three pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 100 amps capacity, three pole, 415 volt with breaking cap 25 KA, complete all as specified and directed.
Supply and fixing in replacement Adjustable Thermal & Fixed Magnetic MCCB 63 amps capacity, three pole, 415 volt with breaking cap 16 KA, complete all as specified and directed.
S & F in repair MCB TPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 40860 or equivalent I ABB / Siemens
S & F in repair MCB TPN 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 40863 or equivalent I ABB / Siemens
S & F in repair MCB SPN 32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 408609 to 408617 or equivalent I ABB / Siemens
S & F in repair MCB SPN 40 to 63 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 408618 to 408620 or equivalent I ABB / Siemens
S & F Change over switch off load type with enclosure, conforming IS 13947 part I & III 415V, 4 pole of rating 63 amps, including taking out old unserviceable one, complete all as specified and directed by Engineer-in-charge.
All as per ser item No. 26.00 here in above but capacity 100/125 amps
All as per ser item No. 26.00 here in above but capacity 200 amps
All as per ser item No. 26.00 here in above but capacity 400 amps
Supply and fixing in replacement voltmeter of size 96 x 96 mm, complete all as specified and directed.
Supply and fixing in replacement amp meter of size 96 x 96 mm, complete all as specified and directed.
Tape wound LT CTs of ration 100/5 Amp at 5 VA CT for class 1.0 seconday current upto capacity of 500 Amp of Primary current, complete all as specified and directed by Eng in Charge.
M&L for cleaning, preparing of Lt panel of any size and painting with two coats of synthetic enamel paint , complete all as specified and directed.
Supply and fix aluminium lugs of any type / shape of capacity 400 Sqmm
'Supply and fix aluminium lugs of any type / shape of capacity 300 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 240 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 185 Sqmm
'Supply and fix aluminium lugs of any type / shape of capacity 120 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 95 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 70 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 50 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 35 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 25 Sqmm
Supply and fix aluminium lugs of any type / shape of capacity 16 Sqmm
Supply and fix GI Nuts, bolts, screws, washers of required sizes
S&F Stainless Steel Double Compression Cable Glands, Size: up to 20mm
all as per item No 50 above but of size 25 - 40 mm
all as per item No 50 above but of size 50 - 80 mm
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed. Make: Havells,Polycab,Plaza
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed. Make: Havells,Polycab,Plaza
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 16 Sqmm complete all as specified and directed. Make: Havells,Polycab,Plaza
Labour only for repair/rectification/re-stringing restraching of all electric fault occured in OH ACSR conductor laid over, over head LT line on steel / PCC poles after removing binding from insulator and rewinding the conductor with insulator including providing spacer and new binding wire jumpering provide with after restraining and removing unavoidable sags in the line and trimming of tree and branches on LT line for minimum clearance, complete all as specified and directed.
Supply only PVC line spacer of superior quality suitable for four line of ACSR over head lines, complete all as specified and directed.
Supply only PVC line spacer of superior quality suitable for three line of ACSR over head lines, complete all as specified and directed.
Cross arm, bracings, supports, clamps and chequered steel back plates, angle iron equal size or any size fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size for cover for cable duct any size and holding of two pole strucures, GOD, street light GI bracket, junction boxes and fabrication of anti climbing devices, other works etc as indicated or directed and duly painted with synthetic enamel aluminium/smooke grey paint over a coat of primer fixed "as in repairs", complete all as specified and directed .
M&L for Aluminium conductor, steel reinforced of any size on LT Poles including straining,binding with insulators with Al/copper binding wire with insulators as in over head conductors, providing PVC Sleeves for jumper fixed as in repairs, complete all as specified and directed.
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia for 1100 volts grade, complete all as specified and directed.
S & F in repairs Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150 mm height, 150 mm dia for 11000 volts grade, complete all as specified and directed.
S & F in repairs Shackle type porcelain, vitreous, white, brown or green insulator 1100 volts working pressure, 100mm high and 115mm dia with and including galvanised mild steel staps washers insulator bolts 12mm dia, washers and nuts, complete all as specified and directed.
Cleaning, preparing and painting with two coats of silver synthetic enamel paint on 9/11m poles, cross arms, MS channels, angle iron, frame work bracing including numbering of pole and writing of feeder name with black enemelled paint from stencil, complete all as specified and directed.
S&F in repairs switch air break gang operated (Swing out expulsion ruse insulators), tripple pole mechnical operated from ground level mounted on insulator and steel frame (15 insulators type) out door type suitable for vertical installation single break provided with locking arrangement consisting of MS channel HT post top insulator with drop out fuses operating rod 20mm dia GI medium grade pipe worked from ground level confirming of IS 1818 of 1972 and continuous current rating upto 200 amp and volt 11 KV, complete all as specified and directed.
Supply and fixing of male contact/moving contact blade 200 amp of Air Break switches complet with nuts and Bolts of capacity 11 KV, complete all as specified and directed by Eng In Charge.
Supply and fixing of female contact/Fix contact Jaw 200 amp of Air Break switches complet with nuts and Bolts of capacity 11 KV, complete all as specified and directed by Eng In Charge.
Supply and fixing of tinned copper flexible jumper 200/400 amp with ms jumper carrier for Air Break switches complet with nuts and Bolts of capacity 11 KV, complete all as specified and directed.
Cleaning of MES electric supply insatllation/Campus/Four pole structure by surface dressing or trimming of natural ground to remove small un equilities not exc 15 cm deep (incuding removing vegetation including shrubs /brushwood /undergrowth etc) carrying away the rubbish to a distance of not exc 50 m away, complete all as specified and directed.
S&F in repairs12 mm dia and 300 mm long air termination, single pointed aluminium rod , complete all as specified and directed.
S&F in repairs 12 mm dia and 300 mm long air termination, single pointed copper rod , complete all as specified and directed.
Supply and fixing in repair of aluminium strip 25 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fixing in repair of copper strip 20 x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed.
Supply and fixing in repairs earth continuity conductor or main earthing lead fixed to walls on batten or recess or chesses or buried in ground or fixed to poles or any other indicated situation for loop earthing with using 32 x 6 mm dia GI strip, complete all as specified and directed.
Supply & Fixing 20 mm bore dia steel water tubing galvanised iron (light grade) with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed.
Taking down transformer of any size,any capacity and reinstalling after repair of platform ( including lifting of transformer from the existing platform and reinstalling of transformer on new platform).Note: The quoted rate include the rate of Hydra Machine for lifting the transformer from one positions to another
M & L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as foundation filling and mass concreate in foundation of pole/stays, complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in foundation, filling and mass concrete in foundatin of pole/stay, complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1, (using 20 mm graded crushed stone aggregate) as in copying above ground level around the plole, complete all as specified and directed.
Supply and erection in truely vertical position steel tubular swaged poles, type 410 SP-55 (11.00 meters) with 300 mm x 300 mm x 6 mm mild steel base plate continuously welded to poles, finial taper plug, bolts, nuts and screws all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embedded portion and making 30 cms wide strips with yellow and black paint at alternatively upto 1.50 metre height and applying two coats of aluminium paint over a coat of red oxide primer on remaining exposed surface after erection including taking down of old unserviceable existing pole any size any type ,complete all as specified and directed.
M&L for stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed.
Earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick, burried directly in ground preferably in vertical position (Earth pit not less than 2.25 mtr below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level, connected to galvanised iron strip 25×4 mm by means of bolts, nuts, check nuts and washers of galvanised iron including pit of PCC (1:2:4) type B-1, pre cast RCC cover slab of size 550x550x75mm, XPM reinforced not less than 1.60Kg/Sqm with suitable built in handle made from 12mm dia MS round bar, excavation and earth work in any type of soil, 20mm dia bore medium grade galvanised iron water tubing fixed with cast iron funnel and wire mesh at one end, 15mm bore light grade galvanised iron protection pipe for earth lead wire upto 5m length, charcol, common salt complete all as shown in electric plate No 5 of SSR 2009 Part I connected to equipment, testing on completion, complete all as specified and directed.
S&F in replacement of post top Lantern of capacity 12 W energy saving , environmental friendly, long life aesthetically designed with symmetrical light distribution spun aluminium land scape luminaire with high power LEDs as light source . The luminare shall be complete IP65 for optical compartment suitable gor working for input voltage range of 140 V to 270 V Light shall have power factor more than 0.9 with THD less than 10%.having lm of 900w including complete electrical connection with fixing arrangement complete all as specified and directed by Eng in Charge. Make : HPL Cat part No HPLLEDPDC12W or equivalent in CG, Bajaj,Hallonix
S&F in replacement post top Lantern of capacity 15W new generation , IP 65 LED Post top family, energy saving, enviorment friendly, long life aesthetically designed with symmetrical Light distribuation, spun aluminium landscape luimianaire with high power LED as light source with opal cover offers soothing uniform illumination for different applications.Make : Havells Cat Part No CORALMINIPT15WLED830PSYMTOPC or eqivalent in CG, Bajaj,Halonix
Supply and fix in replacment 9 W LED bollard light fitting with opal arylic diffuser and IP 65 protection powder coated square extruded aluminium housing. Mushroom Shape Opal acrylic diffuser is fixed in die cast aluminium frames on four sides for pleasant light output with inbuilt driver with 4.5 kV surge protection.Luminaire is provided with a base plate and fixing holes for directly mounting on the concrete pedestal.LEDs mounted on top die cast aluminium housing and can be separated from base plate for easy maintenance. Make HPL cat part No HPLLEDB9W or equivalent in Bajaj,CG,Havells,Halonix
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge . Make : HPL Cat part No HPLLEDFL12060FP equivalent in CG,Bajaj,Havells,Halonix
Supply and fix in replacment LED decorative spike light of 6 W using cob LED source with aluminium enclosure complete all as specified and directed. Make : HPL cat Part No HPLLEDSP0660 or equivalent in CG,Bajaj, Havells,Halonix
Supply and fixing Junction box made of SMC/FRP sheet ready made of size 300 mm x 200 x 105 mm having 100 A Capacity RYB and neutral aluminium bus bar of 3 mm thick duly fitted on suitable insulator, and MCB SP 6 A 10 KA 240V -01 No. with fixing arrangement fixed properly to pole/fixed on wall with MS Clamps 25x5 mm and nut and bolts complete all as specified and directed by the Engineer-In-Charge.
S&F in replacment for PVC insulated multicore stranded copper Cable of 2.5 Sqmm of 3 Core multi flexible round cable ,complete all as specified and directed by Engr-in-Charge.
S&F in replacment Single core PVC insulated copper cable of 2.5 Sqmm complete all as specified and directed by Engineer -in- charge.
Supply, Fixing , Commissioning and tessting of CPRI approved outdoor cubical type LT Feeder Piller box suitable for 415 V, 3 Phase , 4 wire 50 Hz , AC Supply system fabricated from stainless steel totally encloused ,dust, weather & vermin proof , 3.00 mm thick for outer shell and 2 mm thick for inner shell having MS section not less than 50x50x6 mm thick having TPN aluminium busbar of capacity 200 Amps mounted on porcelain insulator duly drilled hole for cable connection including front and rear side opening with locking arrangement, with MCCB FP 63 Amp, 16 KA, 415 Volts 50 Hz with adjustable thermal and adjustable magnetic setting and provn for incoming and outgoing cables with glands including control wiring with minimum 1.5 sqmm PVC insulated copper conductor for measuring of voltage, amp with indicators RYB ,painting with two coat of smoke grey synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge Make : Chandel Electric Company, Gupta & Friends, Jaima Electrical Note:- Feeder pillar box shall be mounted on brickwork in CM 1:4 not less than 60 cm above ground level with suitable foundation, rendering 15 mm in CM 1:6 and two coats of cement base paint and the rates shall be inclusive in the quoted rate.
M&L in repair complete Servcing of Double drum winch, grasing of gear and repair of pully arrangment and make smooth function of High mast light complete all as specified and directed.
S&F in repair for fabrication and installation of terminal box outdoor canopy type, size 40cm (Height) x 30 cm (width) x 12 cm (thick), size of canopy 30cm x 13 cm complete with locking arrangement, 4 Nos aluminium busbar size 20 x 5mm, 8 Nos nut bolt, & 8 Nos aluminium cable socket suitable for upto 95 sqmm cable embeded in PCC foundation with 2 Nos angle iron leg 25mm x25mm 400 mm long as per sample including taking down complete all as specified and as directed. Make : Chandel Electric Company, Gupta & Friends, Jaima Electrical
S & F in repair MCB SPN 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 408609 to 408617 or equivalent inABB / Siemens
S & F in repair MCB SP 6-32 Amp 415 volts 50 Hz AC 10 KA with necessary lugs including lugs, including taking taking down exsting MCB complete all as specified Make Legrand Cat no 408609 to 408617 or equivalent in ABB / Siemens
S & L cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 4 core 16 Sqmm complete all as specfied and directed.
S & L cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 4 core 10 Sqmm complete all as specfied and directed.
Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete.
Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete.
Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I, complete all as specified and directed by Engr-in-Charge..
M&L for Brick covering with width equal to length of brick as mechanical protection to cables with well burnt sub class ‘B’ (old size) bricks laid dry flat, complete all as specified and directed.
Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass complete.
Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete.
Providing cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in copings to poles & the like, etc including weathering, slightly rounded or chamfered angles and throating as directed including necessary form work complete.
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed. Make: Havells,Polycab,Plaza
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed. Make: Havells,Polycab,Plaza
Service cable/wire 1100 V flat twin core aluminium stranded conductor of size 16 Sqmm complete all as specified and directed. Make: Havells,Polycab,Plaza
M & L for Cross arms, bracing, supports, clamps and back plate, fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as directed .Dismantling and taking out damage/rusted cross arms, bracings, supports, clamps and back plates from existing poles / dismantled poles / pole structures complete all as directed.
Nitika electricals and engineers works
MAMTA ENTERPRISES
Bidder Name
G R CONSTRUCTIONS
Nitika electricals and engineers works
MAMTA ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .